How the Blower/Fan Relays on a Furnace Control Board Work!

  Рет қаралды 111,026

AC Service Tech LLC

AC Service Tech LLC

Күн бұрын

Пікірлер: 68
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
-Our E-book, Paperback, Workbook, Quick Cards, PowerPoints, www.acservicetech.com/store -Posters, Book, Workbook, Cards on Amazon: www.amazon.com/shop/acservicetech -Our E-book: play.google.com/store and iTunes and search "ac service tech" -Posters & PowerPoints on our Website: www.acservicetech.com/store -Spanish Paperback and E-book: www.acservicetech.com/libros-en-espanol -Thermostat Wiring Quizzes www.acservicetech.com/quizzes -Our Website has FREE Videos, Calculators, Podcasts, Articles, Tips, Quizzes, Q/A: www.acservicetech.com -Facebook Tips: facebook.com/acservicetech -Tools we use, Our Book, Workbook, and Quick Cards: www.amazon.com/shop/acservicetech -Join our updates list for an email strictly from us for new videos, articles, products and website features! www.acservicetech.com
@jaredcole1638
@jaredcole1638 3 жыл бұрын
Greatly appreciate these videos, especially to help refresh my memory or learn something new.
@simplyamazing880
@simplyamazing880 2 жыл бұрын
Great Video. I can't believe I found it about the very board I have questions about. Thanks for doing this.
@azmike1956
@azmike1956 2 жыл бұрын
Thanks for the verification. I must replace blower relay. Burned up when blower stator shorted to field windings. (2 year old motor POS!)
@DavidHernandez-gt9bo
@DavidHernandez-gt9bo 3 жыл бұрын
Very good troubleshooting ! Wiring simplified great videos !
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Glad you enjoyed it
@rickreeder3190
@rickreeder3190 3 жыл бұрын
Nice run through on the fan control board.
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Thanks Rick!
@scsclassics
@scsclassics 3 жыл бұрын
Nice video. If you have a defective relay should you just replace the relay or just replace the board with a new upgraded board that has a new relay ?? Is the cost efficient in difference to spend the extra money and just replace the whole board .
@tayzonday
@tayzonday Жыл бұрын
I can’t figure out how to control fan speed on my Rheem HVAC with a different board
@theadjuster151
@theadjuster151 9 ай бұрын
Same question for my new Bryant board! Let me know please when you find out 👊💯
@MsFishingdog
@MsFishingdog 3 жыл бұрын
Great video as always.
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Glad you enjoyed it
@NotKamalasBeach
@NotKamalasBeach 11 ай бұрын
Thank you for the instructions. My fan motor is turning off and on and I can hear a relay click as it keeps turning off and on. I put a voltmeter to the terminals and of course the needle kept jumping up and down every time it clicked. Would that be a bad relay or could it be something shutting the power off and on continuously to the relay?
@km4hr
@km4hr Жыл бұрын
Great video! Got any tips on how to check whether the output of an ignition coil is working? My furnace works fine if I ignite the burners by hand but automatic ignition is broken. How can I determine if I need to replace the ignitor (spark type) or if the control board, where the coil is mounted, is bad?
@jericosha2842
@jericosha2842 3 жыл бұрын
Fantastic and thorough explanation. While it's running do you use amp clamp to see if it is directing the current to the correct path?
@FarFromPar
@FarFromPar 3 жыл бұрын
This guy is one of the real ones.
@gotchaplumber
@gotchaplumber 3 ай бұрын
Great explanation.
@repairitdontwreckit4257
@repairitdontwreckit4257 Жыл бұрын
Another excellent informative video. Well produced. Thanks
@michaelinglis567
@michaelinglis567 11 ай бұрын
Quick question, i would really appreciate your input! Ive been building guitar tube amps and pedals and repairing old tube and solid state radios/receivers for years and ive also replaced our furnaces limit switch, inducer motor and one other part that i forget the name and purpose of (this was three years ago). And since those repairs ive had no issues until last night i noticed our inducer motor isnt turning off again. I also noticed our air filter was damp. So at first i was convinced they were related but now im thinking correlation doesn't equal causation here. I say that because i checked that the condensate line in now clear (using a shop vac) and then i turned my attention to the furnace. It wouldn't turn on but the thermostat was calling for heat but failing to get ignition. So i took the panel covering the pcb off and held the switch while i tapped the relay when it called for heat and that did the trick. So now im wondering if i can just pull the PCB and replace the relay with the same part number/relay type. Ive worked with relay switching on guitar pedals and i am quite familiar with how they function and how to design and circuit using them as well as how to properly remove and replace them without damaging the board. So my question is what do you recommend? Should i attempt to find a replacement board or should i pull the board and replace the relay? Also do those symptoms sound like they could be related to you, the wet filter and the furnace issues that is (with your wealth of experience i figure there could be something that those symptoms are telling you that i lack the experience to see). Thanks for reading and any help you can offer!
@izzymoney85
@izzymoney85 3 жыл бұрын
Like always thanks again for a great educational video appreciate it
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
So nice of you
@gideonlord-adem
@gideonlord-adem 3 жыл бұрын
Great video. How cab I become a great service Technician like you
@jacksarisun6640
@jacksarisun6640 2 жыл бұрын
Thanks so much. The video is very informative and educational.
@marvinlaird1971
@marvinlaird1971 2 жыл бұрын
I have that same circuit board on my Heil ac unit, I think my board may be dead because the little green LED on mine isn't flashing. I liked and subscribed. Please help! Thank you.
@ju7a
@ju7a 11 ай бұрын
Can you please make a video on connecting booster fan to blower so they run simultaneously?
@hamzahmohammad9918
@hamzahmohammad9918 3 жыл бұрын
Can you please do a video on how to solve a reverse polarity issue?
@hamzahmohammad9918
@hamzahmohammad9918 3 жыл бұрын
Like what to do when you get a code for that and where to start.
@RichardLukaszewski
@RichardLukaszewski Жыл бұрын
I have a Trane x95M furnace that was installed in fall of 2021. I have a two story home. The master bedroom is on the second level on the opposite side of the house where the furnace is located (in the basement). The master bedroom is 5-7 degrees warmer in the summertime and likewise cooler in the wintertime. I am thinking about installing a duct fan to boost the airflow into the bedroom. In the summer, I usually run the furnace fan continuously and in the winter I have the furnace fan on auto. I am thinking of using the EAC terminals to power a relay to control the duct fan. After listening to your video, it seem if I use the EAC terminals, I will not be able to operate the duct fan when I have my thermostat set for the funrnace fan to run continuously in the summertime. Does that make sense? Should I use a positive air flow pressure switch mounted in the plenum to control the duct fan rather then the EAC terminals. What method would you recommend?
@ronnyt9279
@ronnyt9279 3 жыл бұрын
Excellent vid 🙏🏽
@davidhazas7162
@davidhazas7162 3 ай бұрын
What causes relay to switch to cooling tap if fan is in on position at thermostat and calling for cooling? If they are both using the same relay.
@ctgcooltouch
@ctgcooltouch 3 жыл бұрын
Thanks ☺️☺️
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
No problem
@keyronwiley2003
@keyronwiley2003 2 жыл бұрын
I recently replaced a board that was burned up. The damage was isolated to the relay on the board. I replaced the board and made sure all my connections were tight. The unit works fine. What caused the board to burn up?
@johnoconnor8414
@johnoconnor8414 Жыл бұрын
He is very good
@wisdomwisdom817
@wisdomwisdom817 Жыл бұрын
Awesome job thank you so much
@scotth1946
@scotth1946 Жыл бұрын
Hi, I just installed a "smart" thermostat and it apparently doesn't support continuous low-speed fan. Seems like I should be able to make a connection at the furnace control PCB to have it run all the time on low-speed, and switch to the higher speed when heat or air comes on. How would I do this? Thanks!
@rrsttt7505
@rrsttt7505 Жыл бұрын
What if you have 2 zones controlled with dampers? When just 1 zone is running, I need it on Med-Low, otherwise it short cycles. But if both zones are going, it needs to be on Med-Hi or even High otherwise it takes forever.
@joseenciso5925
@joseenciso5925 3 жыл бұрын
U should make a video of a furnace that uses dpdt relays us new students really need those cause there is still homes out here that use those kind pleaseeeeeeeeee make a video on that we would all appreciate it that
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Here is a video on it, thanks- kzbin.info/www/bejne/a2a3kKuhbtmKjqM
@TheMaximomex
@TheMaximomex 3 жыл бұрын
So on cooling mode only R & Y are making contact and G is not making contact for the fan to run?
@jimbola77
@jimbola77 3 жыл бұрын
awesome Craig!!!! thank you again for sharing your awesome.
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
My pleasure!!
@Tito_hvac
@Tito_hvac 2 жыл бұрын
Helpful video 👍
@ronseasyfixjustdoit5098
@ronseasyfixjustdoit5098 2 жыл бұрын
Magic chef furnace contacts click to heat and cool but condenser is on but high speed blower won't turn on you can hear it stable once in a while
@stevenmishos
@stevenmishos 2 жыл бұрын
RE: "heat speed is usually used for your fan" (8:45) Is there a way to configure these boards so fan "on" (G) can use a different blower speed than the heat speed? It looks like I can wire red (low) to continuous fan, but, "any time you have power to the control board, you're going to have power over to the continuous fan" (3:17). Ideally I would like to be able to trigger red (low) only when the thermostat's fan "on" setting calls for it, so conversely, it's off when the thermostat isn't set to fan "on". The goal would be to have the heat speed running whatever is appropriate for BTU/CFM/pressure when heat is called for, but the fan would run on a slower speed simply to circulate the air between calls for heat (triggered from the thermostat).
@zekenzy6486
@zekenzy6486 3 жыл бұрын
Great Video. Thank you for sharing. If possible could you make video how to lubricate oil, grease on motor or hvac-r system . Thank you ^_^
@yourtravelpostcard
@yourtravelpostcard 2 ай бұрын
I can’t find the relay on my cepl131072-20 board pls help
@mikefetherling
@mikefetherling 10 ай бұрын
In this example, why isn't EAC powered along with Continuous Blower???
@justanotherguy9316
@justanotherguy9316 3 жыл бұрын
Thanks
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
No problem
@abdulhvac2395
@abdulhvac2395 3 жыл бұрын
Great thank you
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Welcome
@teldarion5277
@teldarion5277 2 жыл бұрын
Can someone explain to me the thing about voltage drop when your contactor goes bad ?
@steveodainfinite8894
@steveodainfinite8894 3 жыл бұрын
👍👍👍right on time
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
So glad!
@waynebunch2647
@waynebunch2647 Жыл бұрын
Good
@ctgcooltouch
@ctgcooltouch 3 жыл бұрын
My from Bangladesh
@ronseasyfixjustdoit5098
@ronseasyfixjustdoit5098 2 жыл бұрын
Magic chef condenser turns on but high speed blower won't go on fan stays on
@theadjuster151
@theadjuster151 9 ай бұрын
Time to change out that dinosaur 😅😂🤣🤣🤣👊💥💯
@andresperez5812
@andresperez5812 3 жыл бұрын
Can you put the Spanish translation of the videos please 🙏
@CarlosPerez-uu6ji
@CarlosPerez-uu6ji 3 жыл бұрын
Why don't we, spanish speaking people, make an effort and learn english? I don't see comments requesting the video to be translated to german, hindi,russian, portuguese,etc.
@theadjuster151
@theadjuster151 9 ай бұрын
​@@CarlosPerez-uu6ji👏👏👏👏👏👊💥💯
@HowToDoitright
@HowToDoitright Жыл бұрын
You make Excellent videos but the only bad thing is you do not answer most of the questions people ask which isn’t good.
@andresperez5812
@andresperez5812 3 жыл бұрын
Subtitles in Spanish please 🙏 🙂
@petersmith3489
@petersmith3489 Жыл бұрын
Q
@michealpatrick6217
@michealpatrick6217 3 жыл бұрын
Great Information as always!!
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Glad it was helpful!
How Defrost Works on a Heat Pump! Explained Step by Step!
7:55
AC Service Tech LLC
Рет қаралды 112 М.
Air Handler Heat Strips Not Working, Fan Blower Won't Turn On! Common Problems!
25:11
Бенчик, пора купаться! 🛁 #бенчик #арти #симбочка
00:34
Симбочка Пимпочка
Рет қаралды 3 МЛН
啊?就这么水灵灵的穿上了?
00:18
一航1
Рет қаралды 53 МЛН
pumpkins #shorts
00:39
Mr DegrEE
Рет қаралды 109 МЛН
Don't look down on anyone#devil  #lilith  #funny  #shorts
00:12
Devil Lilith
Рет қаралды 46 МЛН
Is the relay REALLY bad? | Understanding HVAC Electrical Concepts
24:59
How To Troubleshoot A Bad Control Board! Fan Wont Come On
7:43
The DIY HVAC Guy
Рет қаралды 59 М.
Bypassing a Furnace Control Board with a 90-340 Relay to get Blower Running
6:10
Apartment Maintenance Pro
Рет қаралды 22 М.
Gas Furnace Parts and Functions! Operation Explained!
18:46
AC Service Tech LLC
Рет қаралды 236 М.
Air Handler with Electric Strip Heating: Operation and Troubleshooting!
15:39
AC Service Tech LLC
Рет қаралды 442 М.
Furnace/AC How to Troubleshoot The Control Board
9:00
Word of Advice TV
Рет қаралды 872 М.
Troubleshooting Goodman Fan Control Blower Board
18:50
John Jennings
Рет қаралды 93 М.
Бенчик, пора купаться! 🛁 #бенчик #арти #симбочка
00:34
Симбочка Пимпочка
Рет қаралды 3 МЛН