Well explained. Very helpful for field staff. Thanks for sharing such valuable and practical knowledge.👍👍👍
@aftabmughal52104 жыл бұрын
Asad weldone, really informative, proud of you.
@altafrahman8548 ай бұрын
Hi
@altafrahman8548 ай бұрын
Assalamualaikum Aftab Shab khairiyat Bhai mujhay cat3412 genset engine ka speed Kaha see adjusted hota hai
@equipmentdiagnostictest59354 жыл бұрын
Good explain this concept asad bhai.
@muhammadshoaibkhan47504 жыл бұрын
Thanks asad bhai ,long live💓
@kewalsingh9934 Жыл бұрын
very helpful video sir ji thanks🌹🌹🌹🌹🌹🌹🌹
@RanaJahangir-p7y Жыл бұрын
Aslam o alaikum sir
@industrialpowersolutions1849 Жыл бұрын
Ham without et rpm kam ya ziada kr sakty hyn?
@islamicinformationandinspi2972 Жыл бұрын
اسلام علیکم سر میں آپ کی ویڈیو روز دیکھتا ہوں میرے علم میں بہت اضافہ ہوا ۔۔۔۔۔سر کیا میں جنریٹر کا یہ کارڈ کی بیٹری وائر نکال دو تو جنریٹر idle speed پر ہو جاے گا
@AsadElectrical Жыл бұрын
وعلیکم السلام۔ جی بھائی۔
@AsadElectrical Жыл бұрын
مگر اسکو ای ٹی سے بائی پاس کر کے ریٹد پر چلایا جاسکتا ہے۔
@syyednoor2774 жыл бұрын
Masha Allah.. 🤲🤲🤲 Asad bhai what is the full form of PWM and CAN. Asad bhai kya PWM faulty hone ki surat me genset over speed show kar kar faoran shut down hoga.
@AsadElectrical4 жыл бұрын
CAN= controller area network PWM= Pulse Width Modulation
@AsadElectrical4 жыл бұрын
Pwm faulty honay ki surat me engine under speed chalega low rpm pe
@syyednoor2774 жыл бұрын
@@AsadElectrical thanks..
@faheemshaikh24714 жыл бұрын
yg
@khalidraja71274 жыл бұрын
Zabrdast information thanks 👍
@alwaystruereality37532 жыл бұрын
Very good explanation sir. 🙏
@tanaji-mk5jl7 ай бұрын
Sir how to control speed of generator by external controller like one we use for synchronization
@shoukatalirafaqat1432 Жыл бұрын
Aoa sir physical classes sir leni ho caterpillar dg pr wo de sakty sir plz
@завирмансуров11 ай бұрын
Good day sir, i have remote speed convertor 140-2175 on my cat c32,from which terminals i can check the dytu cycle?
@AsadElectrical11 ай бұрын
Check on RMTE SP+ -
@завирмансуров11 ай бұрын
But what about terminal OUT,it is going to P1/J1 ECU throttle poisition sensor.
@khanjavaid87062 жыл бұрын
Thenk you Asad bhi but agar PWM card kharab ho to starting me problem hoga k nhi
@AsadElectrical2 жыл бұрын
Nhi
@AbdulMannan-oh6jx3 жыл бұрын
Maa sha Allah. Zajakallah bhi
@industrialpowersolutions1849 Жыл бұрын
Pwm me kitini range hoti hy speed ki
@tasaddaqhussain82652 жыл бұрын
sir cat 3412. 900f electronic pump waly engine k bary mn vdo bnaen us k pdm sensor ko celebrate kesy r kis software sy kren plz sir
@khanengineering478711 ай бұрын
Hi asad bhai...pwm card kia sub he generator mai laga hota hai??? Reply please
@AsadElectrical11 ай бұрын
Nhi
@carlocardenas471 Жыл бұрын
A question. Pleaee What voltage I should to find it on S and D And what voltage I should to find on 1 y 3. I don’t have any there just at Baterry
@AsadElectrical Жыл бұрын
1,2,3 is for resistance you can not find voltage. S and D terminal with battery negative you can find some DC voltage according to minimum / maximum range
@kewalsingh99345 ай бұрын
hamare yahan to permanent ismain supply rehti hai jj on condition main bhi or off condition main bhi 24 volt.
@fahadpirzada76844 жыл бұрын
good explanation sir
@naveedkhan53423 жыл бұрын
How to use on auto sync system?
@mohammadalissa82553 жыл бұрын
Please sir what about the drop settings if I want to change configuration to can
@AsadElectrical3 жыл бұрын
If you change to CAN, no need for droop
@abolfazljalambadani76692 жыл бұрын
Hi.in emcp 3.1 show in event log:throttle position sgnal abnormal. Active How fix it?
@mohammadalissa82552 жыл бұрын
@@abolfazljalambadani7669 go to my channel I have video for that
@efeozbek Жыл бұрын
Very helpful. Thanks. By the way what is the voltage level on S and D terminals connected to the ECM?
@AsadElectrical Жыл бұрын
Actually it works on Duty cycles between 5 to 95 percent
@carlocardenas471 Жыл бұрын
Can u tell us what is the voltaje we should to measure for check ur mcm is working. Ok please
@friaaamine463 Жыл бұрын
I have the some alarm fault for acc pedal n2 spn 29 FMI 13 and spn 29 FMI 8 , how can I solve this problem?
@SunilKumar-gc1st Жыл бұрын
Salam walekum We are facing throttle position signal abnormal problem in Cat 3516B genset and its running on 900 rpm but doesn't achieve rated speed. Is Pwm card faulty because we have do all check out that u explain in this video . Please suggest.
@AsadElectrical Жыл бұрын
Replace if you can replace it or you can bypass if you have ET software.
@SunilKumar-gc1st Жыл бұрын
We don't have ET software.battry voltage on PWM card is show 27 volt . Is this problem from MPU. Please reply.
@SunilKumar-gc1st Жыл бұрын
And how it will bypass
@AsadElectrical Жыл бұрын
@@SunilKumar-gc1st you should check Pwm output on S terminal with battery negative, it will show some DC voltage and turn the potentiometer. Voltage should be variable on output.
@AsadElectrical Жыл бұрын
You need change speed desired signal from Configuration in ET in order to bypass. (PWM to CAN)
@zaheerrajpoot76413 жыл бұрын
Et 3 adat kahan say milay ga
@muhmmadnaveed67342 жыл бұрын
Et program with software adapter as ka kharcha hota ak sal ka. Et buy krny ktny cost hy 🤔
@AsadElectrical2 жыл бұрын
Ye apko Dealer company hi bateyegi
@mdfarhadulislam75983 жыл бұрын
Dear Sir, assalamualikum Anwara hamatula barkatu , how are you?
@skyga4394 Жыл бұрын
If cat pwm card is bad can it make the frequence high
@AsadElectrical Жыл бұрын
Yes
@sudiptanarayanpalofficial1630 Жыл бұрын
3412 ka starting problem kaise dolve kare?
@mohammadalissa82553 жыл бұрын
I wish you explain in English
@milindgacche68432 жыл бұрын
Dear Sir How much kohm pot use
@AsadElectrical2 жыл бұрын
Probably 10 k Ohms
@rajwindersingh5623 Жыл бұрын
I have cat 3412sta generator, problem is engine over speeding,
@AsadElectrical Жыл бұрын
kzbin.info/www/bejne/moOvgXerp51grsU
@munqueezmalim9739 Жыл бұрын
Walaikum salam bhai Potentiometer kitne ohm ka laga sakta hu
@AsadElectrical Жыл бұрын
1, 2 or 10 kilo ohms
@arslan8812 жыл бұрын
today we started a new c15 open canopy engine; it was hunting, i reduced droop potentiometer on pwn module and hunting was eliminated.
@rabibinali2 жыл бұрын
Is it necessary to install PWM to synch the gensets?
@AsadElectrical2 жыл бұрын
Yes sure
@shankarsinghrawat79704 жыл бұрын
CAT 622 - 1473 position sensor connection Red, black, what wire work
@sonuansari77722 жыл бұрын
informative explaination.
@CARE_DIESEL_SERVICE3 жыл бұрын
Good Cat ka pwm jo he 24vdc suplay To outpu kitane VDC hoge
@AsadElectrical3 жыл бұрын
Output volt me variation hogi depending on throttle demand.
@AsadElectrical3 жыл бұрын
@@CARE_DIESEL_SERVICE yes dear
@CARE_DIESEL_SERVICE3 жыл бұрын
@@AsadElectrical thanks
@jayeshsavsani33193 жыл бұрын
@@CARE_DIESEL_SERVICE good information
@carlocardenas471 Жыл бұрын
How is the variation. Can u tell us. What is the normal variation value (what voltaje I should to find it 11:13 }
@muhammedirfan13564 жыл бұрын
Bhai you good
@tanveerzafar61104 жыл бұрын
A.o.A sir white bord pa jo lahk hota hai is ko dark kar
@AsadElectrical4 жыл бұрын
Lahk ?
@tanveerzafar61104 жыл бұрын
@@AsadElectrical I can not see which is write on the white board
@AsadElectrical4 жыл бұрын
@@tanveerzafar6110 ok i will try to write ticker
@tanveerzafar61104 жыл бұрын
@@AsadElectrical white bord pa writing ko ach kar safa nai ayti hai
@tanveerzafar61104 жыл бұрын
@@AsadElectrical jo white bord pa hota me us ko notebook pa copy kart how muj pat nai chalt hai aws ap ki achi ayti hai.
@hmnazmul32013 жыл бұрын
Thankyou sir... do you have any facebook page or group?
@AsadElectrical3 жыл бұрын
No dear, keep in touch here
@rahmatkhan14212 жыл бұрын
Nice 👍👍👍
@gulfamzaheergulfamzaheer66754 жыл бұрын
Great work
@mohammadazam47553 жыл бұрын
nice dear
@kewalsingh9934 Жыл бұрын
sir ji pwm ki full form kaya hoti hai ji
@AsadElectrical Жыл бұрын
Pulse Width Modulation
@kewalsingh9934 Жыл бұрын
@@AsadElectrical ok ji thanks🌹🌹🌹🌹🌹
@kewalsingh9934 Жыл бұрын
aapki help se 3516 ki prob. soulve ho gayee ji aaj thanks ji aap jiyo hajaron saal or aise hi ham logon ki help karte raho ji 🙏🙏🙏🙏🙏🙏