They are fairly common around Aberdeen. Many years ago I chased a ‘faulty’ boiler, a Vaillant if memory serves, which had an intermittent fault. Couldn’t get to the route of the fault. I didn’t do one basic check! After contacting the agent and attending site, we discovered that on light up, the inlet gas pressure dropped to about 9 mb for a few seconds. I hadn’t checked it previously. On checking at the meter box, it turned out the breather tube was kinked inside, and didn’t let the regulator ‘breath’ or operate quickly. This caused the dip in pressure. I’ve never forgotten the fault. Stick to the basic rules and follow procedures. Thanks for an informative video. Every days a school day!
@lesliecraddock3 жыл бұрын
Thanks for the video, they’re always put across in a really approachable way that makes it as easy as possible to understand (as easy as the gas industry is to understand!) All the best Allen.
@johnacky4 жыл бұрын
Moved to Dublin from the UK, and had an issue with a medium pressure system. Had the nicest chap come from the gas board to get me out the preverbial. Turns out we were both avid fans of you. Keep up the top work.
@AllenHart9994 жыл бұрын
You know how to make someone smile. Thanks so much for your kind words and support. ❤️
@王钧贤4 жыл бұрын
I’m a gas work at Australia under APA Very knowledgeable video for young workers Thanks
@AllenHart9994 жыл бұрын
Glad you enjoyed it
@davidoshea15364 жыл бұрын
Brilliant video 🔥👏. Thank you Allen and Viva training, very informative and very helpful. Hope to see more throughout the series.👍👊
@AllenHart9994 жыл бұрын
Glad you enjoyed it!
@jpfrench14963 жыл бұрын
Fantastic as always great vids Allen. Mp meters are quite rare down my neck of the woods. So only see them every 5 years in the training center. Good vid to refresh the mind!!!
@jamesf8934 жыл бұрын
What a great video really well explained. Only seen 1 out in the field myself. So great to have it thoroughly explained 👍
@AllenHart9994 жыл бұрын
Glad you enjoyed it
@kevinwilliams14212 жыл бұрын
I’m on my ACS this week and I know I’ve got to do this tomorrow
@paulrossiter95674 жыл бұрын
Cheers for the explanation from you and Russ ....brilliant knowledge, got a few of those MP set ups around our area. ⭐️⭐️⭐️⭐️⭐️
@metromikey19853 жыл бұрын
Great video and the questions asked at the end really helped to remember the information 👍
@gjmheating88574 жыл бұрын
Why are there single and two stage regulators? Also would it be at risk if the carcass enter semi concealed meter box through the rear
@jonhsmith2124 жыл бұрын
Great video, thank you very much. It would be great if you could make a video about testing LPG installation and regulators, i.e. testing UPSO and OPSO, tightness test and let by test. Looking forward...
@KS-we8ov4 жыл бұрын
Very well explained Russ.... thanks 👍
@AllenHart9994 жыл бұрын
Glad it was helpful!
@oiltec33694 жыл бұрын
Great video Alan and co , outside Belfast most towns are mp so great educational video for the trainees and us oldies also lol
@AllenHart9994 жыл бұрын
Last time i seen one was on my ACS 😂
@fthplumber3 жыл бұрын
This was an acs question, what do you do if an MIV was not present?
@kevinwilliams14212 жыл бұрын
I had it today on my ACS..I went with contact meter supplier and it was right
@fthplumber2 жыл бұрын
@@kevinwilliams1421 thank you
@jamesnicholls86012 жыл бұрын
Well done Alan.
@peterhyatt67514 жыл бұрын
This stuff just makes me miss being out on the tools so badly lol. Can’t wait for the test centre to open back up so I can do my refreshers and get back into the industry
@AllenHart9994 жыл бұрын
What have you been doing?
@peterhyatt67514 жыл бұрын
Allen Hart I used to be contracted to a housing association, I’m sure you know what they are like. I ended up hating boilers so much I went to work In the funeral industry, great job satisfaction but just not the same feeling as fixing an old persons boiler at 9pm. But with the likes of your videos and baxi, just makes me really miss problem solving. Keep up the videos mate, I like others truly appreciate them and only wish I had these when I first started learning, would have helped a lot!
@AllenHart9994 жыл бұрын
@@peterhyatt6751 Thank you and good luck.
@heatpump85664 жыл бұрын
Great vid Allen 👍
@AllenHart9994 жыл бұрын
Thank you very much.
@chazzlebazzle692 жыл бұрын
I'm looking to upskill to medium pressure with the area I'm now covering has a lot of medium pressure installations.....can you advise how much & how long the training program would be please.
@bg5631954 ай бұрын
Why would you need to use LDF on the Inlet anaconda after the test?
@andymav30234 жыл бұрын
Great video Alan ....I recently seen a medium pressure meter with no toggle lever or button. Just wondering would that be tested as a normal low pressure system? It was definitely a medium pressure meter so got a little confused with it. I do have pictures lol
@fis304 жыл бұрын
Hi, thanks for this, is there a reset button? thx
@80saiid2 жыл бұрын
Thank you Really helpful 👍
@richardhodgson74434 жыл бұрын
Very helpful. Fab video. Thanks
@AllenHart9994 жыл бұрын
Thank You. When are you starting the training? Thanks.
@richardhodgson74434 жыл бұрын
Allen Hart September 21st 😁 can’t wait
@Heatingandplumbing14 жыл бұрын
New towns like cumbernauld, livingston are full of high pressure meters..
@mohammadghaffari67604 жыл бұрын
Hi thanks for your video,i have enquiry in terms of purging and testing a PRS29/REGULAR ,could you more explain to me thanks .
@marka47064 жыл бұрын
Really good video good explanation thanks. Been a while since i seen one
@AllenHart9994 жыл бұрын
Last time i seen one was on my ACS 😂
@keithbrueton4 жыл бұрын
Super Allen and thank you
@AllenHart9994 жыл бұрын
Thank You
@seandavis42883 жыл бұрын
At what pressure do you attach the monometer for the medium pressure test?
@Jehannum20003 жыл бұрын
Your question doesn't make sense. It doesn't matter what pressure you attach the manometer. It matters what pressure you do the test at.
@gjmheating88573 жыл бұрын
Nice video guys my problem is I always blow the water out the garage with the toggle valve surely there is a better way
@Jehannum20003 жыл бұрын
Electronic gauge?
@kennydonnelly354 жыл бұрын
Alan correct me if I’m wrong but that main ECV is falling to on 😮
@kennydonnelly354 жыл бұрын
Sorry just watched the rest of the video 😂😂😂
@AllenHart9994 жыл бұрын
Kenny Donnelly Yes that’s absolutely correct, Well spotted. It talks about it in the video. Thanks
@AllenHart9994 жыл бұрын
Thanks for watching 👍
@TheDickPuller4 жыл бұрын
That was a distraction for me too Kenny, but thankfully it was explained👍👍
@davidb24643 жыл бұрын
Hi Alan, these are good points, but I work over in NI where (nearly everything) is MP, I'm sure the regulator brings the pressure down to about 26 (ish) mB. Also, did I see it right that the let-by was done at 0mB, or was he just muddled? Let-by's are done at 7-10mB?
@ashokrawal38204 жыл бұрын
Great video. Thanks
@AllenHart9994 жыл бұрын
Thank You
@jamesmackenzie98373 жыл бұрын
Good video mate, cheers 👍
@AllenHart9993 жыл бұрын
Glad you enjoyed it
@mikediamondcoxon65562 жыл бұрын
Exelent info thanx
@lukehodges45112 жыл бұрын
I share this with Graham Hill (he works at MANCAT) he find this useful.
@AllenHart9992 жыл бұрын
Thanks
@digitaria3 жыл бұрын
Where is the Temperature Stabilisation test? Is there any reason why this was left out?
@kevinwilliams14212 жыл бұрын
He kept saying leave it for 1 minute
@richardhodgson74434 жыл бұрын
Forgive the stupid question but what is the difference between low pressure and medium pressure tightness testing? Is it the size of meter and amount of gas coming into property?
@Jehannum20003 жыл бұрын
The safety features on the medium pressure meter get in the way of tightness testing (Under Pressure Shut Off shuts off at let-by test pressures, so you have to reset it before & after let-by test). Lock-up pressure is lower; if there's no Meter Inlet Valve you have to do the test 2 mbar lower than normal to avoid lock-up.
@y2k42y2k424 жыл бұрын
Great video 👍🏾
@AllenHart9994 жыл бұрын
Thank You
@kudospremier74154 жыл бұрын
As a trainee i came across the medium pressure meter. However my engineer didnt want to remove the meter on a install, as he put it could cause problems. Is the procedure the same as removing E6/U6/G4? Even in training the temporary removable for hot works has never been discussed
@Jehannum20003 жыл бұрын
The procedure is the same as for low pressure. Once the gas has left the regulator, it's at the usual 21 mbar pressure. The meter is just an ordinary meter.
@Fran-fv6pf4 жыл бұрын
I thought I'd subscribed weeks ago, but no no! Clicked on ya last night and think your content and work is honest and excellent. I see you have a future apprentice in your profile pic.... My 4 year old daughter kicked my liquid PTFE thinking it was glue 😜 Just one question please if you get time, just give a reply, please and thanks!! Baxi combi 600/800 range or Viessmann vitodens 100 range to heat normal 3 bed semi with 10 rads.... Which one should I go for?
@waitikubuliwaitikubuli61804 жыл бұрын
Audio a bit low.thank you
@abdusshimla82553 жыл бұрын
Im trying bit i dodnt understand a wordof this hehe
@davidmarsden88684 жыл бұрын
Time he cleaned that gauge
@AllenHart9994 жыл бұрын
Always one. 😂
@seandavis42883 жыл бұрын
At what pressure do you attach the monometer?
@ciaranmcgreevy49414 жыл бұрын
Good video .. But the mp tightness test is still as clear as mud 🤣🤣🤣
@AllenHart9994 жыл бұрын
Ciaran Mcgreevy What didn’t you understand 👍
@ableskill2 жыл бұрын
Lots of mumbling!! It would of been great if we could “ just” have test procedure showing from let by to tighten test with and without miv…. And maybe than put in the mumbling.