Carrier ac keeps freezing up, customer has to run the ac in the winter because of high heat load. I find high static pressure and other problems.
- Purchase your tools at www.trutechtoo... and use the offer code SURVIVAL to save 8% on your total purchase (exclusions may apply) -
- TOOLS I USE -
FULL LIST ON THIS PAGE - kit.co/hvacrsu...
💥 Amazon Store: www.amazon.com...
SHORT LIST IS BELOW
RIDGID 31305 Model E-110 9.5" Offset Hex Jaw Pipe Wrench - amzn.to/3Bar08y
Klein Tools Ratcheting Box Wrench 1/4 x 5/16 amzn.to/3GOpBrG
KNIPEX Tools - 10" Pliers Wrench amzn.to/3U7RRJf
KNIPEX Tools - 10" Cobra Water Pump Pliers amzn.to/3Wje8Wn
Knipex Tools - Mini Pliers in Belt Pouch amzn.to/3WguyyH
KNIPEX Tools - 4" Cobra XS Water Pump Pliers amzn.to/3UaQiKA
Bahco -6" Wide Mouth Adjustable Wrench amzn.to/3sHIsMV
Bahco - 8" Big-Mouth Adjustable Wrench with Rubber Handle - amzn.to/3SPhDB7
Knipex - 9.5-Inch Ultra-High Leverage Lineman's Pliers amzn.to/3DTLJ2h
Klein Tools Diagonal Cutting Pliers with Angled Head - amzn.to/3zuBVJb
Klein Tools Stripper, Crimper Tool - amzn.to/3gQQ6Su
Klein Tools Wire Cutter and Wire Stripper - amzn.to/3Fs627W
Klein Tools Kurve Wire Cutters, Heavy Duty Wire Stripping Tool - amzn.to/3FseIuW
Klein Tools Heavy Duty Automatic Wire Stripper - amzn.to/3SQdZab
Klein Tools Crimping and Cutting Tool - amzn.to/3TPIgXU
Klein Tools Screwdriver Adjustable 4 to 8-Inch amzn.to/3Nl6KWz
IDEAL INDUSTRIES Digital Circuit Breaker Finder - amzn.to/3DoBFwm
Fluke 376FC AC/DC Clamp Meter with iFlex - amzn.to/3UaNyx2
Fluke 62 Max Industrial Infrared Thermometer - amzn.to/3SNdwWg
Fluke 902 FC HVAC True-RMS Clamp Meter - amzn.to/3Ws7OfB
Fluke 87V MAX - amzn.to/3U6Rlv9
Fluke Networks Pro3000 Tone Generator - amzn.to/3WedklG
Fluke - FLUKE-52 Dual Input Digital Thermometer amzn.to/3zwFdf1
Ideal Safe-T-Grip Fuse Puller - amzn.to/3zsw2w4
Klein Tools Canvas Zipper Bag - amzn.to/3WgnJxq
Uni-Paint PX-20 Oil-Based Paint Marker - amzn.to/3sE3R9T
5 Gallon Bucket Topper and Organizer - amzn.to/3sGi2Ll
Stabila Magnetic Pocket Level PRO with Holster - amzn.to/3FtYLo0
Clip & Carry Kydex Multitool Sheath for LEATHERMAN SURGE - amzn.to/3TPJfHA
Kydex Multitool Sheath for LEATHERMAN WAVE & WAVE + PLUS - amzn.to/3sJlhlg
Cooper Atkins Thermistor Thermometer - amzn.to/3DLeHkC
GEARWRENCH Internal/External Ratcheting Puller 7 Ton 2 or 3 Jaw - amzn.to/3FxTU5l
- CONTACT INFO -
hvacrsurvival@gmail.com
- FOLLOW ME -
Instagram - / hvacrsurvival
Facebook - / hvacrsurvival
Warning Notice Disclaimer - Video content listed on the channel HVAC*R Survival is for entertainment purposes only and not meant to be a substitute for not contacting a competent HVAC/R PROFESSIONAL. Do not attempt anything said or seen on my videos, The tasks that are shown are dangerous and deadly without proper training.
This page contains affiliate links, which means that if you click on the link and make a purchase, I’ll receive a small commission. HVAC/R Survival is a participant in the Trutechtools, Amazon Services Associates Program.
#hvacrsurvival #hvaclife #hvacservice #hvacr #refrigeration #troubleshooting

Пікірлер: 64
@jsfkdkjslfdslfkdj
@jsfkdkjslfdslfkdj Жыл бұрын
Those switches last way longer if you add a relay for the fan and use the switch to break 24v to the coil
@topher8634
@topher8634 Жыл бұрын
I agree. You won't be switching as large of a load.
@tomoliver8498
@tomoliver8498 Жыл бұрын
You would think the little screw on switches would last longer when switching a relay but I have not had any better luck doing so. After 2 of them failed in a short period of time on the same system I installed a ranco like in this video. Been working fine ever since but I did leave the relay in the circuit.
@topher8634
@topher8634 Жыл бұрын
@@tomoliver8498 I don't like the encapsulated switches either. I think the repeated cycling just causes them to fail whether you use a relay/contactor or not. I usually use the Ranco switch combined with a relay for small motors and a contactor for the larger motors. If the motors have sleeves instead of ball bearings then I try to sell the ICM head pressure control kit. Some customers don't want the extra cost even after you explain shortened motor life to them. 🤷‍♂️
@HVACRSurvival
@HVACRSurvival Жыл бұрын
I agree 💯👍👍
@liam3284
@liam3284 Жыл бұрын
A heat recovery system would do great there, madness there is no economizer.
@jerzyaheardz6939
@jerzyaheardz6939 Жыл бұрын
Personally a fan of ICM 333 with the pressure transducer for low ambient fan control back when I was doing HVAC service, used to carry a few for situations like this
@HVACRSurvival
@HVACRSurvival Жыл бұрын
We use the Total Line version from Carrier 👍👍
@jasonjohnsonHVAC
@jasonjohnsonHVAC Жыл бұрын
I like those ICM fan speed controllers...i tend to not use that thermistor that it comes with, and i usually install the optional transducer. Hopefully its a ball bearing motor and not sleeve bearings. Great video as always Rick The vinyl tubing is a great trick to keep from rub outs
@HVACRSurvival
@HVACRSurvival Жыл бұрын
We use the Total-Line version, usually these motors are cheap sleeve beings.
@HughesManHVAC
@HughesManHVAC Жыл бұрын
Great vid Rick!
@HVACRSurvival
@HVACRSurvival Жыл бұрын
Thanks Ryan🤙
@natepeterson7145
@natepeterson7145 Жыл бұрын
Dewperheat for superheat bubcool for subcool per hvacr school, another way to remember glide
@HVACRSurvival
@HVACRSurvival Жыл бұрын
I like that 👍👍. Whatever makes it easiest for somebody to remember is good with me 🤜🤛
@WaffleStaffel
@WaffleStaffel Жыл бұрын
I have a 28 year old Coleman in a manufactured home. It's on life support, and I'm doing manual defrosts, as we're in the PNW and defrost is only needed maybe 15 days out of the year, and I don't like to run the heat strip. A recent snow storm knocked loose the wires I was using to operate the fan and reversing valve from inside, and I was unable to stop the fan for one night, so the coil only half defrosted. Too late to make a long story short, but even with a half inch of ice obstructing all airflow, I guess the heat of the compressor was enough to satisfy, because it wasn't running continuously. This thing has taken a fair amount of abuse and kept running nicely. I won't be too heartbroken if it gives up the ghost, because I'll be able to install a mini split.
@stevencossaboon3237
@stevencossaboon3237 Жыл бұрын
Nice work Rick. Thank you for the knowledge.
@JoseRodriguez-xh6qo
@JoseRodriguez-xh6qo 4 ай бұрын
Bad ambient control causes ice freeze up traditional ambient control recommended.
@Eddy63
@Eddy63 Жыл бұрын
Nice little vid Rick ... Thx for posting ...
@sterlingarcher46
@sterlingarcher46 Жыл бұрын
Over here they have kind of a plastic " serpentin " which is almost like a piece of vinyl tubing but cut in a way that you can wrap it around a capillary tube very easily , and it protects it just as good . It kinda wraps around the cap tube like a cobra snake wraps around its prey , just to illustrate the idea . I don't know what the make is or if there even is a part number for it though ...
@HVACRSurvival
@HVACRSurvival Жыл бұрын
I'm pretty sure I know what you're talking about. You see it more with electrical wires
@thestallion504
@thestallion504 Жыл бұрын
Can you do your MB3 bag setup please? =)
@scrambler350
@scrambler350 Жыл бұрын
Those capsule switches are just a callback waiting to happen - best to just change them out with an old mechanical switch like you did.
@HVACRSurvival
@HVACRSurvival Жыл бұрын
Thanks Mike🤜🤛👍👍
@scrambler350
@scrambler350 Жыл бұрын
@@HVACRSurvival Used to change the ones out on the units at our local 911 Dispatch annually - now I have them all changed out to the oldschool refer controllers. The capsule ones are definitely quicker to install, but you'll just be back switching them out - especially down here where they're off and on 90% of the time....very few days of sustained cold weather.
@koreylee611
@koreylee611 Жыл бұрын
Awesome video thanks for posting.
@marvinsellers4457
@marvinsellers4457 Жыл бұрын
Better safe than sorry my man it’s the little things sometimes that saves you Heart ache
@HVACRSurvival
@HVACRSurvival Жыл бұрын
Very True~
@Bobherry
@Bobherry Жыл бұрын
Nice video.
@JuanTodoli
@JuanTodoli Жыл бұрын
That Telesin collar seems pretty decent to hold the camera judging for your videos so far. Thinking in buying one 🤔
@HVACRSurvival
@HVACRSurvival Жыл бұрын
It also helps having the latest go pro 11
@JuanTodoli
@JuanTodoli Жыл бұрын
@@HVACRSurvival I have the 8 black and the stabilization booster is powerful.
@zekenzy6486
@zekenzy6486 Жыл бұрын
Great Video. Thank you for sharing. Is that low pressure switch you replace ? what is do for AC of that unit ? I saw it on refrigeration unit ? How set up differencial and pressure ? I'm new to hvacr
@HVACRSurvival
@HVACRSurvival Жыл бұрын
The switch I removed was a switch designed to close on a rise in pressure and open on a drop on pressure. They refer to it as a fan cycle switch, but it can be used for different applications. The purpose is to build pressure on the high side so that the metering device can maintain a normal suction saturated temperature above freezing. Set can be done different ways but essentially you want to keep your suction saturated temperature above freezing.
@Kangenpower7
@Kangenpower7 Жыл бұрын
The style of fan cycling switch that you removed looks like it is rated at about 1 amp, or pilot duty, and should have a 24 volt coil that is energized by that fan cycling switch to actually power the fan, thus it can last many years. I would rather have the control you installed, good for about 15 - 20 amps at 240 volts, so will also last for years. A word of caution, I had to replace a compressor on a small heat pump that had a fan cycling switch (looking at the furnace, you do not have a heat pump) and it was because the fan cycling switch kept the outdoor fan off in the heating mode. I installed a relay that was energized when in the heat mode, thus keeping the outdoor fan energized all the time in the heating mode (unless in defrost).
@HVACRSurvival
@HVACRSurvival Жыл бұрын
Thanks, yep, I've had to add a bypass relay to heat pumps with fan cycle controls in the past for the reason you mentioned👍👍
@topher8634
@topher8634 Жыл бұрын
@@HVACRSurvival I've had to do this too. Some forget that the condenser becomes the evap in heat mode. The ICM head pressure controls feature a heat mode override but I like those Ranco switches too. The sleeve bearing motors don't like short cycles though.
@jasonjohnsonHVAC
@jasonjohnsonHVAC Жыл бұрын
​@Topher yup...sleeve bearings need to spin at full speed to wick up the oil onto the shaft...then can slow down. The off/on with sleeve bearings will equal a short life span.
@HVACRSurvival
@HVACRSurvival Жыл бұрын
@@jasonjohnsonHVAC they can pay me to replace it, since they were the idiots that wanted this kind of system 🤣
@harrydickson4575
@harrydickson4575 Жыл бұрын
Nice job 👍👍👍
@JoseRodriguez-xh6qo
@JoseRodriguez-xh6qo 4 ай бұрын
69 degree temp will cause freeze up.
@MrAdamd83
@MrAdamd83 Жыл бұрын
The vrf systems is what that place needs
@HVACRSurvival
@HVACRSurvival Жыл бұрын
We have city multi systems at a few places but it's $$$$$, what they need is commercial equipment but these places cut costs everywhere.
@topher8634
@topher8634 Жыл бұрын
@@HVACRSurvival yeah they need a mixed air box and economizer at the least. It's ridiculous to be running mechanical cooling when it's cold outside.
@MrAdamd83
@MrAdamd83 Жыл бұрын
Where can I buy them brass tees like you used?
@jasonjohnsonHVAC
@jasonjohnsonHVAC Жыл бұрын
Any supply house. Called swivel tee's. Usually comes in a 3 pack ( JB branded )
@throttlebottle5906
@throttlebottle5906 Жыл бұрын
mmm, tasty pink cotton candy. I played in 36" deep white cotton candy last week, below that was 3/8" plywood, cellulose blow in and pink cotton candy sheets(bats) and of course I had to run wire middle of joist level in the mix of batts and cellulose. snow shovel, circular saw(plywood) and a lot of cussing. I've yet to quit itching and scratching from it 🤬🤬🤬
@HVACRSurvival
@HVACRSurvival Жыл бұрын
😂👍👍
@topher8634
@topher8634 Жыл бұрын
They using a fan cycle switch for R22?
@topher8634
@topher8634 Жыл бұрын
Never mind. Jumped the gun on the comment. My bad.
@HVACRSurvival
@HVACRSurvival Жыл бұрын
🤣👍
@jls1259
@jls1259 Жыл бұрын
are you close to east palestine where the train derailment is
@HVACRSurvival
@HVACRSurvival Жыл бұрын
Luckily no I'm in the north west corner, that was in the south east corner
@MrAdamd83
@MrAdamd83 Жыл бұрын
Do they have returns in each room
@HVACRSurvival
@HVACRSurvival Жыл бұрын
This only does the hallway.
@MrAdamd83
@MrAdamd83 Жыл бұрын
@@HVACRSurvival oh ok
@MrAdamd83
@MrAdamd83 Жыл бұрын
@@HVACRSurvival good job on that particular call I’ll get me some fan pressure controls put on my van asap
@specialK_hvac
@specialK_hvac Жыл бұрын
I'm curious what the parent company of this facility is, it looks quite familiar to me.
@specialK_hvac
@specialK_hvac Жыл бұрын
I saw in another comment you're maybe in the toledo area? I'm definitely thinking this is a Tril property
@HVACRSurvival
@HVACRSurvival Жыл бұрын
Not in Toledo, not sure who Tril is, but my videos are here to share and help others in the field, not start problems for my customers.
@steveblake8766
@steveblake8766 Жыл бұрын
194 thumbs up
@throttlebottle5906
@throttlebottle5906 Жыл бұрын
"Patient rooms" aka "Victim rooms"
@wonderhomie2011
@wonderhomie2011 Жыл бұрын
👍👍✅
@eastcoast186
@eastcoast186 Жыл бұрын
👍👍👍🇺🇸👀
Pocket Full of HVACR Band-Aids
25:45
HVACR Survival
Рет қаралды 12 М.
Old Condenser - New Location - New Compressor
18:36
HVACR Survival
Рет қаралды 10 М.
КТО ЛЮБИТ ГРИБЫ?? #shorts
00:24
Паша Осадчий
Рет қаралды 4,4 МЛН
Fake watermelon by Secret Vlog
00:16
Secret Vlog
Рет қаралды 6 МЛН
What will he say ? 😱 #smarthome #cleaning #homecleaning #gadgets
01:00
Why an Air Conditioner Coil FREEZES! Examples, Procedures, Troubleshooting!
11:34
New Trane Air Conditioner Dead On Arrival PLUS Lots Of PROMBLEM'S
25:00
My First Russell EXV Start Up!?
19:45
HVACR Survival
Рет қаралды 10 М.
AC Pressures, Subcooling and Superheat
29:52
HVAC School
Рет қаралды 258 М.
Warranty Coil Replacement On A 4 ton Ruud Heat Pump
40:27
HVAC GUY
Рет қаралды 19 М.
Heat pump 04 Accumulator & Muffler
7:25
Love2HVAC with Ty Branaman
Рет қаралды 20 М.
Semi hermetic Compressor Failure Replacement Procedure
24:02
HVACR Survival
Рет қаралды 9 М.
Freezer Too Warm / Stop Cutting Corners!
23:17
HVACR Survival
Рет қаралды 13 М.
КТО ЛЮБИТ ГРИБЫ?? #shorts
00:24
Паша Осадчий
Рет қаралды 4,4 МЛН