both ways gives the same result, you are right that u shouldn't change modifiers on both frame section and the column itself. but changing it on section property alone isn't wrong at all. personally i prefer doing it on frame section. much simpler
@arbaz284 жыл бұрын
Do we consider the cracked section for the econmical design?
@beenay183 жыл бұрын
I read somewhere that the property modifier of 0.7 for I22 and I33 in column should be used just to check deflection but not for determining reinforcement. For determining reinforcement. I22 and I33 should be 1. Is it true?
@srikanthvarma-qd4tj3 ай бұрын
Its very help full.I have one doubt. After applying modifiers in etabs model, if we export slabs to design slabs. Do we need to apply modifiers in safe model or no need to apply modifiers on safe model
@morshedali75234 жыл бұрын
جزاك الله خير
@Decodebd4 жыл бұрын
Barak Allah Fikum
@yasargnaniyar96923 жыл бұрын
Hi sir I loved your videos I have one doubt to ask you, If we change torsional modifier what will changes in reinforcement in site.
@nateshpradeep4 жыл бұрын
Bro do a video on stiffness modifier as per Codes with different member column beam etc and with different support condition
@roadtoconquer47974 жыл бұрын
from Nepal.
@Zorot99 Жыл бұрын
Should I apply the modifiers to choose steel reinforcement of the members? When do we apply these modifiers?
@mdsajibhossain8984 жыл бұрын
Its really Helpfull ..Thank you so much lovely DECODE BD
@Decodebd4 жыл бұрын
You are most welcome
@williamsentemtz96524 жыл бұрын
Thank you, sir. Please make tutorial on wind tunnel analysis, gust factor in details
@Decodebd4 жыл бұрын
In Etabs?
@anand42364 жыл бұрын
@@Decodebd ..yes in etabs only ... please do wind tunnel analysis in detailed
@satyambhosale7564 жыл бұрын
@@Decodebd yes in etabs please
@abhisheksen3253 жыл бұрын
please make videos on safe foundation thank you
@aashishp0074 жыл бұрын
U doing Good job!!!, Few queries as below 1. IS code doesn't specify weather we should use SM/PM with Service or Ultimate Load condition, whats's your take?? 2.Also further, should we use Property modifiers with P-Delta or without P-Delta?? 3. What should be SM/PM for slabs for IS code design??
@arbaz284 жыл бұрын
Refer IS 16700 Clause 7.2 for SM
@kavitakataria142 жыл бұрын
If I apply stiffness modifiers to beams and columns, KL/Depth ratio exceeds more than 12 and columns are designed as slender columns, show higher percentage of reinforcement and if I don't apply stiffness modifiers, Etabs designs those columns as short columns, pl. explain.
@samiulislamniloy67854 жыл бұрын
It's an amaizing video and suggession sir. thank you for your dedication. I would like to solve two confusions of mine. 1. In case of beam and column, should we change torsional constant also as well as Moment of Inertia? because in your previous video on this topic, you gave a chart of ACI-318 where torsional contant is also modified? 2. In your previous video on this topic, the ACI-318 suggested for flat plate and flat slab to change the modifiers for design to 0.25... My question is, should we also apply 0.25 for one way or two way slab design. If not, what will be the value? Kindly please reply sir. Thank you so much.
@maheshacharya72364 жыл бұрын
Thanks 👍
@Decodebd4 жыл бұрын
1. As per ACI Code we need to modify TC also. But IS code doesn't recommend it. 2. In this case Slab means slab whether it's supported on beam or not. Flat Slab indicates plate here, so to consider slabs as cracked section same value will be used for all slabs.
@samiulislamniloy67854 жыл бұрын
@@Decodebd Thank you sir. Take love.
@beenay183 жыл бұрын
For some reason my cantilever beams of balcony always fails in (torsion+shear) no matter how big section I assign. What might be the reason? I also asssign the torsion constant for beams to 0. Even then it did not work. Have any body come accross this problem? I would be so grateful if somebody could tell me whight might be the reason? My balcony is just 4 feet outwards. i assigned 9in x 14 inch beam but it fails. load is just 5 inch slab and 3KN live load and paraphet wall is made out of glass which might me considered as 0.5 KN/m. can any body tell me what size of beam would a 4ft balcony need.
@ChinTanLimbani4 жыл бұрын
@DECODE BD thanks for tutorial. For scale factor calculation which analysis shall be calculated? service un-craked model or cracked model for design? pl update
@maheshtelange51324 жыл бұрын
Very nice sir
@rahulsomde50944 жыл бұрын
How do i join two align beams in Etabs as a one member, if one beam is inclined from say plane A to plane B and other is in plane B?
@fahmiazwar33964 жыл бұрын
Thank you sir for sharing this. Sir, are you have a link to instal and download staad pro connect edition update 4 ?
@azmat_waseem4 жыл бұрын
Very Informative... Shukran...
@Decodebd4 жыл бұрын
Welcome
@dhvanitmehta70284 жыл бұрын
Serviceability criteria for the deflection, foundation not for design. So this modifiers should be used for design or deflection check?
@Decodebd4 жыл бұрын
Yes, serviceability check not for design, that's why after finishing design we need to change Stiffness Modifiers. I have just shown the result difference by design for SM- 0.7x0.9=0.63 & SM-1x0.9=0.9. It is obvious that if design result is different then deflection will also be different. Main focus is to discuss the mistake, not to check design or serviceability here.
@dhvanitmehta70284 жыл бұрын
@@Decodebd Gotcha. Thank you. 👍 And so basically we need to create two models one for serviceability and another for strength.
@artisahu45524 жыл бұрын
Sir can you pls make video on auto construction techniques option in etab used in construction .
@gaganpatidar99074 жыл бұрын
thx sir, plz make video on serviceability check and collapse check with modeifiers on a residential building. fianl reinforcement is decide on which check serviciability or collapse
@sourobhossain58924 жыл бұрын
Thank you very much ,Sir.
@Decodebd4 жыл бұрын
You are most welcome
@shahinurislam93734 жыл бұрын
thanks a lot, sir.
@shokryalqaisi59024 жыл бұрын
Great Eng.Mhd ,but i have a questions where is the pm for design in ACI Code ?
@abezerzerzeg4543 жыл бұрын
ACI 318-14 Building Code Requirements for Structural Concrete and Commentary .. page 72 check Table 6.63.1.1(a) Column 0.7 Beam 0.35 flat Slab 0.25 Wall (cracked 0.35 un cracked 0.7)
@civilpunchnama59124 жыл бұрын
Thank you....
@Decodebd4 жыл бұрын
Welcome
@rajeshkumarbharti33514 жыл бұрын
How to check the softstorey & torsion irregularity in Etab with excel sheet
@Decodebd4 жыл бұрын
Check previous tutorials I uploaded regarding these.
@bikeshshrestha94244 жыл бұрын
THANKS...
@Decodebd4 жыл бұрын
Welcome
@እንጅነርታላምኤሶ4 жыл бұрын
sir,i want etabs 2016 set up lattest version please help me
@manisingla38604 жыл бұрын
But now % r/f increase so it costly than provide in section property modify
@mdatifmaniyar66413 жыл бұрын
How did you become a structural engineer 😂😂
@engineermohammedsoyebbadgu37144 жыл бұрын
How Can you took 0.9 Values as per indian code... Please Give me Refrence Code... Thanks
@naveenkumarnkv41154 жыл бұрын
Check national building code.
@engineermohammedsoyebbadgu37144 жыл бұрын
Please Tell Me Page Number or other Things that make me Easy to find
@arbaz284 жыл бұрын
IS 16700 Clause N.o 7.2
@arunraj52804 жыл бұрын
Sir i need help in my project I’m working on static nonlinear analysis can u help me out??