HVAC Thermostatic expansion valve faulty how open how repair expansion valve Repair video Hindi me

  Рет қаралды 30,262

ASR Service center

ASR Service center

Күн бұрын

Пікірлер
@honestman276
@honestman276 Жыл бұрын
Thanks from Bangladesh.
@malikshahrukhmalikmuhammad2175
@malikshahrukhmalikmuhammad2175 2 жыл бұрын
Well done brother
@rinkubarman5482
@rinkubarman5482 Жыл бұрын
Sir me e tharmal power plan me p.a hu Kya eske sabhi part mil kasteh hai ,hardweyer ki dukaan me Kya xpe Sion valve Puri tarah se kharab ho jata hai ,feer se repering nahi ho sakta
@AmanKumar-px4qp
@AmanKumar-px4qp 3 ай бұрын
Thanks sir
@sahebalam7744
@sahebalam7744 Жыл бұрын
Kya equalizer close kar sakte hai bhai
@smkhalidjamal
@smkhalidjamal 8 ай бұрын
Sir ye kitne ton k compressor k liye use horaha hai or ye unit kitne ton ka hai
@CubanMofo
@CubanMofo Жыл бұрын
What happens if you don't screw on the sensing bulbon ?
@smkhalidjamal
@smkhalidjamal 8 ай бұрын
Is ecpanaion k pipe ka size kia hai
@wasimnasir7818
@wasimnasir7818 2 жыл бұрын
Agr expention valve na lagye or direct pipe join kardy koi problem ai gi compressor me
@CubanMofo
@CubanMofo Жыл бұрын
What happens if you permanently take off the sensoing bulb of the
@raheeztp3158
@raheeztp3158 2 жыл бұрын
👏👏👏👏👍👍👍
@amandeep3979
@amandeep3979 2 жыл бұрын
Drier chok hone k reason btaiye sir ye kyu chok ho jaate h
@malikshahrukhmalikmuhammad2175
@malikshahrukhmalikmuhammad2175 2 жыл бұрын
Super
@qasimsiddiqui2713
@qasimsiddiqui2713 2 жыл бұрын
Brother same Ac yehi model same system mein high pressure 280 per gaje ka sui vibrat krny lag jata hai even dryer filter bhi change Kiya ho to is expention valve ko kaisy adjust kren gey please bta den ya agr aap ne koi video pehly bnai hai to us ka link rply mein de dey
@asadmughal1426
@asadmughal1426 2 жыл бұрын
The TXV cannot be adjusted open or closed, it is a modulating valve. Turning the adjustment stem clockwise will only increase spring pressure causing a higher superheat.
@sajimahadevan4944
@sajimahadevan4944 7 ай бұрын
I have a question brother,if we have change TEV all internal parts and bellows then how can we pump down and store all gases in condenser coil if there is no shut off valve after TEV?.In such case we have to remove all gas or not?
@alphafurry658
@alphafurry658 2 жыл бұрын
Bro aluminum coil of ac me gas welding ho jata hai Kya
@faisalmahimi568
@faisalmahimi568 Жыл бұрын
Ha bilkul low flame rakho aour aluminium road ata hai ussi brizing karo
@kumardinesh1990
@kumardinesh1990 2 жыл бұрын
Pin market me milta h
@jollyscaria1922
@jollyscaria1922 2 жыл бұрын
Thankyou welcomedcap removing meackisom repasing new fixing
@waqasgafar3730
@waqasgafar3730 Жыл бұрын
Nac
99.9% IMPOSSIBLE
00:24
STORROR
Рет қаралды 31 МЛН
Сестра обхитрила!
00:17
Victoria Portfolio
Рет қаралды 958 М.
Quilt Challenge, No Skills, Just Luck#Funnyfamily #Partygames #Funny
00:32
Family Games Media
Рет қаралды 55 МЛН
Une nouvelle voiture pour Noël 🥹
00:28
Nicocapone
Рет қаралды 9 МЛН
Thermostatic Expansion Valve || TXV adjustment ||  TXV faults
11:48
FK mech official
Рет қаралды 24 М.
TXV, Thermostatic Expansion valve Full Details | Hindi #TXV #TEV#orifice
13:26
Unique Technical Service
Рет қаралды 41 М.
99.9% IMPOSSIBLE
00:24
STORROR
Рет қаралды 31 МЛН