RF Design-14: Load Pull - Advanced Techniques

  Рет қаралды 11,450

Anurag Bhargava

Anurag Bhargava

Күн бұрын

Пікірлер: 35
@NagabhushanD-lz8od
@NagabhushanD-lz8od 4 ай бұрын
hello sir , thank you for these videos. I am interested in finding harmonic impedances. Can you help me find 2nd and 3rd harmonic impedances.
@BhargavaAnurag
@BhargavaAnurag 2 ай бұрын
You can set up Load Pull for harmonic frequencies. Contact Keysight tech support team if you are not able to set it up but it should be pretty easy
@hamidk4772
@hamidk4772 3 жыл бұрын
Outstanding job.
@BhargavaAnurag
@BhargavaAnurag 3 жыл бұрын
Thank you! Cheers!
@HamzaKiani3
@HamzaKiani3 3 жыл бұрын
Unable to follow these days but will bother you when I'll watch them again 😜 . I hope I could get a similar channel for HFSS and CST 😢
@BhargavaAnurag
@BhargavaAnurag 3 жыл бұрын
Hi Hamza, Look forward to your queries whenever you get back on ADS....👍
@Scuba_Bro
@Scuba_Bro 3 жыл бұрын
Hello Anurag, I am using ADS2020 (Update 1) and went into the design guide under the amplifier section and selected the "HarmonicZopt" workspace under DesignGuide==>1-Tone non-linear simulations==>'Harmonic Impedance Opt.' However, after I run it with the device provided, the simulation runs with no problem but when I go into the data display the only tab that seems to mostly display any data is on the first tab. When I go to 'Equations' tab in the data display all the equations are red though their syntax is correct and they are indeed choosing the right variable equations from the schematic. Now I know that I typically can't plot a variable in data display unless it's for a measured equation or used in a simulation controller typically but I wasn't sure if I was doing something wrong or if there may be a slight error in the design guide for this as I know it's likely over 10 years old now from the 'Read Me' schematic in the design guide work space. Please help if you can! and as always thanks for your help and these videos.
@BhargavaAnurag
@BhargavaAnurag 3 жыл бұрын
Hi, Here are my comments: 1. The template you referred is created for Optimization. Instead of running Simulation you need to run Optimization once it finishes close Opt cockpit & update the variables and look at the data display and you would see all equations being calculated properly and you can see load and source impedances as you expect. 2. If you want to see the data after simulation then double click on HB controller, go to Output Tab and select Add/Remove and then select all Rsrc, Rload, Imsrc, lmload etc and click on Add button so that these variables are sent to dataset after simulation. 3. Run simulation and everything should be as expected 4. Reason it is done this way is to prevent users to run normal simulation, see the impedance data and assume that these are optimum values for impedance matching which they will be not unless you run Optimization to obtain desired value, ideally with FinalEF=0 or very close to 0. Hope this helps....👍
@Scuba_Bro
@Scuba_Bro 3 жыл бұрын
@@BhargavaAnurag , that worked! I did the optimization but was still getting red equations in display after I updated schematic however once I put the variables in the equation onto the harmonic balance output that fixed it all! this was such a huge help! I can’t even put into words how grateful I am that you responded to me and gave me such detail on here! Infinitely many thanks and gestures of appreciation to you 👍🙏🏻
@BhargavaAnurag
@BhargavaAnurag 3 жыл бұрын
@@Scuba_Bro just spread happiness, share knowledge and help anyone you can and we all will be happy. All the best...👍
@Alper_SEV
@Alper_SEV Жыл бұрын
Thanks a lot sir.
@BhargavaAnurag
@BhargavaAnurag Жыл бұрын
All the best
@fourierv2
@fourierv2 3 жыл бұрын
Thank you for the insightful video, Anurag. Could you provide any insights as to when the next installment may be released?
@BhargavaAnurag
@BhargavaAnurag 3 жыл бұрын
Hi, I plan to post it on Wednesday or Thursday this week.
@fourierv2
@fourierv2 3 жыл бұрын
Thank you. The convergence tricks you mentioned are of interest to me is all. Keep up the great work!
@zaherkakehbra7282
@zaherkakehbra7282 Жыл бұрын
Hi @BhargavaAnurag Thank you for your excellent explanation. I have a question. I am,m using TSMC 0.18um rf technology to design a power amplifier. But I haven't a data sheet to determine "Z_Source_Fund" to run the Load Pull simulation. How much of it should I put into the simulation? Please guide me. Best regards.
@BhargavaAnurag
@BhargavaAnurag Жыл бұрын
You shouldn't get hung up on Z source, you can always start using 1-5 Ohms as a starting point and then you can arrive at the proper impedance when you start to use Load Pull or Source Pull.
@michaelyin269
@michaelyin269 Жыл бұрын
Thank you sir for your sharing. Btw, how do I get DCIV simulation result in the video? It doesn't work if I using the same eqn. expression.
@BhargavaAnurag
@BhargavaAnurag Жыл бұрын
Kindly contact Keysight tech support team for help
@saifulsyazwanyusoff9075
@saifulsyazwanyusoff9075 3 жыл бұрын
Hello Sir, Can tell me step by step how to change the ideal circuit to a microstrip line using MLIN, MTEE components. I have designed the basic rectifier and didn't know how to change it into stripline form.
@BhargavaAnurag
@BhargavaAnurag 3 жыл бұрын
I am not sure what you want to convert...usually in circuit sim you can connect component using wire and later want to connect them using microstrip lines etc...if that is what you want then simply define the substrate using MSUB on schematic and use transmission lines from library and use them on your circuit design. If it is rectifier then it will be quite low frequency so microstrip lines may not affect circuit performance too much.
@biplabmondal9420
@biplabmondal9420 5 ай бұрын
please upload the final load pull video
@BhargavaAnurag
@BhargavaAnurag 5 ай бұрын
All videos are uploaded. Kindly check the playlist to see all videos
@stevexinjin4392
@stevexinjin4392 3 жыл бұрын
Hi Anurag, I couldn't find expression manager in View or Tools. Maybe I missed some part in your earlier video. Would you mind point me what's the problem?
@BhargavaAnurag
@BhargavaAnurag 3 жыл бұрын
Hi Steve, It should be there in the View menu and pressing "E" should make it on or off. Which ADS version are you using?
@stevexinjin4392
@stevexinjin4392 3 жыл бұрын
@@BhargavaAnurag Thank you for replying so quick! I'm using ADS 2020.. It not inside View - it's in my Edit tab. However, I click it and it pops up a dialogue and seems the "database" type variable is not included, which means I cannot look up the values or data structures.
@BhargavaAnurag
@BhargavaAnurag 3 жыл бұрын
@@stevexinjin4392 You need to be on ADS2020Update2 or higher to utilize the capability. Best is to use 2021Update1 and it also allows you to use drag & drop plot as shown in the video: kzbin.info/www/bejne/bYnMeolsmMd9gs0
@stevexinjin4392
@stevexinjin4392 3 жыл бұрын
@@BhargavaAnurag That's really cool. Will try. Thanks!
@alexranjan9429
@alexranjan9429 Жыл бұрын
Hello sir, Can you told me about the Z_In and Z_load value for device CGHV40320D because I did not find in the data sheet .
@BhargavaAnurag
@BhargavaAnurag Жыл бұрын
You don't need that as you can find it out from the Load Pull and Source Pull simulations. You can start with your best guess and then narrow it down based on the simulation results.
@alexranjan9429
@alexranjan9429 Жыл бұрын
@@BhargavaAnurag thank you so much for your guidance sir.
@djganiboy7643
@djganiboy7643 3 жыл бұрын
Hello sir, your videos are very helpful. I have a project about ads for RF energy harvesting system. Can I ask you some questions via e-mail when you are free?
@BhargavaAnurag
@BhargavaAnurag 3 жыл бұрын
You can post your queries here and I can try to answer those
@errikosgk7004
@errikosgk7004 7 ай бұрын
I cannot add GL on data display. How can I solve this issue?
@BhargavaAnurag
@BhargavaAnurag 6 ай бұрын
Kindly contact local Keysight tech support team for help
RF Design-15: Graphical LoadPull and XdB Compression LoadPull
28:48
Anurag Bhargava
Рет қаралды 8 М.
Understanding Load Pull
19:23
Rohde Schwarz
Рет қаралды 21 М.
Seja Gentil com os Pequenos Animais 😿
00:20
Los Wagners
Рет қаралды 88 МЛН
HELP!!!
00:46
Natan por Aí
Рет қаралды 37 МЛН
MAGIC TIME ​⁠@Whoispelagheya
00:28
MasomkaMagic
Рет қаралды 37 МЛН
RF Design-13: Getting Started with Load Pull Simulations
30:13
Anurag Bhargava
Рет қаралды 28 М.
How to Setup and Run Load Pull Simulations: The Basics
8:37
Keysight Design Software
Рет қаралды 38 М.
Design Example:  Class F Power Amplifier (PA)
16:23
AWR Design Environment
Рет қаралды 12 М.
Flawless PCB design: RF rules of thumb - Part 1
15:45
Hans Rosenberg
Рет қаралды 84 М.
RF Design-25: CPWG Based Designs in ADS
38:22
Anurag Bhargava
Рет қаралды 17 М.
188N. Intro. to RF power amplifiers
1:19:14
Ali Hajimiri (Academy)
Рет қаралды 59 М.
RF Design-18: Practical Power Amplifier Design - Part 3
54:00
Anurag Bhargava
Рет қаралды 12 М.
Fundamentals of RF and mm Wave Power Amplifier Designs: Prof. Hua Wang
1:32:21
RF Design-6: Smith Chart and Impedance Matching Fundamentals
43:50
Anurag Bhargava
Рет қаралды 53 М.
Seja Gentil com os Pequenos Animais 😿
00:20
Los Wagners
Рет қаралды 88 МЛН