Thank you sir , for teaching in such a nice and short way ......
@direct_civilsite2 жыл бұрын
Hiii
@kakidega66852 жыл бұрын
Yes 🥰
@direct_civilsite2 жыл бұрын
Are u snehal??
@abdulwahidturi4257 Жыл бұрын
All vedio u are presented is very fantastic vedio
@structuralanalysisanddesign Жыл бұрын
Thank you so much 😀
@anirudhparvatikar7990 Жыл бұрын
Explanations are clear and to the point. Thank u very much sir.
@neethuraj55014 жыл бұрын
Thank you sir... The concepts are cleared
@structuralanalysisanddesign4 жыл бұрын
Welcome, all the best
@amalasaseendran61133 жыл бұрын
Thank you sir.This is very helpful to me
@structuralanalysisanddesign3 жыл бұрын
Most welcome, happy to help, keep supporting
@jigar_00724 жыл бұрын
Very nice sir. Easily clear all concept and make more video... 👍👍👍
@structuralanalysisanddesign4 жыл бұрын
Thank you so much Mehul, yes we are coming up with more videos
@allanjonathan13492 жыл бұрын
Wonderful video!
@structuralanalysisanddesign2 жыл бұрын
Thank you very much! Keep watching and sharing
@sudarshannikam52434 жыл бұрын
Thanks sir , Your diagram is so proper that first time i could understand properly that how moves xu lim axis up and down in under and over reinforced section with proper reason.Thanks by heart..
@structuralanalysisanddesign4 жыл бұрын
I am very happy that I made you understand the concept, support me by sharing with your friends, keep watching and keep learning, all the best
@rajmanoj83454 жыл бұрын
thank you sir this content is really helpful in this lockdown
@structuralanalysisanddesign4 жыл бұрын
Glad to hear that, thank you so much, will be coming up with more videos, keep watching
@soranroshn76452 жыл бұрын
الله یهدیك الی اصح الطریق
@toshagrawal46293 жыл бұрын
Hii when lets assume in T section which is under reinforced depth of N.A. from extreme compression fiber is 50 mm (maximum compresive strain is 0.0035) and depth of centre of tension reinforcement from NA is 500 mm(thus by compatibility of strain tensile strain will be 10 times maximum compresive strain) is that much strain allowed?
@mohammedmohammedsuliman96143 ай бұрын
Short but deep meaning ❤
@ravishanker26633 жыл бұрын
Thank you very much Sir 🙏
@structuralanalysisanddesign3 жыл бұрын
Most welcome, all the best
@jitendrashah2054 жыл бұрын
What type of beam provide that may not failure and remain safe.
@structuralanalysisanddesign4 жыл бұрын
According to IS Code it is stipulated to provide under reinforced beam
@ShivanshRana25 күн бұрын
5 marks secured in exam with this video❤😂
@Vishalkoshta30004 жыл бұрын
nise point to point explanation.
@structuralanalysisanddesign4 жыл бұрын
Thank you
@wadani49244 жыл бұрын
What is critcal depth and actual depth
@prakulchauhan2924 Жыл бұрын
Which type of section give sign before fail
@tulasiratna44053 жыл бұрын
𝐓𝐡𝐚𝐧𝐤𝐬 𝐟𝐨𝐫 𝐲𝐨𝐮𝐫 𝐯𝐢𝐝𝐞𝐨 𝐬𝐢𝐫.
@SteelRCC5 жыл бұрын
Well done..keep posting on other topics
@structuralanalysisanddesign5 жыл бұрын
Yes sir, coming up with analysis and design of all RCC structural elements
@Manas_Gupta Жыл бұрын
Thank you Sir 🙏
@structuralanalysisanddesign Жыл бұрын
Most welcome, all the best, keep sharing
@yimmytjahjono62622 жыл бұрын
Please explain, in the case of under-reinforced beam vs the rest, how is it that the ability to visualize excessive stress in concrete beams is better that the ability to support such stress? Let's say an under reinforced concrete beam will start to bend to support 10 tonnes of stress, while the over reinforced beam will be able to support 12 Tons of stress comfortably, if the load is 12 Tons, how is the under-reinforced beam better performed when it clearly failed?
@meleyotanoyeleke4800 Жыл бұрын
While engineers design against failure, I have learnt they design things to "safely" fail too. An under-reinforced beam failing on applied 10 tonnes load fails by yielding gradually, using up all the ductile properties of the steel in tensile region, this makes it easier to detect it's failing and allows engineers to act on correcting the structure before it completely fails. But a 12 tonnes capacity over-reinforced beam will fail suddenly if it exceeds capacity making it very dangerous to use.
@leeladhargadgil60294 жыл бұрын
What will happen if I also provide steel in top side of beam in Over reinforced beam ?
@structuralanalysisanddesign4 жыл бұрын
Dear first of all u should not provide over reinforced beam, and if its over reinforced section why you want to provide extra steel on top?
@leeladhargadgil60294 жыл бұрын
In this case, I'm still not able to get difference between all three sections. I meant to say is if I provide 3 bar in bottom and 2 or 3 bar in top also, will be that be an over reinforced section ? Does Ast play any role in deciding the type of section ? And in your balanced section, what if I provide 2/3 bars in top also ?
@naveenreddy85013 жыл бұрын
@@leeladhargadgil6029 then it becomes doubly reinforced beam, u should also satisfy the max percentage of steel reinforcement in beam I,e 4% of bd
@shivatyagi41754 жыл бұрын
Is under reinforced beam deeper when compared to a balanced beam section????
@440xavier2 жыл бұрын
Sir hindi me accha se samajh aata hai
@shrawanshah82915 жыл бұрын
Sir didn't get what is critical neutral axis
@structuralanalysisanddesign5 жыл бұрын
its maximum
@VirendraKumar-pr4oj4 жыл бұрын
Nice sir ji
@structuralanalysisanddesign4 жыл бұрын
Thank you so much
@chandudileep8402 жыл бұрын
Could you please explain prestressed concrete sir
@structuralanalysisanddesign2 жыл бұрын
Your request noted, will try to come up with some videos on this topic
@bhagyeshwadhale81013 жыл бұрын
Sir, I want to do design structure so which software is good to design
@chandudileep8402 жыл бұрын
Thank you sir
@structuralanalysisanddesign2 жыл бұрын
Welcome, all the best, keep watching and sharing
@gamirambhul18473 жыл бұрын
super sr
@structuralanalysisanddesign3 жыл бұрын
Thank you so much, keep watching
@ethandkharofficial28044 жыл бұрын
Sir what is meant by yielding of steel
@fayazkhan5186 Жыл бұрын
Thanks sir
@structuralanalysisanddesign Жыл бұрын
All the best
@devendrabagul84 Жыл бұрын
Thanx sir
@structuralanalysisanddesign Жыл бұрын
Most welcome, all the best
@wasiullah56232 жыл бұрын
I think that over reinforce strain diagram suffle with under reinforce strain diagram.
@ramkumarv28744 жыл бұрын
Thank you
@structuralanalysisanddesign4 жыл бұрын
You're welcome
@rajanalalalit16915 жыл бұрын
thank you, sir...
@structuralanalysisanddesign5 жыл бұрын
We are happy this video helped you, stay tuned for more videos
@ahtishamkakar66524 жыл бұрын
Kindly clear that Area of steel is greater than Area of steel in critical section
@JawadAhmad-4 жыл бұрын
Dear Sir, I want to talk to u
@handsam5 Жыл бұрын
I would rather believe in real life demonstration (tested or proven) and what grade of steel they are using. rather than only on "THEORY".
@AnandKumar-pu6bp4 жыл бұрын
thanku sir
@aneetareddy9889 Жыл бұрын
🙂🙂
@sathish28683 жыл бұрын
Stress diagram
@rohitrajak4120 Жыл бұрын
sir agr engilsh me samjna hota toh ham book hi padh lete 😅
@440xavier2 жыл бұрын
Sir English me samajh nahi aaya🤐
@kasanadevesh3 жыл бұрын
not good
@structuralanalysisanddesign3 жыл бұрын
Kindly you can make video and explain it in a better way
@badAssfighter0076 ай бұрын
in most cases when fe 250 is provided as compression reinforcement then it will attain its design yield point but in case of fe415 and fe500 steel,it is not possible WHY ???????????