Any that I have seen has a 90-degree elbow on the top. Keeps rain out of the pipe
@vintagetoast303811 ай бұрын
How is the electrical compartment setup? Do you wire your power in with wire nuts or is it connectors?
@aprilaireco11 ай бұрын
Thank you for contacting AprilAire! You would use wire nuts to connect power to the device. Outdoor installations require the use of a UL Listed watertight conduit. Ensure that all exterior electrical boxes are outdoor rated and properly sealed to prevent water penetration into the box. A means, such as a weep hole, is recommended to drain the box. The unit itself is UL listed, as such the wiring compartment itself is UL listed and meets the requirements for electrical equipment to be enclosed in a device. If you have any additional questions, please feel free to contact us at 800.334.6011.
@vintagetoast303811 ай бұрын
@@aprilaireco Thanks for the reply. I actually work for a radon installation company in Ohio. I was seeing about convincing the owner to try out AprilAire fans