NEW WZRELB (Reliable) 3000W 48V Split Phase Inverter

  Рет қаралды 11,366

Brad Cagle

Brad Cagle

Күн бұрын

In this video we review the all new WZRELB (Reliable) 3000W 48V High Frequency Split Phase Inverter
Amazon Affiliate Links:
WZRELB 3000W 48V Split Phase: amzn.to/3L3abAs
WZRELB 3000W 24V Split Phase: amzn.to/3AvMImr
I also found these on Ebay for way less than Amazon around $400, so you might search Ebay for them.
================
AFFILIATE DISCLOSURE: This channel may earn an affiliate commission if you purchase products through links I provide.
================
CONTACT: bradcagleyt@gmail.com
Business/Collaboration only. Please do not contact me for for personal project help, or advice.
================
DISCLAIMER: These videos are documenting my own projects, and experiences. These projects, and activities can be dangerous. Do not try any of this at home, doing so will be at your own risk.

Пікірлер: 56
@BeeneEnergy
@BeeneEnergy Жыл бұрын
I like the built in pre-charge resistor. That's slick.
@BradCagle
@BradCagle Жыл бұрын
That is pretty handy!
@BeeneEnergy
@BeeneEnergy Жыл бұрын
My JBD BMS's don't detect under 1 amp of draw very well. I have that Schneider on a battery and it pulling 40w idle is imperceptible in the app so now the battery is dead but shows 160ah remaining, lol.
@BradCagle
@BradCagle Жыл бұрын
Ahh, that makes sense.
@leftofone
@leftofone 2 ай бұрын
I've read transformerless inverters can fail and damage equipment that is connected to them. Is this true? Is this a transformerless inverter?
@Roll2Videos
@Roll2Videos Жыл бұрын
As always great video 👍
@BradCagle
@BradCagle Жыл бұрын
Thanks!
@roosterprice
@roosterprice 7 күн бұрын
Were the neutral and ground bonded?
@gfl1957
@gfl1957 2 ай бұрын
Any update, is it still working?
@RakeshShah-cx7ep
@RakeshShah-cx7ep 3 ай бұрын
@SommerBrindamour-b6z
@SommerBrindamour-b6z 4 күн бұрын
Ruecker Club
@rogue0921
@rogue0921 Жыл бұрын
I believe that's a universal plug for the UK, Australia and may be and RV plug as well.
@BradCagle
@BradCagle Жыл бұрын
Ahh, thanks for the info
@SusanMark-i5t
@SusanMark-i5t 4 күн бұрын
Yost Vista
@KennanEllis-i2h
@KennanEllis-i2h 18 күн бұрын
Langosh Skyway
@budmartin3344
@budmartin3344 Жыл бұрын
2:03 that does not look right, each Hot (Line) terminal of each duplex is joined by that one red wire between the duplex Hot terminals and then the other Red wire goes to the PCB, so each Hot (LIne) of each duplex is not connected to proper L1 and L2. Am I seeing it correctly? If you measure AC Voltage between the Hot terminal of each duplex, do you get 240VAC?
@johnshaw359
@johnshaw359 Жыл бұрын
That 240V socket should be appropriate for the US 240V standard only. WTF.
@BradCagle
@BradCagle Жыл бұрын
I agree.
@kokopelli314
@kokopelli314 10 ай бұрын
I have the 36v 4000w version. The LVC is 37.5. This would be ~equivalent to 46.8 for yours. To me, for LiFePO4 that seems high @ 3.125v per cell.
@jimfields9491
@jimfields9491 5 ай бұрын
So what size breaker/ fuse do you have between your battery and inverter?
@varman001
@varman001 4 ай бұрын
do the math, around 60A
@JiStotsky-j2b
@JiStotsky-j2b 17 күн бұрын
White Court
@WillieGriffin-i2s
@WillieGriffin-i2s 18 күн бұрын
Sallie Village
@TraceyCochell-w5y
@TraceyCochell-w5y 4 күн бұрын
Ruthe Island
@Code_hack_
@Code_hack_ Жыл бұрын
Great video Brad! Have you been using this inverter much lately? Do you know if the 3000w at ~240v is continuous. The provided documentation isn’t clear. Follow up video please!
@WyattQuincy-k7s
@WyattQuincy-k7s 17 күн бұрын
O'Reilly Via
@icarus901
@icarus901 Жыл бұрын
Would one of the enphase inverters initialize if connected to 240v? If so....when there's a balanced load on each leg (or a consistent 240v load like an immersion heating element), does the load shown by the inverter drop by the enphase input?
@BradCagle
@BradCagle Жыл бұрын
Funny you asked this. Chris Beene, and I were just discussing this, and I think we will be experimenting with this.
@tinysparky
@tinysparky 2 ай бұрын
Any luck ​@@BradCagle
@justinmitchuson8992
@justinmitchuson8992 Жыл бұрын
Much better than 150watts idle,
@BradCagle
@BradCagle Жыл бұрын
Totally! 😁
@TomlinsonMay-y2x
@TomlinsonMay-y2x 29 күн бұрын
Olson Ranch
@ElsieRory-p2r
@ElsieRory-p2r Ай бұрын
Emerald Greens
@thedabbler2753
@thedabbler2753 10 ай бұрын
The bit that's making me hesitate on buying this inverter is in the Amazon QA for the device. From the page, "The hardwire terminal can connect to the circuit panel in the house directly to get 120VAC or 240VAC, L1 for live, N for neutral, L2 for live, G for ground. L1+L2=240V, L1+N=120V, L2+N=120V. Note: can not L1+N+L2 at the same time!!!". The first two points seem to make sense, but then the note doesn't. I thought you were supposed to put L1 & L2 into a double pole breaker, land the neutral and ground on the neutral and ground bars, job done, but the note reads like don't do that. Hoping you have some insight, or can hook it to an off grid sub panel or something in another video. What I'm hoping is the 'note' is nonsense and one wires up as I suggested.
@BradCagle
@BradCagle 10 ай бұрын
Hmm, that's a very strange note. So seems to be saying Don't use 240v, and 120v at the same time? I need to revisit this thing. I haven't used it since the video.
@thedabbler2753
@thedabbler2753 10 ай бұрын
@@BradCagle re haven't used, I'm guessing one would forget all about the WZRELB after getting the EG4 6000! Hope that's going good.
@BradCagle
@BradCagle 10 ай бұрын
@@thedabbler2753 It seems to be going good. I really want to get around to doing more videos with it, and installing it somewhere I can put some solid use on it. 😜
@WattsinWattsout
@WattsinWattsout 10 ай бұрын
I just picked up a 24v 4000w model and will be testing for a panel install. Interesting you brought that up in the manual. The Universal 240 outlet has 2 hots @ 120 ea. and the ground is connected to the case ground, terminal and 120v outlet grounds. If you install with a panel the grounds will become neutral bonded and the Universal socket will have 220 and two 120 legs potentially. I have tested a few of these WZRELB 120v inverters and they are running fine with earth ground neutral panel connections as long as you check the 120v outlets that can have polarity issues. .
@thedabbler2753
@thedabbler2753 10 ай бұрын
@@WattsinWattsout as your reply came in I just ordered the 48v 3k model. With a gift card & rewards it was $390. Arrives Saturday. Will be giving it a whirl then.
@SophiaBess-g4b
@SophiaBess-g4b 18 күн бұрын
Schmeler Route
@bruceeverett5372
@bruceeverett5372 Жыл бұрын
What is the use case for this at 240v and only 3000W? I don't think this would handle the in-rush of my well pump or a/c, and all my other 240v household loads are much higher 4500W+.
@BradCagle
@BradCagle Жыл бұрын
I'm not sure yet. I've been meaning to test some 240v loads. Like dryer, pool pump, etc.. I'll get round to it. Thanks
@TechMechRandom
@TechMechRandom Жыл бұрын
I am think it is just for powering a small house/cabin panel that has breakers on both legs 120/120v. I am not running anything in my cabin that requires 240v but need both legs powered for upstairs lighting. I am thinking about getting one of these as the price and power consumption from the EG4 split phase is both kind of high.
@howardwrentworth3359
@howardwrentworth3359 Жыл бұрын
3000w is enough to run a mini split, especially the newer high efficiency models.
@ebenwaterman5858
@ebenwaterman5858 Жыл бұрын
13:50 Cue the X Files theme. I didn't watch this when it came out 'cause I wasn't interested in 220. Am now, kinda'. Thanx anyhow. :)
@BradCagle
@BradCagle Жыл бұрын
Haha, I think that my wife walking by the back door. Or is it 😬
@ebenwaterman5858
@ebenwaterman5858 Жыл бұрын
@@BradCagle :O
@johndesousa7379
@johndesousa7379 6 ай бұрын
can anyone tell me if this is a bidirectional inverter?
@BradCagle
@BradCagle 6 ай бұрын
It's not
@PWoods-cd6tk
@PWoods-cd6tk Жыл бұрын
The anti spark feature is pretty cool. Did you say the neutral and the ground are not bonded together inside? So this could be plugged directly into a manual transfer switch at home?
@BradCagle
@BradCagle Жыл бұрын
I measured no continuity between the neutral and the ground lugs, so it seems it's not internally bonded. I did later measure some AC voltage between the neutral, and ground so I need to figure out if a ground/neutral bond is acceptable on this unit. Because using a generator transfer switch would eventually cause a bond since there is bonding in the panel right?
@PWoods-cd6tk
@PWoods-cd6tk Жыл бұрын
All I know is that you only want one ground neutral bond and that is typically in your main panel. I think this one would work. I see people stick in regular inverters into their transfer switches anyway without any consequences. Thanks for the video I really appreciate it.
@BradCagle
@BradCagle Жыл бұрын
@@PWoods-cd6tk You're welcome 🙂
@kennethnguyen3382
@kennethnguyen3382 9 ай бұрын
I had the 4000w one and the problem with that is when the battery drops down to 48 volts, the inverter shut down and no where that I set it to like 46-40 volts.
@BradCagle
@BradCagle 9 ай бұрын
Bummer, mine I think shuts down between 40-42v
@KennethAnderson-m1y
@KennethAnderson-m1y 13 күн бұрын
263 Janice Rapids
Running My House Off Reliable 3000W Split Phase Inverter
13:24
Going Off Grid
Рет қаралды 4,1 М.
Let's talk about cheap inverters (48 volts)
38:18
HalenTech
Рет қаралды 18 М.
Как мы играем в игры 😂
00:20
МЯТНАЯ ФАНТА
Рет қаралды 3,3 МЛН
А ВЫ ЛЮБИТЕ ШКОЛУ?? #shorts
00:20
Паша Осадчий
Рет қаралды 9 МЛН
Victron + LiTime MINI = beginner friendly off-grid
18:02
Brad Cagle
Рет қаралды 488 М.
Victron Phoenix 1200VA LF Inverter: Extremely Low Standby Consumption and More!
12:13
DIY Solar Power with Will Prowse
Рет қаралды 290 М.
SUNGOLDPOWER 6000W Pure Sine Split-Phase Inverter, Review & Testing
19:07
Why NOT to oversize your inverter!
22:44
Off Grid Basement
Рет қаралды 74 М.
Reliable Brand(WZRELB) 3000W/6000W Surge OFF-GRID Power Inverter Tests!
22:26
Vertical Bifacial Solar Panel Performance Results Part 1
13:05
Projects With Everyday Dave
Рет қаралды 807 М.
Cheap 8000w Reliable Inverter, That Works! WZRELB
16:53
DavidPoz
Рет қаралды 821 М.