Medium Pressure Tightness Testing - ACS - Gas Training - Gas Meter Testing - Russell Holdsworth

  Рет қаралды 40,104

Allen Hart

Allen Hart

Күн бұрын

Пікірлер: 83
@Brijoolz
@Brijoolz 4 жыл бұрын
They are fairly common around Aberdeen. Many years ago I chased a ‘faulty’ boiler, a Vaillant if memory serves, which had an intermittent fault. Couldn’t get to the route of the fault. I didn’t do one basic check! After contacting the agent and attending site, we discovered that on light up, the inlet gas pressure dropped to about 9 mb for a few seconds. I hadn’t checked it previously. On checking at the meter box, it turned out the breather tube was kinked inside, and didn’t let the regulator ‘breath’ or operate quickly. This caused the dip in pressure. I’ve never forgotten the fault. Stick to the basic rules and follow procedures. Thanks for an informative video. Every days a school day!
@lesliecraddock
@lesliecraddock 3 жыл бұрын
Thanks for the video, they’re always put across in a really approachable way that makes it as easy as possible to understand (as easy as the gas industry is to understand!) All the best Allen.
@johnacky
@johnacky 4 жыл бұрын
Moved to Dublin from the UK, and had an issue with a medium pressure system. Had the nicest chap come from the gas board to get me out the preverbial. Turns out we were both avid fans of you. Keep up the top work.
@AllenHart999
@AllenHart999 4 жыл бұрын
You know how to make someone smile. Thanks so much for your kind words and support. ❤️
@王钧贤
@王钧贤 4 жыл бұрын
I’m a gas work at Australia under APA Very knowledgeable video for young workers Thanks
@AllenHart999
@AllenHart999 4 жыл бұрын
Glad you enjoyed it
@davidoshea1536
@davidoshea1536 4 жыл бұрын
Brilliant video 🔥👏. Thank you Allen and Viva training, very informative and very helpful. Hope to see more throughout the series.👍👊
@AllenHart999
@AllenHart999 4 жыл бұрын
Glad you enjoyed it!
@jpfrench1496
@jpfrench1496 3 жыл бұрын
Fantastic as always great vids Allen. Mp meters are quite rare down my neck of the woods. So only see them every 5 years in the training center. Good vid to refresh the mind!!!
@jamesf893
@jamesf893 4 жыл бұрын
What a great video really well explained. Only seen 1 out in the field myself. So great to have it thoroughly explained 👍
@AllenHart999
@AllenHart999 4 жыл бұрын
Glad you enjoyed it
@kevinwilliams1421
@kevinwilliams1421 2 жыл бұрын
I’m on my ACS this week and I know I’ve got to do this tomorrow
@paulrossiter9567
@paulrossiter9567 4 жыл бұрын
Cheers for the explanation from you and Russ ....brilliant knowledge, got a few of those MP set ups around our area. ⭐️⭐️⭐️⭐️⭐️
@metromikey1985
@metromikey1985 3 жыл бұрын
Great video and the questions asked at the end really helped to remember the information 👍
@gjmheating8857
@gjmheating8857 4 жыл бұрын
Why are there single and two stage regulators? Also would it be at risk if the carcass enter semi concealed meter box through the rear
@jonhsmith212
@jonhsmith212 4 жыл бұрын
Great video, thank you very much. It would be great if you could make a video about testing LPG installation and regulators, i.e. testing UPSO and OPSO, tightness test and let by test. Looking forward...
@KS-we8ov
@KS-we8ov 4 жыл бұрын
Very well explained Russ.... thanks 👍
@AllenHart999
@AllenHart999 4 жыл бұрын
Glad it was helpful!
@oiltec3369
@oiltec3369 4 жыл бұрын
Great video Alan and co , outside Belfast most towns are mp so great educational video for the trainees and us oldies also lol
@AllenHart999
@AllenHart999 4 жыл бұрын
Last time i seen one was on my ACS 😂
@fthplumber
@fthplumber 3 жыл бұрын
This was an acs question, what do you do if an MIV was not present?
@kevinwilliams1421
@kevinwilliams1421 2 жыл бұрын
I had it today on my ACS..I went with contact meter supplier and it was right
@fthplumber
@fthplumber 2 жыл бұрын
@@kevinwilliams1421 thank you
@jamesnicholls8601
@jamesnicholls8601 2 жыл бұрын
Well done Alan.
@peterhyatt6751
@peterhyatt6751 4 жыл бұрын
This stuff just makes me miss being out on the tools so badly lol. Can’t wait for the test centre to open back up so I can do my refreshers and get back into the industry
@AllenHart999
@AllenHart999 4 жыл бұрын
What have you been doing?
@peterhyatt6751
@peterhyatt6751 4 жыл бұрын
Allen Hart I used to be contracted to a housing association, I’m sure you know what they are like. I ended up hating boilers so much I went to work In the funeral industry, great job satisfaction but just not the same feeling as fixing an old persons boiler at 9pm. But with the likes of your videos and baxi, just makes me really miss problem solving. Keep up the videos mate, I like others truly appreciate them and only wish I had these when I first started learning, would have helped a lot!
@AllenHart999
@AllenHart999 4 жыл бұрын
@@peterhyatt6751 Thank you and good luck.
@heatpump8566
@heatpump8566 4 жыл бұрын
Great vid Allen 👍
@AllenHart999
@AllenHart999 4 жыл бұрын
Thank you very much.
@chazzlebazzle69
@chazzlebazzle69 2 жыл бұрын
I'm looking to upskill to medium pressure with the area I'm now covering has a lot of medium pressure installations.....can you advise how much & how long the training program would be please.
@bg563195
@bg563195 4 ай бұрын
Why would you need to use LDF on the Inlet anaconda after the test?
@andymav3023
@andymav3023 4 жыл бұрын
Great video Alan ....I recently seen a medium pressure meter with no toggle lever or button. Just wondering would that be tested as a normal low pressure system? It was definitely a medium pressure meter so got a little confused with it. I do have pictures lol
@fis30
@fis30 4 жыл бұрын
Hi, thanks for this, is there a reset button? thx
@80saiid
@80saiid 2 жыл бұрын
Thank you Really helpful 👍
@richardhodgson7443
@richardhodgson7443 4 жыл бұрын
Very helpful. Fab video. Thanks
@AllenHart999
@AllenHart999 4 жыл бұрын
Thank You. When are you starting the training? Thanks.
@richardhodgson7443
@richardhodgson7443 4 жыл бұрын
Allen Hart September 21st 😁 can’t wait
@Heatingandplumbing1
@Heatingandplumbing1 4 жыл бұрын
New towns like cumbernauld, livingston are full of high pressure meters..
@mohammadghaffari6760
@mohammadghaffari6760 4 жыл бұрын
Hi thanks for your video,i have enquiry in terms of purging and testing a PRS29/REGULAR ,could you more explain to me thanks .
@marka4706
@marka4706 4 жыл бұрын
Really good video good explanation thanks. Been a while since i seen one
@AllenHart999
@AllenHart999 4 жыл бұрын
Last time i seen one was on my ACS 😂
@keithbrueton
@keithbrueton 4 жыл бұрын
Super Allen and thank you
@AllenHart999
@AllenHart999 4 жыл бұрын
Thank You
@seandavis4288
@seandavis4288 3 жыл бұрын
At what pressure do you attach the monometer for the medium pressure test?
@Jehannum2000
@Jehannum2000 3 жыл бұрын
Your question doesn't make sense. It doesn't matter what pressure you attach the manometer. It matters what pressure you do the test at.
@gjmheating8857
@gjmheating8857 3 жыл бұрын
Nice video guys my problem is I always blow the water out the garage with the toggle valve surely there is a better way
@Jehannum2000
@Jehannum2000 3 жыл бұрын
Electronic gauge?
@kennydonnelly35
@kennydonnelly35 4 жыл бұрын
Alan correct me if I’m wrong but that main ECV is falling to on 😮
@kennydonnelly35
@kennydonnelly35 4 жыл бұрын
Sorry just watched the rest of the video 😂😂😂
@AllenHart999
@AllenHart999 4 жыл бұрын
Kenny Donnelly Yes that’s absolutely correct, Well spotted. It talks about it in the video. Thanks
@AllenHart999
@AllenHart999 4 жыл бұрын
Thanks for watching 👍
@TheDickPuller
@TheDickPuller 4 жыл бұрын
That was a distraction for me too Kenny, but thankfully it was explained👍👍
@davidb2464
@davidb2464 3 жыл бұрын
Hi Alan, these are good points, but I work over in NI where (nearly everything) is MP, I'm sure the regulator brings the pressure down to about 26 (ish) mB. Also, did I see it right that the let-by was done at 0mB, or was he just muddled? Let-by's are done at 7-10mB?
@ashokrawal3820
@ashokrawal3820 4 жыл бұрын
Great video. Thanks
@AllenHart999
@AllenHart999 4 жыл бұрын
Thank You
@jamesmackenzie9837
@jamesmackenzie9837 3 жыл бұрын
Good video mate, cheers 👍
@AllenHart999
@AllenHart999 3 жыл бұрын
Glad you enjoyed it
@mikediamondcoxon6556
@mikediamondcoxon6556 2 жыл бұрын
Exelent info thanx
@lukehodges4511
@lukehodges4511 2 жыл бұрын
I share this with Graham Hill (he works at MANCAT) he find this useful.
@AllenHart999
@AllenHart999 2 жыл бұрын
Thanks
@digitaria
@digitaria 3 жыл бұрын
Where is the Temperature Stabilisation test? Is there any reason why this was left out?
@kevinwilliams1421
@kevinwilliams1421 2 жыл бұрын
He kept saying leave it for 1 minute
@richardhodgson7443
@richardhodgson7443 4 жыл бұрын
Forgive the stupid question but what is the difference between low pressure and medium pressure tightness testing? Is it the size of meter and amount of gas coming into property?
@Jehannum2000
@Jehannum2000 3 жыл бұрын
The safety features on the medium pressure meter get in the way of tightness testing (Under Pressure Shut Off shuts off at let-by test pressures, so you have to reset it before & after let-by test). Lock-up pressure is lower; if there's no Meter Inlet Valve you have to do the test 2 mbar lower than normal to avoid lock-up.
@y2k42y2k42
@y2k42y2k42 4 жыл бұрын
Great video 👍🏾
@AllenHart999
@AllenHart999 4 жыл бұрын
Thank You
@kudospremier7415
@kudospremier7415 4 жыл бұрын
As a trainee i came across the medium pressure meter. However my engineer didnt want to remove the meter on a install, as he put it could cause problems. Is the procedure the same as removing E6/U6/G4? Even in training the temporary removable for hot works has never been discussed
@Jehannum2000
@Jehannum2000 3 жыл бұрын
The procedure is the same as for low pressure. Once the gas has left the regulator, it's at the usual 21 mbar pressure. The meter is just an ordinary meter.
@Fran-fv6pf
@Fran-fv6pf 4 жыл бұрын
I thought I'd subscribed weeks ago, but no no! Clicked on ya last night and think your content and work is honest and excellent. I see you have a future apprentice in your profile pic.... My 4 year old daughter kicked my liquid PTFE thinking it was glue 😜 Just one question please if you get time, just give a reply, please and thanks!! Baxi combi 600/800 range or Viessmann vitodens 100 range to heat normal 3 bed semi with 10 rads.... Which one should I go for?
@waitikubuliwaitikubuli6180
@waitikubuliwaitikubuli6180 4 жыл бұрын
Audio a bit low.thank you
@abdusshimla8255
@abdusshimla8255 3 жыл бұрын
Im trying bit i dodnt understand a wordof this hehe
@davidmarsden8868
@davidmarsden8868 4 жыл бұрын
Time he cleaned that gauge
@AllenHart999
@AllenHart999 4 жыл бұрын
Always one. 😂
@seandavis4288
@seandavis4288 3 жыл бұрын
At what pressure do you attach the monometer?
@ciaranmcgreevy4941
@ciaranmcgreevy4941 4 жыл бұрын
Good video .. But the mp tightness test is still as clear as mud 🤣🤣🤣
@AllenHart999
@AllenHart999 4 жыл бұрын
Ciaran Mcgreevy What didn’t you understand 👍
@ableskill
@ableskill 2 жыл бұрын
Lots of mumbling!! It would of been great if we could “ just” have test procedure showing from let by to tighten test with and without miv…. And maybe than put in the mumbling.
@sdbrogs
@sdbrogs 4 жыл бұрын
MIV *meter inlet valve
@AllenHart999
@AllenHart999 4 жыл бұрын
Thanks.
So Cute 🥰 who is better?
00:15
dednahype
Рет қаралды 19 МЛН
Tuna 🍣 ​⁠@patrickzeinali ​⁠@ChefRush
00:48
albert_cancook
Рет қаралды 148 МЛН
UFC 310 : Рахмонов VS Мачадо Гэрри
05:00
Setanta Sports UFC
Рет қаралды 1,2 МЛН
Medium Pressure Tightness Test - NGCFE
10:09
Allen Hart
Рет қаралды 16 М.
How to check working pressure of an appliance
7:47
Able Skills
Рет қаралды 28 М.
Gas Rates Everything You Need to Know
29:16
Pass Your Gas
Рет қаралды 7 М.
ACS Gas Training - Gas Rating - Plumber - Russell Holdsworth
19:21
ACS Gas Training - Installation Faults Q&A
26:53
Allen Hart
Рет қаралды 27 М.
Medium Pressure Metering  | Gas Tutorial
7:48
Universal Skills
Рет қаралды 4,5 М.
Medium pressure test video
6:19
37 Adventure
Рет қаралды 931
So Cute 🥰 who is better?
00:15
dednahype
Рет қаралды 19 МЛН