Ok, I need to learn the ins and outs of building txv's. Thanks....
@TaddyDigest Жыл бұрын
Great Video
@Practicing_HVACR4 жыл бұрын
I didn’t make this up but it’s pretty useful when trying to remember if you should use the dew or bubble point. “Dewper heat & Bubble cooling”.
@abelurrutia11923 жыл бұрын
Sue, Dew is Genius.
@Nab-Asn28032 жыл бұрын
Thank you so much for this great vedio and a good demo 👍👍👍👍✅✅✅
@JohnDoesItAll7 ай бұрын
Great information
@amoryservicio264 Жыл бұрын
What happens if the small tube near the sensing bulb has a leakage but repaired as well? Can the txv still be functional?
@johnorr20554 жыл бұрын
It would be nice to have a head pressure control valve class
@muhammadrizwanjan19842 жыл бұрын
Want to know about temp of gas when passes through expansion valve?
@efrainpelaez12462 жыл бұрын
Awesome !!!
@kavishhassan60613 жыл бұрын
My expansion valve is sporlan HVE 5-1/2 not getting open properly our chiller is air cooled condensing type now we order as spare as per the tonnage of chiller which is 173 LRA now we ordered the spare and got the Sporlan HVE-16 expansion valve type with same inlet and out pipe as the existing one . Now we connect and started the unit flooding of refrigerant started. Can we adjust the HVE -16 expansion valve superheat to HVE 5-1/2 type. Pls suggest
@sporlanvideo3 жыл бұрын
Please contact our technical support team to assist you. 636-239-1111. Thanks
@JamesTalisim5 ай бұрын
I have AC UNIT using R22 refrigerant and has the txv in the system,my suction pressure is still low while putting in the refrigerant..I check for leak using soap bubbles no sign, I Also change the filter dryer I clean the Ac filters and lastly I clean the all evaporator coil but still giving low suction pressure. What the cause of this? Need help here
@sporlanvideo5 ай бұрын
You can contact technical support for help 1 (636) 239-1111. Thanks
@malkkingfifa4 жыл бұрын
What damage low air flow in the evaporator fan on the performance of the expansion valve (tev)
@sporlanvideo4 жыл бұрын
Low air flow across the evaporator coil will lead to low discharge pressure, low suction pressure, and low or hunting superheat.
@malkkingfifa4 жыл бұрын
@@sporlanvideo Thank you and is there an effect the superheat tex
@blockchainJP4 жыл бұрын
Nice video
@SuperRaisi3 жыл бұрын
From where can I know the standard superheat for my package unit?
@carrollprice12132 жыл бұрын
The adjusting screw needs to be accessible while the system is in operation.
@derickkenny31105 жыл бұрын
How do I get a sporlan hat?!?!
@SombraLocs4 жыл бұрын
Where do you get that Superheat stem tool?
@Synergy-95 Жыл бұрын
This txv I’m trying to adjust keeps going clockwise or counterclockwise forever pretty sure the dang stem is broke smh
@FIDAHUSSAIN-y7z Жыл бұрын
❤
@Keegeth3 жыл бұрын
TXV* lol
@wasimedoo79942 жыл бұрын
Small question sir how can I know the in and the out of the TXV thanks