Learn Network Cable Management Inside Rack From Scratch

  Рет қаралды 2,339,541

Bro Experts

Bro Experts

Күн бұрын

Пікірлер: 804
@perkowskipiotr
@perkowskipiotr 5 жыл бұрын
Nice looking cabinet. However, I have several suggestions. First, do not use zip ties. Second, you are putting equipment in the cabinet randomly, without taking care of U units. Distances between those square holes are there for a reason. Between each U unit, which consists of 3 square holes, there is narrow interspace. Between holes which are part of certain U unit, there is wider interspace. All pieces of equipment that you have installed has a height of 1U unit, and they have two holes on each side that will fit with top and bottom holes of U unit. If you will not install equipment exactly into U units you will have problems with screws that will not screw. This problem will be even more serious when you will be installing rack servers with rack rails that will not fit because of rails' bolts that will not overlap with rack holes. Later you will have to leave spaces just like in the video, to make things straight again.
@user-nh3gu1ge3d
@user-nh3gu1ge3d 3 жыл бұрын
Def. should use zip ties. If you use Velcro, some lazy asshole WILL undo it "just for a minute" and in a year, it'll look like a rats nest. Only the most outrageous asshole would cut off all those zip ties to add/remote a cable, though. Velcro is just too big a temptation for the lazy.
@enchantingendlers2105
@enchantingendlers2105 3 жыл бұрын
This is an IDF closet. No servers are going in there. Leaving spaces can improve ventilation.
@notsure7874
@notsure7874 3 жыл бұрын
@@user-nh3gu1ge3d you underestimate the outrageous assholishness of people with access to the wiring closet, and their lack of a bag of zip ties. I charge people pretty good money for wire closet cleanups. I hope they have an employee that jacks it all up again - more than happy to come fix it again ... for a price ;)
@andrewshaffer6843
@andrewshaffer6843 3 жыл бұрын
@@enchantingendlers2105 in that case, you should probably leave a 1U space between rackmount devices, instead of 1/3U lol. I don't care how good his cable management is if he doesn't understand rack units.
@hugo122221
@hugo122221 2 жыл бұрын
you watched thisvideos 3 years back to complain? nah u crazy
@even8490
@even8490 Жыл бұрын
Best video I've seen that actually shows how patch panels work in practice. Didn't realise there was that interface at the back that your twisted pairs went into until now.
@taihap123
@taihap123 5 жыл бұрын
I have 2 rules for myself when I do cabling, 1) always use shortest possible cables; and 2) only use velcros, no cable ties.
@irfankarayil8069
@irfankarayil8069 5 жыл бұрын
Yes Velcro is good..
@NetITGeeks
@NetITGeeks 5 жыл бұрын
I think the reason why he used longer patch cables because if you have high-speed internet, the cat6 and cat5e cable shorter than 3 ft often create interference and crosstalk. I have 300 Mbps download speeds. As soon as I plug a cat6 cable shorter than 3 feet, the speed drop to 100 Mbps.
@inamullahansari2792
@inamullahansari2792 4 жыл бұрын
Yes i Agree, Because of if we arrange some additional cable we remove the Velcro and rapping again, Sometimes the cable tie injures our hands,
@servisnetsprint8625
@servisnetsprint8625 4 жыл бұрын
1) yeah, it look nicer, but try to replace a switch without long outage time
@MrLegendL2118
@MrLegendL2118 4 жыл бұрын
Science and Tech so do you just need to make the cables 3’ 3”? I’m new to all this networking stuff and want to build my own.
@alphaprot2518
@alphaprot2518 5 жыл бұрын
Just as a suggestion: do not use zipties. They will likely damage the rubber coat of the cable. Use velcro or something comparable. This also makes it far easier to add/replace/remove cables from the bundle.
@cptcrogge
@cptcrogge 5 жыл бұрын
Agreed, you get cheap velcro (hook-and-loop tape) packs (100 stripes) for like 5 USD.
@cyrylthewolf
@cyrylthewolf 5 жыл бұрын
Zipties on copper - only being tightened down a REASONABLE amount - are just fine and cause no problem. They will not "likely" damage copper cabling as long as they aren't over-tightened. I WILL give you credit on the point that using velcro makes adding and even removing cable easier. There's that. Velcro is preferred these days but let's not get the facts twisted here, either.
@alphaprot2518
@alphaprot2518 5 жыл бұрын
@@cyrylthewolf The facts aren't twisted, because, in order to stay in place at the point you want them, zipties need to be tightened. If you prefer dangling zipties on any place but the place you want them, go for it. Sure, you can put only a necessary amount of force into it, but how many people do this? If your cable management is alright due to the fact, that you carefully put zipties everywhere, that's completely fine (thumps up in this case). But for inexperienced, velcro is just better, e.g. if they need to move the cable trees around.
@cyrylthewolf
@cyrylthewolf 5 жыл бұрын
​@@alphaprot2518 - You said, "do not use zipties". That direction is not justified as zip ties - USED CORRECTLY - are perfectly fine for copper cabling. "zipties need to be tightened" As does velcro... I have no idea what you mean by "dangling zipties" as I don't have that problem. I trip the excess - as is part of the "using it correctly" deal. It's not rocket science. " If your cable management is alright due to the fact, that you carefully put zipties everywhere" Otherwise known as "managing cable". LOL Velcro IS preferable. But there is NOTHING wrong with zipties if used correctly. (Again... Not hard. Doesn't really take 'experience' either. It's a freakin' ziptie.) The point is that you're telling people "do not use zipties" without justification. Say that they're generally preferred - which seems to be accurate these days with so much more fiber hanging about in our data centers/data rooms, sure. But don't discourage it all together. It's still an applicable method.
@TW-fs3fj
@TW-fs3fj 5 жыл бұрын
Ziptie master race does not concur. Ziptie everything so your users are deterred from touching things.
@DrLoveQc
@DrLoveQc 4 жыл бұрын
Good job! 2 suggestions I could make. Use flush cutter instead of scissor to cut zip tye.. otherwise the small sharp plastic left can cut someone badly! Also you should install equipments in theirs respecting U, do not left single hole at top and space by 3 holes if needed. installing another equipment will be much easier!
@kennedyagusina4436
@kennedyagusina4436 4 ай бұрын
very true those small sharp plastics can bring hell to the technician
@BroExperts-Tutorials
@BroExperts-Tutorials 5 жыл бұрын
Thanks for watching the video please consider Subscribing My Channel for more networking videos: bit.ly/BroExperts
@Zer0kbps
@Zer0kbps 5 жыл бұрын
Neat tool, I try to get 0.10m patch cables these days and go PP, Switch, PP and flood patch, I dont like cables down the back or sides of the switches as they more often than not vent their heat in those spaces.
@zadekeys599
@zadekeys599 3 жыл бұрын
Great vid!!! Some tips for efficiency during install & as well as over time for maintenance: 1) Velcro not cable ties (both inside and outside of the cabinet) 1.1) Adding extra cables will take forever unless you make a new bundle over time. 2) The cut-off ends of the zip-tie can be very sharp, and cut you, a co-worker or could damage new cabling installed. More reason to use Velcro. 3) Use a strain relief bar behind the patch panel. This allows an easy to access gap between each cable IDC. As you are currently showing, you will work over the cables & have zero room to easily access 1x cable. 4) Rather do not use a traditional patch panel & instead get a patch panel that takes RJ45 inline couplers. Then you just make a standard RJ45 termination VS a punch down. 5) In such a small rack, space is expensive. Rather use very short cables and only occupy 2U vs 4u. 6) Create the service look behind the vertical rails. If you put a device with more depth in there, you might damage the cables. 7) Install a premade RGB strip & leave it on the company colour(s).
@BroExperts-Tutorials
@BroExperts-Tutorials 3 жыл бұрын
Thanks for giving suggestions ..
@drew5834
@drew5834 2 жыл бұрын
Great to see the constructive criticism, wish they could make their video with all the recommendations they made.
@DavidM2002
@DavidM2002 5 ай бұрын
After 5 years, it is still very instructional as are so many of the comments.
@BroExperts-Tutorials
@BroExperts-Tutorials 4 ай бұрын
Thanks 😊
@josan4613
@josan4613 2 жыл бұрын
best video I have ever seen, quick and very neat!
@tavarescarlos2
@tavarescarlos2 5 жыл бұрын
Nice work! I would have installed the cabinet so it would cover the hole in the wall, where the cables come out.
@LinwoodPowell
@LinwoodPowell 5 жыл бұрын
Those NavePoint cabinets do not have a cable inlet in back, only bottom. They should have use some conduit.
@tavarescarlos2
@tavarescarlos2 5 жыл бұрын
@@LinwoodPowell The cabinet back can always be perforated! But yeah, conduit would be an alternative. I just think a nice cabinet with real neat wire management loses purpose when you have wires coming up from an ugly hole in the wall!
@Lewdacris916
@Lewdacris916 3 жыл бұрын
I think the rack would of been too low if he mounted it over the hole where the cables are coming out, but yeah that would be more appealing astetically
@user-cx4ev9fw1k
@user-cx4ev9fw1k 7 ай бұрын
that looks pretty darn good....NICE!
@oluwasegunbamidele2885
@oluwasegunbamidele2885 3 жыл бұрын
i enjoyed this video, it shows ur professionalism
@BroExperts-Tutorials
@BroExperts-Tutorials 3 жыл бұрын
Thanks .. pls subscribe for more stuff like that ..
@GerbenWijnja
@GerbenWijnja 2 жыл бұрын
Such a cable bundle organizer is better known as a "cable comb". Really nice job though! The only remark I have is about the zipties/tiewraps. Cut them off flush, it looks little bit neater. (with a cutting tool, not with scissors)
@BroExperts-Tutorials
@BroExperts-Tutorials 2 жыл бұрын
I have used velcro in my new project video kzbin.info/www/bejne/nIbEhaeDZdiAfck
@ltdees2362
@ltdees2362 4 жыл бұрын
👍 I enjoyed watching, you do excellent work! Only thing I do different...I do not punch-down my cables, I install RJ45 plugs on the cabling and use a keystone bracket & pass-through jacks. Makes trouble shooting much easier...I use bigger cabinets as I install a rackmount UPS along with a rackmount surge protected power strip 😎
@rizwanpathan6512
@rizwanpathan6512 3 жыл бұрын
hey yesterday i have lots of confusion about patch pannel but after watching your video i am 100% clear what exactly patch pannel is i have subscribe to your channel also thanks a lot
@BroExperts-Tutorials
@BroExperts-Tutorials 3 жыл бұрын
Glad I could help, Thanks for the subscribe :)
@akhildev7558
@akhildev7558 2 жыл бұрын
Great video. Cam someone help me with estimation? I want to as to how many rolls of cables, patch panels are required in a specific project? Any videos on these?
@sergeyzelyukin267
@sergeyzelyukin267 5 жыл бұрын
I hate cabling without labeling, even if it seems too excessive now, it will definitely help the next engineer to replace the failed switch
@dennycrane2938
@dennycrane2938 5 жыл бұрын
Isn't that the point of the patch panel? Label that?
@khantoseef6001
@khantoseef6001 5 жыл бұрын
You are right bro
@enesaslan3275
@enesaslan3275 4 жыл бұрын
Patch Port 1 ---TO---> Switch Port 1 Patch Port 2 ---TO---> Switch Port 2 Patch Port 3 ---TO---> Switch Port 3 . . . . Patch Port 22 ---TO---> Switch Port 22 Patch Port 23 ---TO---> Switch Port 23 Patch Port 24 ---TO---> Switch Port 24 where is the fault?
@michaelcostello6991
@michaelcostello6991 2 жыл бұрын
Very clear demonstration. Thanks
@BroExperts-Tutorials
@BroExperts-Tutorials 2 жыл бұрын
Thanks
@michaelkael5192
@michaelkael5192 5 жыл бұрын
I like your video and your installation, but I would do it a bit other way: 1. USE VELCRO STRIPS INSTEAD OF ZIP TIES. I wrote this with Caps Lock on because you overtightened these ties, deforming and damaging the cables. I've seen way too many "it sometimes work and sometimes not" network troubles caused by this. Zip ties are awesome, but not when used like this. You'll also find out velcro (or similar) strips are reusable, so it's easier to keep it nice and clean over time with adding/replacing/removing cables and everything. I am well aware many people here wrote this already, please see their comments as well. 2. Install the cabinet so that the tube coming through the wall ends in the cabinet, not below it. This makes it cleaner (less dust in the cabinet) and nicer to look at. I also find it more comfortable to work with. Other people already mentioned this. 3. These patchcords are going wild in the back, possibly affecting the cooling of the switch. I usually route them in a conduit on the side, so they aren't getting in switch's airflow. 4. I heavily prefer modular patch panels with individual keystones. It is a bit more expensive, but I found it better in certified Cat6 and above installations. 5. Include a plan, legend or some other aid to know which cable is which. I usually put it on inside side of cabinet's door. I also always use racks with full metal doors, not glass ones. 6. Some color coding, maybe? If this only connects 24 computers or Wi-Fi APs together to some fiber or other uplink, having all the patchcords the same color is okay. If not, using for example green for LAN, blue for SAN and so is a good practice - don't forget to document this in the aforementioned plans/schematics on the front door. Somebody else already wrote this, and I add - if there is more than one cabinet in the building/campus, use the same color-code everywhere. 7. Ensure proper cooling of switches, router and/or other devices in the cabinet. There should be good airflow, unobstructed by wild cables (this reminds me, how did you store spare length of incoming cables?) or other stuff withing the cabinet. 8. Use air filters to make sure the cabinet isn't collecting all the dust in the room, even if it is a dedicated server room or something. TL;DR: You have done well. It isn't perfect, but I'd still recommend you to a relative - just please use velcro strips instead of zip ties, or at least don't tighten them this much.
@JohnSmith-fz1ih
@JohnSmith-fz1ih 5 жыл бұрын
Spot on on all counts. Personally I'd add that while this looks very organised, it's actually pretty difficult to work with and to trace cables. I prefer to forego the plastic cable management strips and instead mount the switch directly under the patch panel, then use 25 or 30cm patch leads straight into the switch. (Which is admittedly more difficult with a switch like the one in this video where all the ports are on the right-hand side). This works beautifully with 48-port switches and 24-port patch panels. Install a patch panel top, then use short patch leads to go to the 24 top ports on the switch. Then install a patch panel below and use short patch leads to the 24 bottom ports on the switch. This is neater, it makes it trivially easy to trace cables, it doesn't leave a big bundle of patch leads messily at the back, it takes up less vertical space (so you have room for a small UPS or other gear), and adding, tracing, or moving a patch lead doesn't require access behind the switch and panels so you don't rick knocking out other cables by accident.
@Jirk4
@Jirk4 5 жыл бұрын
I am surprised zip ties are so heavily frowned upon in the comments section, I am using them all the time and never had any issues. Last time I used A LOT of zipties (hundreds), I ran three POE IP cameras, about 50 meters each line, for 80% of the length ran together through attic and I ziptied the (3) cables together to nails along the way so they stay in place and won't get damaged when moving stuff in and out of the attic. What should I do instead?
@JohnSmith-fz1ih
@JohnSmith-fz1ih 5 жыл бұрын
@@Jirk4 The main problem is the way they were overtightened in this video. If they were left open a bit more to hold the bundle of cables together but not so tight to put pressure on the cables it would have been fine. The minor problem with zip ties is they can't be re-used like velcro ones, so if you add a couple more cables they either don't end up bundled in or you have to cut each one and use a new set of zip ties. (And if you choose to cut and the original was too tight, showing the scissors in there to cut the original makes the original tie even tighter).
@michaelkael5192
@michaelkael5192 5 жыл бұрын
@@Jirk4 I also use zip ties all the time and they are awesome, but some people tighten them too much, damaging the cables. Most people would just tighten them as much as they can as if they were testing their strength or something.
@tonystarch4487
@tonystarch4487 5 жыл бұрын
@@Jirk4 : never had any problem either, used almost billions of zipties over the years. And lately always certified the work with a Fluke CableAnalyzer, sometimes many years after initial installation; without any problem.
@plagapong
@plagapong 2 жыл бұрын
This cable management somewhat satisfied my OCD :p
@mannyteixeira2660
@mannyteixeira2660 Жыл бұрын
Well organized cable. Nice work.
@BroExperts-Tutorials
@BroExperts-Tutorials Жыл бұрын
Thank you! Cheers!
@arpandeshmukh
@arpandeshmukh 5 жыл бұрын
Very clean & nice work done !! Appreciate taking time to make the video and spreading knowledge. Good work !!
@jerrymiller8313
@jerrymiller8313 5 жыл бұрын
Use a modular patch panel with a lacing bar make troublshooting easier. use printed labels. Velcro. Test all cables
@RobskiKD
@RobskiKD 5 жыл бұрын
Absolutely I cringe when ever I see this. Cable ties are a no no, the other thing never trim cable ties and leave tabs like that they are down right dangerous to any one reaching into the cabinet trust me. In fact some industries don't allow there use period. Hook and eye raps are the go, besides a cable tied bundle may/will fail qualification and or certification seen it before. As for the eye and hook aka velcro you can also buy it in rolls real handy. Great effort just need to lift the game a bit and yes label the cables it happens "someone" moves a cable for testing and it never goes back in the correct slot makes trouble shooting way easier especially years on. :) and do test even the patch leads not unusual to get out of the "bag" failures just saying.
@juanmamani2110
@juanmamani2110 Жыл бұрын
Great video even the good suggestions! Thanks for sharing
@BroExperts-Tutorials
@BroExperts-Tutorials Жыл бұрын
Thanks
@curieux8
@curieux8 3 жыл бұрын
1. Cables must be as short as possible 2. Cables must not be exposed outside the wall rack. They should be putted inside a trunk. 3. Patch panel must be labeled with correspondent outlets 4. Patch cords must be connected in an easier way (think about troubleshooting and replacing). Shorter patch cords can be used (0.5 m) with with only 1 CMU.
@BroExperts-Tutorials
@BroExperts-Tutorials 3 жыл бұрын
Thanks for your suggestions (: .. here is my new project video kzbin.info/www/bejne/nIbEhaeDZdiAfck
@ColaCal
@ColaCal 2 жыл бұрын
I always wondered how to make cable tie burs so that the next technician gets scratched and cut. Thanks
@mazen110110
@mazen110110 3 жыл бұрын
The second cable punched in a wrong way - you should put brown wire first then white and brown..., using velcro is better than ties..., if you want to use ties you need to cut it all, don't leave a small piece it works as a knife latter when you work inside the rack...
@beymarfernandohuchaniquisb5651
@beymarfernandohuchaniquisb5651 2 жыл бұрын
well explained. Thank you so much.
@ram64man
@ram64man 5 жыл бұрын
This approach won’t work on large installations, this method is mainly for small installations or home networks where the switch has the same amount of keystones available and order isn’t important When cabling large organisations only x switches may be available and rooms are blanket cabled, or budget restraints, leaving many of them redundant, it’s important split each room down into port, room , floor and even riser number, and wire in sequence this will aid when equipment, iP phones , wan access points , door access points , fire sensor equipment or ip cctv are added , only Velcro tied in 10 cables at a time and label , as cables can be damaged in building work this easier replacement, also in some organisations they insist on two switch setup above or below each keystone bank to separate vlans for Poe or public access points , the exact details should be discussed in network planning with the client
@arvinbriones4032
@arvinbriones4032 Жыл бұрын
great video sir, can i ask question patch panel are use to connect a lan thru walls for example? im a right sir???
@BroExperts-Tutorials
@BroExperts-Tutorials Жыл бұрын
Yes correct..
@enchantingendlers2105
@enchantingendlers2105 3 жыл бұрын
Nice work. Use a side cutter to cut the cable ties flush to prevent any injuries.
@almatec.info661
@almatec.info661 7 ай бұрын
Tks for this video! (Obrigado pelo vídeo)
@BroExperts-Tutorials
@BroExperts-Tutorials 6 ай бұрын
Welcome :)
@chanchanvideo9318
@chanchanvideo9318 Жыл бұрын
Great thank you for this video tutorial bro
@dr.imranbhatgenderselectio8813
@dr.imranbhatgenderselectio8813 Жыл бұрын
Excellent work
@macrapidito1
@macrapidito1 5 жыл бұрын
Great work, I have seen lots of videos about racks and cable management, this is the one to follow 👌🏻👌🏻💪🏻😎
@RiseUpBeforeU
@RiseUpBeforeU 5 жыл бұрын
Nice cable work management guide overall but, you made a few crucial mistakes. First you need to use Velcro wraps instead of those plastic zip ties. Next you are supposed to have a Rigid Plastic Insulated Bushing attached to the end of that "chase" pipe that's coming out of the wall, that your cables are coming out of. It protects the wires and prevents damage to the wire insulation and is flame retardant material to 105C. You also must install a "ground" wire to your data rack. After you're finished with everything, it would be a good idea to use "Fire Stop" putty to cover up the hole you made in the wall for your data cables, in case of a fire. The big mistake you made is on port #2 of your patch panel. First off, look at video marker 4:33 just before you were getting ready to punch down (terminate) those cables. You accidentally put the brown pair in the wrong slot.. it's reversed. On port #1, you have white blue...blue white; white green...green white; white orange...orange white; white brown...brown white, which is correct for T568A. But on port #2, you have white blue...blue white; white green...green white; white orange...orange white; Then you reversed the brown pair. It should be white brown...brown white. Instead of brown white...white brown. Also try next time to keep the cable jacket closer to the patch panel while you're adding each twisted pair to their pins. Your cable jacket should be in the center of each block between pairs 2&3. It will then look like the pairs are fanned out. I see you are using the old method of T568A when everyone these days is using the industry standard of T568B. For the other viewers, T568A is only used in some older hospitals/medical centers and for Nurse Call devices and in some older schools. I hope you tested all the cabling and Jack's before you signed off on your patch panel job. And lastly, you shouldn't have had your patch cords buried in the back of that rack. They are supposed to be in the front. I'm surprised nobody else caught this in the comments section about that reversed pair on port #2. Sorry. Didn't mean to nit pick everything on your mistakes but, that's the way these installations are done these days. Oh well, nice tutorial anyways. Thanks for sharing.
@solomonkinuva9573
@solomonkinuva9573 2 жыл бұрын
u would have made a very good hair saloonist very neat cabling bravo
@admiralgeneralaladeen2949
@admiralgeneralaladeen2949 4 жыл бұрын
So Far, You are the only guy I saw who used that little green organizer you used before you tie those cables 😂
@admiralgeneralaladeen2949
@admiralgeneralaladeen2949 4 жыл бұрын
I have a question. I'm designing for an Office Network and I'm new with this. What materials should I use from the PC to the Server? -RJ45 Connectors -UTP Cat 5 -Patch Panels -Switch -Router -Wireway And, I don't know how to decide for my Rack.
@jaycie5021
@jaycie5021 4 жыл бұрын
@@admiralgeneralaladeen2949 Probably too late now but you want to future proof. For the cabling you want minimum cat 6A shielded cable or if you can swing the extra couple bucks cat 7. For runs in the wall you want solid core cable for patch cables stranded cable is better. The patch panel and RJ45 connectors getting grounded ones makes the shielding actually work. Make sure every component says the cable standard you settled on before implementing it. With the patch panel there are 2 big groups. Ones that take keystone jacks and ones that you wire directly. The one that accept keystone jacks will be cheaper but remember to factor in the jacks. That said it can be simpler then trying to work on one long bar to individually terminate every cable. With the switch and router just look at their quality. It's not worth saving $50 on a fly by night brand if you won't get the reliability. Router Downtime and replacement can eat any savings in not going with one of the big boys. My old company didn't do this and a 30 minute outage literally meant thousands of dollars flying away.
@krunalnv5858
@krunalnv5858 4 ай бұрын
Thank you brother.
@vicv9503
@vicv9503 5 жыл бұрын
Great job man! but i guess if you want to 'teach' good practices just 2 tips.. 1.use hook and loop velcro, it is wider in general and wont pinch the cable, this wont attenuate the UTP signal. 2nd is buy a label printer, your approach might be easy on the eyes(that counts a lot), but could be a nightmare for other techs to figure out which one is which.
@ebrahimhassan239
@ebrahimhassan239 Жыл бұрын
Very great video.❤
@AnyMedia
@AnyMedia 5 жыл бұрын
Zip ties should never be used in network cable management... only when it's temporary... Use velcro/hook n loop etc... This dude overtightened zip ties, that's way to damage network cables.
@jessesanchez5294
@jessesanchez5294 5 жыл бұрын
I've used zip ties never caused damage....
@MyReviews_karkan
@MyReviews_karkan 5 жыл бұрын
Zip ties never cause damage to network cables, unless you're fiber optics.
@someguy4915
@someguy4915 5 жыл бұрын
@@MyReviews_karkan They do, they're not likely to cause damage if you do 100Mb or cause noticable damage if you do 1Gb short distance (
@extortioner3173
@extortioner3173 5 жыл бұрын
@@someguy4915 10Gb copper cables with sfp+\xfp connectors on each side are pretty hard to damage with zip ties
@lelandclayton5462
@lelandclayton5462 5 жыл бұрын
@@someguy4915 using Copper for 10Gb is a beginners mistake anyway.
@cesaraugusto3554
@cesaraugusto3554 5 жыл бұрын
Hello, thank you very much for your idea to organize the rack, I am starting this business, greetings from Colombia
@BroExperts-Tutorials
@BroExperts-Tutorials 5 жыл бұрын
Best of luck 👍
@andreayoung795
@andreayoung795 2 жыл бұрын
Great work 😊
@PaulCherepnin
@PaulCherepnin 5 жыл бұрын
forgot to label all cables coming from the wall as well as all patch cords inside the cabinet
@m_a_s6069
@m_a_s6069 4 жыл бұрын
Didn't even keep it consistent. For the most part he just plugged cables wherever.
@Mosesmkjr
@Mosesmkjr 3 жыл бұрын
Very nice thank you very much for this video its been very helpful to me indeed.
@hanzshcaerp5723
@hanzshcaerp5723 3 жыл бұрын
The cable manager link goes to a different cable manager than you are using in the video. Can we get the correct link?
@allenmaphosa3446
@allenmaphosa3446 5 жыл бұрын
Great video, very detailed and yet not boring. i like velcro though compared to cable ties.
@herrmutz
@herrmutz 5 жыл бұрын
First, no cable ties, use velcro as mentioned in other comments, second : if you are persistant and use them anyway cut those damn things flush, the next person working on the cables will get cut on the sharp edges, also your cables will get destroyed.
@valentinhristev174
@valentinhristev174 5 жыл бұрын
Good old days when i was building racks (:
@krishnakhatiwada5371
@krishnakhatiwada5371 4 жыл бұрын
Hello sir I am from Nepal I need cable organizer do you hav
@Bleachiiigo
@Bleachiiigo 4 жыл бұрын
Do you work at layer 3 now?
@palkatawde9071
@palkatawde9071 5 жыл бұрын
When you split a cable to terminate on patch panel you should keep the wires slightly up not pointing down on the video you are trying to terminate and get wires cut and you have to crimp 4 to 5 times before the wires get cut if you leave the wires pointing up when you terminate the wires it will be cut 1st time and not make the gaps on patch panels big
@alexandroskolkov2231
@alexandroskolkov2231 3 жыл бұрын
euqipment not aligment by units. one unit is free, one unit is lost. with short cables you can manage this rack without rigth/left side opened. two man mounting half size rack switch - awesome.
@futureofhuawei
@futureofhuawei Жыл бұрын
good job . thank you boss 🌹
@BroExperts-Tutorials
@BroExperts-Tutorials Жыл бұрын
Welcome 🙏
@lucastabosa8855
@lucastabosa8855 2 жыл бұрын
I love you Indian IT, i love u 🙏🏻
@BroExperts-Tutorials
@BroExperts-Tutorials 2 жыл бұрын
Thanks but this channel is not from India
@ciclistisalvarosa3047
@ciclistisalvarosa3047 4 жыл бұрын
Good work where from you buy Ethernet Network Patch ???? Thanks
@BroExperts-Tutorials
@BroExperts-Tutorials 4 жыл бұрын
Pls check video description..
@mikey510
@mikey510 3 жыл бұрын
looks clean. thanks for the video
@lalolg5726
@lalolg5726 5 жыл бұрын
Muchas gracias, muy didáctico!!! Thanks for sharing your knowledge!!
@alenc8219
@alenc8219 2 жыл бұрын
Good job!
@fernandotalavera712
@fernandotalavera712 2 жыл бұрын
Thanks, good job.
@MarceloGraciolli
@MarceloGraciolli 8 ай бұрын
Could you please provide the size of the cable you're using from the patch panel to the switch? Thanks
@BroExperts-Tutorials
@BroExperts-Tutorials 8 ай бұрын
Pls check the video description
@MarceloGraciolli
@MarceloGraciolli 8 ай бұрын
@@BroExperts-Tutorials Yes, I checked but no information about that. Thanks for nothing!
@mapagmw
@mapagmw 7 ай бұрын
And what cat. was the patchcords?
@carpii
@carpii 5 жыл бұрын
on this cabinet, can you rack mount things to the back rails too (if there was space), or only the front?
@papachris8540
@papachris8540 4 жыл бұрын
Im sorry if this is an ignorant question. Is this a career choice or job? Sorry just new to this field
@richardrhule6774
@richardrhule6774 5 жыл бұрын
SWEET AND PROFESSIONAL WORK...I LOVE IT KEEP IT UP.
@kalijasin
@kalijasin 3 жыл бұрын
Your work is so many clean 😁
@whatsthishit
@whatsthishit 7 ай бұрын
good luck adding to this setup
@Deraco1
@Deraco1 4 жыл бұрын
Nice video but noticed that you didn't use the U unit spaces as intended in the rack. Each U space has three square holes represented vertically. The two square holes closest to each other are the division points between each Unit.
@normanandrade7427
@normanandrade7427 2 жыл бұрын
Just a question... no space for nobreak or energy?? how many Units is that Rack?? 6U?? thank you,
@BroExperts-Tutorials
@BroExperts-Tutorials 2 жыл бұрын
Thanks for your comment.. yes it's 6U rack.. you can check video description I have given links of each item..
@saxnable
@saxnable 2 жыл бұрын
Cable management: A+ Timelapsing: D
@ikkuranus
@ikkuranus 5 жыл бұрын
Might as well have gone with velcro instead of zip ties. Is it possible to use a single 1u organizer and still get decent results? I figure if you need to waste 2 rack units might as well just have a patch panel on both sides of the switch and use short cables.
@sitte24
@sitte24 5 жыл бұрын
Of course 1U will be enough, it just comes down to the point of having cables with the right length. Too much slack could fill up the organizer quickly
@davemarriott7940
@davemarriott7940 5 жыл бұрын
Yeah it is. No need for the length of the patch cables. Could have got away with a single management panel. If that switch ever gets replaced with something slightly deeper you gonna have to re do all the cabling at the front.
@melucca
@melucca 4 жыл бұрын
suggestion: do not use zipties. They probably damage the cable, zipties (hangs cat) compromise the damaged cable compromises on the network certification. Use Velcro
@alexanderboberg2123
@alexanderboberg2123 2 жыл бұрын
Hi ☺️ Nice work! I liked the cabelguides! Made it look tidy 👍 what brand is that?
@BroExperts-Tutorials
@BroExperts-Tutorials 2 жыл бұрын
Thanks for your comments.. pls check video description all links are available there.. thanks 😊
@JunPVlog
@JunPVlog 3 жыл бұрын
Thank you for sharing sir new supporters here
@alexting8868
@alexting8868 4 жыл бұрын
Sorry i'm new here. why the cat cables don't direct connect to switch panel? what is the benefit connect the cables to converter and then another cables go to the switch? please advise thanks.
@eraser0artem
@eraser0artem 5 жыл бұрын
I think those 2 big holes in cable manager, aren't meant to have cable passed through them. Always thought, cables should come out from side of it. With this type of mount, i see several issues: 1. Cables covers switch vents on a back, it can lead to overheat. 2. If you will want change positions, or add hardware to rack, you'll have to unmount the whole thing. If patch cables came out from side, then you'll be able to move any element, even if switch is on.
@nurspass
@nurspass 5 жыл бұрын
Agree
@isrararain
@isrararain 11 ай бұрын
Great Video for info
@memem1792
@memem1792 2 жыл бұрын
i want to see the cabel managemnt of the interieur of the rack also is not good to zip .if you install a bigger switch or router how do you do it with all the cabels in the back .i want to see a video with this .Please
@BroExperts-Tutorials
@BroExperts-Tutorials 2 жыл бұрын
Please check my new project video kzbin.info/www/bejne/nIbEhaeDZdiAfck
@Manuel-1337
@Manuel-1337 5 жыл бұрын
Great video. Next time use Velcro ties and maybe one cable manager, or no manager at all by just getting some short 1-2ft patch cables. 4U for 24 cables sounds like an over kill
@codbudgie
@codbudgie 5 жыл бұрын
depends how many endpoints they are looking to switch, a 24 port switch is pretty damn small tbh
@yoni07informatico46
@yoni07informatico46 6 ай бұрын
Excelentes video gracias!!
@techprosolution23
@techprosolution23 3 жыл бұрын
ekdam mast
@nickl8830
@nickl8830 5 жыл бұрын
thanks for sharing this video - that was cool to watch and gave me some great ideas
@MatteoLacava
@MatteoLacava 5 жыл бұрын
Thank you, Nice video Now i have a general idea how to do
@teddywinters9296
@teddywinters9296 3 жыл бұрын
You can directly plug it right? Why two panels?
@P0pobkin0MAN
@P0pobkin0MAN 5 жыл бұрын
Wrong termination of twisted pair cable on IDC detected. The length of nontwisted wires could not be more than 1/2 inch. You make much more. It will take nagative effect to NEXT and bandwidth of channel
@P0pobkin0MAN
@P0pobkin0MAN 5 жыл бұрын
Excuse me for my terrible English
@robson2650
@robson2650 5 жыл бұрын
You're right / ты прав / masz rację
@nurspass
@nurspass 5 жыл бұрын
Agree
@johnnardini6140
@johnnardini6140 5 жыл бұрын
You beat me to this comment! As others have said already, he should have used velcro and not cable ties, as they were overtightened, which would damage the cables over time
@sotmrus
@sotmrus 5 жыл бұрын
А если по-русски то, что он сделал не так с проводами?
@JosephTammaro
@JosephTammaro 3 жыл бұрын
Question: I am installing CAT6 to use for IP cameras. About 20 IP cameras. Do I organize them the same way?
@onesteptonetworkengineer
@onesteptonetworkengineer 2 ай бұрын
Today I got the idea that what's the actual use of patch panel👍🏻 And noticed that patch panel port number should be equal to switch port number 😅
@andyfamily9852
@andyfamily9852 5 жыл бұрын
Very nice, can you tell me how many devices this network cabinet has and the cost details for each of these devices? I am also researching and building a network like you for my rental building. Thank
@BroExperts-Tutorials
@BroExperts-Tutorials 5 жыл бұрын
Thanks for your comment.. This network also was built for building.. In 4 floor building i made cabinet in two places 4rth floor and 2nd floor to cover all the rooms.. Each room we fixed indoor wireless device.. 24 port d link poe switch was around $222. I used 4ipnet wireless access points each access point cost me $83.. Items list u will see in the description of this Video... Anything else u want to know?
@mduduemmanuel4585
@mduduemmanuel4585 4 жыл бұрын
@@BroExperts-Tutorials nothing else 😄
@luiznetobrigido6854
@luiznetobrigido6854 5 жыл бұрын
Ficou só o ouro!!! Muito bom!!!
@lincolnkarim1
@lincolnkarim1 11 ай бұрын
Just to let you know that for more than a decade now (it's 2023), there has been a concerted effort in the Networking and Broadcasting industry to avoid using nylon cable ties.
@hashimsontech7090
@hashimsontech7090 4 жыл бұрын
Nice video for beginner
@dr.imranbhatgenderselectio8813
@dr.imranbhatgenderselectio8813 Жыл бұрын
Masha Allah
@iCdaniel
@iCdaniel 5 жыл бұрын
Muchos expertos corrigiendo al amigo que hizo el video. Háganlo ustedes y comparta su sabiduría!!! Too many experts correcting the friend who made the video. Do it by yourselves and share your wisdom!!
@pavellopezbonifacio9885
@pavellopezbonifacio9885 5 жыл бұрын
Bien dicho
@rashidkhanbalochrishibaloc6879
@rashidkhanbalochrishibaloc6879 3 жыл бұрын
Good working
@hanifabaali3299
@hanifabaali3299 3 жыл бұрын
Excellent job. Excuse me sir. How can i get a cable bandal for eliminating cable
@189wow
@189wow Жыл бұрын
Nice video 🎉
@AntonioSalazar-db1eb
@AntonioSalazar-db1eb 2 жыл бұрын
good job!
@BroExperts-Tutorials
@BroExperts-Tutorials 2 жыл бұрын
Thanks
@scoutfai
@scoutfai Жыл бұрын
I do not understand why we cannot directly plug the ethernet cables coming out from the walls directly to the PoE switch. What is the reason to have an intermediate device in between the ethernet cables coming out from wall and PoE switch?
@BroExperts-Tutorials
@BroExperts-Tutorials Жыл бұрын
Patch panel is very useful when it comes to management.. you can easily manage cables and also in case if extension you have flexibility to extend cable by using longer patch cords without cutting or punching connector again. Hope it's clear..
@pbpunisher99
@pbpunisher99 2 жыл бұрын
Not to be critical, but I would use velcro not zip ties. Also, I would use jacks, not punchdown panels. Last. I just use 1ft patch cables and save the 2u of space.
@BroExperts-Tutorials
@BroExperts-Tutorials 2 жыл бұрын
Thanks for your comments.. all these suggestions I have used in my new project pls watch my new video here kzbin.info/www/bejne/nIbEhaeDZdiAfck
@MrJohnziggy
@MrJohnziggy 4 жыл бұрын
Nice job. But just wants to know the name of the cable holder. the green thing. How do I get one.
@BroExperts-Tutorials
@BroExperts-Tutorials 4 жыл бұрын
Pls check video description.. Link is there..
Learn Network Cable Management for Home Racks
8:10
TCI Productions
Рет қаралды 452 М.
On câble ma baie informatique ensemble !
17:21
Tech2Tech - Mikaël
Рет қаралды 798 М.
My Daughter's Dumplings Are Filled With Coins #funny #cute #comedy
00:18
Funny daughter's daily life
Рет қаралды 32 МЛН
Help Me Celebrate! 😍🙏
00:35
Alan Chikin Chow
Рет қаралды 86 МЛН
Good teacher wows kids with practical examples #shorts
00:32
I migliori trucchetti di Fabiosa
Рет қаралды 13 МЛН
DIY Home Network: Experts Debate - Right or Wrong Techniques?
10:11
Torogi Pro
Рет қаралды 1,4 МЛН
What is a Patch Panel?  (cable management)
6:43
PowerCert Animated Videos
Рет қаралды 296 М.
Wiring up a small office network rack (moving 10)
13:48
Jeff Geerling
Рет қаралды 298 М.
Install Network Rack 18U 42 Connection cable
8:46
Crafts & Hack life
Рет қаралды 16 М.
How to Terminate on a Patch Panel
15:47
Delmi Training Institute
Рет қаралды 292 М.
A DAY in the LIFE of the DATA CENTRE | FULL CUSTOMER "RACK & STACK" with ASH & JAMES!
12:28
My Daughter's Dumplings Are Filled With Coins #funny #cute #comedy
00:18
Funny daughter's daily life
Рет қаралды 32 МЛН