Thank you for sharing this interesting install. You mentioned that the property was highly insulated but very kindly showed the underfilled cavity.😉
@loving-plumbing5 ай бұрын
@@normanboyes4983 Thanks for watching 👍👍
@brotherjohnno5 ай бұрын
Great video, exactly what you said, a lot of us old sole traders out here waiting to take the step over to ASHP. Interesting to see how you are tackling it all. It looks like Viessman have taken a lot of the ball ache out of these installations by the components doing everything you need them to. I assume its an expensive lot of kit but it looks like they make an installers life a lot easier and that can only be a good thing for us all. Really smart looking job, well done. Look forward to follow up video, thanks.
@loving-plumbing4 ай бұрын
Thank you very much. I definitely feel like the Viessmann Vitocal is superior in design to most. Definitely makes life easier. Cheers for watching.
@richarddesilvoplumbingheat94623 ай бұрын
Great video and thanks for sharing 👍 Just wanted to ask why you didn’t opt for the indoor unit that has combined cylinder and control unit in one? - the 151A i believe? Cheers
@loving-plumbing3 ай бұрын
Thanks. Because it only holds 170 liters I believe and we had three bathrooms 👍👍
@griffithsheating4 ай бұрын
Nice job guys 😎
@loving-plumbing4 ай бұрын
Thanks. I found your own videos on the Vitocal really helpful 👍 Anything you would have done differently?
@ozzyozman15365 ай бұрын
Great job mate
@loving-plumbing5 ай бұрын
@@ozzyozman1536 thanks mate
@handle11962 ай бұрын
Great video. Can fill and flush valves be used on gas systems, too? Have you ever used vuessmann vitotrol 200 indoor influence to work with the weather compensation? Vaillant seem to recommend this with their ashp's and weather comp.
@loving-plumbingАй бұрын
Viessmann have just released a vitorol specific for the heat pumps that works alongside the weather comp. I'm hoping to try it soon!
@stevewells25365 ай бұрын
Great video, what temp do you design the rads for with it running on the same weather comp curve as the UFH?
@loving-plumbing5 ай бұрын
@@stevewells2536 Thanks. So it's 40c at -2.3C . I have dialed it down on the heating curve slightly. I was skeptical to be honest but seems to be ok so far. Wait till it's cold I guess! Be back with a blending Valve 🤣.
@loving-plumbing5 ай бұрын
Aiming for 20c room temps.
@stevewells25365 ай бұрын
Thanks, I’ve got a similar job coming up, might try the same thing and not use a mixer 👍
@loving-plumbing5 ай бұрын
@@stevewells2536 it worked out that way for me really because the underfloor heating the client requested was designed at the same temperature. In reality the underfloor heating should be more like 30c -2. Those aluminium panels at 150mm centers aren't the best. If I could have got 100mm centers in I would have probably used a mixer to lower the Temperature. Either that or upsize the rads even more. It's worth doing the maths 👍. Thanks.
@plumbertime5 ай бұрын
Did you get this job from viesmann. You do good work.
@loving-plumbing5 ай бұрын
@@plumbertime thanks. No you have to source your own jobs. But Viessmann will do designs from Plans sent to them.
@plumbertime5 ай бұрын
@@loving-plumbing nice, thanks for the info. I watch a lot of KZbin and it kills me that some of the not so good people have more views than the very best! Keep it up 👍
@loving-plumbing5 ай бұрын
@@plumbertime thank you very much. Appreciate that 👍.
@Football-rk3gn5 ай бұрын
You gone through it way quick do you have a diagram for the system
@loving-plumbing5 ай бұрын
@@Football-rk3gn you get a rough schematic but it's not necessarily specific to your system.
@adblocker27624 күн бұрын
Why do they have to emphasise SS like that?
@rogerfaulknershomefromhome44582 ай бұрын
Great money earner for some, but a total waste of money. Huge installation investment with little or any savings.
@Realworldnews2475 ай бұрын
Why not press fit
@loving-plumbing5 ай бұрын
@@Realworldnews247 Because soldering is for real plumbers 🤣