You received your new UPS unit, plugged it in and... nothing. In this video, Jon Sevel walks you through resolving this issue and getting your UPS up and running.
Still having issues? Give our tech support a call at 410-521-1000.

Пікірлер: 34
@KCotreau
@KCotreau 4 жыл бұрын
There is one basic thing that you left out. I have been an IT consultant for 25 years, and I recently took an old Smart UPS 1500 out of my closet. Frankly, I did not remember whether it worked, or not, when I stored it. It would not turn on at all, and I went through all your steps (most, of which I knew). Well, I took one last step: I had a second, working, Smart UPS 1500, and I swapped the battery, and sure enough, it worked. It was not dead, just the battery was totally done. A totally dead battery is also enough to cause this issue.
@GG-lw4fv
@GG-lw4fv 3 жыл бұрын
Anyway around this? I have 2 1500 RMs that I put in storage but want to use. Neither will power on. I dont want to buy new batteries just to find out theyre broken
@christophercondrat5371
@christophercondrat5371 3 жыл бұрын
Thank you for this! My DC disconnect popped out or was loose (it looked like it was still plugged in) and connecting it again fixed it!
@KarinaLoren
@KarinaLoren 10 ай бұрын
THANKS. This finally helped!
@Maisonier
@Maisonier Жыл бұрын
Great video! liked and subscribed.
@tonymontana897
@tonymontana897 Жыл бұрын
Hi Jon, My issue is a little different. I recently purchased a good used APC C 1500 UPS and it sat for maybe two months before I got to use it. It has the LCD display. After installing it, I connected power supply lead to main power then plugged one load cable to surveillance unit. I wanted UPS to my CCTV system in case of a black out. After pressing the power on button on UPS, the battery charge indicates very low battery due to it having sat around for a while, the batteries have discharged. What happens after a short time, after having line voltage, the UPS will drop the output voltage then switch off. Why would it turn off if it's connected to mains power. It should be charging the batteries AND be able to provide output to power external device right ? The Battery back up is only there in case of a power outage, but there is no outage as such as it's connected to mains power. Would a bad battery pack be messing with the electronics and is shutting the whole unit as a form of protection ? I hope you can share some knowledge here please. Thank you.
@majcrash
@majcrash 7 жыл бұрын
You didn't mention the fuse between the batteries. That could kill the DC side too. What is the amperage of the fuse on this model?
@CCAPACCO
@CCAPACCO 5 жыл бұрын
god speed captain hindsight!
@johnlin1650
@johnlin1650 3 жыл бұрын
Thanks
@sanjapkoki
@sanjapkoki 3 жыл бұрын
Is there a fuse inside the unit that could go out?
@anthonypeterson5618
@anthonypeterson5618 4 жыл бұрын
My 1000 unit doesn't have input pwr lights indicator on the bac of unit. I'm assuming the pwr transistor failure. Any schematics?
@anthonyalleyne8724
@anthonyalleyne8724 2 жыл бұрын
Hi i have the 2200xl 120 vdc, but the display face flat cable got damaged! and the power and test buttons r missing, is there a fix for it?
@Diyarlak
@Diyarlak 8 жыл бұрын
Hi I have APC Smart-UPS RT 5000 and it won't turn on>> please could you help me>>>> thanks for your kind help
@MrCazador123
@MrCazador123 10 жыл бұрын
mine still not working, tried all , its an forzaups at501
@khan-oq4qc
@khan-oq4qc 5 жыл бұрын
apc ups surt8000xli without battery how utility direct use
@manilkadesilva6884
@manilkadesilva6884 4 жыл бұрын
Hi my ups doesn't pass the POST. Where can i check first
@20EsOfficial
@20EsOfficial 6 жыл бұрын
The last time my ups was working, it was fully charged, and I've tried everything here and still nothing. I fully reconnected the battery. I was moving my ups, so I took out the battery disconnect and when I put it back in it seemed intermittent, so I pulled it out and put it back in got a big spark and it never came back on. What happened?
@martinkuliza
@martinkuliza 6 жыл бұрын
wMediaOnline hehe.. big spark huh Probably Blown a Capacitor or 2 Now. Unless you have electrical training, you SHOULD NOT attempt to replace them yourself but to answer your question it's Most likely Blown components if it did work, and now it's not working it means IN THE CIRCUIT BOARD there is a point at which the Electricity stops flowing because a part is damaged, this will usually occur because of an Over current situation in which case usually Fuses are what blow or Capacitors, beyond that you generally find Resistors and diodes are faulty and just because a Capacitor is not blown does not mean it is not faulty Most techs think that the way to check a capacitor is to get out a Multimeter and go to Capacitance setting. THIS IS NOT CORRECT (this is one small way, but not very reliable way to check) and ESR tester is required if one wants to check if a capacitor is good or bad. RELIABLY. I say get an electrician to look at it or ask the company how much they charge for a new unit or how much for a new Mainboard to be replaced You'll probably find that THE COMPANY that manufacturs it will make the cost of replacing the board more expensive than the Unit itself an electrician could (Depending on the issue) have a replacement cost of $1 - $50 (more realistically,.... approx $10) he would also want to charge for labour and time, so let's say $100 per hour for that, and you might be looking at $150 - $200 to get it fixed vs the cost of a new unit Unless you have a friend how is an electrician or Engineer in which case you'll fix it for under $50 hope that helps
@icns01
@icns01 6 жыл бұрын
Good real world advice...
@MrRaspopo
@MrRaspopo 9 жыл бұрын
hello please i do have smart UPS 1500. i have all 6 lights blinking anytime i blug in my ac power. but its runs okay on battery. kindly help me out
@CoasttecbyCBM
@CoasttecbyCBM 9 жыл бұрын
emmanuel alornyo Please fill out this help form and one of our technicians will help troubleshoot your issue: coasttec.com/support/contact-our-support/
@Max_Dutchman
@Max_Dutchman 3 жыл бұрын
Mine is charging well but not power on the outlet(s) when unplug the unit ( battery charged) when plugged in have power on the outlet(s)
@Spartankarthik4170
@Spartankarthik4170 2 жыл бұрын
Ants went inside my UPS LBPro 1000. It started fluctuating. Asked for technician.. Is there anything I can make the ants to stop going inside??.. please help
@asielrodriguezhernandez9695
@asielrodriguezhernandez9695 6 жыл бұрын
I have a Dell Tower UPS 1000W External Battery Module, but it does not turn on, if the batteries are dead, it does not turn on, or even if the battery is dead it turns on
@lordme88
@lordme88 8 жыл бұрын
If nothing of that sort works, can the circuits or something inside of the UPS be dead or just as simple as dead batteries? It is 12v batteries, right?
@bravebabar
@bravebabar 6 жыл бұрын
Will it turn on if batteries are completely dead?
@martinkuliza
@martinkuliza 6 жыл бұрын
Babar Khalid depends on the UPS, but it should turn on Fundamentally Uninterruptable Power Supplies work like this (Over simplified explanation)....... there are 2 sides to it the side that takes in Power from your wall the side that stores the power in case a black out happens so... While you have power coming in from the side that takes it from the wall point (simply stated) 2 things happen. 1. it supplies your devices / servers / computers /whatever with power 2. it fills up the batteries (Charges them, if you will) Point being (As you know) when a power outtage happens, there is a RELAY (Switch) inside that detects no current of Voltage coming in and it switches to BATTERY POWER When Voltage and Current is detected again.... IT SWITCHES BACK and refills the part that was used in the battery. so.... IF YOU DISCONNECT THE BATTERIES or IF THEY ARE DEAD all that SHOULD happen is this it should work as normal, EXCEPT if you have a power outtage it won't keep your devices on (Because the batteries are not charged) so your answer is... YES , it should still switch on but without the batteries working THE UPS IS JUST A GLORIFIED POWER POINT or POWER BOARD Hope that helps
@pontusakesson856
@pontusakesson856 6 жыл бұрын
"SC, SU, and SUA Smart-UPS require a functional battery be connected in order to turn on. If the battery is disconnected, or failed and completely drained, the UPS will not turn on. SMX and SMT series Smart-UPS do not have this limitation." from APC website
@khan-oq4qc
@khan-oq4qc 5 жыл бұрын
i need apc ups rt 8000 xli schematic diagram
@layton3503
@layton3503 3 жыл бұрын
I got all the way back to the power plant, I think I have as broken unit
@robotergaming_offl_2.0
@robotergaming_offl_2.0 2 жыл бұрын
APC UPS Apc the order number and they said they were working
@iforce2d
@iforce2d 4 жыл бұрын
What if the breaker reset button doesn't stay in when I press it?
@lilkngstr
@lilkngstr 2 жыл бұрын
did you figure out?
UPS BATTERY UPGRADE USING CAR BATTERIES
16:39
DIY-CIRCUIT
Рет қаралды 201 М.
Cute Barbie Gadget 🥰 #gadgets
01:00
FLIP FLOP Hacks
Рет қаралды 30 МЛН
Ну Лилит))) прода в онк: завидные котики
00:51
FOOTBALL WITH PLAY BUTTONS ▶️ #roadto100m
00:29
Celine Dept
Рет қаралды 75 МЛН
APC Smart UPS Rackmount Unit Won't Turn On
4:36
CoastTec
Рет қаралды 48 М.
APC UPS VA1500 Model BX1500M
8:32
Mike Faucher
Рет қаралды 34 М.
APC UPS BN1500M2 Fail
9:23
Just Silly Smart LLC
Рет қаралды 2,1 М.
Repair - APC Back-UPS M1000
15:30
z1power
Рет қаралды 48 М.
How to Quickly Test UPS Batteries Without the UPS Itself
18:27
Mark Furneaux
Рет қаралды 127 М.
how to rapair APC Back UPS 625 beeping problem
7:44
Athana's World
Рет қаралды 27 М.
How to Properly Choose & Use a UPS (Uninterrupted Power Supply)
11:34
Dan The Technology Man
Рет қаралды 808 М.
APC Back - UPS RS1500 - Battery Replacement
6:31
ReplaceUPSBattery.com
Рет қаралды 73 М.