I'm sure I've said it before, but thanks for all the great free information you and all the other great teachers provide. Such a wealth of knowledge. I'm 58 and I absolutely hated high school. Until I got into the trades. Then surprisingly I became an "A" student. I seriously love the trades and think its a great alternative to a four year college. My grand daughter is 15 and wants to become a welder. She makes me proud. Once again, thanks. Phil
@Tomkayanja4 ай бұрын
Thank for the video, the effort and time you put in make the world a better place to leave in.
@edwardlouie5 ай бұрын
I like using core depressors so I don't need to spin on/off quickly.
@Meenomack4 ай бұрын
This guy is a bad dude ! Always on point !
@kevinpearce32814 ай бұрын
I bought those probes. I don’t have the manometers yet tho. Some day I’ll get what I need to do my job properly.
@deanmartin19665 ай бұрын
Excellent video Craig. I do love my fieldpeace probes.
@pongobongo22955 ай бұрын
Use Appion charging tees. This is my go to charge set up. Also, get a third probe and map to outdoor air temp.
@electrolatif5 ай бұрын
The best aircon video in KZbin ❤
@yannkitson1165 ай бұрын
Great video, I have Testo probes and a slightly different app but it is all the same in the end :)
@paulrmfd5 ай бұрын
absolutely instructional keep up the good work
@kastenusa5 ай бұрын
Can you please make a video on where to connect probs on package unit correctly. Thank you!
@cryptkeyper5 ай бұрын
I second this
@kinstonboy13 ай бұрын
Supply & return duck lol@@cryptkeyper
@povoljan135 ай бұрын
The charging hose has air when you hooked it up to the tee. The small space after the shutoff valve is dead air space. Needs a better setup maybe?
@pbrewton3 ай бұрын
@acservicetechchannel Craig, correction to your statement: 75F as our *outdoor* dry bulb... 😊 8:47
@mohdrifi19305 ай бұрын
Excellent! You need to do this method to ac split unit also! Appreciate your effort teacher! ❤️❤️❤️❤️
@cryptkeyper5 ай бұрын
This is a ac split unit
@jericosha28425 ай бұрын
This doesn't work on mini split ductless if that's what you mean
@ludylopez33274 ай бұрын
😮It's advisable to charge luguid in suction side.
@NickNameNemo5 ай бұрын
If system has leakage (r410a) and still remains some amount of refrigerant, let’s say 70-80% of total, should I recover all refrigerant from system and charge it with new or just add needed amount?
@pitaeata84935 ай бұрын
need tips and tricks to determine if a system has a piston or txv. Sometimes on UNCASED coils it is impossible to remove the front of the field made cover to get a look.
@sir.cannabis11735 ай бұрын
I'm thinking one could tell by how fast the numbers move. Craig mentioned it might take 15 minutes for pressures to equalize with a fixed.
@mackenziegray20905 ай бұрын
If you see a threaded union outside the case, chances are you got a piston.
@turnedearthdesign86785 ай бұрын
Also check the chart on the condenser. It usually (but not always) tells you what the pressure of one of the lines should be which should match up to the metering device used
@craigmarshall404 ай бұрын
Great video thank you for spending the time
@Domopartner3 ай бұрын
great explanation thanks
@AndyHoltOutdoorUniversity5 ай бұрын
Nice job, Craig!
@justinhughes4525 ай бұрын
What was the recommended amount of refrigerant on the name plate? How much was in system at the start and what was the total amount at the rnd of this demonstration?
@x-got2bkidiny-justlikeabov7874 ай бұрын
Awesome explanation but … the label on the unit says indoor TXV with 10 deg F sub cooling. You say it has a fixed orifice so you’re using the superheat method - am I a missing something here?
@acservicetechchannel4 ай бұрын
Yes so the outdoor unit will always tell you the subcooling if a txv is used. However, as you can see through that plexiglass at the indoor unit, there is a piston there and not a txv. Single stage outdoor units can be installed with any combination of indoor units and metering device, thanks! To learn more check out our books at acservicetech.com !
@iamtheedrummer14 ай бұрын
Yeah I caught that
@gingerstrand61535 ай бұрын
Great video, thank you!!
@arthurrabon93495 ай бұрын
multi zone split unit question. if you have 3 zones and 1 zone is having troubles meeting set temp. how does system respond.
@carlossaenz40752 ай бұрын
Can I down load the calculation app ? And so what do need to do
@SocratesDionisius3 ай бұрын
What if we add r32 to r410 system. Let say we add 30% r32 into it?
@jorgemanzano72325 ай бұрын
Well explained! Thank you very much 😊
@zahedaminullah69345 ай бұрын
Great video man!
@TheWathever5165 ай бұрын
Great video!
@kennethlobo44205 ай бұрын
Well explained ❤
@repairitdontwreckit42575 ай бұрын
Thanks. Nice job.
@manueldacosta65395 ай бұрын
Excellent video as always, thank you.
@monstaro195 ай бұрын
We need a way to use this in cars its 106 in Florida
@lorunner12135 ай бұрын
Craig. Does the outdoor Dry bulb temp matter if being read from the sunny side of the condenser vs the shady side?
@edwardlouie5 ай бұрын
This method doesn't always work with inverter variable speed equipment that change the superheat target based on various logics.
@HVAC_Tips_Tricks_Calcs5 ай бұрын
Inverters usually don’t have fixed orifices.
@JoeSullivan-k6c5 ай бұрын
? What is the link for the brass tees to purchase sir. Thank You.
@JuanJuarez-en5xn5 ай бұрын
Can you make a video on RTU’S?
@mackenziegray20905 ай бұрын
It's the samething. What part confuses you?
@butlerstouchHVAC5 ай бұрын
great vid
@JuanJuarez-en5xn5 ай бұрын
Where can I buy those T’s that go on your probes do you have a link to them ?
@jimwhite94835 ай бұрын
How hard would it be for Fieldpiece to add a wireless input for ODDB in the app or on the SMAN 380V?
@turnedearthdesign86785 ай бұрын
You can link one of their psychrometer probes to the outdoor dry bulb
@jroberts34284 ай бұрын
I've been flooding alot of compressors 😳
@markniles30134 ай бұрын
We all do. Sometimes when your busy. Lol
@APHVAC09135 ай бұрын
Great video 👌🏽
@wpl119725 ай бұрын
I just use my valve core removal tool as my tee.
@emidiolopez14095 ай бұрын
So you remove the schrader valve to do SH or SC? Or what kind of removal tool do you use that has a press tool built in? Because the Appion that I use don’t have the press tool so I can’t take any risk of losing 5+ pounds of refrigerant by removing the schraders lol
@HVAC_Tips_Tricks_Calcs5 ай бұрын
@@emidiolopez1409if your loosing 5 lbs with a core removal tool you’re using it wrong. How much refrigerant are you going to lose I’d the schrader doesn’t seal?
@emidiolopez14095 ай бұрын
@@HVAC_Tips_Tricks_Calcs Ive never said I’m losing 5 pounds by using the schrader removal tool. I said that’s just stupid if you have to remove the schrader valves every time you have to check the pressures on an AC, NO way I’m taking risks in losing factory refrigerant if something doesn’t goes bad with the removal tool.
@davidlopan66495 ай бұрын
I can see myself pulling the pressure probes off the T and accidentally letting out all the refrigerant. lol definately would put a valve core on that for me.
@lorunner12135 ай бұрын
I use apion tee’s. They are low loss with schraders on both male ends of the tee. So doesn’t matter if you pull just the probe off. Or the tee with the probe.
@davidlopan66495 ай бұрын
@@lorunner1213 Yeah I love appion tools. Just purchased their recovery machine. I didn't get probes yet probably next year.
@JuanJuarez-en5xn5 ай бұрын
Where did you bought those T’s ?
@lorunner12135 ай бұрын
@@JuanJuarez-en5xnJohnstone Supply
@mtbbiker64015 ай бұрын
I don't understand how taking a low pressure (vapor line) reading at the condenser translates to the pressure in the evaporator. Why is it not industry standard to take low pressure (vapor line) reading at the evaporator?
@8799crosby5 ай бұрын
There is no ports at the evap .
@mtbbiker64015 ай бұрын
@@8799crosby So we are measuring total super heat temp using thermometer near the service port at the condenser (outdoor unit for heat pump) and measuring the pressure at the same service port to measure the temperature at the evaporator (indoor unit for heat pump). We measure pressure to convert to temperature. If we are measuring the temp and the pressure at the same spot, why don't the temp readings match? I'm trying to understand the physics behind this. Does it have to do due with saturation temp, sensible heat, latent heat?
@EricJohnson-dr5wb5 ай бұрын
@@mtbbiker6401good question. The pressure on the low side is essentially the same in the evaporator as it is at the low side service port. The vast majority of the cooling is due to the liquid to vapor phase change in the evaporator coil. The additional heating of the 100% vapor is the superheat. You want there to be some superheat to prevent liquid refrigerant from entering and damaging the compressor.
@9575434 ай бұрын
Because you want to be able to be in one spot
@globecomputers15 ай бұрын
Great video! Like always! Question can you provide a link for those AC test caps? I need to buy a set.
@HVAC_Tips_Tricks_Calcs5 ай бұрын
Just take two spare caps and drill a hole in them.
@HVAC_Tips_Tricks_Calcs5 ай бұрын
Although I’m sure sponsored, nice to see someone make a video that didn’t say you had to use MQ and True Flow or you’re a hack.
@tomaszpoznanski75845 ай бұрын
Iam a contractor and would like to do a course/training for a/c contractor. Can you recommend any in NY/NJ/PA area? Any schols?
@pana50755 ай бұрын
Espero este video en español
@vonboldler52195 ай бұрын
Hi mike!
@noname-cw5or4 ай бұрын
I thought this was a joke at first
@mikev.10345 ай бұрын
👍👍
@Mok-l5i5 ай бұрын
🙏🙏🙏🙏
@martinguzman43235 ай бұрын
👍👍👍👍👍👍👍👍👍👍👍👍👍
@var84925 ай бұрын
What if my liquid pressures are at 390 and suction 174 with a 11 t/s !??
@hazendismukesjr.83195 ай бұрын
😂why didn't you use a charging orifice
@YankeesFan745 ай бұрын
sadly most techs will hook up and immediately say it's good or needs refrigerant because companies are so focused on getting techs in and out as fast as possible. Most expect a complete diagnosis to be complete in 30 min max preferably less.
@TheRealDegen1005 ай бұрын
Preferably way less but every call is different. Only calls that really take time is determination of why a part failed.
@kevinpearce32815 ай бұрын
Why can’t you put the r410a into the liquid side if it’s coming in as a liquid
@davidgochenour70725 ай бұрын
It would push refrigerant into your bottle
@camilo8cheryl5 ай бұрын
High pressure
@FreonChugger5 ай бұрын
The liquid side is at a high pressure while the system is running. Connecting the refrigerant jug to the suction line, which is a lower pressure, will suck the refrigerant into the system.