Can you show update on this pond? I would love to see how well this filter works after a few years.
@steeleslandscapesllc.thewa49028 ай бұрын
It’s been aging wonderfully
@steeleslandscapesllc.thewa49028 ай бұрын
April 22, 2024
@yvettestewart8002 Жыл бұрын
Great video! Question: I currently have two retrofit bottom drains with the air stone attached. Can i just attached my drains at the end of my grid? I'm trying to re-purpose instead of having to buy another set of airstones.
@steeleslandscapesllc.thewa4902 Жыл бұрын
We use 12” air stones or diffusers. I would not think it would work unless you salvage them and retrofit them into the lift tube
@yvettestewart8002 Жыл бұрын
@Steele's Landscapes , LLC. The Water Boss Yes, my retrofit drain would be at the end of the grid, opposite of the pump. I sent you a message on your website, hoping to get a return email so I can send you a drawing of exactly what I mean. Thx.
@steeleslandscapesllc.thewa4902 Жыл бұрын
@@yvettestewart8002 I can’t recommend any modifications as I only know of this system and it’s functionality.
@irietpeshkess6 ай бұрын
Hi: I am watching your YT video on Airlift suction grid and have several questions. I currently hoping to upgrade my pond (19 x 10 x 2.5) to a (19 x 10 x 4.5) with bottom suction grid. I plan to use 2” spokes on either 3” or 4” main pipe. I know that I can run a 2” system , but pondering about the 4” main section and Airlift… I will have to have an adapter from 2” to 4”. Which is not clear to me if it’s a good solution. Or I can have a 2” airlift. I could not find Cross adapter that is 4” to 2”. , but I can barely see you are using these in your tutorial video. Can you please send me the PN air description of the Cross 4” to 2” Slip part. Another question is how do you extend the Airlift below the Bottom of the pond ?? I only going to use the Airlift to circulate the pond water. , ie. the outlet of the A.L. Is submerged just below the surface. To spin the water towards the skimmer. I will appreciate your feedback. Thank you
@steeleslandscapesllc.thewa49026 ай бұрын
It’s a 4”x2” Sanitary Cross. Google PVC parts online or go to local plumbing supply store. The bottom of airlift tube is installed inside liner. Dig a hole before liner and form liner in hole then the lift tube
@growinginphoenix75852 жыл бұрын
This is super helpful! Thanks! I would love to see a similar walk through of an airlift up-flow bog filter system. Is it the same system of perforated pipes except with 12" of gravel instead of 6"? (i see 12" recommended a lot for bog filter depth) If the airlift has an under gravel suction filter on one end and an up-flow bog on the other does the 15'x15' rule still apply?
@steeleslandscapesllc.thewa49022 жыл бұрын
Ok cool ! I’ll do that . And yes keep size similar. I’ll get a video for you
@steeleslandscapesllc.thewa49022 жыл бұрын
I don’t used perforated pipe
@growinginphoenix75852 жыл бұрын
by perforated I mean holes drilled in the pattern that you talked about in the video. Sorry I'm not sure if you mean you don't use this hole pattern from the video or you don't use pipe that was manufactured with holes in it. I think I'm confusing my self now :/
@steeleslandscapesllc.thewa49022 жыл бұрын
@@growinginphoenix7585 same hole pattern but it’s upflow and we add a way to agitate the bog with air to help with clean out
@webservant-dan77572 жыл бұрын
You mentioned in the video that this filter will work up to 15'X15' pond. Would I need 2 filters for my 18 foot circumference round pond? I'll also be using a large Helix bio-mechanical reactor filter.
@steeleslandscapesllc.thewa49022 жыл бұрын
You could go up to 18’ diameter and still get good performance. We’ve gone up to 20’x15’
@webservant-dan77572 жыл бұрын
@@steeleslandscapesllc.thewa4902 Thank you so much Jason!😃
@bradvanders6507 Жыл бұрын
Great video. What size air pumps are you using per air stone? How many litres per minute?
@steeleslandscapesllc.thewa4902 Жыл бұрын
120L
@bradvanders6507 Жыл бұрын
@@steeleslandscapesllc.thewa4902 Thanks Jason. Did you design this system yourself?
@steeleslandscapesllc.thewa4902 Жыл бұрын
No , I can’t take credit. Mike White the pond wizard did
@bradvanders6507 Жыл бұрын
@@steeleslandscapesllc.thewa4902 I have read Mike’s article “So, you want a crystal clear pond”. He seems to indicate that 60lpm will generate 10,000GPh of suction, which is incredible. Are you using 120lpm per 15’x15’ area to get 20,000GPH of suction?
@steeleslandscapesllc.thewa490214 күн бұрын
I’m not certain but I oversized the air and using diffuser not air stone. I might try a smaller size air pump, I’ll let you know .
@webservant-dan77572 жыл бұрын
Would the airlift for this work using 2" pipe instead of 4" with a higher volume air pump?
@steeleslandscapesllc.thewa49022 жыл бұрын
No, we only use direct suction with 2” pvc pipe.
@webservant-dan77572 жыл бұрын
@@steeleslandscapesllc.thewa4902 Thank you again Jason! I guessed that the extra volume of the 4" manifold would be necessary for an airlift configuration. In order to keep the cost down of the pond I plan to construct next year, I had already decided to go with the suction method but thought I would ask as I have absolutely no experience with airlifts. Keep up the great work. Love your videos. I'm also a fan of Eric Triplett and Leslie has been so helpful in planning my project over the phone and via email.
@steeleslandscapesllc.thewa49022 жыл бұрын
@@webservant-dan7757 nice ! Get it built . Eric and Mrs. T re energized my passion for ponds . Keep it dialed