Bosch IDS Ultra Cold Climate Heat Pump-SNEAK PEEK @ahrexpo

  Рет қаралды 4,203

ESCO Institute-HVAC Excellence

ESCO Institute-HVAC Excellence

Күн бұрын

Пікірлер: 19
@chrisripplinger
@chrisripplinger 11 ай бұрын
Please drop the music in the next video. I appreciate the interview, just hard to hear. Thank you.
@TheRickAustin
@TheRickAustin 10 ай бұрын
When will IDS Ultra be available in the US?
@AtanasioHVAC
@AtanasioHVAC 4 ай бұрын
I have installed many of your heat pumps with convential systems and Unico high velocity, why is it when they start up in AC mode they always come on in heat mode, I talked to your tech at Bosch and all they said is that's how they work , when all other brands don't do this, can someone tell me a detailed explanation for this ty Tony
@ziggyd3114
@ziggyd3114 6 ай бұрын
Brüno has an HVAC gig!
@RayRay-nb7tn
@RayRay-nb7tn 11 ай бұрын
If I heard that correctly that the system can operate at a -23* capability, and never shuts off? Does it use electric strips at backup? With today's technology we should be looking at a hp that doesn't use electric strips and use the capability of just the hp to run and heat the home or building. Great info thanks for sharing.
@escogroup
@escogroup 11 ай бұрын
That is correct my friend, no auxiliary heat strips. I do prefer to have redundant heating in case you do have HP failure but it could be a variety of heating sources for backup. I prefer gas backup myself of some sort. CB
@RayRay-nb7tn
@RayRay-nb7tn 11 ай бұрын
Thats great sounds good. Ya I like to have a backup plan too, me gas I would go with but everyone is trying to push for all electric these days to get away from any fuels. Like to see a video of this in action in a complete setup.
@jrsmyth9761
@jrsmyth9761 11 ай бұрын
Imagine your heat loss is 60K, what size outdoor unit do you think will be needed to provide 100% of that 60K at 0°, -7°, -23°? Now how far down will it modulate when you don't need full capacity for heating? You DEFINITELY would not need that capacity in cooling!! Again how far down will it modulate? Finally, how do you produce all this electricity? Do some research and determine the REAL impact of natural gas on the climate.
@twosawyers
@twosawyers 6 ай бұрын
Most of the time you need backup anyway due to defrost mode.
@escogroup
@escogroup 6 ай бұрын
@twosawyers surprisingly these newer units are accomplishing defrost in just a few minutes using smart defrost control. After a little consumer education you can get by without supplemental heating. I myself still size with backup redundancy heating whether electric or gas. Why not
@jrsmyth9761
@jrsmyth9761 11 ай бұрын
5 ton is 60K BTUs and he said 55K. How is it rated, cooling or heating if it is a 5 ton? Yes, my 3 ton has a 30K compressor in it, so marketing comes into play!! 100% efficient at 5°F ambient.
@786otto
@786otto 10 ай бұрын
That PCB board scares me.
@jpenn727
@jpenn727 10 ай бұрын
No music please!!
@bingobingo6410
@bingobingo6410 10 ай бұрын
Now make them mouse proof😂
@fortuner123
@fortuner123 11 ай бұрын
So if I want my house at 25 degrees celsius then what is the cost saving over other heating systems on a day to day basis and on the hardware basis please. Stop your backslapping and give us some hard facts.
@soloch69
@soloch69 11 ай бұрын
Wow, that is amazing. Great video. Great, new information and new product with A2L As I’m sitting here, I am taking the ACCA A2L safety training course today🫡
@RayRay-nb7tn
@RayRay-nb7tn 11 ай бұрын
Good luck this is on my list .
@escogroup
@escogroup 11 ай бұрын
ESCO also offers a complete A2L training course with instructor resources, as well as a playlist of A2L videos: kzbin.info/aero/PL-HeZJqNlYBRlaFrENsGwdJPX1Ap19DIE&si=oX6uFpE_fZNSzzg5 and an A2L FactCheck Blog: a2lfactcheck.blogspot.com/
Bosch 18 SEER Heat Pump 🆚 The Daikin Fit | 2024 Review 🔥
17:59
The HVAC Dope Show
Рет қаралды 15 М.
Cold climate heat pump, the truth in the cold!
5:05
Your Electric Neighbour
Рет қаралды 63 М.
СИНИЙ ИНЕЙ УЖЕ ВЫШЕЛ!❄️
01:01
DO$HIK
Рет қаралды 3,3 МЛН
REAL or FAKE? #beatbox #tiktok
01:03
BeatboxJCOP
Рет қаралды 18 МЛН
Мой ТЕПЛОВОЙ НАСОС : Экономия или миф?
22:56
Ярослав Левашов
Рет қаралды 177 М.
How EPA’s New Refrigerant Rules Are Transforming HVAC Compliance with Keilly Witman
29:45
ESCO Institute-HVAC Excellence
Рет қаралды 38 М.
Are Heat Pump Dryers Really Worth It? Miele Dryer Review
13:11
Undecided with Matt Ferrell
Рет қаралды 790 М.
Does low temperature heating actually use more gas or is that a myth?
10:10
Walk N Talk AHR Expo 2024: Unpacking Midea's Revolutionary Window Heat Pump
10:48
Plumbing & HVAC Magazine
Рет қаралды 18 М.
Hitachi AirH2O MonoBlock Heat Pump
5:36
ESCO Institute-HVAC Excellence
Рет қаралды 838
Why CO2 Heat Pumps Are The Future Of Cooling
14:42
Undecided with Matt Ferrell
Рет қаралды 782 М.
Heat Pumps in 2024 | What You Should Know
20:11
The HVAC Dope Show
Рет қаралды 191 М.
СИНИЙ ИНЕЙ УЖЕ ВЫШЕЛ!❄️
01:01
DO$HIK
Рет қаралды 3,3 МЛН