basement bathroom roughin drain and venting2

  Рет қаралды 383,804

Plumbing Helper

Plumbing Helper

Күн бұрын

Пікірлер: 90
@Pipeleier
@Pipeleier 6 жыл бұрын
Sanitary tees are not to be used on their back and the vent connection for the shower is installed backwards. Also some of the vent fittings are installed backwards
@plumbinghelper7993
@plumbinghelper7993 6 жыл бұрын
I'm glad someone is paying attention. Glad you picked up on the vent T orientations. Would you mind stating the correct usage when a DWV (Drain Waste Vent) T is used as a venting T, particularly in the horizontal drain line? In my state, the configurations shown for the venting Ts in the drain lines would normally be allowed, though, agreed with you, sloppy. The DWV vent T is used to pass air and allow in line condensate to drain. In my state, a vent T (looks like a squared T, vs one with a lead-in), on its back, is not allowed in the drain line. Must use a DWV fitting., as shown in the clip.
@raymondrouthier3920
@raymondrouthier3920 6 жыл бұрын
Marcus Stolley yep
@michaelolson
@michaelolson 5 жыл бұрын
Journeyman plumber here and I saw all those backward Ts right away also, my master would flip his lid if I did this!! Huge mistake. Always keep in mind the direction of flow as to the direction of your fitting. I’ve made this mistake more than once, especially when you are working upside down and figured it standing up.
@danieldawson222
@danieldawson222 4 жыл бұрын
You noticed that to? Saw the vent tee the first thing, some one needs To inspect these "C A D" drawings!
@Pipeleier
@Pipeleier 4 жыл бұрын
@@plumbinghelper7993 When venting fixtures below the flood rim drainage fittings must be used. In this example the sanitary tees must be replaced with combination wye/45 fittings for the shower and the toilet.
@jwblount7802
@jwblount7802 4 жыл бұрын
So the only T you people noticed that was backwards was on the drain system at the shower and not notice that all of the T's in the vent system is facing the wrong way of air flow!
@tylerwhitfield419
@tylerwhitfield419 6 жыл бұрын
I wouldn’t use standard 90’s for the toilet flange, just Wye + 45 to the flange. I would typically set up a wet vent to avoid having to vent three separate fixtures.
@tylerwhitfield419
@tylerwhitfield419 6 жыл бұрын
Horizontal to horizontal joints should always use some sort of long sweep.
@joshuamoore24_7
@joshuamoore24_7 3 жыл бұрын
The santees are not are supposed to be there, you need combos with a long turn and the flow pointing to the direction of the grade downward flow of the main. Plus the toilets supposed to have a three inch vent stack and a clean out, then if the dfu's(drainage fixture units) allow reduce it to two inch above the clean out. The Santee's in the on the vent piping are pointing the wrong direction also. The flow of the sewer gas is supposed to point to the vent pipe end above the roof. This must be a point out what's wrong with this plumbing diagram video.
@danlovins3155
@danlovins3155 4 жыл бұрын
Please don’t use this drawing!!!There are some major mistakes on it. Sanitary tees backwards, wet venting, sizing of pipe.
@azycray4801
@azycray4801 4 жыл бұрын
Agreed, this looks like a homeowner did it. Also the short turn elbows on the w/c horizontal.
@alang8243
@alang8243 3 жыл бұрын
@@azycray4801 Would the toilet horizontal drain layout be OK if the short turn 90's were long sweep 90's?
@azycray4801
@azycray4801 3 жыл бұрын
@@alang8243 Yes, however I would always try and minimize changes in direction. So those 2 elbows equal 180 degrees of turn before joining the shower drain. Depending on where the walls were gong to go this may have been the best they could do but normally a little thought can limit the change in direction to less than 180. If a main sewer snake ever has to be run from this W/C location, it will make the job much easier, especially if it has to be run a long distance or cutting roots out front. Of course a clean out installation is always preferable but not always available.
@alang8243
@alang8243 3 жыл бұрын
@@azycray4801 Hey thanks for the info. I'm laying my drain lines out right now for a basement bathroom, and I have a similar pattern in order to get the vent under the wall. It flows to a BWV that connects to my main 4". That 4" line has a cleanout in a good location for "roto-rooting" in the future.
@8thyearApprentice
@8thyearApprentice 3 жыл бұрын
I was looking at the directions of those vent tee's.....and the laundry line needs to be below the utility sink drain on top of the shitz you said .. nice catch plummma
@sulmyguzman3280
@sulmyguzman3280 Жыл бұрын
what program's is this?
@karlhalvorson
@karlhalvorson 2 жыл бұрын
If that's a SketchUp model, I'd love a copy of it. How can i get one?
@IdahoSnake-A-Drain
@IdahoSnake-A-Drain Жыл бұрын
Trap Arm on Laundry trap to short, its an "S" trap basically.
@hyster2568
@hyster2568 4 жыл бұрын
Wet venting, tees are backwards. Another thing, you can’t use a santee on its back. You’re suppose to use a combo
@LubaLuba1
@LubaLuba1 4 жыл бұрын
But how can add a new shower drain to existing toilet drain on concrete slab ?? The cast iron pipe for the toilet come up from below so I need to cut before toilet flange but do I need to make a large hole / diameter??Thank you!
@Pipeleier
@Pipeleier 4 жыл бұрын
You need a jackhammer and a plumbing contractor
@eng-vf2gh
@eng-vf2gh Жыл бұрын
name of this animation program can you give us the name sir
@TheSpatulaCity
@TheSpatulaCity 3 жыл бұрын
1:29 Not enough horizontal pipe after P trap? I'm not a plumber but I've learned that there needs to be at least a length of pipe equivalent to double the pipe diameter after a P trap. Otherwise it can act like an S trap and siphon the water out of the trap and leave sewer gases inside.
@Macksbet
@Macksbet Жыл бұрын
this whole diagram violates several plumbing codes from both books. it should be deleted from youtube so noone gets taught the wrong way to do plumbing
@marka.2715
@marka.2715 2 жыл бұрын
I though the toilet couldn't flush past other fixtures?
@MrDarren5012
@MrDarren5012 4 жыл бұрын
Why would you run the toilet with two 90s? Why not just a 45 strait to main drain? Same with shower
@LHAGYALO258
@LHAGYALO258 4 жыл бұрын
You nailed it
@borispeck6879
@borispeck6879 2 жыл бұрын
Sorry check your horizontal venting fittings ????
@brucedeleskey8540
@brucedeleskey8540 3 жыл бұрын
This is the way it should be shown 1 2 3. If you don't understand this. Don't try this because you're a dangerous
@brandonisrael5935
@brandonisrael5935 3 жыл бұрын
The sanitary tee coming off the shower, for the vent, should be flipped around. You should always flow down hill.
@kona6451
@kona6451 2 жыл бұрын
yep and a few of the upper ones were backwards as well.
@rocketrider1405
@rocketrider1405 5 жыл бұрын
Does the laundry sink need a p-trap? I didn't see one. Thanks for the video .... this info never gets old !!!
@brandonmurphy2009
@brandonmurphy2009 5 жыл бұрын
Laundry sink will have a P-trap once you install the actual sink!
@troylitle3116
@troylitle3116 4 жыл бұрын
It has a bag trap like a kitchen sink or a lavatory sink
@fredpastuh7518
@fredpastuh7518 4 жыл бұрын
Mistake in shower vent T?Or no?
@skycladraven1248
@skycladraven1248 4 жыл бұрын
What software did you use to create this video?
@jinliangchen2757
@jinliangchen2757 Жыл бұрын
It might be a sketchup built in feature
@kylepace4302
@kylepace4302 4 жыл бұрын
Why is the vent tee backwards?
@omegaplumbing
@omegaplumbing Жыл бұрын
The mistakes are numerous. 1) toilet should wet vent shower and lavatory. (this would correct the other mistakes) 2) shower t-wye incorrect direction and a t-wye or santee is not a drainage fitting should be a wye. 3) toilet incorrect it 180 back on itself. 4) 1/4 bends on turns incorrect 5) 3x2 tee wye on its back incorrect for toilet 6) no cleanouts on 2 inch coming out ground 7) bushings should not be used but coupling reducers for servicing. 8) vent tees wrong direction 9) Washer box p trap too high off ground should be bewteen 6-12" inches 10) P trap too close to santee creates s trap. Should be twice the distance of the pipe being used 2" would be at least 4" pipe not hub to hub. 11) Washer box drain dumping on top of laundry tube drain not good practice for suds relief. 12) You cant wet vent these fixtures unless the drain pipe is 2 pipe sizes larger. The drain should be 3 inch then a 3x2 wye for the washer box, then a 2 inch santee on top of that serving laundry sink. 13) backwater valve should be on the main preferably outside and the access brought to grade.
@jesusortiz6842
@jesusortiz6842 4 жыл бұрын
Thanks for sharing with us. Could I install 2vent lines o 1 is enough. O is not allowed to add 1 extra in 1 circuit?
@Pipeleier
@Pipeleier 4 жыл бұрын
With a little thought I'm sure there is a way to horizontally wet vent this bathroom using the toilet vent for the shower vent and the lavatory drain
@Kenisproactivehere
@Kenisproactivehere 3 жыл бұрын
Almost a great video BUT...it moves too fast to read clearly. Thanx
@roohdeepsidhu1073
@roohdeepsidhu1073 5 ай бұрын
The T which used for shower drain’s vent is not correct
@djfremen
@djfremen 5 жыл бұрын
What software did you use to mock up?
@joe5938
@joe5938 5 жыл бұрын
Sketchup
@russron1
@russron1 4 жыл бұрын
The san tee for vent needs to slope towards the waste line not the p trap
@realmadrid091884
@realmadrid091884 2 жыл бұрын
Thank you
@evaldopires3630
@evaldopires3630 3 жыл бұрын
This video is more like find the mistakes. Do we get some gift for it? I've found 8 mistakes
@jadenandraos-fazari3930
@jadenandraos-fazari3930 6 ай бұрын
Vent tees backwards, and the shower back vent tee is backward, also the vent leaving the roof has to be 3" not 2. Don't rough in like this plz 🙏
@Magnum-vr5yl
@Magnum-vr5yl 3 жыл бұрын
Vent tee’s are backwards
@turtleturtle4909
@turtleturtle4909 3 жыл бұрын
Can you share this file? This is sketch Up, yes?
@jaredfink725
@jaredfink725 4 жыл бұрын
what is the music? so dope
@mublikbublik7911
@mublikbublik7911 4 жыл бұрын
So dope, it's retarded.
@barbudabob1
@barbudabob1 5 жыл бұрын
This is super excellent....can you do an electrical like this?
@Macksbet
@Macksbet Жыл бұрын
i see two missing cleanouts and a very important missing vent, props to anyone who knows what im talking about. oh yeah and all those illegal fittings. edit: and on my way out i wondered if this room requires a floor drain, lolllllllllllll
@darrionkemp1948
@darrionkemp1948 5 жыл бұрын
plumber spfld il, well done video
@VamooseRooter
@VamooseRooter Жыл бұрын
This plumber needs help. Not me, the guy who drew this. Read the codebook
@alanm2842
@alanm2842 4 жыл бұрын
the laundry sink and washing machine need to go through the back water valve
@jutka19550603
@jutka19550603 5 жыл бұрын
Toalet, vagyis WC 110 mm tehát 4 inch !
@joshuanorris9785
@joshuanorris9785 5 жыл бұрын
cool diagram thank you!
@Phamduytan90
@Phamduytan90 Жыл бұрын
@DailyMotivationUniversity
@DailyMotivationUniversity 2 жыл бұрын
Also short turn 90s on side is a no no ... who taught you should be slapped
@WildWorldMedia1
@WildWorldMedia1 4 жыл бұрын
45° bro
@josephshuler1874
@josephshuler1874 3 жыл бұрын
San tee is backwards
@dannybaldivia2731
@dannybaldivia2731 Жыл бұрын
Lol wow I guess 🤦🏼😂🤣
@SuperStevo17
@SuperStevo17 5 жыл бұрын
the vent t's are going the wrong way. look when he shows the top of the vent that is supposed to go out the roof.
@keithmann7857
@keithmann7857 5 жыл бұрын
The 2 inch vent for the shower is backwards as well.this is a bull shit video
@onlymecz
@onlymecz 6 жыл бұрын
Great! Thank you
@jasveerbrarganga914
@jasveerbrarganga914 3 жыл бұрын
All vent are wrong
@vincentchato519
@vincentchato519 4 жыл бұрын
All the venting is wrong just saying
@Pipeleier
@Pipeleier 4 жыл бұрын
yep
@jwil4905
@jwil4905 3 жыл бұрын
The venting is fine. Some of the fittings are wrong.
@vincentchato519
@vincentchato519 3 жыл бұрын
Yes all San tee's are in backwards in the venting.
@thomasclint007
@thomasclint007 3 жыл бұрын
Lots of mistakes Don't learn from this design.
@upstateplumbing9995
@upstateplumbing9995 2 жыл бұрын
What a stupid way to run a toilet line
@DavidThomasNJ
@DavidThomasNJ 5 ай бұрын
Way wrong on many levels
@besearchingforwisdom6267
@besearchingforwisdom6267 4 жыл бұрын
Really? Why the stupid music?
@ombatibenjamin685
@ombatibenjamin685 2 жыл бұрын
Am new I would I know to fix them
@charlesmaou6375
@charlesmaou6375 5 ай бұрын
THis video tells me nothing at all.
@ArchinatorWC88
@ArchinatorWC88 2 ай бұрын
What software do you use to design?
Plumbing a bathroom explained in 4 minutes. [You CAN do it!] #diy #plumbing
4:20
Rising Tide Plumbing
Рет қаралды 679 М.
How To Vent & Plumb a Toilet (in 2024)
6:59
Hammerpedia
Рет қаралды 2,6 МЛН
She made herself an ear of corn from his marmalade candies🌽🌽🌽
00:38
Valja & Maxim Family
Рет қаралды 18 МЛН
The evil clown plays a prank on the angel
00:39
超人夫妇
Рет қаралды 53 МЛН
Quando A Diferença De Altura É Muito Grande 😲😂
00:12
Mari Maria
Рет қаралды 45 МЛН
Building a House - #09 Underground Plumbing
5:54
Daniel Heap
Рет қаралды 812 М.
The #1 DWV Plumbing Mistake (and how to prevent it).
3:07
Hammerpedia
Рет қаралды 5 МЛН
Como hacer el drenaje de un baño completo.,Curso de plomeria capitulo  15
7:39
Shower Drain Plumbing Mistakes and How You Can AVOID Them
5:42
Home Repair Tutor
Рет қаралды 117 М.
Basement Bathroom Construction Ideas
5:55
Bathroom Remodel Videos
Рет қаралды 572 М.
10 Reasons Why You'd FAIL a Plumbing Inspection! | GOT2LEARN
7:36
Concrete Removal for a Basement Bathroom
14:54
Bathroom Remodeling Teacher
Рет қаралды 38 М.
How To Plumb a Bathroom (with free plumbing diagrams)
6:18
Hammerpedia
Рет қаралды 6 МЛН
how to do rough in plumbing for a bathroom & kitchen in a basement?
36:39
Renovation school
Рет қаралды 183 М.
GROUNDWORK - PLOMERIA COMPLETA |  ROUGH-IN  | MIRA ESTE VIDEO!!🚿
14:21
D PLOMERIA Y MAS
Рет қаралды 18 М.