Love these great for brushing up and refreshing the old memory at 30 🤣
@frankdunham60513 жыл бұрын
Hi Derek, I started doing my domestic gas at the start of this month and your videos are really helping me consolidate what I'm learning. Really good explanations and detail, keep up the good work, you're helping lots of people out there.
@英福星3 жыл бұрын
😁
@mgbroadsterJ Жыл бұрын
My analyser doesnt have a sweep test mode .
@darrenfrancis9172Ай бұрын
Hi chap, love the videos, really really helpful, keep them coming 👍👍👍 and thankyou for uploading them👍
@mj0n4id363 жыл бұрын
Nice explanations! First time I’ve seen someone actually flue gas analyse and explain the importance of doing so for other appliances too. Not just for combi boilers. Sweep test always seemed awkward for me but now having watching this video it has really helped. Thanks Derek 👍🏻. Asian Jon. Training.
@louisdisbury9759Ай бұрын
I notice you analysed the boiler with the boiler cover on which on final commissioning is correct, Many Engineers analyse with the cover off forgetting that the boiler is drawing in air from the room and not through the flue which is crucial to safe operation of the boiler back in the day as you know ff boilers rarely operated with the cover off so by alll means carry our analysing the boiler with the cover off while commissioning and making adjustments but all ways carry out final analysing with the boiler cover correctly fitted to ensure correct operation of the flue.
@michaelrose50404 жыл бұрын
Great video really helpful for my ACS Thanks Derek
@helendavies9234 жыл бұрын
Really thorough and informative. Thanks, Derek!
@brenndonherbert45833 жыл бұрын
Brilliant video as always. Thanks for the amount of depth that you went into, gained a great amount of knowledge from that.
@monikanader94543 жыл бұрын
Great video, very informative. Thanks Derek 👍👍👍
@jockster55252 жыл бұрын
Quality mate really useful video as are all your videos .. absolute star 🌟
@naturelover_92114 жыл бұрын
One more great video thank you Derek.
@rivkiroyde43624 жыл бұрын
Thanks Derek great video👍👍👍👍. Benny
@qmob0121 Жыл бұрын
Hotly would you test a top oven/ grill combi grill side ? In the same way you do the ovens or is there a another way to use the 7 hole probe to do it ?
@dagnallcadarngaming74132 жыл бұрын
Great video. Can I ask where the flue integrity readings you quoted are found as in what documents please as I’m struggling. Thanks in advance.
@albyhendriks40242 жыл бұрын
Great information
@lostinthoughtscalminsilenc81673 жыл бұрын
Great video
@bernardgatdula90943 жыл бұрын
One day please discuss about the electrical system of Bosch Gas Range Thank you.
@samchappell2333 жыл бұрын
👍👍👍 great video!
@dimitardimitrov33003 жыл бұрын
Hi Derek. You are high level teacher and your way to teach is great. You speak so calm and friendly. We all appreciate this. Your videos helped me to improve my knowledge and understanding for my initial ACS. But on my ACS(which I still need to complete) they asked me to gas analyze the cooker hobs and they insist to go and do it. I needed to fill in the readings in the paper too. What will you advice me in this case. I light up the four hobs and hold the analyzer about 30 cm over but I wasn't sure if I do the things correct. Thank you so much! Appreciate all your hard work to teach us!!!
@tomkatgastraining3 жыл бұрын
You don’t analyser the hobs on a cooker just the oven and grill separately. Not sure why they have asked you to do this as it’s not required unless you are carrying out a room test.
@dimitardimitrov33003 жыл бұрын
@@tomkatgastraining You are such a good man. Thanks for your help 🙏❤️
@lostinthoughtscalminsilenc81672 ай бұрын
Please do more back boiler videos
@ryandow39544 жыл бұрын
Brilliant video!
@zaygoodfellowofficial4 жыл бұрын
Informative Muhammad Faisal Abbasi
@whome58102 жыл бұрын
How long would the exhaust sample point have to be open to give higher CO readings in the room. Ie 50pp? Does how long this can be left open vary from boiler to boiler? It appeared that you left the exhaust sample point open while you were testing the air intake side, would this not raise levels of CO in the room? Anyway, great video!
@oneloveonelifeman4 жыл бұрын
Missing been down the center. Hopefully there soon!
@dkaloupis752 жыл бұрын
Procombi Exclusive 24 there is no chance to adjust the minimum or high settings. Any advice on that?
@ChelseaFC190512 Жыл бұрын
If there's no MIs like the older boilers then what do you refer too
@paulrossiter95674 жыл бұрын
Brilliant video , thanks very much for the in depth recap. I don’t like my Kane anymore after seeing yours 😂
@darrenclarke1614 жыл бұрын
Great info 👏👏👍
@paulmilton61234 жыл бұрын
Thanks great video's 👍👍
@abchannel37374 жыл бұрын
You are the best
@Zinadene693 жыл бұрын
Hi Derek, I see you have shown how to test an inset gas fire, where you need the extension on the probe. What I would like to know is, are you able to demonstrate how to analyse a High Efficiency (HE) Inset Gas Fire, which come with a sealed glass front? (PS Great videos. Very helpful and informative) Stay safe
@tomkatgastraining3 жыл бұрын
Is it a balanced flue or fan flue or flueless fire
@vladimirstafasani46303 жыл бұрын
Excellent video love it. Is dynamic pressure same as inlet pressure or working pressure in the boiler? Thank you Derek
@tomkatgastraining3 жыл бұрын
Benchmark seams to have changed max pressure to dynamic pressure so I guess so 👍🏻
@vladimirstafasani46303 жыл бұрын
@@tomkatgastraining many thanks 👍
@darrensworkshop67838 ай бұрын
Hi Derek Do you have the facility to demo commercial kitchen appliances eg COMCAT1,3 and 5 and carry out a proper CP42 test? I teach this within my company but each engineer has their own way ....I teach using DW172 and IGEM/UP/19 standards.
@tomkatgastraining8 ай бұрын
Sorry mate we don’t have commercial kitchen at tomkat 😢
@farobenz61444 жыл бұрын
Hi What do they mean by initial and final combustion? Thanks
@garlic15584 жыл бұрын
Very good 👍
@raisapotoroaca40164 жыл бұрын
Morning Derek following your pipe bending tutorials do you think you can do some videos about pipe sizing as well It will be lovely to see how to measure correctly if it’s possible. Thank you very much and please stay safe!!!
@tomkatgastraining4 жыл бұрын
On the way soon
@aaronjoyce19803 жыл бұрын
Watched Aaron trainee 😁👍👍
@saheedk12 жыл бұрын
I love u so much
@RahulSingh-jn7py2 жыл бұрын
Does any one know the ratio of the open flued back boiler as in what it is and where i can find it?
@faroyoussef1757 Жыл бұрын
Sweep test with cover on ? Or cover off?
@tomkatgastraining Жыл бұрын
Sweep test is testing the covers seals so the cover has to be on
@sanjit414 жыл бұрын
Great one again,are you going to make video about flue/chimney?
@tomkatgastraining4 жыл бұрын
Sanjit grg in the to do box mate 👍🏻
@lissa0206094 ай бұрын
@tomkatgastraining so if someone had drilled a hole in the flue and it was only AR would it still be riddor because it had been done by a engineer that should know better 🤔 sorry not long started learning
@asbestosflake57493 жыл бұрын
Do same video but on a Worcester green star please.
@tomkatgastraining3 жыл бұрын
It’s on the to do list 👍🏻
@suheilhanna8733 жыл бұрын
Such an educational, 53CO 0.0006 ratio. is that normal on high setting, I thought CO should be below 30ppm . ratio 0.0004 or under?? .. Still training ...😊... you are a 5 💫💫💫💫💫
@tomkatgastraining3 жыл бұрын
For boilers your co could be up to 350 ppm and co2 of up to 10 .2 and a ratio of less than 0.004 depending on the boiler.
@ianferguson83674 жыл бұрын
brillant
@marvindallen89162 жыл бұрын
👍🏾
@l3thal3563 жыл бұрын
Anyone know the best place to put a flue gas analyser probe on an openflue boiler?
@tomkatgastraining3 жыл бұрын
Watch my other videos on analysing and you will find out 😜
@joaovittoria25333 жыл бұрын
👍👍
@mervinpermalloo8589 Жыл бұрын
🙏👍
@natugrmaxion83374 жыл бұрын
👍
@jon-paulward45802 жыл бұрын
Jon-Paul Ward
@craighurst35994 жыл бұрын
CH 👍
@matttate91552 жыл бұрын
Can you please change the background music in your videos, or better still, just have none. It’s pretty much the one and only thing that drives me demented with your videos. Other than that, keep them coming!
@tomkatgastraining2 жыл бұрын
Not had music in my videos now for over a year 👍🏻
@matttate91552 жыл бұрын
@@tomkatgastraining Yeh ok cool. The video I commented on was a year old now I look back though. The xylophone music was pretty awful though! Lol
@secondchance44983 жыл бұрын
chris Taylor
@gtroadster80354 жыл бұрын
Isn’t oxygen 20.9?
@tomkatgastraining4 жыл бұрын
In the atmosphere yes but on flue integrity we are looking for readings higher than 20.6 o2 and less than 0.2 co2 to prove the flue is ok
@gtroadster80354 жыл бұрын
Okay , I’m regards to the flueless fire. I came across a flueless fire with 2 catalytic converters. 1 on each side. How would I test when there is one on each side?
@andrewturpin19943 жыл бұрын
You mentioned caravans several times in the video which spiked my interest as this is my trade, would be very interested in seeing these tests done on an a modern oven in a touring caravan or motorhome 🚐
@mgbroadsterJ Жыл бұрын
death trap .
@Mrcatcherye2 жыл бұрын
no-one in their right mind would bother analyse a LFE fire. Pointless.