Butchered Fuseboard 🤦🏿‍♂️AND No Main Earth For 40 Years!!! | Fault Find and Repair

  Рет қаралды 80,980

Eastway Electrical

Eastway Electrical

Күн бұрын

This video is made in association with Ads + Brand. Facebook Ads Agency for small business:
Contact Ads + Brand for a consultation: www.adsandbrand.com
Please also follow me on Instagram:
/ delroythespark
We will soon be launching a Facebook Group for all electrical enthusiasts to interact and share information. To be notified when this launches please join the Delroy The Spark Mailing List:
eepurl.com/hdRPXD

Пікірлер: 219
@edinburghambler
@edinburghambler 3 жыл бұрын
I'm not an electrician or needing electrical work and no idea how i ended up on this video but I've just watched the whole thing with great interest. Subbed lol 👍✊
@eastwayelectrical
@eastwayelectrical 3 жыл бұрын
Welcome to electrician KZbin
@robinmyman
@robinmyman 3 жыл бұрын
My last neighbour called me around after they had a kitchen refit. MCB would not turn on for kitchen ring. All sockets in kitchen were dripping wet after tiling. So I pulled them all out to dry out. Next day when they were tidy and dry I put the sockets back in. MCB happy again. Noticed new mini strip lighting under wall units...wondered where they were powered...no plugs. Bell wire from the back of the cooker. Neighbour said leave it...they were professional kitchen fitters...they must know what they are doing. Absolutely flabbergasted.
@bigt6889
@bigt6889 3 жыл бұрын
That wouldn't surprise me at all... ive been sent to sort out many a " professional kitchen fitters " work. Joiners should stick to working with wood lol
@Mainly_Electrical
@Mainly_Electrical 11 ай бұрын
They don't know what there doing
@Lesboss1968
@Lesboss1968 3 жыл бұрын
I used to be a cable jointer, to fit an earth wire to the cable, the best way is to strip back both steel tape armours, clean off the bituminous impregnated paper off the lead sheath. You then tie the earth wire to the sheath and using a blow torch and D metal you plumb the earth wire to the lead sheath and the other end goes into an earth block. Another method was to change the iron clad cut out for a new plastic modern one and the earth wire then went into the earth block connector on the new cut out. We used to strip these cables live by cutting off the lead sheath and then getting to the cores that were only covered in paper tape.
@starman_uk
@starman_uk 17 сағат бұрын
Sadly we don't solder any more but respect for the old lost to time skills but we use a tension force spring and copper braid to provide a suitable earth on an old PILC based service
@kennethausten
@kennethausten 6 ай бұрын
Last extension i was called out to was wired in twin bell wire. Several two gang 13a sockets. Then found connected to the lighting circuit. I just powered down and advised the owner to contact the builder who installed it. No earth obviously.
@michaelnapier292
@michaelnapier292 3 жыл бұрын
The gods were shining on you that day del. I certainly wouldn't be hacking away at a pilc cable. Should have put in a temp earth electrode. Well done on sorting the customer out.
@farooqshah2797
@farooqshah2797 3 жыл бұрын
balls of Steel !!
@Tammas
@Tammas 3 жыл бұрын
There was no danger mate - he only removed the hessian. Under that it's 2 layers of steel tape armour and you won't get through that with a knife.
@trespire
@trespire 2 жыл бұрын
Wow. That violation is as seriouse as they come. Diagnostic is half the solution, well done Del !!
@donwright3427
@donwright3427 3 жыл бұрын
Still safer than installations i seen in some Asian countries .Thank God we got guys like you to keep us safe
@pistolpete5189
@pistolpete5189 3 жыл бұрын
Del your braver than me I would have ran for the hills with that one 😂
@caliden
@caliden 3 жыл бұрын
I think it's because the lady seemed nice and had him back within a few days so there was no messing him about with price.
@marlonblade007
@marlonblade007 3 жыл бұрын
Even I know no earth is bad
@barrydoherty636
@barrydoherty636 3 жыл бұрын
Well done Del, you've got a nice way about you.
@Elvis_TheKing
@Elvis_TheKing 3 жыл бұрын
Well done Del, glad you managed to establish a CPC in there. Would be interested to see the finished article once you have been back and installed the new sockets.
@train4905
@train4905 3 жыл бұрын
Well done dell.on sticking with it. Good on ya.
@joanofarc708
@joanofarc708 Жыл бұрын
God bless your patience mate you litrally don't know what you're walking into
@user-yw6qb9tt7t
@user-yw6qb9tt7t 2 жыл бұрын
Another great vid Del. People have comments which suggest alternatives. With 22 hindsight and some assumption that their approach would be more appropriate. Fine. Debate is good. You fixed it still and it will stay fixed now !
@zjzozn
@zjzozn 3 жыл бұрын
What a job.... well done to sort that. Perhaps a TT earth system or old earth that used incoming metal water or gas 😳
@SamHughes89
@SamHughes89 3 жыл бұрын
Gotta love del talking about getting clips on a 12 inch crawl space when the job is already a nightmare without the clips! 🙈
@slopsallover
@slopsallover 3 жыл бұрын
Man you've got some patience....confirms why I ditched domestic sparkying a long time ago ...fair play to you for taking the job on. 👍
@garrett69
@garrett69 3 жыл бұрын
Agreed. I do purely industrial electrics these days.
@therealbosstopob4l974
@therealbosstopob4l974 2 жыл бұрын
@@garrett69 What’s the problem with domestic?
@kristianbarrett7215
@kristianbarrett7215 3 жыл бұрын
Great video delroy big fan of yours keep up the good work 👍
@eastwayelectrical
@eastwayelectrical 3 жыл бұрын
Cheers Kristian. Thanks for the kind words
@jamesl1143
@jamesl1143 3 жыл бұрын
Got to be doing ZS @ DB or ZE on the first visit especially if ZS at socket is to high
@johnnyfive306
@johnnyfive306 3 жыл бұрын
Beat me to it, 100% mate
@Mainly_Electrical
@Mainly_Electrical 11 ай бұрын
Exactly
@darkbyte2005
@darkbyte2005 3 жыл бұрын
butchered CU is an understatement ..... wow... great video
@mattWallJsy
@mattWallJsy 3 жыл бұрын
Always amazing what you find! At least it's safer now!
@eastwayelectrical
@eastwayelectrical 3 жыл бұрын
Yep, there's always something new to find
@mattWallJsy
@mattWallJsy 3 жыл бұрын
@@eastwayelectrical You should see the delights im working on right now! 😳🤯🤣🤣🤣
@mathman0101
@mathman0101 3 жыл бұрын
Crazy del your a brave man fitting that clamp to the sheath. Certainly one for the DNO. If u you out work live I would have had CAT rated arc gear on, like we do in the USA. With double insulated rates gloves, face shield and fire rated clothing. No simple jobs for you Del. Get yourself a metabo chaser well worth the investment.
@McMonkeyful
@McMonkeyful 3 жыл бұрын
I agree. Not a risk I'd take. That said, a pal of mine who works for the board did the same thing as a temporary fix for me years ago. Shaved off a bit of the lead sheath & replaced the clamp that was on there for a braided TNS connection. Thing is, he'd worked for the board for many years & was qualified to work on it. I've since paid to have the meter relocated outside & they put in a TN-C-S earth. I do not recommend anyone tries this fix, even as a temporary measure!
@Tammas
@Tammas 3 жыл бұрын
There was no danger lol, it's got 2 layers of steel tape armour and that's what he temp connected to.
@markfitzgerald223
@markfitzgerald223 3 жыл бұрын
Great work Del, but why didn’t you get that lady from your last job around , she would have talk you through fixing the problems in no time 🤣
@eastwayelectrical
@eastwayelectrical 3 жыл бұрын
Haha
@PhanoftheShow
@PhanoftheShow 3 жыл бұрын
legend has it she’s still talking
@danieldelaney9062
@danieldelaney9062 3 жыл бұрын
You could ring that through to the DNO(distribution) as an emergency job, they would attend on the day to fix the earthing problem
@thomasleathley9681
@thomasleathley9681 3 жыл бұрын
Think a Ze test at the start may have been an idea del 😂 good temp fix though. Wasnt expecting as good a reading as you got 👍
@ImranKhan-cf8gs
@ImranKhan-cf8gs 3 жыл бұрын
Good job del I had a similar job like that last week downstairs sockects and 1 room upstairs wired together the the circuit was tripping every 8 or 9 hours I plugged sockect tester on some of them it was showing me live and neutral reverse but checked every sockect the connections was ok I thing there’s a joint underneath the floorboard the faults coming from I can’t lift floor he’s got new flooring I said u need to rewire the ring and separate upstairs room to radial big job now gave price for it iam not taking a chance very dodgy wiring
@ColinDH12345
@ColinDH12345 3 жыл бұрын
18:33 I started sweating and had a panic attack !!! Old TT system obviously and the earth, as you suspected, must have been an incoming water or to a stake somewhere.
@johnlishman4946
@johnlishman4946 Жыл бұрын
or probably corroded away somewhere as earth clamp's do
@shanewilson1160
@shanewilson1160 Жыл бұрын
Appreciate the videos. What a lad!
@JT-xt8bh
@JT-xt8bh Жыл бұрын
Del is the man!
@Mainly_Electrical
@Mainly_Electrical 11 ай бұрын
He really is .. Unbelievable electrician isn't he
@Improveng1
@Improveng1 3 жыл бұрын
Great work Del, and fantastic, chilled attitude and approach.
@davidclarke2513
@davidclarke2513 Жыл бұрын
As a retired sparks of 50 years I have the exact same consumer unit in my house ,its a split board and the 2 rcds and mcbs come with the board ,the problem comes when An mcb develops an earth fault it will trip the rcd therefor disconnecting everything else covered by that rcd .so that sparks swapped the mcbs to rcbs so an earth fault on an individual circuit will only trip that circuit and not multiple circuits but he should have spotted that there was no main earth cable
@Mainly_Electrical
@Mainly_Electrical 11 ай бұрын
He definitely should .
@nicolastaub8857
@nicolastaub8857 3 жыл бұрын
That's why we use tubing inside the walls all the time (it's mandatory), so you can always change, modify or repair any wiring if necessary. It's anyway really strange to see the differences in wiring between different countries. We never use rings and all our houses and flats are always three phase (3x400 Volts, so 230V per Phase)
@thepenguin9
@thepenguin9 Жыл бұрын
Typically it's a lot cheaper on the copper to just have a ring circuit
@zaxmaxlax
@zaxmaxlax 6 ай бұрын
​@@thepenguin9In 1950, maybe...? Nowadays its not even 10% of the bill. Did you ever check the price of those gourmet/designer outlets and switches people put in their homes?
@stephenmorgan1470
@stephenmorgan1470 3 жыл бұрын
Nice job so far delroy. Interested to see how you get the cables to the kitchen sockets without wrecking the tiles
@Ragnar8504
@Ragnar8504 3 жыл бұрын
I don't think there's anything you can do, unless that wall's plasterboard. Apart from that it's either take the tiles off or go trunking with pattress boxes.
@neiltrevatt
@neiltrevatt 3 жыл бұрын
Nice job Del 1thing the tv socket cable when it goes over the top of tv bracket it’s not with in the zone if you had gone left out of low level socket and the straight up to tv you would have been ok
@farmersteve129
@farmersteve129 3 жыл бұрын
I always try to make a point of checking the earthing & supply arrangements first, otherwise you just end up chasing your tail. Once I know that the earth is satisfactory at the supply end I will move on & do the fault finding at circuit level, it never ceases to amaze me how often I come across a bad main earth!
@kindkoun
@kindkoun 3 жыл бұрын
In my previous house it happened exactly same NO EARTH connection! I only found out after 12 years living in it and thank GOD nothing bad happened. At the time I was going to night college for the C&G 2330 level 2 I asked my tutor and he told me to have it rectify immediately which I did.Thank to my good teacher too.
@eastwayelectrical
@eastwayelectrical 3 жыл бұрын
Crazy story
@looking9175
@looking9175 3 жыл бұрын
Another great watch Delroy, keep them coming.
@arnoldvanblanken2594
@arnoldvanblanken2594 3 жыл бұрын
Very nice video`s!
@petersomthing9508
@petersomthing9508 3 жыл бұрын
best sparky on youtube ,
@eastwayelectrical
@eastwayelectrical 3 жыл бұрын
Thanks sir!
@JohnWilson-pd8rd
@JohnWilson-pd8rd 3 жыл бұрын
Respect for staying power man...there's probably been spurs feeding rings feeding cookers. No earth??? customer should be glad you spotted that one .
@Galileocrafter
@Galileocrafter 3 жыл бұрын
And that is why we use conduit to run electrical trough here in Switzerland.
@patthewoodboy
@patthewoodboy 3 жыл бұрын
theres a good chance that house was built before electrcity was supplied to houses
@adamg.617
@adamg.617 3 жыл бұрын
Yep she understood everything....
@ABRUSAHAELEKTRIK
@ABRUSAHAELEKTRIK 3 жыл бұрын
Nice sharing...
@arongretarbjornssonhoiriis3120
@arongretarbjornssonhoiriis3120 3 жыл бұрын
I am so surprised how often you come across the cables failing, I have never come across cables/wires failing. unless it is due to mechanical damage. most of the time a faulty on the usage end.
@paultipton743
@paultipton743 3 жыл бұрын
Is the Cooker hood ok? I was just thinking as it was close to the faulty sockets. Also if you had 36.5 ohms at the sockets on Zs is the Main earthing arrangement a TT system? I've had it at a property where the main earth was wired to the cutout MET terminal as TNC-S but it wasnt connected inside the cutout on the Dno side.
@MMG_MoonManGuitar
@MMG_MoonManGuitar 3 жыл бұрын
Solid work as always Del. Hope you're keeping well mate.
@eastwayelectrical
@eastwayelectrical 3 жыл бұрын
Cheers MMG, very well thanks. How are you?
@alanwalton5735
@alanwalton5735 11 ай бұрын
Did my 2391 as part of my training. Was surprised that there was sparks out there without it. Plus there fault finding was 💩 because of it. No wonder that we have installs like this.
@burridgeelectricalyourloca2075
@burridgeelectricalyourloca2075 3 жыл бұрын
Mate you always get these crazy jobs hahaha
@eastwayelectrical
@eastwayelectrical 3 жыл бұрын
Tell me about it
@kingcobrauk
@kingcobrauk 3 жыл бұрын
Del didn't hear you ask her "have you done anything to your house before this started" 9x10 they did and that's the problem very strange to get that many faults for no reason over night
@user-wk7wv8rn8h
@user-wk7wv8rn8h 3 жыл бұрын
Looking at the quality of the work there id guess there's a toasty junction box under the floor somewhere
@heronimousbrapson863
@heronimousbrapson863 3 жыл бұрын
Up until the 1950's, many electric systems here in Canada were unearthed; there wasn't even an earth wire.
@trespire
@trespire 2 жыл бұрын
That's mad. Just shows how much the industry has advanced.
@LAsparkTVWireTestLimited
@LAsparkTVWireTestLimited 3 жыл бұрын
How are you sooo relaxed... that was a nightmare!
@Lewdacris916
@Lewdacris916 3 жыл бұрын
need to stay calm no matter what or you cant think straight
@nitrofar34
@nitrofar34 3 жыл бұрын
Could possibly have been a TT, with the gas and water bonding looped of that earth clamp above the DB. He hasn’t kept it continuous though and looks like 6mm from the clamp.
@oozedat3964
@oozedat3964 7 ай бұрын
Ey up, just a heads up you should really remove the steal banding and connect the earth clamp directly to the lead inner sheath on the main. Will help reduce the Ze. Any earths better than no earth tho Del.
@rrenvrrenv8014
@rrenvrrenv8014 3 жыл бұрын
If there is rcd protection then a loop reading of 36 ohm's is not a reason to disconnect the power
@Mainly_Electrical
@Mainly_Electrical 11 ай бұрын
It's unsafe with an inadequate means of earthing
@paulinedaubney8052
@paulinedaubney8052 3 жыл бұрын
Poor woman had to pay twice but at least you sussed it ,good job
@Chlorate299
@Chlorate299 3 жыл бұрын
I suppose one saving grace about these old houses is you can get underneath everything to work on it.
@IllusivePrime
@IllusivePrime 3 жыл бұрын
That Cowboy Sparky who did all that should be in jail for such a crime of a job in the sparky world! Good job on the fix Delroy!
@Awynn0
@Awynn0 Жыл бұрын
Sparky?!? Ha, that has 'Builder' written all over it! 😵
@jonathanowens7252
@jonathanowens7252 3 жыл бұрын
Not a spark, but I'd have thought you'd have had to call the DNO on that one - That main incomer is ancient!
@johnlishman4946
@johnlishman4946 Жыл бұрын
defo an earth clamp for a main earth on a old cable like that mmmm
@adamsharp201
@adamsharp201 Жыл бұрын
Your opinion means nothing unless you are a qualified electrician
@jonathanowens7252
@jonathanowens7252 Жыл бұрын
@@adamsharp201 Ok...
@Mainly_Electrical
@Mainly_Electrical 11 ай бұрын
Jonathan 100% correct
@peterwalker3046
@peterwalker3046 2 жыл бұрын
I'm not a qualified electrician but my understanding was that those metal straps used for water/gas bonding are not suitable for PILC cables? Lead is a much softer metal so if you over tighten you can easily crush the live cables within. Same reason why you don't use them to earth the steel sheath on SWA. Or maybe I'm wrong? Very open to correction as I'm still learning.
@adamsharp201
@adamsharp201 Жыл бұрын
I suggest you qualify as an electrician before commenting on things you know nothing about
@SPARKY400T
@SPARKY400T 3 жыл бұрын
Brave man fitting a bonding clamp onto PILC! could you get the DNO to PME it ?
@stuartandrews4344
@stuartandrews4344 3 жыл бұрын
@@fromthetoon1602 Same here,DNO would have also upgraded cutout.
@bradleyjames3709
@bradleyjames3709 3 жыл бұрын
I think Delroy said it was all temporary.
@bradleyjames3709
@bradleyjames3709 3 жыл бұрын
Oh maybe. At least Ze must be down to a reasonable value now so it’s much safer than it was.
@r3co0
@r3co0 3 жыл бұрын
@Dusty 99 you aren't allowed to touch the pilc coming into the property as a normal spark, dodge city. Phone the dno and they will put an earth sweat for the customer for free.
@Mainly_Electrical
@Mainly_Electrical 11 ай бұрын
It's a DNO issue
@HIDLad001
@HIDLad001 Жыл бұрын
I like the old metalclad ISCO cut out.
@roostah
@roostah 3 жыл бұрын
Not a spark but enjoy the vids so apologies if this is a daft question...If the earth was non existent originally, was the remedial work on all the sockets truly necessary? Sort the earthing, kitchen and living room in turn sorted? I may be missing something not explained but that's how I took the video after all that.
@McMonkeyful
@McMonkeyful 3 жыл бұрын
I'm not a spark either but I think the tripping was due to the faulty wiring and the fact there wasn't a reliable earth was just another problem on top of that, not the cause of the tripping. I could be wrong.
@adamsharp201
@adamsharp201 Жыл бұрын
Both comments are accurate but mean nothing if you aren't a fully qualified electrician. Stick to your day job.
@roostah
@roostah Жыл бұрын
@@adamsharp201 What's yours? Trolling on YT? Nothing wrong with asking questions
@Frits1975
@Frits1975 3 жыл бұрын
Man as a sparky in the Netherlands i'm crying right now!! we only use PVC pipes put into the wall so that the wires can always be accesed or removed. The owner having to fuck all the walls up must have been so painful and costly. Is this UK standard?
@MysticShiv3r
@MysticShiv3r 3 жыл бұрын
Flippin ek Del! Your a brave man messing with that PILSSWA. Well done for sorting it but me personally I'd have batted that right back to the DNO.
@Mainly_Electrical
@Mainly_Electrical 11 ай бұрын
Absolutely
@NERTH247
@NERTH247 3 жыл бұрын
I was looking through the gap in my fingers when he was rubbing his knife on the main cable 🤣⚡
@martynb9
@martynb9 Жыл бұрын
If you were getting the same readings on the old cables does that mean the lack of main earth was the problem all along or did I miss something?
@richardmennell5745
@richardmennell5745 3 жыл бұрын
Great video Del,not sure if your supposed to clamp on to the sheath like that,shouldn’t the DNO be called to install an earth?and the chase going across to your high level tv socket is not in a zone,did you find where all them cables went to in the kitchen?3 cables in each socket and most of them down crazy,the last Electrician wants putting in prison before he kills someone.
@adrianholt1561
@adrianholt1561 2 жыл бұрын
Hi ask the DNO to provide an earth they will strip the armour exposing the lead underneath and bond the lead and armours to an earth block. Using the armours alone is the old method and earth may be lost if they corrode at any point.
@johnlishman4946
@johnlishman4946 Жыл бұрын
i was think that it's now you have damaged DNO's property it's there cable it's not on our side to just scrape away & hack at there cable
@sticky170
@sticky170 3 жыл бұрын
Still think it's a terrible system putting the wires in the wall like that. Over here everything is put in 16 or 19 mm PVC pipe. So if there is any fault you can replace the wiring. I do like the switched and seperately fused outlets.
@McMonkeyful
@McMonkeyful 3 жыл бұрын
If US & UK standards got together & combined the best elements of both, it would be the envy of the world. As it is, we both have our own peculiar set of deficiencies.
@tonyp2878
@tonyp2878 3 жыл бұрын
They both RCDs double pole is RCCB and slim one is RCBO
@Will-mp2ij
@Will-mp2ij 3 жыл бұрын
Installed by a part p kitchen fitter no doubt..
@eastpowerengineering7416
@eastpowerengineering7416 3 жыл бұрын
thumbs-up 👆
@merlin5476
@merlin5476 3 жыл бұрын
Tiled floor AND a laminate floor.... my worst nightmare .. however, having bad readings on most of the cables whilst disconnected from each other does seem a bit odd.
@jamesarney358
@jamesarney358 3 жыл бұрын
The DNO won’t provide an earth as it’s a Pilc service and are not required to provide one. The only options would be an earth stake or request a new a PME service.
@jamesarney358
@jamesarney358 3 жыл бұрын
@@totherarf sorry but maybe you didn’t understand. Why would the DNO refuse you a new PME service if you’re happy to pay for one? ie £4000
@jamesarney358
@jamesarney358 3 жыл бұрын
It really makes no difference TNS or PME. The network is all PME. That sheath is still connected to neutral in the joint.
@starman_uk
@starman_uk 17 сағат бұрын
A SNE earth from a PILC service would usually be best endeavour for pre 1972 installs if the joint connection supports it and it passes it would usually be offered but some older networks the (typically legacy ex-DC ones) the lead was not bonded across the old joints so would require either a new connection onto the passing main or at least the old joint dug and cross bonded.
@therarmann
@therarmann 3 жыл бұрын
did the rcb trip when hitting the test button?
@gbwildlifeuk8269
@gbwildlifeuk8269 Жыл бұрын
John wayne must have wired that lot up 😂😂😂
@ThePa1ch
@ThePa1ch 3 жыл бұрын
What on earth is going on with that left hand RCD being used as as a connector block? It looked like there was a neutral joined to the phase of the 32a breaker next to it...
@Kitchentotaste
@Kitchentotaste 3 жыл бұрын
This doesn’t surprise me , I meet one Romanian electrician who did 500V DC insulation resistant test without disconnecting the load and was keep asking why he had low IR test results . He blowed up fridge and microwave 🤫
@Mainly_Electrical
@Mainly_Electrical 11 ай бұрын
Quality 😂
@DutchLockPicker
@DutchLockPicker 3 жыл бұрын
Did they had outdoor lamps on that circuit?
@rubbersteve123
@rubbersteve123 3 жыл бұрын
Hard one to sort out, but we'll done
@eastwayelectrical
@eastwayelectrical 3 жыл бұрын
Thanks Steven
@malcolmcroll
@malcolmcroll 3 жыл бұрын
why can you see the buss bar -any reason Del ?
@sdgelectronics
@sdgelectronics 3 жыл бұрын
It probably was TT before.
@nitt3rz
@nitt3rz 3 жыл бұрын
That amount of damaged cable sounds like either crushed cables, or seriously dodgey junction box
@ImranKhan-cf8gs
@ImranKhan-cf8gs 3 жыл бұрын
Hi delroy I never saw a split load with rccbos madnesses crazy
@markhorton8578
@markhorton8578 3 жыл бұрын
That clamp may come loose over time, or high resistance over time especially if lead jacket. Need an earth rod as well.
@johnlishman4946
@johnlishman4946 Жыл бұрын
defo
@jasonhowe1697
@jasonhowe1697 3 жыл бұрын
1 is likely being used as a 20 amp fuse
@steverobinson8170
@steverobinson8170 3 жыл бұрын
Either originally a TT system or they used the water mains as the main earth .
@daviej8180
@daviej8180 3 жыл бұрын
Really common ....I change them everyday
@steverobinson8170
@steverobinson8170 3 жыл бұрын
@@daviej8180 always call the dno its a no charge repair and thier ilability do it yourself and an issue occurs its your nuts on the grill
@daviej8180
@daviej8180 3 жыл бұрын
@@steverobinson8170 I am the dno
@daviej8180
@daviej8180 3 жыл бұрын
@@steverobinson8170 and it does my nut right in when folk stick a bonding clamp on ...most of the time they dont realise the lead is the earth and no the armours
@McMonkeyful
@McMonkeyful 3 жыл бұрын
@@steverobinson8170 The DNO will charge for a PME connection, unless there is an existing TNS or TN-C-S that they installed, in which case they're responsible for maintaining it. I'm also DNO. It's possible different regions have different policies on this though.
@Tammas
@Tammas 3 жыл бұрын
Call the DNO to provide a proper earth. Of the lead sheath, not the armour :-)
@m101ist
@m101ist 3 жыл бұрын
A fire hazards, l can't believe this, they left a fire hazards. 😳
@Christopher_S
@Christopher_S Жыл бұрын
I'm not an electrician, so have no idea what you said. But, from how it looked in the consumer unit I guess it was really really bad.
@AkashKumar-zt5nn
@AkashKumar-zt5nn 3 жыл бұрын
sir electrician iti diplom haus wairing me what work videsh i vecancy plz
@stephen-truthseeker
@stephen-truthseeker 5 ай бұрын
Spirit orbs.
@thhtech
@thhtech 2 жыл бұрын
As an electrical engineer and electrician, i will get nightmares from this
@CbrigBear87
@CbrigBear87 Жыл бұрын
He who dares, wins. Eh, Del?
@09weenic
@09weenic 3 жыл бұрын
Aggghh - ring circuit faults 😩
@dougaltolan3017
@dougaltolan3017 Жыл бұрын
3:12 LOOK AT THE BUS BAR!!
@CraigMansfield
@CraigMansfield 3 жыл бұрын
I'd like to see what happened next
@spookyboo3164
@spookyboo3164 3 жыл бұрын
Earth's depends on what system it TNS. TN-C-S or TT normally sweated on 10min job for the authorities and they make a fortune in feez
@Cornz38
@Cornz38 3 жыл бұрын
Hehehe, i had a bad earth, 2 light sockets, 3 feet apart, 11 megaohms resistance between the patress box..
@robertmcgibbon7116
@robertmcgibbon7116 2 жыл бұрын
As it stands the DNO duse not have to provide an earth if there is no earth ,they will maintain an existing if one's is there
@kevinrobinson6055
@kevinrobinson6055 Жыл бұрын
0.8 max tns system Surly that supply authority issue I wouldn’t have left it like that
Customer: "I think the last ELECTRICIAN made a mistake"
26:03
Eastway Electrical
Рет қаралды 34 М.
Emergency Call Out - Electrical Fault Finding
26:21
Eastway Electrical
Рет қаралды 51 М.
No empty
00:35
Mamasoboliha
Рет қаралды 6 МЛН
Finger Heart - Fancy Refill (Inside Out Animation)
00:30
FASH
Рет қаралды 25 МЛН
Женская драка в Кызылорде
00:53
AIRAN
Рет қаралды 486 М.
A little girl was shy at her first ballet lesson #shorts
00:35
Fabiosa Animated
Рет қаралды 14 МЛН
Electricians day testing and inspecting one of the worst installs.
20:35
Home seller secretly films 11 estate agent valuation appointments
29:14
Moving Home with Charlie
Рет қаралды 302 М.
What is Ground? Earth Ground/Earthing
9:27
RimstarOrg
Рет қаралды 3,2 МЛН
Electrical Fault Finding In A Shopping Centre
27:42
Eastway Electrical
Рет қаралды 106 М.
Fault Finding - You Will Never Guess What It Was...
13:46
Artisan Electrics
Рет қаралды 146 М.
If I touch this tower, I die
43:19
Geerling Engineering
Рет қаралды 1,1 МЛН
No empty
00:35
Mamasoboliha
Рет қаралды 6 МЛН