Double Glazing Unit Condensation / Blown DIY Repair.

  Рет қаралды 619,232

The Repairer

The Repairer

Жыл бұрын

#doubleglazing #doubleglazingrepair #diydoubleglazingrepair
Double Glazing Unit Condensation / Blown DIY Repair.
In this video I repair a failed Double Glazing unit that is suffering from severe internal condensation and damp. The unit was misted in the lower portion due to the water ingress. The glazing was taken apart thoroughly cleaned and resealed this took some time (circa 4 Hours).
Thanks for watching why not Subscribe to learn of more repair possibilities do work safely, video for illustration purposes.
Timestamps :-
00:01 Removal of the failed Double Glazing Unit.
02:45 Full extent of the moisture problem and deconstruction of the double glazing unit.
04:23 Removing the excess sealant from the internal aluminium frame.
04:50 Deconstruction of the internal aluminium framework and desiccant extraction and drying out.
06:00 Cleaning the Glazing panes to the best of my ability.
07:17 Refilling the internal aluminium framework with the dried desiccant.
08:10 Cleaning the framework and reassembly tips n tricks.
09:32 Sealing the Double Glazing unit back together.
10:48 Refitting the glazing.

Пікірлер: 1 000
@davesmith9325
@davesmith9325 11 ай бұрын
Its really depressing how many comments say "just go and buy a new one", *totally* missing the point. Repairing things is a great thing to do on many levels (eco, ethics quite aside from saving money) if you have the skill and inclination & no one is forcing anyone to do this against their will. Great repair well done!. I wonder if these people wash their clothes, dishes etc or just buy new ones.
@TheRepairer
@TheRepairer 11 ай бұрын
Agreed 100%, the real problem is fear of this repair leading to a downturn of business for those who stand to benefit. Eco credentials are likely discarded for profit and convenience. I’ve had the exact same problem with another video I made opening a stuck shut composite door that I strongly suspect has upset many a locksmith! They don’t want a video to be available to the masses that helps solve a costly problem they earn money from!
@johnd6487
@johnd6487 11 ай бұрын
I wouldnt have said that, but I have to admit I had no idea they were repairable. I had a hunch that there was a dessicant in the surround, but always assumed the air gap had some specific gas or vacuum treatment to minimise the condensation. I have a couple of blown units though. Now I've seen this i will certainly take the plunge on repairing them myself
@nonegiven9579
@nonegiven9579 11 ай бұрын
For most it basically boils down to valuing how much your time is worth? Stripping down a unit like that would probably take many about two hours to do , a new glazed unit is about £20 , so if you're time is worth more than £10 per hour you're better off buying a new unit. Appreciate the video though, found it interesting
@darthwiizius
@darthwiizius 10 ай бұрын
@@johnd6487 Bog standard double glazing now is argon filled, I just had some fitted because my old frames were falling to pieces. DG has improved but if you don't need to change them then fixing them makes sense. It takes donkeys years to get the money back, that's if you ever do before they fall to pieces again.
@Jack_Warner
@Jack_Warner 10 ай бұрын
@@darthwiizius Not all sealed units are argon filled. The point of the argon is supposed to reduce sound by 5%, but people don't realise that the sound is easy transmitted through the frame not the glass.
@jimp1646
@jimp1646 3 ай бұрын
It's good to see someone actually repairing something rather than just throwing it away and buying a new replacement.
@user-zw9ng1vg9m
@user-zw9ng1vg9m 7 ай бұрын
I used to make these many years ago so a couple of tips, when cleaning the sealant off use start with a new stanley knife blade to remove the bulk then brillo pads to lift the remaining old adhesive, when reassembling put the 2 panes in place with the spacer bar between and hold them in place with lots of large bulldog clips, drill a hole in a piece of wood and fit it to the end of the sealent nozzle so it fills the gap and smoothes the sealant at the same time moving the buldog clips as you go being careful not to push the spacer in with the sealant. The packers also function to hold the plastic frame square so they are usually on the hinge side at the bottom and the outside top. The dessicant doesn't just absorb water it bonds with it, you need to get it very very hot to drive the water off if its even possible, try the crystal cat litter thats in sealed poly bags and fresh. Adhesive aluminium tape will hold up to water better than duct tape and protect the sealed edges better
@TheRepairer
@TheRepairer 7 ай бұрын
Thanks I will perhaps amend my technique slightly based on this information. I love the block of wood tip!
@MrKamizz
@MrKamizz 7 ай бұрын
Tha what I call “nice reply”
@azash8154
@azash8154 7 ай бұрын
Really useful addition. Much appreciated 👍🏽
@Bond2025
@Bond2025 7 ай бұрын
Fascinating, I was completely lied to when I asked if I could have an extractor fan fitted in a rectangular double glazed unit. I was told no as there needs to be a vacuum between the glass!
@user-zw9ng1vg9m
@user-zw9ng1vg9m 7 ай бұрын
@@Bond2025 yep thats a lie, though no one wants to make them as its awkward sealing the unit, but no, no vacuum, glass is quite bendy and a vacuum would actually have the two glass panes touching in the middle on large units, some specialist units are filled with an inert gas but tbh i doubt its more than a sales gimmick
@normanboyes4983
@normanboyes4983 11 ай бұрын
Well done, fascinating to watch and I learned enough to know now - that I would not tackle this. As an engineer and accomplished DIY (and tight arse) I think that knowing what not to tackle is also valuable knowledge. Thank you.😉👍
@TheRepairer
@TheRepairer 11 ай бұрын
Thanks, I’m glad the video proved beneficial.
@waynetykocki3964
@waynetykocki3964 10 ай бұрын
Thanks I paid £170 for a panel like this to be replaced, after watching this I would be confident to do this. I don’t chase myself as a tight ass I just enjoy fixing things. As a lad I took an alarm clock apart fixed it and rebuilt it and it gave me immense pleasure. I also replaced the mineral glass in my Seiko watch with blue sapphire scratch proof glass and the aluminium bezel with a ceramic one. The next level seiko dive watch with these as standard are £300 more the upgrade cost me £35 so it’s both rewarding and saves you money. But also you can learn another skill.
@normanboyes4983
@normanboyes4983 10 ай бұрын
@@waynetykocki3964 Well done, you will not find me knocking anyone doing this repair - I just said not for me.😉👍
@jamesrussel1133
@jamesrussel1133 7 ай бұрын
I know what you mean. In my case it would either have fallen to the ground from a great height, or at leant one side would have cracked trying to get it on a large flat surface to clean it. So likely failure and a risk of injury through broken glass, then a panic trip to B&Q to get a sheet of ply cut to size to go in the frame for a week or two before the replacement unit came. Plus if warm moist air gets trapped in the air gap won’t you still get condensate within the glass on a freezing night?
@I_Don_t_want_a_handle
@I_Don_t_want_a_handle 7 ай бұрын
@@jamesrussel1133 before you seal it heat with a hair dryer?
@twotone3070
@twotone3070 Жыл бұрын
I don't understand why people go to the bother of watching a video on something they then spend time on telling you is not worth doing. He did it, he took the time to show others what's involved, someone can make there own mind up whether they want to do it. If there is additional information that can be added by commenting then this is valued, but just slagging it off as a waste of time or easier to buy a new one is completely missing the point of the video. Having said that, any interaction on YT is power to the algorithm, but just demoralising for the creator.
@TheRepairer
@TheRepairer Жыл бұрын
You have summed things up nicely many thanks.
@julesdowner5585
@julesdowner5585 10 ай бұрын
It is a waste of time though . Its a bad bodge . You can pretty much guarantee your windows are different to this one . The packersare in the wrong plave fora start , What if your window is not a top hung? . To buy the tools etc necessary to do this is as much as buying a replacement unit or more . Never try this unless you are experienced . This video will encourage people to open a can of worms . Its not worthwhile . Be my guest to try it , i did 30 odd years ago
@curmudgeon1933
@curmudgeon1933 18 күн бұрын
@@julesdowner5585 . Your name suits you. lol
@AnonAnonAnon
@AnonAnonAnon 7 ай бұрын
One bit of advice for any budding DIY'ers. When you remove the beading from around the glass, before removing the glass unit, measure it. I replace sealed units for a living. Many a time I get called out to blown units to replace with a new unit, and on trying to remove the old unit, if its stuck in fast (usually because the original fitter used tonnes of silicone, putty or even tacks to secure the unit on wooden frames) the unit can and does crack/shatter. This renders a DIY job useless and you'll end up purchasing a new unit. If this does happen, leave the old one in place, the outer pane may not have cracked until you get a new one to fit. Its reverse fitting, easy to do, make sure there are no retaining bolts sticking out of the uPVC window frame that can catch on the new unit.
@TheRepairer
@TheRepairer 7 ай бұрын
I like your thinking, strangely enough measuring before removing is the last thing I’m considering at the time but it’s quick and easy and worthwhile.
@stellasteve9972
@stellasteve9972 6 ай бұрын
Too long winded
@TheRepairer
@TheRepairer 6 ай бұрын
@stellasteve9972 Are you referring to the repair technique or the video?
@Stevo2140
@Stevo2140 2 ай бұрын
Kinda cool hearing how different places do stuff different in aus we dont use sillicone or putty on DGU's usually just blocks rubber n beads use sillicone for sealing float and lam tho and for sealing hackhouts to the frame instead of pack putty
@keep_digging
@keep_digging 7 ай бұрын
I was always lead to believe they were vacuum sealed units, amazing thanks
@combrogi
@combrogi 7 ай бұрын
They are with Argon so the whole thing is useless and will mist up
@TheRepairer
@TheRepairer 7 ай бұрын
@combrogi They are a dehydrated air double glazing unit.
@combrogi
@combrogi 4 ай бұрын
@@TheRepairer then they're very old and inefficient
@user-fq4qk9wz5k
@user-fq4qk9wz5k 10 ай бұрын
I’m impressed that’s dedication to art of not being wasteful because that must have taken up a fair bit of ur time and patience for that matter but more power to u for doing so u made fine job of that repair also luv ur laid back style of speech u sound like the type of guy that is never fazed by any situation great stuff
@katopeeps8564
@katopeeps8564 11 ай бұрын
Similar idea to Edward Doyle's below. I had the very same problem a few years ago. I'm a lazy person so I spent some time trying to figure out an easy way to solve it without removing the glazing unit from the window. And I did. With the side window open I removed the upper and lower locking plates in the edge of the window frame. This allowed me to see the black sealer edge of the glazing unit at the top and at the bottom. VERY carefully I drilled a hole (about 5mm) through the black sealer until the drill bit was visible between the 2 panes. I did this for the top and bottom. Then I got my vacuum cleaner and placed the hose against the top hole and let it suck away. This started removing the moist air from between the panes as dry air was sucked in through the bottom hole. After 10 minutes the water vapour was gone forever. Then I sealed the 2 holes with a sealer, and replaced the locking plates. As it happened, I did this on a sunny day when the sun was shining on the window, so that helped. Total time to do the repair was about 30 minutes. I hope this might help someone!
@TheRepairer
@TheRepairer 11 ай бұрын
An interesting repair technique, I’m really glad of worked out for you.
@akaWooders
@akaWooders 11 ай бұрын
That sounds like a great shortcut. One thing that occured to me is that isn't the misting up caused by a breaking of the seal, therefore, unless that hole is located and sealed won't it mist up as soon as the weather turns cold? I note you said you did this several years ago, which has got me scratching my head wondering how it's lasted so long. Cheers.
@markrainford1219
@markrainford1219 11 ай бұрын
@@akaWooders Must have got lucky and drilled exactly where the leak was. 😁
@akaWooders
@akaWooders 11 ай бұрын
@@markrainford1219 😆
@julesdowner5585
@julesdowner5585 10 ай бұрын
Rubbish .
@MultiKat33
@MultiKat33 Жыл бұрын
Some people enjoy “having a go” at mending stuff and get more pleasure than giving in and going for the easier option. Good on you for giving stuff a go. We are too quick to send stuff to landfill etc so seems much more enviro friendly. We live in such a throw away society. Can see its Not an easy job, tedious and longwinded but great when you get that feeling of achievement at the end. Well done 👏🏼👏🏼👏🏼👏🏼
@TheRepairer
@TheRepairer Жыл бұрын
That’s exactly the spirit the video was made in and representative of the whole channel.
@roybatty2030
@roybatty2030 9 ай бұрын
Great video, thanks. How great to see someone skilfully fix rather than scrap and replace.
@stuartroyle1402
@stuartroyle1402 11 ай бұрын
a man who knows his trade,top skills .thank you,ihave several to do that i installed 20 years ago.
@TheRepairer
@TheRepairer 11 ай бұрын
I’m winging it really, but I got a result!
@jameswelsh5672
@jameswelsh5672 11 ай бұрын
Great to see this. I never realized there was anything inside the frame.
@TheRepairer
@TheRepairer 11 ай бұрын
I understand the glazing desiccant is there to absorb any moisture from the manufacturing process.
@anthonymurphy6404
@anthonymurphy6404 7 ай бұрын
All my years looking at DIY videos on you tube this is the best by a mile, thank you very much👍
@TheRepairer
@TheRepairer 7 ай бұрын
Wow, Thanks for the compliment I am glad you enjoyed the video.
@andyregan7889
@andyregan7889 11 ай бұрын
Don't if i will ever do this but really happy to know how it's done thanks mate.
@r1273m
@r1273m 11 ай бұрын
That was a fascinating and informative video. I had no idea whatever how D/G units were put together nor the fact that they could be repaired. I certainly could not tackle a job like that. I recently had a D/G unit replaced, it was about 1m x 0.75m and cost me £90.00 all in. He came and looked at the job, measured up and returned a few days later with the replacement unit and fitted it. I thought that was not a bad price. I suspect you spent quite a few hours on that job plus materials. However, as you and others have said, it's not just about money.
@garrett69
@garrett69 6 ай бұрын
They can't be repaired properly like this. It WILL fail again.
@gypsygem9395
@gypsygem9395 6 ай бұрын
@@garrett69 and who's to say the new one won't fail?
@TimHollingworth
@TimHollingworth 7 ай бұрын
As a life time repairer I appreciate the effort that went into this fix. I recently had all my hardwood windows replaced with upvc. On attempting to liberate the glass from the frames without breakage, it was near 99% failiure. They used putty to fix the dg into the frames, which turned into concrete! I also attempted to seperate the individual panes, so i know how difficult the job would be to complete without damage. Also the aluminium seperators were extremely delicate. So, you did a great job, and I hope you get 10 more years out of your repair. A follow up video would be interesting. Good luck, you got my sub...
@TheRepairer
@TheRepairer 7 ай бұрын
Thank you Tim, it’s great to receive such a positive comment on this video. I can tell you that the window is still good since it’s repair in June and the other large one I did is good too. Maybe I will do a follow up video at around the one year mark, I have other panes that I first repaired in lockdown that are over 3 years old and still good. Thanks for the Sub they are all much appreciated and good luck with any future repairs!
@scottlamber6992
@scottlamber6992 7 ай бұрын
Brilliant video, thank you for sharing. I will be trying this on two blown windows when the weather gets better. 👍🏼
@TheRepairer
@TheRepairer 7 ай бұрын
Thanks for the feedback and good luck with your repair.
@ch5139
@ch5139 Жыл бұрын
Thanks for freely sharing your knowledge.👍
@TheRepairer
@TheRepairer Жыл бұрын
My pleasure!
@taurusthebulloutdoors2302
@taurusthebulloutdoors2302 9 ай бұрын
How many people saying it’s beyond my capabilities jeez it’s not that hard ! Informative video good work 👍😊
@johntisbury
@johntisbury Жыл бұрын
Thanks for this very interesting, I watched it even though I don't have any blown double glazing units!
@TheRepairer
@TheRepairer Жыл бұрын
Your not the only one that does things like that, incase your wondering I have done similar.
@michaelmckenna6929
@michaelmckenna6929 11 ай бұрын
GREAT INFO , MANY WILL NEED TO KNOW THIS IN THE FUTURE. THANKS
@alexiswolfe
@alexiswolfe 7 ай бұрын
Good work. I've made and fitted DG units and also split them to reuse the glass etc. Some sealants are very difficult to cut and remove but it's worth a go. Save money, save materials and get satisfaction from doing the job.
@TheRepairer
@TheRepairer 7 ай бұрын
Thanks it’s good to hear from someone with industry experience that’s in favour of these diy repair techniques.
@awalk5177
@awalk5177 7 ай бұрын
I learnt a lot from this video. My previous house had a few panels that were showing signs of blowing after probably 40 years. I had no idea they had desiccant inside the frame, and it did not look like too difficult a task, if you are capable and patient. The panels I had were into wooden frames, it was a house built in 1890 and had been upgraded a few times since WWII, so the windows were not original and extraction of the cells would have been slightly different. They were installed with putty and sometimes beading. Thanks for the information. I like to learn at least one new thing every day and today I learnt more than usual.
@TheRepairer
@TheRepairer 7 ай бұрын
I’m glad you enjoyed, Thanks for a positivity.
@Stevo2140
@Stevo2140 2 ай бұрын
Just a tip for ya if ya dont already know on timber hackouts and timber bead windows its a good idea to use sillicone to seal the windows in place instead of putty as putty likes to let go as it sets i only use putty on timber and steel hackouts on the outside of the glass
@markrainford1219
@markrainford1219 11 ай бұрын
Well done, you completely rebuilt the window. I know from experience how long it takes to separate the panes and clean them. (brake cleaner would have instantly removed the WD 40. Possibly the butyl rubber residue too?) I'm in the process of trying something similar, but attempting to do it without dismantling the unit. I've dug an inch of rubber out of the bottom of each side and got the dessicant out. My 'plan' is to reseal using butyl rubber glazing tape and a hot air gun, like torch-on felt roofing style. Also I do a bit of tig welding, so I've got an Argon bottle handy to Argon fill the unit while I'm at it. Never going to be as good as new, but it's an interesting exercise. (plus all my units are diamond leaded so flippin' expensive) something I did come across while researching; the dessicant isn't like silica gel that can be dried at low heat. It's called molecular sieve 3A, and needs to be reactivated at above 121 degrees Celsius. For future reference if you're interested, 110 litre disposable Argon bottle (Toolstation) and gas regulator (fleabay) total thirty quid. Anyhow, fingers crossed..
@TheRepairer
@TheRepairer 11 ай бұрын
I’m wishing you the best of luck with the repair, interesting about the gas I have a welder that can use it.
@nigel6862
@nigel6862 2 ай бұрын
All I need to repair 3 units in conservatory.. a big thank you.. just waiting for a dry sunny day!
@TheRepairer
@TheRepairer 2 ай бұрын
Best of luck with your repairs.I too hope the weather comes good very soon.
@cedarstuff
@cedarstuff 6 ай бұрын
Not an option I would choose, but great to have the knowledge out there.
@smudger25261
@smudger25261 7 ай бұрын
Excellent video i admire your patience and skill. It's always the so called experts who put down anyone that has a go!
@TheRepairer
@TheRepairer 7 ай бұрын
Thanks, I do try to ignore the pessimism and focus of the positives to be gained.
@curmudgeon1933
@curmudgeon1933 18 күн бұрын
Normally armchair experts who prefer to knock others efforts...and are probably just cack-handed, and screw up any job they attempt. Jealousy is a bitter fruit.
@briansmith7256
@briansmith7256 Жыл бұрын
Wow! I learned a lot there. Last year, I purchased replacement sealed units. I had no idea I could have done this. Definitely going to give it a go as I have another one gone. Thank you. 👍
@TheRepairer
@TheRepairer Жыл бұрын
Thanks Brian, I wish you the best of look with the refurb, just allow plenty of time and tool up well. The video is 4 hours worth of my labour and its not my first window!
@markthomasson5077
@markthomasson5077 Жыл бұрын
@@TheRepairer add the cost of the sealant, makes you wonder if it is cheaper just to get it replaced. Not that I don’t think what you did it an admirable piece of work
@TheRepairer
@TheRepairer Жыл бұрын
It all cost less than £10
@julesdowner5585
@julesdowner5585 10 ай бұрын
You can't do this unless you are extremely lucky . . Please do not attempt it. You can do more damage than you started with .
@horace9341
@horace9341 7 ай бұрын
@@TheRepairerNot when you consider the labour costs. False economy.
@IkeBrider
@IkeBrider Жыл бұрын
Nice job! I admire your tenacity!
@TheRepairer
@TheRepairer Жыл бұрын
Thank you very much!
@cyberphox1
@cyberphox1 Жыл бұрын
Thanks for sharing your knowledge.
@TheRepairer
@TheRepairer Жыл бұрын
My pleasure!
@waynenunn897
@waynenunn897 Жыл бұрын
This was absolutely fascinating. I had no idea these could be repaired like this. I think it is beyond my skill level however!! I also never realised there was desiccant in the units. That explains the little perforations in the aluminium I suppose.
@TheRepairer
@TheRepairer Жыл бұрын
Glad you enjoyed it!
@jamiewood4280
@jamiewood4280 11 ай бұрын
As a Yorkshire man, this video was perfect. Just make sure you pick a dry day to do it!
@TheRepairer
@TheRepairer 11 ай бұрын
Glad you enjoyed, never a truer word said regarding the dry day!
@martinwyke
@martinwyke 2 ай бұрын
That's brilliant, just takes care, time and some fine weather. 👍
@TheRepairer
@TheRepairer 2 ай бұрын
Fine weather is super important.
@colindobson2964
@colindobson2964 10 ай бұрын
Yes well done,like that glazing tool.
@brod5079
@brod5079 Жыл бұрын
Yowtyowb worked out I needed to see this. Literally about to order a few panels! Ta very much
@TheRepairer
@TheRepairer Жыл бұрын
Your welcome
@CarlGuymer1
@CarlGuymer1 11 ай бұрын
Nice! Give people the knowledge so they can choose to do their own repairs. Given the times we live in, I think more people will move back to basics and save money by doing their own repairs.
@TheRepairer
@TheRepairer 11 ай бұрын
Thanks I agree wholeheartedly.
@julesdowner5585
@julesdowner5585 10 ай бұрын
This is a bodge. Its a can of worms . If you are not experienced then do not attempt this please . Its an awful video
@MrDjalixx
@MrDjalixx Ай бұрын
Thanks to this superb video, I tackled my back French door with massive success! It did take most of the day but what a difference… I can now see our back garden 😂 The worst bit was cleaning up/removing the old black sealant. I found that using a hairdryer softened it right up and it came away much faster.
@TheRepairer
@TheRepairer Ай бұрын
Well done.
@alfiekay4808
@alfiekay4808 7 ай бұрын
Thanks pal. Good vid. I have lots of time but not much cash so now with this knowledge i will try to do the same so that i dont freeze this winter.
@TheRepairer
@TheRepairer 7 ай бұрын
Wishing you the best of luck
@adrianhorsnell8900
@adrianhorsnell8900 11 ай бұрын
A good job well done and very well explained, you've clearly saved yourself a lot of money and avoided the unit having to be destroyed for recycling. The fizzing you saw with the Vinegar and Soda Bicarb was the reaction between Acetic acid (from the vinegar) and the bicarb which releases Carbon Dioxide. Did you consider using a household detergent (eg washing up liquid) to remove the traces of WD40? Once again thanks very much - it's useful😊 to know that that can be done.
@TheRepairer
@TheRepairer 11 ай бұрын
I didn’t consider a detergent as the white vinegar seemed to eradicate all traces of it after the multiple passes that were required to clean up the window panes.
@julesdowner5585
@julesdowner5585 10 ай бұрын
Its a bodge , , a dreadful video made by someone who isn't trade and seen by people without a cluev. Never attempt this, it is pointless unless your window is in a shed . Get a new one made and fit it yourself , Which is a lottery in itself
@bigchrisrogers
@bigchrisrogers Жыл бұрын
Thank you very much, practical and detailed without the waffle that so many seem to put into this kind of instructional video, well done.
@TheRepairer
@TheRepairer Жыл бұрын
I’m glad you enjoyed it, Thanks
@julesdowner5585
@julesdowner5585 10 ай бұрын
Its a bad bodge . Never attempt this .
@nairagasparetto
@nairagasparetto 4 ай бұрын
Great video! Thank you so much for teaching us!
@TheRepairer
@TheRepairer 4 ай бұрын
Glad you enjoyed it!
@MarwanPati
@MarwanPati 3 ай бұрын
Good job. After this winter I have plenty windows that went foggy :/ it seems like I will have a lot of work when it will get warmer. Thanks for the tutorial!
@TheRepairer
@TheRepairer 3 ай бұрын
Your welcome, Good luck with your repairs.
@Umski
@Umski 10 ай бұрын
Nice job! I'm surprised you were able to get the inner beads off without first removing the outer seals - I found it to be impossible to do without doing this first. It seems that south facing windows seem to suffer this problem the most - I had 6 or 7 panes with condensation like this, all south facing and ended up going down the replacement route (bungalow with around 30 units in total!) albeit did it myself - the new glazing has a u-value that is around half of the old panes and argon filled so far better thermal insulation, though I expect a similar lifespan - it's a tough dilemma as the glass itself is fine, the weakness is in the seal and the dessicant which fails after around 10 years but the difference in thermal efficiency has been amazing - I still have all the old units and hope to be able to re-purpose them either into a project or for someone else - it's the glass that has the highest embedded energy after all...
@TheRepairer
@TheRepairer 10 ай бұрын
I think you could be onto something with the south facing failures!
@horace9341
@horace9341 7 ай бұрын
It all depends on how the unit is glazed. Some of the older windows are glazed without gaskets, then a wedge gasket is pushed in after the beads are on. More modern windows have a co-extruded gasket on the frame and beads. Not all window systems are the same, some have a double fin bead, but again the more modern ones have a single fin bead system.
@dmdbailey1
@dmdbailey1 11 ай бұрын
Demystified double glazed units in more than one way. The vinegar and bicarb acts as a very good degreasant for the WD40. The application of the silicone, as you did- the careful pushing of the sealant into the joint after thorough cleaning of all surfaces, will seal the units for a good long time. Obviously if someone is tempted to simply trowel the wet silicone edges then they can expect failures as the retired glazier suggested. Re-using desiccant is done extensively in science- there's no magic to it- though do it for longer than the simple appearance of whiteness to ensure all interior moisture has been driven off.
@TheRepairer
@TheRepairer 11 ай бұрын
I’m impressed you have paid so much attention to detail. It’s really good to receive such a positive comment from a fellow believer in the repair process.
@hamzah3138
@hamzah3138 7 ай бұрын
Thank you sharing 👍 I've book marked this and will definitely have a go 💪
@TheRepairer
@TheRepairer 7 ай бұрын
I hope all goes well, and you get a great result.
@therealspixycat
@therealspixycat Жыл бұрын
Thank you very much: I was considering this but never seen the entire process.
@TheRepairer
@TheRepairer Жыл бұрын
Most welcome
@RogerM9
@RogerM9 7 ай бұрын
Good video, and well done you for giving it a go. If time is money, then a new sealed unit is the way to go, but there are plenty out there who have time on their hands, or no money - in which case this is for you. All I would add is that I would have a piece of sterling board or similar to hand in case I cracked the glass. The glass and the aluminium spacer will expand and contract at different rates with temperature changes, so use a low-modulus silicone, which allows the glass and spacer to move against each other without breaking the seal. Make sure there are packers underneath the glass so that the units never have to stand in water. Also try and do it on a cold dry day so that the air that gets sealed inside will be dry, giving the desicant less work to do. Avoid hot humid days! If it works, you've saved a considerable amount of money. If it doesn't, you're down to the tune of one tube of sealant, and we've all got a bit of gash sterling board lying around, and regardless of whether it works or not, you'll have learned something new. If you don't have a go, you've learned nothing. Now wait for those who have trolled this thread multiple times at every opportunity to wade in!!
@TheRepairer
@TheRepairer 7 ай бұрын
I get much pleasure from finding low cost solutions for problems even though I don’t need too!
@MrMarketboy
@MrMarketboy Жыл бұрын
A great practical guide, well done.
@TheRepairer
@TheRepairer Жыл бұрын
Glad you enjoyed it!
@RichDavey
@RichDavey 4 күн бұрын
Superb job A lot of effort has paid off here Well done 👍
@paulollerhead
@paulollerhead 7 ай бұрын
Fantastic job sir. I’ve worked in this industry for years and didn’t know about the desiccant in the spacer 😂
@TheRepairer
@TheRepairer 7 ай бұрын
I’m glad you enjoyed.
@LittlePixelTM
@LittlePixelTM 7 ай бұрын
I always thought that the two glass panes had the air sucked out of the void between them before they were sealed at the factory - ie that there is a vacuum between the panes, so this was an eye opener. If it wasn't October I would be tempted to try this on one of our blown ones.
@TheRepairer
@TheRepairer 7 ай бұрын
The weather does need to be onside, I have waited weeks to find the perfect day when I am available to do this and the weather is bone dry! I had to do the last one indoors because the weather app lied to me and it rained!
@jamesrussel1133
@jamesrussel1133 7 ай бұрын
You can get sealed units like that, failed seals, when air laden with moisture gets inside, that’s when condensation occurs.
@Pugjamin
@Pugjamin 7 ай бұрын
You could purge fill them with argon, which is what most have from factory.
@danielandjenny9
@danielandjenny9 7 ай бұрын
Absolutely love the enthusiasm and work ethic to get that fixed But that being said £40 for a new unit that size is much easier for the amount of time and effort to split a unit down … nice work tho mate ..
@TheRepairer
@TheRepairer 7 ай бұрын
Fair enough!
@lawrencecopeland9366
@lawrencecopeland9366 6 ай бұрын
@@TheRepairer £40 for a new unit of that size, you can put a 100 in front of that 40 if not more +vat
@paulfredfield
@paulfredfield 2 ай бұрын
I never knew they could be fixed. We need to fix/replace a load of them…. Big and heavy so a bit above my pay grade unfortunately, but thanks for this great video!
@catabaticanabatic3800
@catabaticanabatic3800 7 ай бұрын
Wow. I never knew that there was dessicant in the frame. Nice job. I will deffo have a go at that when the inevitable happens.
@TheRepairer
@TheRepairer 7 ай бұрын
Best of luck with it.
@andru9102
@andru9102 11 ай бұрын
Thank you. Helpful video to inform me that I will replace rather than repair my failed double glazed window units!😂 Hats off to you for the effort though, good result in the end 👏🏻
@TheRepairer
@TheRepairer 11 ай бұрын
You are welcome.
@wendyjones3953
@wendyjones3953 9 ай бұрын
Sometimes £50-£99 is NOT cheap! As a family who have moved a dozen times, we always called a glazier when the panels ‘blew’ BUT due to energy AND fuel costs etc., we are just accepting the fact that the couple of failed panels we have at the moment will be there for the foreseeable future. We aren’t brave enough to try to mend them ourselves in case we make the problem worse.
@tooyoungtobeold8756
@tooyoungtobeold8756 6 ай бұрын
That's me. I don't think a blown window has less insulation properties. Perhaps allow more noise though.
@laurencegoulty3196
@laurencegoulty3196 Жыл бұрын
I never thought about doing this, but I have a misted fanlight at the moment so will be giving this a go. I hope your pane was a success and is still mist free.
@TheRepairer
@TheRepairer Жыл бұрын
Best of luck and yes it is still mist free.
@oswaldoparedes8463
@oswaldoparedes8463 7 ай бұрын
Absolutely brilliant, thank you so much
@TheRepairer
@TheRepairer 7 ай бұрын
You're very welcome!
@Lyndalewinder
@Lyndalewinder Жыл бұрын
Wow very impressive technique and video but it looks like many hours of work. I think I would just get a replacement sealed unit. Thanks for posting.
@TheRepairer
@TheRepairer Жыл бұрын
Great point!
@daglen
@daglen Ай бұрын
Thank for your videos. Gave it a go and happy with the result. Just make sure you really clean the glass that will be inside the seal. Rinse several times to get all the cleaning chemicals off the glass or they may appear a couple of days after the unit is in the frame. This happened to me after the wife cleaned the glass and insisted the small streaks are not cleaning chemicals and that the glass is damaged. I will now repeat the repair on the same unit and clean the glass myself to see if the glass expert is right😂 I will let you the outcome when I get it done. The time v buy new isn’t the issue for me. I really enjoy the satisfaction of doing things myself and learning new skills. Once again thanks for the video one of the best on KZbin on this subject.
@TheRepairer
@TheRepairer Ай бұрын
Thanks for the feedback, I am wired that same way. I could buy new but where is the fun in that. I’m pleased that you have successfully repaired your window.
@cressytisswuff
@cressytisswuff 10 ай бұрын
Bloody good job!
@winniewotsit4452
@winniewotsit4452 Жыл бұрын
Excellent - well done. Where's there's a will - there's a way.
@TheRepairer
@TheRepairer Жыл бұрын
So true
@michaelfrench5252
@michaelfrench5252 Жыл бұрын
No where's there a will there's a relative 😂
@winniewotsit4452
@winniewotsit4452 Жыл бұрын
​@@michaelfrench5252 Good one Mike! :)
@edwarddoyle9231
@edwarddoyle9231 Жыл бұрын
Hi, very good video & perfect work - i had a similar problem with two of my windows - lots of water / moisture between the two window panes & just out of guarantee - fortunately for me they were of the opening type window - i cleaned out the drain vents at the bottom of the outer frame’s & used a vacuum cleaner on them to make sure they were free. I then drilled two 4mm holes up at the bottom of the main window frame up between the glass panes & one 4mm hole near the top on both side’s again between the glass panes. I put a short length of tube ( earth sleeving ) on the vacuum cleaner , removed all the water & left to to air dry. That was last year - no more water or moisture - apart from just a couple of white plastic flakes that fell inside. Ed,
@TheRepairer
@TheRepairer Жыл бұрын
That’s an interesting repair thanks for sharing , I did hear of company that drilled holes and filled them with vent plugs.
@hayleyhall5766
@hayleyhall5766 Жыл бұрын
Fantastic video 👍 u need to do a radio station your voice is r8 relaxin
@TheRepairer
@TheRepairer Жыл бұрын
Thanks, that’s never been said before.
@gerrabath
@gerrabath 7 ай бұрын
Yielded an improvement. Brilliant! 😁
@TheRepairer
@TheRepairer 7 ай бұрын
Thanks, It wasn’t easy but the clear vista is worth the effort!
@terryknowles1
@terryknowles1 11 ай бұрын
As a retired Glazier with over 35 years experience, I can honestly say I would be surprised if that repair lasted a year using silicone to seal it and reusing dried desicant. To be honest you were lucky not braking at least 1 of the panes getting it apart.
@TheRepairer
@TheRepairer 11 ай бұрын
I did my best to avoid breakage’s.
@raylp4751
@raylp4751 11 ай бұрын
20yrs service Engineer fitter. I agree. So much more to criticise here. The packing just for starters. See other comment.
@franklettering
@franklettering 11 ай бұрын
Syndicalist minded people always feel hurt when someone competent achieves success.
@TheRepairer
@TheRepairer 11 ай бұрын
Thanks I gave it my best shot!
@Lloyd1885
@Lloyd1885 11 ай бұрын
Interesting, but a new sealed unit that size isnt that expensive...
@andyetheridge
@andyetheridge Жыл бұрын
Repairs like this won’t last, 25 years experience taught me that!
@TheRepairer
@TheRepairer Жыл бұрын
The original factory window unit didn’t last either, hence the repair!
@julesdowner5585
@julesdowner5585 10 ай бұрын
You are correct , its a bad bodge video . Anyone in the trade will tell you . I wouldn't reccomend anyone even take the glass out for they may do more damage to the window!
@SuperBicycleRepairMan
@SuperBicycleRepairMan 7 ай бұрын
Well done, fantastic tutorial
@TheRepairer
@TheRepairer 7 ай бұрын
Thank you! Cheers!
@user-bu7gz1es7s
@user-bu7gz1es7s 6 ай бұрын
I'm a Carpenter, and thanks for this information. I did not know you could do this. As I thought they were gas sealed
@TheRepairer
@TheRepairer 6 ай бұрын
That is just a basic dehydrated unit the high end stuff can be gas filled.
@christopherwilson4003
@christopherwilson4003 Жыл бұрын
I used to be a window fitter commercial n domestic. And I've seen sealed units being made ...Youre video was very good. Would give people the confidence to try it themselves I'd also use new desiccant (Silica balls that absorb water and moisture).Im pretty sure that once they reach the end of their life that's it. You're heating method would work for a short period. Hope u don't mind me saying that. Because I'm not knocking what u did .Just trying to help is all
@TheRepairer
@TheRepairer Жыл бұрын
Your opinions are appreciated and valued,many thanks.
@christopherwilson4003
@christopherwilson4003 Жыл бұрын
Thanks
@neilrobinson7965
@neilrobinson7965 11 ай бұрын
@@TheRepaireri think there is nothing wrong with the oven drying of the dessicant. Years ago, i worked in a chemistry lab which did gas chromatography and one of the things we needed to do was to dry the compressed air from a Compressor. To do that the air was filtered through molecular sieve cartridges which contained the same stuff as is used in the double glazing. We used to recondition it by drying in an oven overnight and repacking the cartridges. It was the recommended procedure and worked fine.
@julesdowner5585
@julesdowner5585 10 ай бұрын
Its a rubbish video, did you notice its a tilt and turn window?
@DriverOfAirbus
@DriverOfAirbus 7 ай бұрын
Very watchable video BUT what did you do about the vacuum between the two panes? Double glazing is an effective insulator and gets it's strength from the vacuum between the two panes making it as if the void was a single solid thickness from the inside to the outside. By not creating a vacuum your u-value (insulation measurement scale) will be extremely poor, costing more in heating and noise transference. Likewise, it will be massively weaker if struck by a ball or a burglar. As I say, respect for having a go but unfortunately on this occasion, missed the mark significantly.
@TheRepairer
@TheRepairer 7 ай бұрын
It’s not vacuum double glazing (VIG) just a standard double glazing unit consisting of dried air as the insulator.
@colinwilson210
@colinwilson210 7 ай бұрын
​@@TheRepairerwell bugger me, I was under the impression all double glazing had a vacuum ! I'd been trying to work out if there was an easy way to emulate it (at least partially), perhaps by sealing all but one small section, then heating the glass (hair dryer) to expand the air inside (which would vent out of the opening), then sealing the gap before it cooled down.
@ianmarsden8568
@ianmarsden8568 7 ай бұрын
Never knew this is how these work and can be repaired. You can tell you're a fixer and like working things out, you've got a trailer! Like videos like these, you remind me of a channel called Marty I watch an NZ youtuber. Cheers. Liked and subbed.
@TheRepairer
@TheRepairer 7 ай бұрын
Thank you, I do my level best to repair things and your comment is much appreciated and makes being on KZbin more worthwhile to me.
@Mark-cd3vd
@Mark-cd3vd 7 ай бұрын
super mate! patience and dedication
@TheRepairer
@TheRepairer 7 ай бұрын
Thank you, much appreciated
@fraclarke6523
@fraclarke6523 Жыл бұрын
As a qualified Professional Glazier of 45 years at the trade , No way would I recommend anyone trying this unless you know what you’re doing !!
@cyberphox1
@cyberphox1 Жыл бұрын
Why?
@fraclarke6523
@fraclarke6523 11 ай бұрын
No harm in me trying to give someone a piece of advice , sorry I offended someone of your esteemed knowledge in all types of craft and skills , won’t happen again , ( just scroll past me in future 👍)
@Jack_Warner
@Jack_Warner 10 ай бұрын
One other thing you should do is when you're sealing it all up, you should place bulldog clips around it. This holds the glass tight against the spacer bar and helps to give an air tight seal.
@TheRepairer
@TheRepairer 10 ай бұрын
A good tip thanks.
@djg2315
@djg2315 7 ай бұрын
Excellent work. Keep it up.
@TheRepairer
@TheRepairer 7 ай бұрын
Thanks, will do!
@victatur6908
@victatur6908 Ай бұрын
Good Job, I learned a lot. Now I will try to fix one of my windows that has condensation. Thanks again
@TheRepairer
@TheRepairer Ай бұрын
Good luck.
@eddjordan2399
@eddjordan2399 7 ай бұрын
very interesting but inst the whole point of double glazing is there is argon gas inside the void that makes the window thermally efficient?
@TheRepairer
@TheRepairer 7 ай бұрын
Argon is some but dried air is more common.
@user-et6bz7jm3i
@user-et6bz7jm3i 10 ай бұрын
Thank you! I have lots of units like this, I’m going to give it a go!
@TheRepairer
@TheRepairer 10 ай бұрын
Good luck!
@julesdowner5585
@julesdowner5585 10 ай бұрын
Don't do it!. unless you have window experience . . better to buy replacement units. This is a bad idea .
@bobit8360
@bobit8360 6 ай бұрын
Wow been wondering y the condensation in my front window duz that well now a no tip top job 👍
@sidguernsey1393
@sidguernsey1393 Жыл бұрын
Great video and fair play for a good result. I have to be honest, the best advice was how to remove and fit the pane, if you order just a replacement pane through a glass wholesaler you'll save a fortune! The rest is a bit hardcore, to many ways for me to make a mess of it 🙂
@TheRepairer
@TheRepairer Жыл бұрын
Glad you enjoyed, Thanks
@lawrencenoctor2703
@lawrencenoctor2703 10 ай бұрын
Respect mate, fantastic job fearlessly taken on. I was astonished when you started to dismantle the whole thing. How long did it take in total?
@TheRepairer
@TheRepairer 10 ай бұрын
Thanks, the job took around four hours done at a leisurely pace with a couple of tea breaks thrown in!
@kirkby0076
@kirkby0076 6 ай бұрын
@TheRepairer Yeah, that's where most would lose patients & just buy one, because they would assume, it might only take time of the video + the drying out time in the oven. Hello Round Brands! Haha... 👍😉👍
@TheRepairer
@TheRepairer 6 ай бұрын
Yes I know someone who used assume the length of the video was the time it took to do the job! When making videos you have to consider the attention spans of the viewers some are surprisingly short!
@kirkby0076
@kirkby0076 6 ай бұрын
@@TheRepairer Indeed, Indeed 👍😉😁😉👍
@derektierney1314
@derektierney1314 7 ай бұрын
Great video as I was always wondering if this was possible to do, tks for the upload 😉👍
@TheRepairer
@TheRepairer 7 ай бұрын
Any time!
@Crushitchannel
@Crushitchannel 6 ай бұрын
I see that you have a very wide spacer frame in the double glazing, so I thought it wouldn't be a bad idea to look at acoustic double glazing, because I don't think it would matter if it were a little narrower. And i reccomend this configuration: 10mm float / 10mm spacer / 8,4 or 8,8mm laminated glass
@Moosequito573
@Moosequito573 Жыл бұрын
How well will they perform though? I thought double glazed units are filled with a gas or vacuum to create a barrier. Obviously this isn’t possible repairing them like this. Great video.
@TheRepairer
@TheRepairer Жыл бұрын
Thanks, I did a couple at least two years ago and they are still good and dry.
@Moosequito573
@Moosequito573 Жыл бұрын
Do you get condensation in the winter?
@TheRepairer
@TheRepairer Жыл бұрын
No they are both good
@Moosequito573
@Moosequito573 Жыл бұрын
Thanks. I’m going to give this a go. 👍
@matthewwakeham2206
@matthewwakeham2206 Жыл бұрын
Some expensive ones are argon filled but there is no vacuum. The trick is in the gap size of 12-16mm which prevents convection currents forming in the trapped air. That's what I heard anyway!
@garyherberson8119
@garyherberson8119 Жыл бұрын
This wouldnt work for low e-glass as you would remove the coating from the glass. Fair play for fixing your own window though. A new argon filled unit of that size would be around £80.
@TheRepairer
@TheRepairer Жыл бұрын
I’m now reading up on low e-glass, thanks for making me aware of it.
@markthomasson5077
@markthomasson5077 Жыл бұрын
Surely it would still work, just not be as efficient as the original, but of course still an improvement on the blown unit
@garyherberson8119
@garyherberson8119 Жыл бұрын
@@markthomasson5077 One of the manufacturing processes of low e-glass is a microscopic, almost transparent coating on the inside of the glass surface. If this were to get rubbed or scratched off, this would be like having scratched sun glasses. Not great, but yes- still usable. The bigger problem would be the thermal conductivity of the unit. My old 20mm double glazed units had a U value of 2. A new low e-glass argon filled unit near a u value of 1. In layman’s terms, a new unit is 100% more efficient at keeping the heat in your home (heat loss through the glass). I worked out that the cost of replacing my windows myself had a payback of 10 year (less if yyou take into account compound interest on savings and ever increasing fuel bills).
@hpt08
@hpt08 11 ай бұрын
@@garyherberson8119 surely the low U value comes from the inert gas filling rather than the tint preventing solar gain?
@murdo_mck
@murdo_mck 11 ай бұрын
There are two types of low E coating. A soft one which is easily scratched and a very hard one which is baked into the glass at very high temperature. Argon has no connection with low E, it just increases the thermal insulation compared to air fill.
@markhaith4720
@markhaith4720 11 ай бұрын
Thanks for your reply thats very helpful
@TheRepairer
@TheRepairer 11 ай бұрын
Any time
@kevinmoore7255
@kevinmoore7255 11 ай бұрын
This now gives me the confidence to give it a go as I have one unit that needs re doing! Many thanks !
@TheRepairer
@TheRepairer 11 ай бұрын
Best of luck and go carefully.
@RodPascoe
@RodPascoe Жыл бұрын
Fair play for your skill level but a replacement unit would be around £40 and can be replaced in just a few minutes. Depends if you value your time more than £40 for a few hours I guess.
@TheRepairer
@TheRepairer Жыл бұрын
Sometimes the excitement of the chase combined with a good degree of curiosity can outweigh the economics of replacement.
@TheSuperstar0780
@TheSuperstar0780 Жыл бұрын
Think you could spend just as long looking trying to find a cheap deal with a product that matches then installation etc, I have the same problem in my Kitchen for a much larger window that's not so easily replaced.
@garyherberson8119
@garyherberson8119 Жыл бұрын
£40? Do you live up north because London would be £100 (at least) and online £80
@RodPascoe
@RodPascoe Жыл бұрын
@@garyherberson8119 I’m out of date then as I replaced mine 3 years ago and they were cheaper. I’m in Cornwall.
@shed.projects5150
@shed.projects5150 Жыл бұрын
You are obviously not retired. When you are, you will be more than happy to spend a lot of your time saving money you haven't got.
@blakeyonthebuses
@blakeyonthebuses Жыл бұрын
Great idea. The double glazing companies are a total rip off!
@TheRepairer
@TheRepairer Жыл бұрын
I think we are on the same page.
@Christopher_T_Paul
@Christopher_T_Paul 7 ай бұрын
I recently changed 3 condensated units myself, I paid £110 for 2 comparable units to yours and a 1.5m x 1m unit. Whilst it wasn't a bad price, I still have some small openers that were expensive to replace because of the custom design and I think I will try this repair in the summer. The glazing supplier did deliver the units, but I had to dispose of the old units and that is easier said than done, my local recycling centre refused them and I had to travel 30 miles to go to a site willing to accept them.
@TheRepairer
@TheRepairer 7 ай бұрын
That’s quite a good price from the information I have received via the comments on this video, better than I expected. It’s disappointing that the recycling centres are being awkward regarding disposal. Good luck with your future repairs.
@Christopher_T_Paul
@Christopher_T_Paul 7 ай бұрын
@@TheRepairer We have several manufacturers locally, so I go direct to them. No doubt the people here are paying for someone to come out and measure them. As long as you remove the trim to expose the unit and measure exactly, you will be fine.
@sobeit1927
@sobeit1927 7 ай бұрын
I’d never even thought to repair them , looks pretty straight forward and I’ll try on a couple of mine . One thing though , I think using your thumb to press in the sealant is just asking for a cut thumb . Either a good glove or better still , create a tool of some kind for a pro finish and a happy thumb .
@TheRepairer
@TheRepairer 7 ай бұрын
Your right about the thumb, I shouldn’t have done that as glass can be sharp, fortunately this pane wasn’t but others if repaired since have been. Thanks for viewing and taking the time to comment.
@wackojacko4910
@wackojacko4910 Жыл бұрын
11/10 for effort, but I don’t think this is a good idea on many levels. High chance of glass breakage. Tape is applied to the perimeter of float glass because of the sharp edges, so you really don’t want to wipe your fingers around the edges. Glass isn’t packed properly, should be heel & toed, and stood on bridging packers. I’m doubtful this ‘remedy’ will pass the test of time. Buy a new unit & have a warranty on it.
@TheRepairer
@TheRepairer Жыл бұрын
A balanced comments section is most valued, thanks for taking the time to communicate.
@andrewclarke18229
@andrewclarke18229 Жыл бұрын
Heel and toed 😂😂😂😂
@rickspa8348
@rickspa8348 7 ай бұрын
I’m pretty sure I would have moved me car before taking the glass out… just in case..!
@TheRepairer
@TheRepairer 7 ай бұрын
The car wasn’t directly beneath the window it must just look like that in the video!
@bobthebuilder2967
@bobthebuilder2967 2 ай бұрын
Mint video m8 will certainly give mine a go thanks 👍👍
@TheRepairer
@TheRepairer 2 ай бұрын
Best of luck with it pick a good day.
@grahamosborn-yj3vx
@grahamosborn-yj3vx Жыл бұрын
Superb video thank you👍👌
@TheRepairer
@TheRepairer Жыл бұрын
Your most welcome
@donkeytrousers
@donkeytrousers 11 ай бұрын
I have never seen anything like it! People: don't do this. It won't last 5 minutes!
@TheRepairer
@TheRepairer 11 ай бұрын
Feel free to elaborate further.
@donkeytrousers
@donkeytrousers 11 ай бұрын
@@TheRepairer 1. A properly made insulating glazing unit has a primary and a secondary seal. The primary seal is there to seal the cavity and keep moisture out of the unit. The secondary seal (in the place where you put the silicone in the video) is designed to hold the igu together while allowing expansion and contraction as occurs naturally. Your unit has no primary (moisture) seal. The silicone might hold the unit together, but it would need to be applied properly. Your technique of pushing the tube behing the silicone flow will result in air bubbles and an inconsistent fill. 2. If your igu had a coating inside, you would have damaged it while cleaning it. These things cannot be done by hand when dealing with such complex products. The use of an acetoxy silicone would also have damaged the coating and may be incompatible with the aluminium spacer tube. 3. Your cleaning process could not have ensured that there are no airborne contaminants or worse, organic particles inside the cavity which could start to grow once you "seal" them in: especially since your lack of primary seal will likely allow moisture into the cavity in short order. Of course, you might get lucky. I worked in the glass industry for 26 years and have seen thousands of units made. If you visit an igu manufacturing facility you will see exactly what I am talking about. The level of investment they make in high quality sealants and the machinery to manufacture igus is testament to the need for absolute cleanliness and attention to detail. The process of making (or remaking) an Insulating Glazing Unit is far too complex to be udertaken at home if you want it to last.
@TheRepairer
@TheRepairer 11 ай бұрын
Better put, but I’ll gamble on doing the job for less than a tenner!
@edwardmurdoch1062
@edwardmurdoch1062 Жыл бұрын
Far easier just to replace with new unit and could be dangerous for someone who is not working with glass on regular basis.
@detiex5576
@detiex5576 Жыл бұрын
You could make this a new video for the Edward Murdoch repair channel just to show how much easier it is.
@edwardmurdoch1062
@edwardmurdoch1062 Жыл бұрын
@@detiex5576 Having worked with dg units on many occasions and seen them breaking for no apparent reason I would rather not. 🤷‍♂️
@marklaithy6960
@marklaithy6960 Жыл бұрын
If glass is toughened could shatter just with sharp blade or a little bang on the edge with your metal utensil. Wouldn't advise this repair tbh
@mrskint55
@mrskint55 Жыл бұрын
IMHO it’s not worth risking do this I worked I. The double glazing industry for over 30years .My advice is DONT TRY THIS .just buy a replacement unit. .
@TheRepairer
@TheRepairer Жыл бұрын
A balanced comments section is most valued, thanks for taking the time to communicate.
@semilife
@semilife 11 ай бұрын
Great video. Never knew what to do before.
@TheRepairer
@TheRepairer 11 ай бұрын
Thanks, I’m glad you enjoyed
Double glazing repair - condensation
7:57
Edd In The Shed
Рет қаралды 47 М.
Say Goodbye to Rising Damp - A Simple Solution!
8:21
Skill Builder
Рет қаралды 564 М.
He tried to save his parking spot, instant karma
00:28
Zach King
Рет қаралды 19 МЛН
ONE MORE SUBSCRIBER FOR 6 MILLION!
00:38
Horror Skunx
Рет қаралды 15 МЛН
The delivery rescued them
00:52
Mamasoboliha
Рет қаралды 6 МЛН
The Argon Gas Trick - Window Salespeople Tell Funny Stories
12:04
TheWindowDog.com
Рет қаралды 104 М.
Foggy Double Pane Window Fix!
7:16
Things Humans Do
Рет қаралды 301 М.
miwindowguy - Satisfying Techniques and Useful Tips
5:31
get the mist out. Condensation in Double Glazing, get the fog out
5:18
get the mist out
Рет қаралды 2 МЛН
Euro Lock Removal and Snapping
11:01
Proper DIY
Рет қаралды 702 М.
Why Millions Get Silicone Caulk Wrong
5:23
The Aiden Project🔨
Рет қаралды 653 М.
How to fix a crack in a wall or ceiling - DIY
13:01
Billshowto
Рет қаралды 7 МЛН
DIY Misted / Blown Double Glazing Repair Large Window.
18:19
The Repairer
Рет қаралды 48 М.
Double Glazing! The Little unknown Truths.
11:05
Efficiency Matrix
Рет қаралды 131 М.
Smart girl 😱🤢 LeoNata family #shorts
0:23
LeoNata Family
Рет қаралды 8 МЛН
Пранк над МАМОЙ
1:01
Ивета Кочконян
Рет қаралды 3 МЛН
Left or right little granny #shorts by Secret Vlog
0:29
Secret Vlog
Рет қаралды 4,2 МЛН
Sigma girl don’t think about stray animals😔
0:35
mountainlion5
Рет қаралды 13 МЛН
СИМВОЛИЧНОЕ ИСКУССТВО
0:28
В ТРЕНДЕ
Рет қаралды 3,4 МЛН