ACS Ventilation - More Than One Appliance

  Рет қаралды 2,494

Pass Your Gas

Pass Your Gas

Күн бұрын

Пікірлер
@CarlGuymer1
@CarlGuymer1 5 ай бұрын
Thank you! I passed my ACS at Brookehouse last Thursday....these videos you have made have helped me over the past year while I have been preparing for the exam.
@pro-powerflushing
@pro-powerflushing Жыл бұрын
Got my 5 years acs next month honestly you are very helpfull thanks so much for these videos 👍👍
@passyourgas
@passyourgas Жыл бұрын
I made them just for that! It’s so hard when you’re just doing one thing all day to remember the stuff you learned 5 years ago. Good luck and if you want anything let me know and I’ll make a vid. Cheers and thanks.
@pro-powerflushing
@pro-powerflushing Жыл бұрын
@@passyourgas you a mystery man I can’t see your name but yea it’s nice to see these videos I do mostly powerflushing not a lot of gas work so yes it slips my mind but then the 5 year thing comes round very quickly thanks again I’ve got more videos of yours to watch also 👍
@eazyrat
@eazyrat 2 жыл бұрын
found this channel just in time thanks!
@passyourgas
@passyourgas 2 жыл бұрын
You’re welcome. If you’re struggling with anything let me know and I’ll pop a vid up to help you!
@7magicful
@7magicful 10 ай бұрын
The room size of 30m3 is too small for 3.7kW flueless fire (3.7kW x 22.22 = 41.1m3) At Risk situation. But video is very helpful. Thank you. Love your channel.
@Михаиллеви
@Михаиллеви 2 жыл бұрын
Great video. 👍
@hvacgas5292
@hvacgas5292 2 жыл бұрын
Very helpful thanks 👍.. Would love to see vid how to read data badge for appliance working pressure, gas rate.
@passyourgas
@passyourgas 2 жыл бұрын
Thanks for that. I’ll stick an explanation of data badge reading up for you in the next week or so.
@zakariaalzubair6654
@zakariaalzubair6654 7 ай бұрын
thank you so much helpful
@tompfennell
@tompfennell Ай бұрын
What about if you have a DFE fire, what category is that?
@passyourgas
@passyourgas Ай бұрын
@@tompfennellBut this includes 35cm2 allowance for adventitious air. If you have another dfe, or open flue appliance in the room then it’s 135cm2 @@tompfennell Your gas book will explain it under ventilation. I hope that helps.
@passyourgas
@passyourgas Ай бұрын
@@tompfennell I don’t think all that I wrote came out …. It’s 100cm2. If the chimney has no throat, I.e if it’s under a canopy then it’s 50% of the case of the chimney.
@passyourgas
@passyourgas Ай бұрын
@@tompfennell case should read csa
@richardmcleod8604
@richardmcleod8604 2 жыл бұрын
thank you so much
@shredder8000
@shredder8000 2 жыл бұрын
Say u have a scenario, a flueless space heater in a 30m3 hallway, a 30kw gross warm air unit, no window but a door direct to outside, I’ve worked out both the fire & boiler need 100cm2 of ventilation each, can u add 2 categories together
@passyourgas
@passyourgas 2 жыл бұрын
If the warm air heater is also flueless it belongs in the same category as the fire so you add them together. If it’s open flued then it’s in a different category and you choose the one that needs most ventilation…cheers
@shredder8000
@shredder8000 2 жыл бұрын
@@passyourgas what about if they both come out the same, so they both require 100cm2, do u just pick 1 or add them both together,
@passyourgas
@passyourgas 2 жыл бұрын
@@shredder8000 Hi shredder…no, if you have two categories needing 100cm then you just use 100cm…you only ever use one category…remember these are MINIMUM ventilation requirements, you can put 200cm in if you want, as long as you don’t go under 100cm….hope that helps..
@shredder8000
@shredder8000 2 жыл бұрын
@@passyourgas ok kool, thank u 🙏
@abdulh63
@abdulh63 2 жыл бұрын
Hi, great video again. Wanted to ask, if I fitted a gas hob in a property and there was a boiler and a fire. What would a visual check on them require me to do, especially on the fire? Thank you
@passyourgas
@passyourgas 2 жыл бұрын
Hi Abdul. Thanks for the compliment. Re the visual checks, do you use the Viper book? If so it’s all on page M42. If not let me know and I’ll create a quick video for you…in fact I’ll be doing this anyway thanks to your question…
@abdulh63
@abdulh63 2 жыл бұрын
@@passyourgas thank you so much. I'm just wondering if you have to take the fire out and do a flue flow and spillage on a visual. I always assumed a visual is something quick and it seems a lot to do when you're only there to fit a hob. Would love a video on it, thanks again
@passyourgas
@passyourgas 2 жыл бұрын
@@abdulh63 It will be up by tomorrow for you. I’ll tell you straight off that you don’t need to do flue flows etc but there are 2 sets of rules depending on what you have done in the house…vid tomorrow.
@zabiullahkhorsand6757
@zabiullahkhorsand6757 2 жыл бұрын
30m3 not 30m2 = room size Thanks
@passyourgas
@passyourgas 2 жыл бұрын
Well spotted `zabiullah, a slip of the tongue, thanks for pointing it out. 😀
@Mark-fl1hg
@Mark-fl1hg 2 жыл бұрын
Also not pointed out, is that you would not be able to fit a 3.7kw flueless fire into a room of only 30 m3 volume. There is a maximum allowance of 45 watts per m3 of heated space (45x30), so the maximum heat input permissible for this appliance in this particular room, would actually be only 1.35 kW
ACS Essential - Flue Terminal Types Explained
17:30
Pass Your Gas
Рет қаралды 1,9 М.
ACS Essentials - Instantaneous Water Heaters
18:56
Pass Your Gas
Рет қаралды 3,4 М.
人是不能做到吗?#火影忍者 #家人  #佐助
00:20
火影忍者一家
Рет қаралды 20 МЛН
Мясо вегана? 🧐 @Whatthefshow
01:01
История одного вокалиста
Рет қаралды 7 МЛН
ACS Essentials - Tightness Test Pt1- Theory for Exam Questions
17:37
Pass Your Gas
Рет қаралды 3,2 М.
Tightness and Let-By Tests and Tracing Leaks
20:12
Pass Your Gas
Рет қаралды 3,1 М.
ACS Essentials Oven Safety Devices Vapour Pressure
14:39
Pass Your Gas
Рет қаралды 1,5 М.
Unsafe Situations. ACS Gas Essentials
27:11
Pass Your Gas
Рет қаралды 8 М.
ACS Essential - CPA How and Why
28:43
Pass Your Gas
Рет қаралды 4,9 М.
ACS Essentials - Regulations - How to Pass the Exams
10:58
Pass Your Gas
Рет қаралды 1,9 М.
Gas Rates Everything You Need to Know
29:16
Pass Your Gas
Рет қаралды 7 М.
ACS Gas Legislation Quiz 1
11:56
Pass Your Gas
Рет қаралды 3,5 М.
ACS Essential - Installation Sizing
13:55
Pass Your Gas
Рет қаралды 1,5 М.