How to Wire Up I/O on ABB ACS-355 AC Drive for ABB Standard Macro

  Рет қаралды 293,708

GalcoTV

GalcoTV

Күн бұрын

Пікірлер: 63
@majn8017
@majn8017 4 жыл бұрын
i am using ACS580 and i want to connect external potentiometer, so please which terminal i need to connect to and do I need to program it to accept the potentiometer voltage or its automatically will accept it
@qbanz00
@qbanz00 2 ай бұрын
I know this is late but I think she said 2,3,4
@kingofslotsmillion3263
@kingofslotsmillion3263 3 жыл бұрын
How do I program Terminal 12 to stat up on comand I followed all these steps but motor wont start . what setting tells Drive Im using terminal 12
@haqiqireza3233
@haqiqireza3233 4 жыл бұрын
can you help me how to find the output transistor
@shahzadelectrical2927
@shahzadelectrical2927 Жыл бұрын
Sir abb ki new driver ha model 355 ha bht is pa A2035 alram plz help me
@onthemudd1
@onthemudd1 10 жыл бұрын
thanks for your response. I set everything as you stated. This is what is happening as soon as I press the Start button the motor runs even though the pot is set to zero. even in local mode. the running current is above full load and the drive trips. The output is 150% over the rated current,not clear whats up here. Is their a factory reset apart from 9904 changing then changing it back.
@GalcoIndustrial
@GalcoIndustrial 10 жыл бұрын
Well it might be a bad pot, but that shouldn't happen in local mode... The overload could be caused by the motor running at full speed from the start. This is only an assumption based on what you have mentioned. Do you know what the motor is running at when the drive trips? Also, I don't know if this is a typo or not, but the factory reset is 9902 and not 9904. Changing the macro to something else and then back to ABB standard will reset all drive parameters with the exception of the motor data. Remember to recheck the motor data in parameter group 99 to ensure it matches with the nameplate data.
@sethuramvenkatesh
@sethuramvenkatesh 10 жыл бұрын
I want the drive to run(start powering the motor) soon after getting itself powered up. I thought bypassing the start push button would do. Is it the correct method to follow?
@GalcoIndustrial
@GalcoIndustrial 10 жыл бұрын
Yes, you can close the switch so that the motor will start to run when power is applied to the drive. To do this, you will need to keep the drive in remote mode. But the drive will still take a second to power up. I would recommend leaving the drive on and then just using a start switch as if it were an on/off switch.
@tgifadi77
@tgifadi77 8 жыл бұрын
sethuram venkatesh chowdhary b
@jacoboborjas8601
@jacoboborjas8601 6 жыл бұрын
Good video could explain how to connect potentiometer for remote use of an acs150 thanks
@baskarvp4149
@baskarvp4149 5 жыл бұрын
How can i Connect speed indicator with ABB ACS355 Drive ? please suggest me indicator model no...
@arumugamm5313
@arumugamm5313 5 жыл бұрын
Madam in my solar 5hp motor that drive will be on in display F0035 indicated pls help me
@GalcoIndustrial
@GalcoIndustrial 5 жыл бұрын
This is serious, do not attempt to run the drive. This fault is indicating that you have line power on the motor terminals. Please correct this as soon as possible!
@nell434
@nell434 2 жыл бұрын
Gracias por el video.........muy entendible
@electricaltech4u45
@electricaltech4u45 6 жыл бұрын
Can you show multi pump switching.of Schneider altivar 61
@GalcoIndustrial
@GalcoIndustrial 6 жыл бұрын
That would have to go to engineering
@technicaljd4823
@technicaljd4823 7 жыл бұрын
How can connect pot in sinamick v 20 and also NO NC switch
@zhiwei6680
@zhiwei6680 5 жыл бұрын
Hi, where do the 9 connect to? And the function of it.
@coolingmasters1892
@coolingmasters1892 6 жыл бұрын
Hii I want to know how can set parameter setting when I start the unit Abb acs 355 drive show 0001..4 when I push exit it's start i do this every time when unit startAnd other I want to blower motor rotation reverse or farward which parametersettng can sout out this
@umangkejriwal9509
@umangkejriwal9509 8 жыл бұрын
please also provide a wire up tutorial for abb acs550 vfd
@majiiidsaber7804
@majiiidsaber7804 3 жыл бұрын
درود بر شما افرین لذت بردم .
@stephensamuel1726
@stephensamuel1726 7 жыл бұрын
i need your help. my ABB ACS-355 display a fault "drive not responding" and there fault light
@GalcoIndustrial
@GalcoIndustrial 7 жыл бұрын
If you are referring to the display on the Keypad, this message means the drive isn't responding to communication from it. Try a different keypad if you haven't already and the little connector adapter too. Good luck, and please let us know how this works for you, ok?
@mohanmohan-ti7zy
@mohanmohan-ti7zy 6 жыл бұрын
I need your help,our abb acs355 drive display can,t work,same time cooling fan is not functioning
@michaelkolawole2444
@michaelkolawole2444 6 жыл бұрын
how do i rest an ABB ACS320 drive that is starting but not producing output after resting on earth fault
@GalcoIndustrial
@GalcoIndustrial 6 жыл бұрын
Ok when you say rest, do you mean reset? If so the drive should run after resetting any fault that has cleared the condition that caused it. Make sure the drive has speed reference if in remote control. If in local control, the drive may reset the local reference when faulted unless your model has the speed pot installed in the keypad. If speed reference source is confirmed ok and drive still doesn't respond then the drive itself may have sustained permanent damage and will need repaired or replaced.
@stanleyogwezi390
@stanleyogwezi390 7 жыл бұрын
I have a challenge on new abb ACS150 Drive I connected all the necessary connection and is not working on remote only on LOC REM work.i follow all instructions.if I change set point of 9902 to 4 only work only one direction very slow movement.what will be the case please I need your help now Thanks
@GalcoIndustrial
@GalcoIndustrial 7 жыл бұрын
With 9902 set to 4, you are set up for the motor potentiometer macro. First make sure you are in remote mode using the REM/LOC button, the display will show REM on the middle of the left side. Using this macro, you need to apply 24VDC to the DI1 terminal to start the drive in a forward direction. To go in a reverse direction apply 24VDC to both the DI1 and DI2 terminals. By applying 24VDC to the DI3 terminal the speed will increase until the 24VDC is removed, at that point the drive will stay running at whatever the speed it was at when the 24VDC was removed from DI3. By applying 24VDC to the DI4 terminal, the speed will decrease until the 24VDC is removed, at that point the drive will stay running at whatever the speed it was at when the 24VDC was removed from DI4. The rate at which the speed will increase is controlled by parameter 22.02. The rate at which the speed will decrease is controlled by parameter 22.03. Don’t forget to put the jumper wire in between terminals GND and COM like the wiring diagram shows.
@GalcoIndustrial
@GalcoIndustrial 7 жыл бұрын
Ok please click on this link to the manual and look at page 79, it will list all the parameters you need for the Application Macro you have selected at 9902 www.galco.com/techdoc/abbi/acs150_um.pdf Good luck
@maintenancevyline591
@maintenancevyline591 6 жыл бұрын
I want to Reset All parameters to company default. means reset the drive to defaults.How can I reset all parameters to its defaults value.?please suggest
@GalcoIndustrial
@GalcoIndustrial 6 жыл бұрын
Abb does not have a parameter for defaulting the drive to factory values. So what you have to do is go to parameter 9902 and select "ABB Standard" macro. If the drive is already selected to ABB Standard, then simply change it to another macro and back again. This effectively defaults the drive, however it does not effect the motor parameters those will have to be set to the new motor manually. There are other parameters not defaulted as well, but if using a simple application without Field Bus control, it shouldn't matter, ok?
@abidhussain4233
@abidhussain4233 6 жыл бұрын
i want basic installation abb drive
@onthemudd1
@onthemudd1 10 жыл бұрын
I have setup an ABB 355 to run remotely Connected a pot and a stay-switch parameter 9902 - 1 ABB STD the motor Ratings are 3ph 230 V 1.5 A 60 Hz 0.55 K.W. 1380 R.P.M Store in Parameters 9903, 9905,9906,9907,9909,9908 the motor is expected to run 0 - 40 RPM the Scalar motor mode is used. PAR 2001 is 0.0 Hz PAR 2002 1,7Hz 1103 - 1 ,I am not sure how to set 1104 and 1105 the manual says 1=0.1Hz should I use 17.0 for 1.7Hz? the motor just races as soon as the pot is turned and i have no control unless I stop the drive then I have to turn the pot to its min that start over and the same thing happens Please Assist
@GalcoIndustrial
@GalcoIndustrial 10 жыл бұрын
Parameters 2001 and 2002 are intended for vector mode, since you have it in scalar, you should change the parameters in 1104 and 1105. If you want 1.7 hertz then you can set 1105 to 1.7 Hz. This should allow for your pot to reach 1.7 Hertz at 100 percent. (assuming you want 40 RPM as your maximum) If you are having trouble controlling the drive with the pot, there are a couple of things to look at. First, is the dip switch by the I/O on the front of the drive. (You can see this on page 53 of the manual). You will want to set AI 1 to the off position to ensure that you are using a 0-10 Volt signal. This assumes the pot is wired to AI 1. The next thing to look at is parameter 0120, which can be accessed even when the drive is stopped. This will display the value of the pot from 0-100 percent. If the pot is wired incorrectly or if it is not in working condition, the value here will show 100%. Let me know if this helps.
@onthemudd1
@onthemudd1 10 жыл бұрын
Yes the current goes to 6.XXamps this should obviously trip the OL because of its rating I am beginning to suspect the motor will be making a substitution will tell you how this turns out. It was a Typo its 9902 indeed. thanks for your help so far Great Stuff
@GalcoIndustrial
@GalcoIndustrial 10 жыл бұрын
No problem! Glad to be of help and let me know how it works out for you.
@shahzadelectrical2927
@shahzadelectrical2927 Жыл бұрын
​@@GalcoIndustrial sir abb drive model number problem alram code a2035 plz help
@tedrosafenegus4461
@tedrosafenegus4461 8 жыл бұрын
It would be nice to have PID loop control and trouble shooting tutorial. I am installing water pump that must maintain 60 PSI. so I installed three wire pressure traducer with 0-100PSI, 4-20MA. I am not sure what I am making mistake. It is not working in remote control. is it wiring, programming or bad sensor ........................if you can help I appreciate.
@GalcoIndustrial
@GalcoIndustrial 8 жыл бұрын
OK Tedros, I would like you to check a couple things, but keep in mind I have to assume you already have the PID Macro loaded ok? Make sure the display says "REM" on the left side (this indicates that it is in remote mode), next make sure you have a jumper at terminals 10 and 11, next make sure you have your run enable input closed at DI4 (or terminal 15), if all these check correct, then determine if you are in "HAND" or "PID" control mode with DI2, DI2 off = HAND, DI2 on = PID mode. You have 2 different start inputs, DI1 starts HAND or DI5 starts PID based on the state of DI2, ok? Good luck and let us know what happens
@ghizoqueen231
@ghizoqueen231 7 жыл бұрын
Progressive start and stop progressive, what output should I use?
@GalcoIndustrial
@GalcoIndustrial 7 жыл бұрын
Are you asking about the analog output?
@seimela
@seimela 2 жыл бұрын
i have purchased two Si-EtherCat modules from Galco they gave me ,they gave 67 lead time ,i waited ,after 67 days they say i will only get them in January 2023 ,i have requested refund to no avail ,i need help
@vikrammishra7541
@vikrammishra7541 6 жыл бұрын
Where to connect 7 and 8 number terminals?
@in5n80
@in5n80 6 жыл бұрын
Across 7 and 8 the drive outputs an analog signal between 0mA to 20mA, which can be connected to a process controller or PLC and display the frequency of the drive output.
@henilshah9389
@henilshah9389 7 жыл бұрын
How can i Connect speed indicator with ABB ACS550 Drive ?
@GalcoIndustrial
@GalcoIndustrial 7 жыл бұрын
Use analog output 1, it is preprogrammed for speed indication. I/O connector X1 terminals 6=AGND and 7=AO1, ok?
@ismailelmouhaddib5354
@ismailelmouhaddib5354 7 жыл бұрын
The acs355 drive sowing fault code (A5001). That means the drive is not responding. So how i solve the fault
@GalcoIndustrial
@GalcoIndustrial 7 жыл бұрын
A5001 may be a keypad fault, it does not see the drive. Make sure the keypad is seated in place correctly, if no improvement, try another keypad and the little RJ45 adapter piece. Let us know what happens, ok?
@stephensamuel1726
@stephensamuel1726 7 жыл бұрын
I am having this same issue, there is also fault light on the vfd. please i need your support
@narinderbatish4772
@narinderbatish4772 7 жыл бұрын
What is the function of 7 and 8 number termnial.
@GalcoIndustrial
@GalcoIndustrial 7 жыл бұрын
Terminal 7 is the analog output, and terminal 8 is analog common. This output comes default programmed for speed signal indication, ok?
@stanleyogwezi3595
@stanleyogwezi3595 8 жыл бұрын
I want you to teach how to program inverter from ac150 to ac800 thanks
@GalcoIndustrial
@GalcoIndustrial 8 жыл бұрын
Hi Stanley, we have video's on the ACS150, ACS355, ACS550 and ACS880 for wiring and startup if you haven't found them already. The ACS800 is in progress as we speak though. So keep an eye on us for that to show up, ok?
@cyjiljose70371
@cyjiljose70371 7 жыл бұрын
How to change the direction of the motor forward and reverse with this drive?
@ayushmanpadhy3497
@ayushmanpadhy3497 7 жыл бұрын
Thanks
@praveenbabugolla9758
@praveenbabugolla9758 4 жыл бұрын
Nice
@ghizoqueen231
@ghizoqueen231 7 жыл бұрын
please i want to aske you for the
@diliphadiyal3312
@diliphadiyal3312 4 жыл бұрын
What
@carry7261
@carry7261 6 жыл бұрын
Plz show the importance of connecting earthing to vfd😑
@GalcoIndustrial
@GalcoIndustrial 6 жыл бұрын
It's important to connect ground/earth to the VFD and the motor to the VFD ground. Motors produce a lot of EMI into the frame and if not grounded properly it will make the frame of the motor and possibly the VFD as well at high potential to ground. This is a dangerous situation if you come into contact with VFD or motor frame not grounded.
@roberto-facciolitecnologia2845
@roberto-facciolitecnologia2845 2 жыл бұрын
error A 5014 and F0035
@cocuckeo7973
@cocuckeo7973 5 жыл бұрын
i don't no
ABB ACH580 HVAC Drive Basic I/O Connections
5:01
GalcoTV
Рет қаралды 10 М.
How to Wire Up an ABB ACS150 Drive
5:43
GalcoTV
Рет қаралды 184 М.
1% vs 100% #beatbox #tiktok
01:10
BeatboxJCOP
Рет қаралды 67 МЛН
Support each other🤝
00:31
ISSEI / いっせい
Рет қаралды 81 МЛН
Variable Frequency Drives Explained - VFD Basics IGBT inverter
15:18
The Engineering Mindset
Рет қаралды 3,2 МЛН
ABB ACS 355 AC Drive Basic Start Up Advanced Control Pad
6:03
How to commission the ACS355 machinery drive
5:09
ABB Drives
Рет қаралды 37 М.
Inside the V3 Nazi Super Gun
19:52
Blue Paw Print
Рет қаралды 2,5 МЛН
How to Wire a PLC Control Panel Like a Pro
9:06
Chris Guyatt
Рет қаралды 140 М.
What Types of Motors Can Be Used with VFDs?
6:58
eMotors Direct
Рет қаралды 93 М.
How to wire a  VFD / variable frequency drive
5:02
VFDs.com
Рет қаралды 723 М.
1% vs 100% #beatbox #tiktok
01:10
BeatboxJCOP
Рет қаралды 67 МЛН