Process Design Engineering Course. Register Right Now!👇 banyantreelearning.com/admission/
@murulim1965 Жыл бұрын
How simply you explained my long pending doubt / question, Thank you sir
@rajesh2oman Жыл бұрын
great and simple
@mawaddatali41848 ай бұрын
So nice way of understnd.thaks
@zeineb8870 Жыл бұрын
Thank you for the explanation! Is a feed and Bleed operation the same thing?
@chemhassan Жыл бұрын
i wonder, what about the NH3 that already passed the 2nd I/V going to the pump. is it pumped entirely (but i think pumping this way will damage the pump as it only accepts liq or there is no air? ). im confused tbh
@Coreengineers Жыл бұрын
Liquify it first via providing steam then drain completely it could be easily ensured from the drain line....then only close the valve to give to maintenance.
@amitkumar-sh2lk4 ай бұрын
it is being used in iocl. in tank inlet outlet. so that oil should not leak
@manikmule Жыл бұрын
But if we are doing maintenance of Pump, then is it really necessary to bleed this small portion in between two i/vs, as per my understanding after right hand side i/v, there is drain valve arrangements, or else for extra precousinary measure at bleed valve, is there slope necessary ??
@Coreengineers Жыл бұрын
It's depends on process requirements...yes you must bleed that valve when you're stoping the pump or doing changeover so that any traces could be escape
@sjcho15052 жыл бұрын
Thank you for your explanation. Just one quick question. Do we drain NH3 to safe place through the bleed valve? I just want to know how to drain NH3 safely. Do we have to install tubing line to connect from the bleed valve to safe place?
@Coreengineers2 жыл бұрын
we bleed it and sent to tank(where waste ammonia soln will come) so that it could be recover again via reaction to produce urea.
@tisdale36 Жыл бұрын
We use these for phosgene, we have a vacuum system we call an evacuation that we hook to the bleed and it's always sucking on it.
@escapade96572 жыл бұрын
What if block valve found passing after isolation
@Coreengineers2 жыл бұрын
it depends which block valve is passing if first one then close the upstream i/v and if second one then close first one ensure there is no gas from the bleed i/v. if both then close the upstream i/v of the first one! Hope you got the point!
@solankiajendrakumar76072 жыл бұрын
Why not just used one single block valve in this design so we don't have to use bleed valve?
@Coreengineers2 жыл бұрын
this double valve is for the extra safety you may say let's suppose if there is a toxic fluid and your valve passes or malfunction so that's why there is a double valve and one bleed valve between them to bleed that toxic fluid