CATHODIC PROTECTION | Understanding Potential Measurements

  Рет қаралды 665

isiFundi Training

isiFundi Training

9 ай бұрын

Cathodic Protection engineer, Neil Webb, brings his experience and expertise on the importance of understanding potential measurements on your CP system. From negatives to unit conversions, Neil discusses the tips and tricks for accurately measuring and interpreting the potential of your system.
Find us:
Instagram @isifunditraining
Linkedin: www.linkedin.com/company/isifundi
Website: www.isifundi.co.za
Online training: www.isifundi-school.teachable.com

Пікірлер: 2
@dentalmanuk
@dentalmanuk 28 күн бұрын
Excellent discussion .. despite having CP experience we learn .. we didn't talk about 100mV shift potential Citroen
@rogeralexander4038
@rogeralexander4038 Ай бұрын
We cannot measure a potential, but we measure potential differences in units known as volts. Gibbs Free Energy explains that there cannot be zero potential as the free energy fills any void. Therefore there cannot be a negative potential so we must examine the measurement itself. If we are using an old analogue voltmeter there must be current flowing through a coil that moves a magnet on a pivot against the elastic memory of a hair spring. the pointeris fixed to the magnet and adjutment can be made to the anchor point of the hair spring to zero the meter before a measurement is made. We set the instrument zero and measure the potential difference in relation to that zero. If we are using a digital multimeter it does noh have a hair spring but is entirely electronic. It consists of a series of capacitors and resistors that can be likened to cups and byepasses. The charges pass into the cup and when it is full pass on to the next cup. The value of each resistor is known and the eletrical capacity of energy (potential) is known. The wiring is designed so that the display shows the voltage or current flowing through the resistors to complete the measuring circuit. An oscilloscope displays the path of an electron across a screen that has to zero adjusted for each reading or series of readings. It is therefore the meter that sets the zeron for each 'pipe-to-soil VOLTAGE measurement. The ground contact electrode is not a reference potential. All of this is described in detail in Module01 of the CPN on-line Corresspondence Course at the following link. www.pipeline-corrosion-control.net/CorrespondenceCourse/Module01/index.html
CATHODIC PROTECTION | TRU data
21:18
isiFundi Training
Рет қаралды 450
CATHODIC PROTECTION | Ohm's Law
22:04
isiFundi Training
Рет қаралды 162
Дибала против вратаря Легенды
00:33
Mr. Oleynik
Рет қаралды 5 МЛН
I wish I could change THIS fast! 🤣
00:33
America's Got Talent
Рет қаралды 125 МЛН
MEGA BOXES ARE BACK!!!
08:53
Brawl Stars
Рет қаралды 36 МЛН
Review of Cathodic Protection Systems at the VMT
41:07
PWSRCAC
Рет қаралды 423
MICROBIAL CORROSION & CATHODIC PROTECTION (With Dr Reza Javaherdashti)
49:54
CATHODIC PROTECTION | Data Interpretation
22:34
isiFundi Training
Рет қаралды 154
The compass no one knows how to use
14:02
The Map Reading Company
Рет қаралды 14 М.
CATHODIC PROTECTION | Don't Drive Your Cathodic Protection Too Hard
22:49
Cathodic testing UG propane tanks
4:05
Keith Goodwin
Рет қаралды 16 М.
CATHODIC PROTECTION | What Causes Changes?
23:29
isiFundi Training
Рет қаралды 165
PIPELINE FIELD JOINTS | Cold-Applied Tapes
23:23
isiFundi Training
Рет қаралды 98