AHU drain water over flow problem with solution | HVAC Training video | HVAC World

  Рет қаралды 53,030

HVAC World

HVAC World

4 жыл бұрын

Hell guys!!
HVAC se related choti SE choti problem ki video ham bana KR upload krte rhte jisse apko HVAC ki knowledge milti rahe
so plz
LIKE | COMMENT | SHARE | SUBS C R I B E
Keep Sharing - And Subscribe For More Updates...
If you are having any problem at site plz send video on ayanbabu133@gmail.com
we will come out to you with suitable solution
THANK YOU.

Пікірлер: 107
@yashavantkesare4417
@yashavantkesare4417 3 жыл бұрын
We also have same problem nd luckily i get ur video
@mdaafanhasan2651
@mdaafanhasan2651 4 жыл бұрын
You explained very well
@mohdhalimquraishi1364
@mohdhalimquraishi1364 2 жыл бұрын
Best video sir thank you so much
@mohammedkirmanisyed7960
@mohammedkirmanisyed7960 3 жыл бұрын
Awesome...Explanation. ..
@janibashamolla
@janibashamolla Жыл бұрын
Exlent explanation sir ji
@subhash6433
@subhash6433 Жыл бұрын
Sir thank u...sahi me bhi ye problem face kar raha hu. Abhi try karta hu
@HVACWorld
@HVACWorld Жыл бұрын
Problem rectify ho jaye to btana
@subhash6433
@subhash6433 Жыл бұрын
@@HVACWorld ok sir.
@ttrenterprisesonline6399
@ttrenterprisesonline6399 2 жыл бұрын
Right now good quality sir
@Panghal2017
@Panghal2017 3 жыл бұрын
Nice explanation
@fjiddimanijiddimani1663
@fjiddimanijiddimani1663 Жыл бұрын
Best explanation
@rezashahid7768
@rezashahid7768 4 жыл бұрын
Thanks so much sir
@RashidKhan-lr4fh
@RashidKhan-lr4fh 3 жыл бұрын
Great thanks
@shaikjuned712
@shaikjuned712 3 жыл бұрын
Thnq bhai
@satyamprajapati9064
@satyamprajapati9064 3 жыл бұрын
Nice explain
@birdsandnature8891
@birdsandnature8891 2 жыл бұрын
Excellent
@chrisshine3953
@chrisshine3953 3 жыл бұрын
Thank you...
@nagunagaraj5103
@nagunagaraj5103 4 жыл бұрын
Super super super explained 👏👏👏👏
@nagunagaraj5103
@nagunagaraj5103 4 жыл бұрын
FAHU also same solution? Please reply
@HVACWorld
@HVACWorld 4 жыл бұрын
Yes almost same solution....if you have any issues you can share with us with video we will provide exact solutions
@GovindSingh-wp7qi
@GovindSingh-wp7qi 3 жыл бұрын
Nyc bro
@abdulgaffoorriyazahmed7215
@abdulgaffoorriyazahmed7215 Жыл бұрын
Thanks
@mohsinsayyad4143
@mohsinsayyad4143 2 жыл бұрын
Haa sahi kaha sir
@taiyabansari5905
@taiyabansari5905 4 жыл бұрын
Nice video sir ji
@HVACWorld
@HVACWorld 4 жыл бұрын
Thank you
@IrfanKhan-ht8bv
@IrfanKhan-ht8bv 10 ай бұрын
Awesome 👍😎
@HVACWorld
@HVACWorld 10 ай бұрын
Thanks ✌️
@nareshkumar9218
@nareshkumar9218 2 жыл бұрын
Best video
@HVACWorld
@HVACWorld 2 жыл бұрын
Ok
@moideenyousaf3757
@moideenyousaf3757 3 жыл бұрын
also, the coil face velocity to be limited. the water shall be carried over when the face velocity go above 500 fpm
@raheeztp3158
@raheeztp3158 2 жыл бұрын
👍👍👍👍👍👍
@shashikumarkalledevar8433
@shashikumarkalledevar8433 2 жыл бұрын
Shall we provide inverted U trap if space is less below the unit..? And same formula applies there too?
@HVACWorld
@HVACWorld 2 жыл бұрын
No....
@sarojkumargouda3730
@sarojkumargouda3730 3 жыл бұрын
Thanks you sir for sharing the information
@nafisahmad001
@nafisahmad001 6 ай бұрын
G sir ye issue hamare project pe v hai
@shailendrapal5157
@shailendrapal5157 4 жыл бұрын
Agar AHU CFM jyada ho to bhi blower water Apni Taraf khinchta Hai or AHU ki CFM Pully size glt hone se jyada CFM Dene lgta hai
@HVACWorld
@HVACWorld 4 жыл бұрын
Exactly...good observation...
@ayankhamaru5449
@ayankhamaru5449 2 жыл бұрын
Sir what about the 15TR AHU drain pump discharge rating and drain pump specification.
@smsha6824
@smsha6824 Жыл бұрын
And also if ur are manually opening cooling actuator to 100 % then there will same issue as well as filters coil cleaning
@rakeshkaple3025
@rakeshkaple3025 4 жыл бұрын
Che line FCU connected hai inlet ka tem 7 deg.hai & outlet ka 20 deg celcius hai kya problem ho sakti hai.
@HVACWorld
@HVACWorld 4 жыл бұрын
Sare valve open hai ek baar cross check kr lo....sare valve open hai to strainer saaf karwa lo khol kr kachra jam gaya hoga strainer ki jaali me
@skhangamingyt2696
@skhangamingyt2696 2 жыл бұрын
I am facing Same problem with two FAHU please reply air band is a good solution for this problem or no
@HVACWorld
@HVACWorld 2 жыл бұрын
Plz check all things which mentioned in video
@spgelectrical8797
@spgelectrical8797 Жыл бұрын
Filter bhi shi hai u trap bhi shi hai fir bhi blower pani khich leta hai
@HVACWorld
@HVACWorld Жыл бұрын
Zyada static ka AHU hoga....iske liye double U trap bnana hoga..
@m4team825
@m4team825 Ай бұрын
drain se pani kench raha​@@HVACWorld
@HVACWorld
@HVACWorld Ай бұрын
@@m4team825 U trap ko AHU supplier k design k according banwao
@Islamkhan-xp5fw
@Islamkhan-xp5fw 11 ай бұрын
Water suction from drain line while u trap is also good what problem?
@rakeshkaple3025
@rakeshkaple3025 4 жыл бұрын
Hi sir
@HVACWorld
@HVACWorld 4 жыл бұрын
Hello
@hintertainment258
@hintertainment258 Ай бұрын
Drain bhee clear hai filter bhee clean hai fir bhee water leakage aarahi hai
@Makeapeacefulworld
@Makeapeacefulworld 11 ай бұрын
Problem exist after this. Any problem with drift elemintors instaaled in AHU
@dadakhan9084
@dadakhan9084 2 жыл бұрын
Assalamu ulaikum bhai ek baat bataw A.H.U ka return garam pani horaha h hamny sab valve chek krli h sabb opan h doosri baat h pani saf aara h aur pani sarkuling to horaha h fir Kia wajah h jo pani ritarn gram h
@HVACWorld
@HVACWorld 2 жыл бұрын
Msg me on whatsapp
@melvinfarnandis7585
@melvinfarnandis7585 2 жыл бұрын
@@HVACWorld sir WhatsApp number?
@kashifiqbalzafar
@kashifiqbalzafar 4 жыл бұрын
hello sir , how are you ?
@HVACWorld
@HVACWorld 4 жыл бұрын
Hello Kashif..I am fine
@kumardinesh1990
@kumardinesh1990 3 жыл бұрын
Isko chalu krne samay kya kya on krna para hai Bhaiya
@neerajkumaar4821
@neerajkumaar4821 Жыл бұрын
o humye Pattaya hi nahi thq
@blaisefernandes
@blaisefernandes Жыл бұрын
What if we use water pump to pump water after it reaches flood switch.even split until are using drain pump y u traps
@balajikumbhar6785
@balajikumbhar6785 Ай бұрын
Sir filter our u trap bhi oky hey phir bhi water lecage ho raha hey
@HVACWorld
@HVACWorld Ай бұрын
Send me video
@melvinfarnandis7585
@melvinfarnandis7585 2 жыл бұрын
After U trap also coming what is the reason
@drymindfitnessclub3848
@drymindfitnessclub3848 8 ай бұрын
Same problem h FAHU some time water leak in fahu duct
@chiragrana2733
@chiragrana2733 Жыл бұрын
How to calculate condensate drain water as per ton coil?
@mohdziauddin7711
@mohdziauddin7711 Жыл бұрын
Sir AHU ke vibration ko kaise control karte h????
@mirzaahmedalibaig9273
@mirzaahmedalibaig9273 3 жыл бұрын
Sir in my ahu statistics pressure 1058 how to calculate c.f.m 13929 pls tell me how find out drain fixed
@melvinfarnandis7585
@melvinfarnandis7585 2 жыл бұрын
From static pressure we cannot measure need take travers
@javidahmad9099
@javidahmad9099 4 жыл бұрын
Mare sat Roz ati hai .but mujha lagta hai ki humidity se water ata hai .aj u trap check karta hu
@HVACWorld
@HVACWorld 4 жыл бұрын
Humidity se water ata hai but wo drain pipes se nikalta rhega....over flow kabhi nahi hoga.....pipe choke hota hai fr U-Trap proper nahi h to over flow 100 % hoga....zyada problem U-Trap ki ati hai
@javidahmad9099
@javidahmad9099 4 жыл бұрын
@@HVACWorld thank you sir
@midhunthulaseedharan5943
@midhunthulaseedharan5943 3 жыл бұрын
AHU water inlet and outlet line are show very high pressure. Why?
@rjvlog746
@rjvlog746 Жыл бұрын
BROTHER DRAIN SW AIR KHICHTA HAI FAHU KYA PROBLEM HO SAKTA HAI
@HVACWorld
@HVACWorld Жыл бұрын
Static zyada hoga or U trap proper nahi hoga
@rjvlog746
@rjvlog746 Жыл бұрын
@@HVACWorld pahile wahi sahi tha abhi air khichta hai lekin fahu ke inside drain me patla sa pipe dal diya hai to air band hogya hai lekin uska water bahut slow jata hai
@jaffarhussain5669
@jaffarhussain5669 3 жыл бұрын
What kind of insulation you talking about. Usually we dont put insulation on drain pipe
@mohammedkarim4790
@mohammedkarim4790 3 жыл бұрын
Sirji in my site more than 50 FAHU having same problem and U trap also ok and after changing new bag filter also water flooding and this problem coming in summer only and our Ahus running onVFD so the speed also varies so can u explain what are the causes except what you explain
@HVACWorld
@HVACWorld 3 жыл бұрын
All these are limited to channels members....if you have member ship then we will resolve it by what's app chat or call
@melvinfarnandis7585
@melvinfarnandis7585 2 жыл бұрын
Boss there is entering outside humidity reduce fresh air
@nasifmajeed7573
@nasifmajeed7573 2 жыл бұрын
Partially close the Damper to 50 or 60 % Summer time Humidity issues will be high due to this water over flow will be there and and you can feel Dryness while touching the chilled water cooling coil
@kiransubedi3763
@kiransubedi3763 6 ай бұрын
ये सब कर्ने के बाद भी सेम होरहाहे अब केया बजै हो सकता है पिलिज इसका सोलोषण बतादिजिए न सर🙏🙏🙏
@HVACWorld
@HVACWorld 6 ай бұрын
Send me videos on ayanbabu133@gmail.com
@kiransubedi3763
@kiransubedi3763 6 ай бұрын
जेसा इसभिडियो में भराहुवा हे सेम ऐसा ही भ्र जाताहे
@mrlee2691
@mrlee2691 2 жыл бұрын
Ahu off karne ke bat pani nekal ta he q sir plzz rpy
@AsadKhan-uh2dn
@AsadKhan-uh2dn 2 жыл бұрын
Assalam alaikum kaise hai bhai mai Pakistan sy hu or ap ki videos buhut knowledgeable hai ap apne WhatsApp number mujhe send kar di jiye
@yogeshkamboj4500
@yogeshkamboj4500 3 жыл бұрын
Sir abi bi ho rhi hai problem filter bi clean kr diye
@HVACWorld
@HVACWorld 3 жыл бұрын
Aap you trap check kro....height kya hai you trap ki. .jaisa maine drawing me btaya hai us method se install hua hai ya nahi
@mohammadshamstabrez2406
@mohammadshamstabrez2406 3 жыл бұрын
Sir same problem mer AHU me aa raha he
@HVACWorld
@HVACWorld 3 жыл бұрын
Jo points maine video me btai hai usko check kro fr btana
@user-pn1le2mn4t
@user-pn1le2mn4t 2 жыл бұрын
in english please
@waqasmuzaffar1027
@waqasmuzaffar1027 4 жыл бұрын
choke k matlab samajh nhi ayea?
@HVACWorld
@HVACWorld 4 жыл бұрын
Choke ka matlab jaan ho jana...pipe k andr kisi chiz k fasne se pani bahar nhi ata h to use chokhe bolte hai
@waqasmuzaffar1027
@waqasmuzaffar1027 4 жыл бұрын
@@HVACWorld thanks for the reply janab
@s4shamsi257
@s4shamsi257 4 жыл бұрын
Reply dain ge aap
@HVACWorld
@HVACWorld 4 жыл бұрын
Ofcourse...we are here for you guys only
@s4shamsi257
@s4shamsi257 4 жыл бұрын
Can you help me
@HVACWorld
@HVACWorld 4 жыл бұрын
Yes I will try my level best.... let me know your problem
@s4shamsi257
@s4shamsi257 4 жыл бұрын
@@HVACWorld Bhai Jan Khali like Kare gain Maine aik guzarish ki hai
@HVACWorld
@HVACWorld 4 жыл бұрын
Konsi guzarish??
@mirzaahmedalibaig9273
@mirzaahmedalibaig9273 3 жыл бұрын
But sir in my ahu almost same problem but EC motors fixed in supply return air using EC motor EC motor frequency can kept supply is 100% return air kept 60% to 80% in this motors frequency can change one more ahu is big size which the centre of cooling coil one more drain try fixed bottom drain connected centre drain try bottom link but here bottom try water is not drain due air taking from u trap but centre Darin tray water sucking fan motor due to 100% supply ahu motor pls suggest me if you give you whathapp number i can send you photos
@HVACWorld
@HVACWorld 3 жыл бұрын
facebook.com/100794634950757/videos/758529181554078/ This is my fb page we can chat over there...
@zahidvlogs277
@zahidvlogs277 11 ай бұрын
How to control AHUs ducting water drop?
U Trap in AHU Drain Line
9:49
Girish Shinde
Рет қаралды 33 М.
Who has won ?? 😀 #shortvideo #lizzyisaeva
00:24
Lizzy Isaeva
Рет қаралды 59 МЛН
버블티로 체감되는 요즘 물가
00:16
진영민yeongmin
Рет қаралды 120 МЛН
1 or 2?🐄
00:12
Kan Andrey
Рет қаралды 52 МЛН
Я нашел кто меня пранкует!
00:51
Аришнев
Рет қаралды 4,4 МЛН
AHU Coil Service Related TO  #hvac In Urdu/Hindi
5:43
HVAC TECHNOLOGY
Рет қаралды 3,7 М.
Water Coils Explained
11:57
MEP Academy
Рет қаралды 17 М.
AHU Chilled Water Piping Connections.mp4
11:51
Gaurav Kuntal
Рет қаралды 156 М.
HVAC Why AC Sytems Have Condensate Traps
6:07
The HVAC Hacker
Рет қаралды 114 М.
How to Properly Pipe a Drain on a Fan Coil
6:50
HVAC School
Рет қаралды 241 М.
Who has won ?? 😀 #shortvideo #lizzyisaeva
00:24
Lizzy Isaeva
Рет қаралды 59 МЛН