ABB ACS550 AC Drive Basic Startup

  Рет қаралды 649,846

GalcoTV

GalcoTV

Күн бұрын

Пікірлер: 211
@MR-nl8xr
@MR-nl8xr 7 жыл бұрын
By far the best presentation this representative has given in ANY of the other Galco TV videos.
@GalcoIndustrial
@GalcoIndustrial 7 жыл бұрын
Thank you for your kind words. Anything else you would like to see presented or tested in our Galco investigative videos and industry news, please don't hesitate to post here.
@engineerkohat
@engineerkohat 7 жыл бұрын
Excellent demonstration of the drive. Great upload.
@denverhoward3446
@denverhoward3446 3 жыл бұрын
I dont mean to be off topic but does anybody know of a way to log back into an Instagram account..? I stupidly lost my account password. I love any assistance you can give me.
@jayceonarthur2365
@jayceonarthur2365 3 жыл бұрын
@Denver Howard Instablaster =)
@denverhoward3446
@denverhoward3446 3 жыл бұрын
@Jayceon Arthur Thanks so much for your reply. I got to the site thru google and Im waiting for the hacking stuff now. I see it takes a while so I will get back to you later when my account password hopefully is recovered.
@denverhoward3446
@denverhoward3446 3 жыл бұрын
@Jayceon Arthur It worked and I now got access to my account again. Im so happy! Thanks so much you really help me out!
@jayceonarthur2365
@jayceonarthur2365 3 жыл бұрын
@Denver Howard glad I could help :)
@shaffisk5328
@shaffisk5328 4 жыл бұрын
Really gud demo in understanding way..tnq so much Mam..plz upload more videos in same way..tnq
@LandSnipe415
@LandSnipe415 11 жыл бұрын
She is definitely a hottie. And I use ABB ACH 550's and this tutorial helped me operate some cooling tower fans in Local/Manual mode just now, saving our 2ndary chiller plant in our building where I work as an Engineer. And I now look like a God at work. Thank you! My point? She teaches well and that too is hot.
@rehaloverehalove9398
@rehaloverehalove9398 7 жыл бұрын
thanks alot for your reply, there was no fault showing, I figured that this is a matter of relay output stting and I was right , I just change parameter 1403 in group 14 from 3 to 4 which activate the relay output only in case of fault instead of been on by default.... thanks alot again for your support, you are the best
@GalcoIndustrial
@GalcoIndustrial 11 жыл бұрын
Sure. You can set the macro to ABB standard (parameter 9902 - also the default). Then connect the pot to pins 2,3, and 4 with the wiper being on 2. Make sure you close the start/stop on pin 13 (digital input 1). Now switch the keypad from local to remote and the speed pot should work.
@mrmidnight32
@mrmidnight32 3 жыл бұрын
Mine always shows €0.10 /day. What does that account for? And why isn’t it in USD? Is that how much it should cost me a day? Also how do you calculate it? I see in settings I can change the value to what ever I want.
@wesleyrabelo8611
@wesleyrabelo8611 12 жыл бұрын
It´s great!I don´t know ABB products but now I need to operate a machine on my work
@SuperSlashgnr
@SuperSlashgnr 3 ай бұрын
How to prereset the command speed function to be at 0 everytime the drive switched on? I had a problem that my drive preset at 50hz everytime.
@donhenderson4668
@donhenderson4668 12 жыл бұрын
I completely overlooked that. Thanks for the support.
@GalcoIndustrial
@GalcoIndustrial 11 жыл бұрын
We can certainly try to help, but it might be a bit difficult in this format. What is it that you are looking to do?
@LoganOConnor-v5d
@LoganOConnor-v5d 2 ай бұрын
Very helpful thank you!
@GalcoIndustrial
@GalcoIndustrial 11 жыл бұрын
Sorry we weren't able to help you out sooner. As for any connections to ABB Canada, unfortunately we are not able to be of much help. Galco is a distributor of ABB, but we don't often have communication with their HR department. We wish you success in finding work in this field and hope to hear from you in the future.
@ashokshrisaran
@ashokshrisaran 4 жыл бұрын
Interesting demonstration and useful guideness
@automationengineeringknowl8762
@automationengineeringknowl8762 4 жыл бұрын
Informative presentation, love ABB Drives......
@moomoomoo7737
@moomoomoo7737 Жыл бұрын
Hello, any tips if remote control wont work even though rem/loc is already selected? and how to restart the vfd? thanks
@ptsushil2010
@ptsushil2010 4 жыл бұрын
excellent......but can I program frequency beyond 5 Hz say @ 65 Hz ? plz tell me
@vladseb2009
@vladseb2009 11 ай бұрын
Hello, if volts used for the motor is 230v. Why are you using 0.8 amps and not 1.4 that falls under 220-240v?
@jkj1459
@jkj1459 9 жыл бұрын
very helpful explanation thank you very much ABB.
@eeeknowledge2850
@eeeknowledge2850 6 жыл бұрын
Informative presentation, love ABB Drives
@GalcoIndustrial
@GalcoIndustrial 6 жыл бұрын
Thanks
@zikomoon2450
@zikomoon2450 10 жыл бұрын
Hi Galco, Thank for this valuable video. Please, can explain how to control the ABB ACS550 through a computer by using Drive windows Light 2.
@selvarasumanikandan7646
@selvarasumanikandan7646 3 жыл бұрын
Thanks for this VEDIO nice.
@haisridhar10
@haisridhar10 7 жыл бұрын
USEFUL VIDEO..GOOD DEMO..kINDLY UPLOAD VIDEO FOR THE ELECTRICAL CONNECTIONS EXPLANATIONS, FAULT RESET AND FOR FAQ..
@Sudhirtechnical
@Sudhirtechnical 4 жыл бұрын
I have updated new video for ABB ACS550 Drive.
@DC61223
@DC61223 6 жыл бұрын
Very good presentation !!
@paccbutler1826
@paccbutler1826 5 жыл бұрын
If you remove the keypad while VFD is in operation, will this disable the drive, or will it temporarily continue to run?
@GalcoIndustrial
@GalcoIndustrial 5 жыл бұрын
The drive will continue to run. However, it must be in REMOTE control mode to do so. If keypad is in LOCAL control mode and running and you remove the keypad the drive will fault.
@paccbutler1826
@paccbutler1826 5 жыл бұрын
@@GalcoIndustrial Got it, thank you
@stevero2581
@stevero2581 4 жыл бұрын
If the display is blank, even with a new battery, is it the drive or interface?
@shujanizami1990
@shujanizami1990 4 жыл бұрын
i want to know about this fault code F 0022. I have facing this fault continuous on my motor as its speed suddenly increasing just before reaching up to motor stop. this related to DC bus about ripple voltage. How can i rectify this problem.
@markdavid4809
@markdavid4809 2 жыл бұрын
Can I run 230volts motor from a acs550 vfd 460volts supply??
@rehaloverehalove9398
@rehaloverehalove9398 7 жыл бұрын
hello , very nice explanation I have ACS550 that issue a fault alarm at RO3 between terminals 25 and 27 as soon as the drive power up ? I can't determine the cause can you help me ?
@GalcoIndustrial
@GalcoIndustrial 7 жыл бұрын
What fault is the display showing you?
@mattquinlisk
@mattquinlisk 5 жыл бұрын
That exact VFD you have there, is it possible to have it ramp up faster?
@learningexploring5717
@learningexploring5717 3 жыл бұрын
Thank you for sharing :)
@myomyint8711
@myomyint8711 7 жыл бұрын
now input signal is using DI1 and DI3 for two speeds. I would like to use DI1 input only for two speeds.
@dudewhat9880
@dudewhat9880 Жыл бұрын
Can somebody help me regarding unitrol 1000. I want to copy parameters and my problem is that I don't know if should I supply the unit or not. and what is the supply voltage range. thanks
@longvehoanguyen1479
@longvehoanguyen1479 7 жыл бұрын
You can show how to read the value directly from the inverter to the computer (by modbus)
@emirhankanlar7780
@emirhankanlar7780 4 жыл бұрын
Can you explain where did you get 1 hp please?
@GalcoIndustrial
@GalcoIndustrial 12 жыл бұрын
Good to hear. Galco carries a wide variety of ABB products and we are more than willing to help if you need it. Also, don't forget to subscribe to G-TV for more product features and how to videos!
@ศุภโชควรรธนะมณีกุล
@ศุภโชควรรธนะมณีกุล 3 жыл бұрын
Now display show Hz, A and %. If I want the display rpm. How to set display?
@brent2k5
@brent2k5 2 жыл бұрын
How do I change the display in the upper right corner to read rpm instead of hz?
@banglakobita1872
@banglakobita1872 Жыл бұрын
Pls tell me how to adjust valu without heart use span and zero step by step ABB PRESSURE Transmeter. 2600T .
@MrEnroh
@MrEnroh 8 жыл бұрын
Hi GalcoTV. I have 63 acs550 units running in my department. We are slowly trying to switch them all to run remotely via Honeywell scada. we have encountered issue s though with our older drives will not work due to their firmware. I'm wondering if you guys know a simple way of uploading firmware off of our newer drives and then downloading that firmware to our older drives. Thank you in advance.
@GalcoIndustrial
@GalcoIndustrial 8 жыл бұрын
There is no way for the end user to change the firmware in the drive, only the factory can do it.
@pranabop
@pranabop 3 жыл бұрын
Thank you so much ❤️
@GalcoIndustrial
@GalcoIndustrial 10 жыл бұрын
Adarsh Thakarey For someone reason I am unable to reply to you directly, so let me know if this went through. Go to Parameter 1604 “FAULT RESET SEL”. This will allow you to select a digital input that can be used for external fault reset.
@zeiussocampo4763
@zeiussocampo4763 10 жыл бұрын
Hi ! it is possible i can run by scada the acs550 i wil use the drive relay ?
@GalcoIndustrial
@GalcoIndustrial 10 жыл бұрын
zeiuss ocampo I am not really sure what you are trying to do, but an ACS550 can be run off of a scada if the outputs of the scada match the inputs of the drive. Also, I am not too sure on what you mean by drive relay... Are you referring to the drive's output relays?
@ifeanyiyoung5661
@ifeanyiyoung5661 8 жыл бұрын
sorry i delayed,you was of great assistance but after which it reset and the fault reoccurred,mean while what happens now is that when you want to varry the speed it will trip at above 0.7hz with same fault f004.but when i bring it down to 0 or little above to run for like 10-20 minutes it can them varri the speed.the out put power supply is stable,pls is there any fault inside the drive or what to reset
@ifeanyiyoung5661
@ifeanyiyoung5661 8 жыл бұрын
engr adarsh,can u please send me your personal contact so that i can call and talk with you for a better guide. thanks, best regards young 07035325166
@saigopalbisoyi1032
@saigopalbisoyi1032 8 жыл бұрын
GalcoTV
@vishalbhosale9985
@vishalbhosale9985 5 жыл бұрын
Good info. Ty
@boddapallisuresh7288
@boddapallisuresh7288 6 жыл бұрын
Please make vedio about VFD Macro terminals and how they are using.
@GalcoIndustrial
@GalcoIndustrial 6 жыл бұрын
Ok I'll suggest it to our producers.
@GalcoIndustrial
@GalcoIndustrial 6 жыл бұрын
You mean the different control I/O terminal configurations for the different parameter Macro selections?
@satvirsinghgill1598
@satvirsinghgill1598 11 жыл бұрын
as i have done my industrial training from ABB dealer in India and now need a presentation on ABB drives... should contains greatest points like principle of drive b, basic information about..and so on... can u please help me..
@longvehoanguyen1479
@longvehoanguyen1479 7 жыл бұрын
Can you tell how to read values directly from inverter to computer (by modbus) ... how to call values in file path ... for modbus ...
@davidmaycunich2
@davidmaycunich2 6 жыл бұрын
We have an ABB ACS600. None of the buttons seem to work. But other than that, it seems to be working correctly. We are trying to see if any fault codes are available. Any suggestions?
@GalcoIndustrial
@GalcoIndustrial 6 жыл бұрын
I have to assume you mean the buttons on the keypad, if so replace the keypad and try accessing fault log again. This drive is obsoleted now though and we do not sell anything for them accept repair service.
@Alfredlgo
@Alfredlgo 11 ай бұрын
Impressive
@electricaltech4u45
@electricaltech4u45 6 жыл бұрын
Nice .but how I connect MBS 300 transmitter??
@GalcoIndustrial
@GalcoIndustrial 6 жыл бұрын
We do not have these transmitters so you will have to tell me what you are using the transmitter for, ok?
@electricaltech4u45
@electricaltech4u45 6 жыл бұрын
@@GalcoIndustrial thanks.dear sir I want to use this drive for water purpose .I want when our water pressure 3 bar motor run and when reach 4 bar motor stop.i have transmitter .but how I don I need ur professional and best help. thanks
@GalcoIndustrial
@GalcoIndustrial 6 жыл бұрын
This will take some intricate programming of the drive. So I'm going to suggest you give us a call and talk to 1 of our product managers. 800-337-1720
@electricaltech4u45
@electricaltech4u45 6 жыл бұрын
@@GalcoIndustrial ok thanks .
@skrappyMK1
@skrappyMK1 4 жыл бұрын
How can the drive run on auto after programming instead of hand ?
@DouglasSilva-gf5ig
@DouglasSilva-gf5ig 5 жыл бұрын
O variador ACS 550 está apresentando alarme 2201. porém entrei no grupo 22 para retirar o alarme , mas o inversor apresentou o código 5022 grupo ou parâmetro protegido por escrita . Tentei buscar esse parâmetro para desbloquear- ló mas o variador só tem até a opção 5011 . Como faço para desbloquear esse parâmetro 5022 ??
@dipanjandas9463
@dipanjandas9463 5 жыл бұрын
If vfd trip, how to reset? Please make a video on this.
@vish2305
@vish2305 6 жыл бұрын
Good breaking, thanks!
@vish2305
@vish2305 6 жыл бұрын
Good briefing, thanks !
@GalcoIndustrial
@GalcoIndustrial 12 жыл бұрын
Since a VFD converts AC into DC and then inverts the DC into a variable voltage and frequency AC, switching two of the input wires has no effect on the output. You need to switch two of the output wires from the VFD to the motor in order to reverse motor direction. Let me know if this helps. If not, I will be happy to assist you further or you can contact a technical specialist through galco.com.
@josepmariaalabartjosa3258
@josepmariaalabartjosa3258 3 күн бұрын
Hola como puedo resetear el variador para que quede en modo fábrica Es un abb acs550 Gracias
@ElingJuz479
@ElingJuz479 6 жыл бұрын
recently we have problem on our VFD ACS510 which cant run on REM mode, what should i do? i do swap the key pad from the other VFD , result still the same.. pls. advice tq
@GalcoIndustrial
@GalcoIndustrial 6 жыл бұрын
Is the REM indicator in upper left corner of keypad display going "REM" to "LOC "when you push the LOC/REM button?
@anasnori9801
@anasnori9801 10 жыл бұрын
This is one amazing video..... thanks alot
@diocatahum8220
@diocatahum8220 3 жыл бұрын
hi, i have error 2023 to my vsd acs 550 - how can i correct it. thanks ,please advise
@roseateelectronics8498
@roseateelectronics8498 7 ай бұрын
Acs550 k cpu card ko 5.5kw sy 18 kw main convert krna hy.plz help Acs550 cpu card convert 5.5kw to 18kw
@soundarele7268
@soundarele7268 8 жыл бұрын
Very good
@velulovesgubu
@velulovesgubu 6 жыл бұрын
Mam...What will happen if the 3 phase output of VFD is connected to input of a 3 phase transformer..I was asked this during an interview...will the transformer burn....?
@GalcoIndustrial
@GalcoIndustrial 6 жыл бұрын
Drives are not meant to run a transformer and transformers are not built to be fed with PWM type power. PWM power may cause over heating when miss used like this, we will not recommend it.
@velulovesgubu
@velulovesgubu 6 жыл бұрын
GalcoTV okk
@adarshthakarey1
@adarshthakarey1 10 жыл бұрын
is there digital input for Reset drive in ACS550?
@abdelkadernekrouf7537
@abdelkadernekrouf7537 3 жыл бұрын
How to install the EDS files for an ABB-ACS 550 drive with a Canopen RCAN-01 adapter module.
@rashidkhan-ky8wt
@rashidkhan-ky8wt 9 жыл бұрын
HI , we have purchased a ABB ACS510 , we would like to configure it for constant pressure water boosting system, we have 3 pumps and would like to configure it to SPFC (soft start for all pumps) , but we are not able to configure the same. Shall be highly obliged if you could help us with the configuration. Thanks & Regards Rashid Khan
@wjimenezu
@wjimenezu 6 жыл бұрын
Easy to understand. And you're beauty
@joaocostinha1825
@joaocostinha1825 3 жыл бұрын
Estou com um Driver CÃS 500 e está dando uma Falha Gnd Fault. O que pode ser?
@GalcoIndustrial
@GalcoIndustrial 11 жыл бұрын
It is a little unclear on what you are trying to accomplish. Are you saying that you are getting a maximum of 9 Hz when you are at 10 Volts?
@anoopthirutheri8535
@anoopthirutheri8535 3 жыл бұрын
What are the parameters for profibus ID configuration??
@mt-07rider74
@mt-07rider74 5 жыл бұрын
My drive seems to be showing rpm and not Hz where is the parameter to change this? Thanks
@myomyint8711
@myomyint8711 7 жыл бұрын
model is (ACS550-01-08A8-4) input signal 4-20mA is already installed AI2 and GND
@GalcoIndustrial
@GalcoIndustrial 7 жыл бұрын
Ok then go to parameter 1103 and set to 2, that will select AI2 as the reference source, ok?
@GalcoIndustrial
@GalcoIndustrial 7 жыл бұрын
But also keep in mind, the digital inputs programmed to select preset speeds will override the analog inputs if activated, ok?
@myomyint8711
@myomyint8711 7 жыл бұрын
I changed parameter 1103 to 2 for AL2 but drive is still no work for 2 speed.And then i changed signal input from AI2 to AI1 with jamper switch AI1 is on and parameter 1103 to 1. AI1 input signal is work for two speed surely and i don't understand why AI2 input is no work for two speed till i changed parameter 1103 to 2. thanks so much.
@GalcoIndustrial
@GalcoIndustrial 7 жыл бұрын
Myo I'm going to recommend you talk with 1 of our product managers about your issue. Please call 800-575-5562 and ask for Randy Barbret or call him direct at 248-336-4591, ok?
@thiradejkaewmongkol1271
@thiradejkaewmongkol1271 7 жыл бұрын
I got new ABB Inverter ACS - 550 but keypad same ACS-355 AC drive when put main power AC drive don't run tell me can setting program and AC drive run by potentiometer. Ac drive 3 PH 400 V.
@arunagirimanickam363
@arunagirimanickam363 4 жыл бұрын
ABB ACS550 vfd control panel right side corner frequency setting is 50HZ but motor is working 30HZ why?
@ismailrazzouk6599
@ismailrazzouk6599 8 жыл бұрын
I have a problem, my drive ABB gives the 5001 alarm, what does that mean and how I can be deleted for it normally starts, and thanks
@GalcoIndustrial
@GalcoIndustrial 8 жыл бұрын
Alarm 5001 means “Drive is not responding”, this is usually a loss of communications between the drive and the keypad. I would suggest, with the power off, remove the keypad and the connector that goes between the drive and the keypad and then reset them. This will quit often fix the problem, if not try a different keypad and see if the problem follows the keypad or the drive and replace the defective component.
@umairghafoor335
@umairghafoor335 4 жыл бұрын
ABB ACH 550 for hvac not go up 40%.what is fault
7 жыл бұрын
hi guy! I want to setting ABB ACS550 connect Modbus RTU with PLC. I made effort setting for inverter ABB ACS550 But it so difficult for me. If you have any video teach setting Inverter connect modbus RTu. Please send me as soon as possible. Thanks you so much.
@GalcoIndustrial
@GalcoIndustrial 7 жыл бұрын
Hello Nguyen, good question and thanks for asking Galco. Do you have a copy of the ACS550 User Manual? If not click on this link for a digital copy www.galco.com/techdoc/abbi/acs550-u1-038a-4_um.pdf Be sure parameter 9802 = 1 (Standard Modbus), then check parameter 5302= "Drive address" (this must be a unique number for each drive connect to a common trunk line) 5303= "baud rate" selected must match all items connected to same line. So 5302 must all be unique numbers, and 5303 must be the same number. 5304= "Parity selection" must match all items connected and 5305 leave default=0. Please let us know how you do.
7 жыл бұрын
Hi guy! Thanks you so much i used setting ABB inverter as you say.I just only read value feedback from inverter. when i write value for inverter it can not run, so i very confuse about this matter. Please talk me know this problem.
@arbabahmed6227
@arbabahmed6227 5 жыл бұрын
my vfd showing ALARM 2021 and it write down that( start enable enable 1 missing ) . and then when I in detail I mean in diagnosed it write there comm linesand connections parameter 3002, parameter in groups 10 and 11
@samuelkambuzuma7841
@samuelkambuzuma7841 8 жыл бұрын
i want to download the procedures on how to programme a drive and also a video
@myomyint8711
@myomyint8711 7 жыл бұрын
yes i would like to run two speeds by using output from pressure controller and transmitter.
@GalcoIndustrial
@GalcoIndustrial 7 жыл бұрын
OK Myo, for Analog input 1 connect your signal to X1 terminal 2+ & 3 -, and to use 4-20ma type signal you must flip switch J1 position 1 to ON and this configures AI1 for a ma signal, ok? Keep in mind the drive will run on the analog signal inputs automatically if no Preset speed input is activated. The preset speed select inputs will always override the analog inputs, ok?Good luck
@ifeanyiyoung5661
@ifeanyiyoung5661 8 жыл бұрын
please how can i reset fault f004 in acs550 abb,note the electric motor is disconnected and its wires removed ,but the fault persisted .please what next if it its a component fault or i.c,or igbt how can i locate it i can carefully replace it unless
@GalcoIndustrial
@GalcoIndustrial 8 жыл бұрын
Remove all wiring except for three phase power, if fault still exists, it’s most likely a drive problem. In the manual it states that it could caused be a supply disturbance, you could try a different power source just to make sure. If the fault clears after removing all the wires, try reconnecting one wire at a time to figure out which wire is causing the fault. As for repair, depending on the size of the drive, there may not be parts available. Most drives just have a single part in the drive, so if you were to get that, you basically bought the drive.
@aminooozzzelsawy3095
@aminooozzzelsawy3095 10 жыл бұрын
how can I change the working status of the drive from the hand mode to the auto mode?
@GalcoIndustrial
@GalcoIndustrial 10 жыл бұрын
If you're using the hand/auto macro then it should just be a digital input. If you mean hand being the keypad and auto being a terminal strip, then it should be just the local/remote button on the keypad. To be honest, I will need to have a little more information. What type of macro are you in and what are you trying to accomplish?
@jeffreyritaga6063
@jeffreyritaga6063 4 жыл бұрын
How to fix inhibit problem if ABB? Can somebody help me?
@joelleon3730
@joelleon3730 7 жыл бұрын
I need to make the drive start automatically when powered How can I accomplish this?
@GalcoIndustrial
@GalcoIndustrial 7 жыл бұрын
The drive doesn't seem to have a direct configuration for power-on RUN mode. However if you jumper the start input (actual terminal depends your Macro selected) the drive will go right into run mode in a couple seconds of power-on, ok?
@satvirsinghgill1598
@satvirsinghgill1598 11 жыл бұрын
sorry i was too late to reach you, as my presentation is most probably in one or two days..i was extremely happy with your reply..can u plz help me in finding the job in abb Canada as i was migrated to Canada near about in three or four .I have done electrical diploma and pursuing with degree ..it will greatly valuable info. for me..x
@myomyint8711
@myomyint8711 7 жыл бұрын
now drive is running by contact input. I would like to run by 4-20mA input . how to change parametres?pls.
@GalcoIndustrial
@GalcoIndustrial 7 жыл бұрын
Clarify please, you want to just control the speed with 4-20ma signal?
@Leonardo_Vargas123
@Leonardo_Vargas123 11 жыл бұрын
For decrease o low Hz, just i need to change the parameter?? we have this to conected from device 0-10V but when we have de maximum of voltage only decrease to 9 hz, can you help me
@GalcoIndustrial
@GalcoIndustrial 11 жыл бұрын
If you are looking for a video on the features of ABB Drives, we can certainly make one. We would be happy to be used as a resource, but I am unsure if the completion time will fit in with your schedule. When do you need this?
@hjelectricalservicesandind1209
@hjelectricalservicesandind1209 5 жыл бұрын
I have abb asc 510 drive I've set the motor data base on the name plate of the motor but the motor did not run.. The drive appearing ( drive not ready) e.g low dc voltage.. Plz help
@donhenderson4668
@donhenderson4668 12 жыл бұрын
I followed the steps in the video, but my motor went in the opposite direction. I switched two of the input power wires going to the VFD and it made no difference. I also checked to made sure that the display shows the motor is going in the forward direction. So why is mine going in the reverse?
@sparkypdx
@sparkypdx 2 жыл бұрын
You need to swap two of the output wires instead.
@prakashdew3978
@prakashdew3978 6 жыл бұрын
can we change its direction in motor stop condition?
@GalcoIndustrial
@GalcoIndustrial 6 жыл бұрын
Yes of course you can, the direction of rotation can be changed anytime, running or not. The keypad display will indicate the direction change with the little arrow next to the REM/LOC indicator in upper right corner of the keypad display.
@samchikashi2146
@samchikashi2146 4 жыл бұрын
what causes a DC Undervoltage alarm
@vorapobautomation9760
@vorapobautomation9760 7 жыл бұрын
I use ACS550 How can I edit AO1 parameter from current to voltage ?
@GalcoIndustrial
@GalcoIndustrial 7 жыл бұрын
You can not change the output current to voltage with a parameter. Use a 250 ohm resistor across the output for 5 volts at 20ma, or 500 ohm for 10 volts at 20ma.
@vorapobautomation9760
@vorapobautomation9760 7 жыл бұрын
Can you send me wiring diagram ? My E-mail: tonsc2002@hotmail.com
@GalcoIndustrial
@GalcoIndustrial 7 жыл бұрын
Just click this link for a copy of entire user manual, ok www.galco.com/techdoc/abbi/acs550-u1-038a-4_um.pdf
@vorapobautomation9760
@vorapobautomation9760 7 жыл бұрын
Which page please ?
@fullelectric7264
@fullelectric7264 7 жыл бұрын
Dear chanel Galca TV. I have inverter ABB ACS 550, I use application macro Hand - Auto I installed 9902 = 5. I want use AI2 = 0-10V, What I have to do? Please help me
@GalcoIndustrial
@GalcoIndustrial 7 жыл бұрын
Find switch J1 (2 position DIP switch) and move position 2 to off position. Default is 1=off (for 0-10volt input) and position 2=on for current input. If you move it to off position both inputs will be set for 0-10volt input, ok?
@fullelectric7264
@fullelectric7264 7 жыл бұрын
Thank you repply. I have installed DIP AI1 and AI2 = off ( Move DIP switch AI1, AI2 = U). Then use PLC Analog Output siemens s7-1200 send 0-10V to AI2 inverter but inverter not running? DI3, DI4, DI6 Auto mode OK on
@GalcoIndustrial
@GalcoIndustrial 7 жыл бұрын
Make sure that your PLC has put some reference on AI2 so the drive knows how fast to go.
@fullelectric7264
@fullelectric7264 7 жыл бұрын
Yes. PLC out analog 0-10V OK. I have used voltage meter at AI2 = 5V. Do not know if I have to install anything else in the inverter?
@GalcoIndustrial
@GalcoIndustrial 7 жыл бұрын
At this point I will have to refer you to 1 of our product managers for more specific help. So give us a call at 800-575-5562 and ask for ABB drive assistance, ok?
@sanchuvarghese2161
@sanchuvarghese2161 3 жыл бұрын
How to wire in remote mode ?
@koipin
@koipin 7 жыл бұрын
Not sure if anyone can help on here. Is there a parameter to switch a motor between star-delta wiring?
@GalcoIndustrial
@GalcoIndustrial 7 жыл бұрын
No, the drive can only put out 3 phase power and there are only 3 output terminals. What you are talking about requires a hard wire change at the motor wiring itself.
@alisuliman1529
@alisuliman1529 10 жыл бұрын
how are you please help me i want to run abb drive acs550 01 as torque control mode i connect drive as shown in manual and i put parameter 9902 =8 the drive is run and there is flash in display monitor "rev" but the motor not rotate i connect the ref to A1 (2,3,4) but when i put 9902=1 speed control the motor is run Best regards
@GalcoIndustrial
@GalcoIndustrial 10 жыл бұрын
When you switch the parameters on 9902, the wiring for the IO also changes. A1 should still be the same, but you will also need to close the run enable (DI 6/pin 18) and to switch between speed and torque control you can check the connection on DI 3/ pin 15. Check to see if that works.
@adampiotrmalejewski695
@adampiotrmalejewski695 7 жыл бұрын
thank you
@sayedsoliman4474
@sayedsoliman4474 6 жыл бұрын
i have VFD for fan control low speed high speed is totaly stoped and the screen is not start up and i have power at panel . please tell me what is the problem
@GalcoIndustrial
@GalcoIndustrial 6 жыл бұрын
Try asking the question again, but the screen is display on keypad,,, right? and by startup you mean it does not come on at all OR the drive does start running?
@sayedsoliman4474
@sayedsoliman4474 6 жыл бұрын
No, the screen is not dis play on keypad
@GalcoIndustrial
@GalcoIndustrial 6 жыл бұрын
Have you replaced the keypad yet? If so, It sounds like the the power supply in the drive has failed, replace the drive.
@jaimedelgdo89
@jaimedelgdo89 3 жыл бұрын
How do you change the language
@noordeensheik
@noordeensheik 11 жыл бұрын
Hi,can you jst tell me how to connect Speed POT in drive and desire parameter for pot
@philipsf859
@philipsf859 6 жыл бұрын
You may miss a step:upload your settings or programming into vsd, isn't?
@GalcoIndustrial
@GalcoIndustrial 6 жыл бұрын
Can you ask a different way?
Частотник ABB ACS550 - по параметрам
18:52
Петров Андрей работа АСУ ТП
Рет қаралды 27 М.
What Types of Motors Can Be Used with VFDs?
6:58
eMotors Direct
Рет қаралды 79 М.
pumpkins #shorts
00:39
Mr DegrEE
Рет қаралды 119 МЛН
Хасанның өзі эфирге шықты! “Қылмыстық топқа қатысым жоқ” дейді. Талғарда не болды? Халық сене ме?
09:25
Демократиялы Қазақстан / Демократический Казахстан
Рет қаралды 338 М.
[Tutorial] ABB ACS355 VFD Setting
10:17
plc247 Automation
Рет қаралды 47 М.
ABB ACS-150 AC Drive Basic Start Up & Operation Demo
5:00
GalcoTV
Рет қаралды 220 М.
Variable Frequency Drives Explained | VFD Basics - Part 1
8:35
How to Upload or Download programming in ABB Variable Frequency Drives
5:14
System Control Tech
Рет қаралды 73 М.
ABB ACS510 AC Drive Basic Startup
6:53
Electrical Bangla
Рет қаралды 10 М.
How to Wire Up an ABB ACS150 Drive
5:43
GalcoTV
Рет қаралды 182 М.
What is the Difference between VFD and Soft Starter?
7:30
RealPars
Рет қаралды 2,4 МЛН
ABB ACS550 VFD 2 WIRE CONTROL CONFIGURATION
14:42
Industry Automation
Рет қаралды 42 М.
ABB ACS 355 AC Drive Basic Start Up Advanced Control Pad
6:03
pumpkins #shorts
00:39
Mr DegrEE
Рет қаралды 119 МЛН