AC 034 - Nonseparated Occupancies.

  Рет қаралды 6,808

archicorner

archicorner

Күн бұрын

Пікірлер: 21
@FakhreAlBobali
@FakhreAlBobali 2 ай бұрын
Hello, though I'm watching a year ago great video but it is really important to highlight that in the requirements of fire systems in chapter 9 that and I quote "IBC 201 section 907.2. Not fewer than one manual fire alarm box shall be provided in an approved location to initiate a fire alarm signal for fire alarm systems employing automatic fire detectors or waterflow detection devices." Really I like the subject and it is really important to understand. Thank you!
@WillDiMichele
@WillDiMichele Жыл бұрын
Thanks for another great video Josué! Super helpful and clearly explained. I'll be using this a lot from now on!
@archicorner
@archicorner Жыл бұрын
You are welcome!
@wahidyuqob2016
@wahidyuqob2016 Жыл бұрын
Another fantastic video. I can compare your video to someone who is hungry and waiting for food. I had a similar project with "B" and "M" occupancy that I calculated, and when compared to your video, they do not require a separation.. Thank you again.
@archicorner
@archicorner Жыл бұрын
Glad you liked it!
@garrettriethman1873
@garrettriethman1873 Жыл бұрын
Literally just needed to learn about this for a project... and the perfect video was uploaded for it 5 hrs ago haha. Thanks!
@archicorner
@archicorner Жыл бұрын
Hope you enjoyed it! Talk about timing, haha.
@SerenaSmith-s1g
@SerenaSmith-s1g Жыл бұрын
Simple explanation and helpful!
@archicorner
@archicorner Жыл бұрын
Glad you think so!
@josephbradshaw7584
@josephbradshaw7584 Жыл бұрын
Do horizontal assemblies allow you to get around the requirement for the number of stories? Per chapter 2 a horizontal assembly is defined as "A fire-resistance-rated floor or roof assembly of materials designed to restrict the spread of fire in which continuity is maintained." The reason I ask is because I have a project I'm working on that's very similar to this video where we have an A-3 and B occupancy, but we got a comment back from the city saying we needed to provide fire separation between these occupancies per table 508.4. My project manager said we haven't had issues with this on past projects because use nonseparated occupancies. However, I double checked if our project meets all the requirements for nonseparated occupancies and it meets all of them, except we exceed the number of stories requirement by one... However, the code uses the word 'portion thereof,' when referring to the building, so that makes me think there are exceptions and you don't have to include all the stories if a story is separated from the other stories with a horizontal assembly? For reference, 508.3.2 says: "The allowable building area, height and number of stories of the building or shall be based on the most restrictive allowances for the occupancy groups under consideration for the type of construction of the building in accordance with Section 503.1. We also have a note on our plans that says "Level 1 is separated from upper levels by a horizontal assembly complying with IBC 711." So when CBC 508.3.2 uses the word ‘portion’ and we have a note about horizontal assemblies that makes me think we can exclude the first floor from the total number of stories requirement to meet this requirement?
@archicorner
@archicorner Жыл бұрын
This is a fairly complicated question to answer, but short answer is yes, if you have a horizontal separation between floors, and they meet specific requirements, it’s possible to consider the buildings as two buildings. One building on top of another building. This is often referred to as platform construction, and the building at the bottom has to be built as a specific building type, usually type IA. There are too many details to discuss but it’s doable.
@josephbradshaw7584
@josephbradshaw7584 Жыл бұрын
@archicorner The first floor is made of wood like the other floors above, and it's Type III-A construction, so maybe it doesn't qualify as a separate floor... So yeah, it's a complicated question, but I appreciate your response, and I'm a big fan of your videos.
@designereats3661
@designereats3661 Жыл бұрын
Very good! Keep making videos!
@archicorner
@archicorner Жыл бұрын
I am trying... more videos coming soon...
@darwishmajdi
@darwishmajdi Жыл бұрын
I literally die with the city of chicago reviews. Do you do consulting by means of sending you building department comments and you offering the best way to address city comments For example I have issues providing the correct UL numbers for a wall type
@archicorner
@archicorner Жыл бұрын
At this time, I don't take on consulting work. My apologies.
@Sandiegocruiser
@Sandiegocruiser 10 ай бұрын
are you in san diego
@doanpham972
@doanpham972 9 ай бұрын
I was corrected that a building is "sprinkled" in architecture school.
@archicorner
@archicorner 9 ай бұрын
True.
@hikolyou
@hikolyou Жыл бұрын
Great
@islam56898
@islam56898 Жыл бұрын
We need videos about acoustics in architecture
AC 033 - Accessory Occupancies - What are they?
11:26
archicorner
Рет қаралды 13 М.
How To Measure Building Height (AC-SHORT-001)
0:56
archicorner
Рет қаралды 4,5 М.
Chain Game Strong ⛓️
00:21
Anwar Jibawi
Рет қаралды 40 МЛН
Une nouvelle voiture pour Noël 🥹
00:28
Nicocapone
Рет қаралды 8 МЛН
To Brawl AND BEYOND!
00:51
Brawl Stars
Рет қаралды 17 МЛН
coco在求救? #小丑 #天使 #shorts
00:29
好人小丑
Рет қаралды 118 МЛН
A&M-SA Fall Commencement 2024, College of Arts and Sciences
2:08:50
Texas A&M University-San Antonio
Рет қаралды 2,7 М.
Air Canada eUpgrades Explained
15:47
Prince of Travel
Рет қаралды 75 М.
AC 047 - Fire Extinguishers
13:32
archicorner
Рет қаралды 4,9 М.
Joint Tenancy VS Tenancy in Common: What's the Difference?
5:57
US Realty Training
Рет қаралды 35 М.
Gemini Call Feature Focus 8 October 2024 - Pietro Negri and Tommaso Cesati, SC NODE
12:20
AC 021 - Stair ADA and IBC requirements
17:25
archicorner
Рет қаралды 36 М.
AC 028 - What are Dead End Corridors and how to avoid them?
6:49
Chain Game Strong ⛓️
00:21
Anwar Jibawi
Рет қаралды 40 МЛН