I have now 3 dead solar controllers from Fangpusun, each has had upgraded firmware from Victron, they seem to work for awhile, I even put a temp controlled fan on the heatsink of one so it never has a chance of getting hot, lasted a few months then died, So I would keep a wide birth from these Chinses clones, save you money and buy Victron, best money ever spent was on Victron, I have not looked back
@leviahamefula39943 жыл бұрын
Read well, they warn not to upgrade with victron firmwares, as thise firmwares cone with a kill code for clones. 👀!
@clementlambert89132 жыл бұрын
Hi, 3 MPPT 30/100 from Fungpusun burnt in 2years in my sailing boat, while a 20/100 Victron is still alive for 2 years now.
@andrewwhittaker66222 жыл бұрын
Yes my 100/50 died shortly after a firmware victron upgrade also But the 100/30D's have been faultless for over 2 years now
@kevintewey11576 ай бұрын
If I remember these go-between 160 and 260 dollars U.S and they looked like they were built poorly
@jonaskubat60742 жыл бұрын
Hi Ross, good work. Can you share the part number of Mosfets originally used and your replacements? That will help me very much. Thanks.
@chrisszkwarek75948 ай бұрын
Hey did you end up repairing this I have one that I believe is software bricked due to victron forced updates
@sjdtmv8 ай бұрын
Welcome to the dead Fang club, yes I still have it on my shelf, It's only a dead weight now, yes firmware update will eventually kill it, if they don't by software updates die and have a short life compared to true Victron hardware, I have since gone Victron only and never been a problem since
@adamhenry27713 жыл бұрын
I have the Schematic of this Charger, any means to Extract the firmware from the S08 CPU ?
@sjdtmv3 жыл бұрын
I think the firmware is design for uploading only and not downloading or backup
@toglader3 жыл бұрын
could you send me schematics? I just bought a BDM interface to read firmware from this and schematics would help me in my work
@sjdtmv3 жыл бұрын
Ii have done no good, the mosfets are solid into the PCB, they could have been machine punched into the board before they are soldered
@vidyadharsharma64162 жыл бұрын
Ross can you help me in resetting error #40 on my victron mppt. I got the error when I connected my mppt with lithium phosphate battery 48v without precharging capacitor
@sjdtmv2 жыл бұрын
Err 40 - PV Input failed to shutdown If the charger is unable to turn off the PV input, it will go into a safe mode in order to protect the battery from over-charging or having a high voltage on the battery terminals. In order to do that, the charger will stop charging and disconnect its own output. The charger will become faulty. www.victronenergy.com/live/mppt-error-codes
@sharndordemonstalker2 жыл бұрын
How did you make the circular cuts?
@sjdtmv2 жыл бұрын
Used a large hole saw with the centre drill removed and clamped in my milling machine
@ghita04073 жыл бұрын
How did the repair go?
@sjdtmv3 жыл бұрын
They are unrepairable, the components are punched in before being soldered
@John-gm8ty3 жыл бұрын
@@sjdtmv could be using high temp solder too for better heat management wont' help though, as the victron firmware update has clone killer code in it. you HAVE to keep them stock.
@lexiecrewther70382 жыл бұрын
Capacitators? I think you mean capacitors
@sjdtmv2 жыл бұрын
Luckily there were no mention of Resisistors ... lol
@djnumberz18933 жыл бұрын
Please don’t buy this product again it die even if you don’t do any FW update on it. I have 3 that are dead now
@leviahamefula39943 жыл бұрын
I have mine running for about 2yrs.. no issues. The one that died on me, i disconnected battery while it was working nothing happened. I tried reconnecting, it sparked and died... I was able to convince them enough to get a warranty replacement although.
@djnumberz18933 жыл бұрын
@@leviahamefula3994 I have 3 all dead complain to them no reply from them