Thank you sir for very simple and clear explanation. This topic is normally avoided in African colleges and universities as they believe to be hard and confusing. May God bless you brother.
@robertoquinones38272 жыл бұрын
Yes we can use that type of AVR but u have to supply input voltage at L-N to get 240Vac from stator windings output voltage with excitation current of 3amps per 10secs.
@aslamsajjad886710 ай бұрын
Yes it is compatible.
@EdelSM4 жыл бұрын
for remote voltage adjustment potentiometer ay OK lng kahit more than 1watt, and mas better. but the resistance should be 1k as per the manual.
@gabornerimar20944 жыл бұрын
Tnx you sa video sir good bless and more power
@ELECTRICALPOWERGENERATION3 жыл бұрын
Sir did u suggest to install the 6 amps breaker on AVR output or not as u mention there is no Protection on AVR
@teloexplicaeldiamante2855 Жыл бұрын
MY AVR GAVE AT MAXIMUM RANGE, THE GENERATOR IS 220 V AND GENERATES 355 V. IT DOES NOT ADJUST BY THE VOLTAGE POTENTIOMETER. WHAT WAS DAMAGED?
@shuttlemarineengineering Жыл бұрын
What is the brand and capacity of the alternator?
@teloexplicaeldiamante2855 Жыл бұрын
IT IS A CARD EQUAL TO THE STAMFORD, BUT UNIVERSAL. MY QUESTION IS: WHAT COMPONENT WAS DAMAGED TO THE CARD SO THAT IT DOES NOT REGULATE THE OUTPUT AND IS AT MAXIMUM RANGE
@shuttlemarineengineering Жыл бұрын
@@teloexplicaeldiamante2855 Hard to know which electronic component gave up, but based on your info’s it’s on the regulation circuitry. But if fitted with remote V adjustment is suggest you check if it’s open or if connection from potentiometer to avr if not broken or loose. A loose remote V potentiometer also causes high V output. If no remote then AVR is defective. Thanks
@reymartmanablug29654 жыл бұрын
Very informative video sir.
@joeopilas524 жыл бұрын
The regulator of my 7.5 KVA generator has corroded and I want to replace it with a new AVR just like this SX460. I understand this is designed for a brushless generator which requires a smaller amount of current considering that the AVR is powering a slave generator which in turn supply a bigger amount of current to the exciter of the main generator. The way I look at it is that the voltages are just alright for my generator and the AVR. I just want to know if its 4A continuous current in the output is adequate to power the exciter field of my generator. By the way its exciter resistance is 6.9 ohms. Thank you very much and keep up the good post.
@teloexplicaeldiamante2855 Жыл бұрын
I HAVE AN AVR SX460 INSTALLED ON A 220V GENERATOR. BUT NOW IT IS GENERATING 360 V AND IT DOES NOT TAKE ADJUSTMENT BY THE VOLTAGE POETENTIOMETER. I ASK YOU: IS IT A PROBLEM WITH THE AVR CARD OR IS IT AN INTERNAL PROBLEM. BECAUSE THE CARD LOOKED GOOD
@shuttlemarineengineering Жыл бұрын
SX460 max input in 264V only and it’s receiving 360v and since this avr’s does not have fuses then your avr is probably gone. Check excitation V how high is it and from there you can confirm that you have a defective AVR. Damaged rotating diodes or burnt winding wont show a high voltage, instead it produces a very low V. Thanks
@kennethbuenaflor43727 ай бұрын
Hi ser How do you get over voltage of output 90v to 150v is that ok??
@franciscorabano80252 жыл бұрын
Sir.. mike pwedi nyo po ba magawan ng video yong sa load sharing at paralleling requirements para sa dalawa or more generators.. thanks
@goldgolden30042 жыл бұрын
Thank you so sir . Good bless you
@Musliperanto3 ай бұрын
What is the notmal output sir of the avr without load connected?
@shuttlemarineengineering3 ай бұрын
Voltage output of AVR without load has different values based on brand and capacity. Some has only 6vdc & some has 15vdc @no load. Whats important to consider is that the Voltage output is proportional to the loading conditions. I hope this answers your question. Thanks
@roderickmagpantay60394 жыл бұрын
Hi Can you discuss also AVR AS480 connection. thank you
@АлексейЛевченков-д4к4 жыл бұрын
i need an instrution manual for avr taiyo exu-61a .please if you have it send a link.
@kuyaerapshoo12563 жыл бұрын
Still compatible sx460 same as sx440 avr even 415volt. Am I correct Sir?
@shuttlemarineengineering3 жыл бұрын
Correct sir
@denboymechanic2 жыл бұрын
I have 375kva nta855-g1 genset for poultry use. .the problema low herts low l-l low l-n kw low and shot down engine. .what is the problem sir can u advice me what is the probs of my genset 365kva
@shuttlemarineengineering Жыл бұрын
It really depends on the engine shutdown protection naka install sa system. But based sa info mo sir, low Hz means mabagal andar ng prime mover kya low L-L and L-N din yan definitely. Check na lang ano issue sa governor, fuel lines or other mechanical parts that is causing the RPM nd ema meet rated. If its 4poles yan 1800rpm Im assuming 4 poles windings. Thanks
@justiceekong6116 Жыл бұрын
How can I convert maccalte AVR to work with Stamford AVR
@shuttlemarineengineering Жыл бұрын
What is the alternator output V rating and check nameplate what is the excitation V. From there it can easily be determined what brand and type of AVR can be used. Thanks
@crellyortilla11942 жыл бұрын
Thank you sir Mike God bless 🙏🙏🙏. Si undo ito
@shuttlemarineengineering2 жыл бұрын
God bless you too Undo, stay safe
@melalbano63513 жыл бұрын
Sir how about Generator control modules?
@ianmichaelluaton92433 жыл бұрын
What if sir there is no residual magnetism so it means the avr will not work? And how to restore the magnetism? Thanks
@shuttlemarineengineering3 жыл бұрын
No it wont if the residual voltage is not suitable for the AVR triggering V, restoring by field flushing. thanks
@rutchelgimeo13064 жыл бұрын
Sir ask lng ako kasi ung gen set namin I convert nmun sa manual need talaga palit an ang avr kasi digital ung original nya
@jovsd.i.yprojects3 жыл бұрын
Sir pwede va yan sa ref
@dharmeshdj58694 жыл бұрын
Make vedio on sensor wiring to interfacing board on Disel generater
@glennjayranjo55543 жыл бұрын
Sir my dianamo alternator 5kva pano daigram nga pagkabit ng AVR ata anong brand.... Salamat
@becongcabahug70163 жыл бұрын
Sir, need to reply to make more participant perhaps.
@theoryofeverything94394 жыл бұрын
Yes we can use but Only by using a step down transfer because as you see input voltage limit is 264 vAC and Alternator output (input for AVR) is 415 v. All other specifications are satisfactory like Excitation field resistance is above 15 (25 ohm in this case) and AVR output 75 vDC.
@Fakir-ck4nh4 жыл бұрын
CATERPILLAR AVR PRICE PLEASE?
@josec.eleccion93493 жыл бұрын
Good day engr. Anong schematic diagram ng ATS Pag connect sa generator. Salamat.
@franciscorabano80252 жыл бұрын
Pwedi po ba yong dalawang generator na hindi pareho ang rated power?
@shuttlemarineengineering Жыл бұрын
Pwede yan sir aslong as not too huge capacity difference, important to note na they should have the same hz and exactly the same V at whatever loading %. Thanks
@addiszemen16378 ай бұрын
Thank you so much
@rodeldurban45344 жыл бұрын
Sir very informative.. May narinig ako voltage droop san po makikita yan? Sa avr din po ba?
@shuttlemarineengineering4 жыл бұрын
Yes sir droop adjustment is located in AVR. Manufacturer has their own description on droop...you might see it as P/F, derating, AMP, PAR or sometimes even as a simple S. i hope makatulong sa iyo yang infos nyan sir. Thanks
@gaminglover96524 жыл бұрын
Hello po pwede po pa discuss as440, nag under voltage po kasi ang genset tapos bigla namamatay possble po ba na sa avr ang problem..thanks po
Sir good evening.. ask lng Po f pano malaman Ang pin input 220vng generator 12kva 4pins palitan ko Sana Ng AVR sx460 salamat po sana mapansin
@shuttlemarineengineering2 ай бұрын
@@JonielBantan-g9h good pm sir, terminal 7-8 input terminals. Tnx
@modestovillocillo48443 жыл бұрын
May board sa avr ba na para sa delta connection para sa 75kva na avr?
@shuttlemarineengineering3 жыл бұрын
Ilan line to line V sir and ilan leads alternator?
@ruelbajar88053 жыл бұрын
good day sir ask q lng po Sana alarm ng genset perkins 500kva BOC L1L3
@maribelmendoza55233 жыл бұрын
sir pwede ba gamitin ung avr sa generator pra sa submersible water pump.tnx
@shuttlemarineengineering3 жыл бұрын
As long as mag match yun input at excitation voltage/current ng avr and alternator
@maribelmendoza55233 жыл бұрын
@@shuttlemarineengineering mga ilang watts kelangan na avr sir
@maribelmendoza55233 жыл бұрын
irerekta na sa generator ung sir ok lng ba
@borjokworkz62732 жыл бұрын
Sir good day may generator po akong kinabitan ng AVR. GB170 po yung avr para po sa STC na mindong dynamo po. Ang problem po hindi po naaadjust yung voltage nya sa avr. Yung connection ko sa UVW ok naman po. Dun sa Dalawang Z po sinunod ko naman yung diagram base dun sa manual. Ano po kaya problem sir.? Thanks po
@shuttlemarineengineering2 жыл бұрын
Good day sir, yung mindong genset kasi basically brush type and walang exciter field and exciter rotor. Yung output ng stator na U-V-W dun din kukuha ng voltage input yun GB170 na avr, make sure tama yan, yun naman feed sa main field dadaan lang sa trio bridge diodes pra yung 3phase AC from a separate coil group ng stator papunta na main field maging DC volts, pero yung 1 line from stator daan muna sa avr terminals labels Z - Z pra ma regulate yun DC na feed sa main field. Kung maka download ka ng PDF ng manual then balikan mo itong explanation na ito mas maintindihan mo yan. I hope makatulong sa iyo sir. Stay safe
@raghavendragajapathy64764 жыл бұрын
Yes we can use.. Your videos are good.. Kindly share me some more videos about AVR .. Also i have seen few transformers inside alternators.. Please explain about that
@theoryofeverything94394 жыл бұрын
Only by using a step down transfer because as you see input voltage limit is 264 vAC and Alternator output (input for AVR) is 415 v. All other specifications are satisfactory like Excitation field resistance is above 15 (25 ohm in this case) and AVR output 75 vDC
@Adarsh198934 жыл бұрын
@@theoryofeverything9439 no need transformer.. Input voltage for avr coming from mid taped alternator terminals
@aiahamadumbayo16663 жыл бұрын
Is this avr 3 face
@andreyaparecidosilva13744 жыл бұрын
Presiso de legenda português excelente video
@andreyaparecidosilva1374 Жыл бұрын
Hoje eu consigo entender inglês ,💪💪💪💪💪quem diria ,,🫡🫡🫡🫡
@richardparacuelles36122 жыл бұрын
sir magandang araw po,, naka encounter ako sa generator namin ,na sira kasi yung voltage adjuster kasi sinusunog niya yung parang transformer ,,,ngayun wala na akong ibnag paraan oara mag adjust dun lang talaga sa avr mismo ,,,anu pong nang yari jan sir?
@shuttlemarineengineering2 жыл бұрын
Brand ng alternator mo sir?
@willymerlan45483 жыл бұрын
Sir meron po ako nyan baka po bibili kayo ..?
@theoryofeverything94394 жыл бұрын
Without transformer its impossible to use the AVR on this alternator
@shuttlemarineengineering4 жыл бұрын
Yes it’s possible...checkout my part 4 video. thanks
@becongcabahug70163 жыл бұрын
Boss paano e connect ang AVR sa three phase 220v generator? salamat
@shuttlemarineengineering3 жыл бұрын
Ano brand and model ng AVR mo sir, if 220V rated Voltage ng genset mo then madali lang kasi most of AVR naman has 180-260V input kya directly connected na sa any of the 2 lines.
@becongcabahug70163 жыл бұрын
@@shuttlemarineengineering i have a GAVR20A po.
@shuttlemarineengineering3 жыл бұрын
Ok yan, madami na tyo nakabit na GAVR pero 15 nde 20, magandang AVR yan, pra nga syang universal kasi mataas excitation current kya pde yan sa ibat ibang brands.
@becongcabahug70163 жыл бұрын
@@shuttlemarineengineering OK po sir, maraming salamat
@louiegalpo54133 жыл бұрын
boss pa order nman po need ko sa 3kva generator k0
@dawitarega7677Ай бұрын
Yes comateble
@protaciojrescarilla6199 Жыл бұрын
sir pwd ba makahingi ng contact no. mo, nag hahanap kz kmi ng mag bgay samin ng training
@shuttlemarineengineering Жыл бұрын
Kindly email us at perl.shuttlemarine@gmail.com and we’ll coordinate with you accordingly. thanks
@becongcabahug70163 жыл бұрын
incompatible po Sir
@shuttlemarineengineering3 жыл бұрын
Compatible yan sir, youll be guided sa mga ibang parts ng vlogs natin for proper connection. Thanks
@becongcabahug70163 жыл бұрын
Salamat po sir.
@kentbontilao13873 жыл бұрын
@@shuttlemarineengineering sr tanong lang po yong ginagamit ang dvr paano maa adjust yan at pag wiring? Pwede po bang palitan ang dvr to avr? Salamat po