For my 3D Printed tools and digital plans please visit- www.etsy.com/shop/ChadDIY Here is my affiliate link to the heater I installed! amzn.to/2YyYaOW My favorite tool in my shop! www.xtool.com/products/portable-diode-laserbox-d1-for-laser-engraving-laser-cutting?ref=ZD0p1c21pRes&variant=43897274630383
@larala68111 ай бұрын
The book provides clear illustrations kzbin.infoUgkxbnOKZBE4evMO5V2vroHeCjq6d_MV6wJO diagrams that cover many of the essential topics. The projects at the end of the book are valuable for enhancing your skills and creating your own furniture. A digital platform linked to the book that could offer the plans for other woodworking projects with the cut sheets would have been a nice addition, but overall, the book is excellent.
@chaddiy351210 ай бұрын
1/2 inch?
@marfy012 ай бұрын
Awesome video man, no music no bs. Right on! I’ve done several of these installs. The fastest safest way , use a drywall lift !
@13girraffes3 жыл бұрын
The fan turns on after the heat exchanger has reached the optimal temperature for heating. You would get a bunch of incomplete combustion while it was getting up to temperature if it fired the burner and the blower at the same time.
@chaddiy35123 жыл бұрын
Ok, thanks for the info! That makes sense and now I know I have it hooked up correctly.
@jakethehvactech20182 жыл бұрын
That’s not exactly true. While it is delayed to allow the heat exchanger to come up to temp, it has more to do with comfort (ie not blowing cold air around) than it does with combustion. The combustion fan and main fan are completely different air paths and don’t intersect with each other. You could run the main fan 24/7 and never affect combustion.
@jeeperguy42902 жыл бұрын
Also, once temp is reached or satisfied, the blower will continue to run a few minutes to help cool the heat exchanger (by design).
@jman3480 Жыл бұрын
Should there be any smell at all that the unit will put off, besides the first the first startup?
@jeeperguy4290 Жыл бұрын
@@jman3480 what kind of smell? You shouldn’t smell anything.
@mr.purple15492 жыл бұрын
Nice job. I installed my heater (different brand) (4) years ago. Followed the instructions exactly. I studied the instructions very carefully, and still struggled with the procedure-vent pipe type etc. The manufacturer was very difficult to get info from, I understand liability, so only email, no phone conversation. My heater recommended the same Cat 3 stainless steel single wall vent you used with 1/4" per foot drop. My install was exactly like yours. Thank you very much, your video has eased my mind, knowing I did it correctly. Even set the end cap horizontally like yours. I had the gas company do all the gas piping. To all viewers, please be careful, I saw a diagram at Menards that showed the vent angled "up". This is obviously for a different heater and vent type, so study the instructions. Thanks again.
@Bill-js8gf2 жыл бұрын
The menards directions are correct and follow the manufacture with the vent pointing/tilting up.
@lawrenceshdow11 ай бұрын
It should sloped up towards the termination point (outside).
@tenthdimension9836 Жыл бұрын
Nice job man. You did everything right. You used the correct horizontal stainless steel vent pipe and your gas piping is spot on.
@chaddiy3512 Жыл бұрын
Thanks, glad to hear that!
@brianquint29602 жыл бұрын
You should’ve run a flex pipe at the very end of the run into the heater so any movements you’re never going to get a gas leak the flex pipe absorbs all the start up stop start up stop I’ll look into that and maybe change it
@andrewpotter25532 жыл бұрын
Hi Chad, I have installed 3 of these units, first off when you turn your thermostat up it lights the burner then the inducer motor starts up, When it gets up to temperature the big fan comes on and blows the heat. One thing I didn't hear you mention is you have to pitch your exhaust pipe a 1/4" per foot until you reach the outside wall or the condensation from the heater will run back into the inducer motor and ruin it. The first one I installed I learned the hard way 2 years later the motor went bad and it cost me $300.00 they would not warranty it as they said the heater was not properly installed so I just want to point it out. Was a good video thanks
@chaddiy35122 жыл бұрын
Thanks for the comment, I did this on my install but must have forgot to mention it in the video. Hopefully people read the instruction along with watching videos like these.
@andrewpotter2553 Жыл бұрын
@Faith Howard pitch it downwards so the water runs away from the furnace and go outside.
@Hbombre Жыл бұрын
Mr heater installation manual says pointed up towards the termination
@hartlestud11 ай бұрын
@@Hbombre that's wrong. My manual says the same. Only pitch it up if you have a drain line attached to the pipe. Otherwise pitch it down so the condensate runs out of the hood.
@hartlestud3 ай бұрын
@@kylecasey7890 oh that's interesting. I wish they would clearly state the intent of the pitch in the manual.
@ranacherian10 ай бұрын
Did you use mr heater horizontal vent kit and what size gas line did you use?
@chaddiy351210 ай бұрын
Hello, I didn't use the mr heater brand. I think the brand I used was duravent frome Menard. I believe it was 1/2 gas line. You can download the manual for these units, it will tell you forsure. The higher btu units might need a 3/4 inch line, so you will want to double check that. Good luck!
@Uncle_Jesse Жыл бұрын
there's fan timer delay which is normal. Once the heat exchanger reaches temp the fan will engage. R and W is your heat cycle and G is your fan. The fourth wire I have no clue what that was for lol
@chaddiy3512 Жыл бұрын
Thanks for the info, I appreciate it!
@superflycatchermtb2 жыл бұрын
Nice video and Install. I’m putting the same unit in my garage. Curious why you ran the rigid supply line all the way to the unit instead of flex pipe for the last couple of feet. The rigid pipe would be much more prone to leaks in the event of earthquake or if the unit was bumped or knocked around.
@chaddiy35122 жыл бұрын
I was just following the directions it came with, so I followed that. I didn't even think about using flex line, but that would have been a little easier. The way I did it really wasn't that difficult. I live in MN so earthquakes are not a concern.
@woohunter110 ай бұрын
Plumber here, in western PA, we don’t have to worry about earthquakes so we are allowed to run hard lines all the way to the appliance, I’ve done it for furnaces, water heaters, and pool heaters. But anymore, I usually run 2 or 3 feet of flex at the connection. Saves customer money on the install and makes it easier for the next guy when it needs replaced.
@mr.purple154911 ай бұрын
Was your vent sloped up or down? If down to the heater as described in the comment below, how does it drain? Mine slopes down to the outside, and during the cold winter, I have a small ice mound in the yard. Thanks
@chaddiy351211 ай бұрын
I am pretty sure I sloped it going to the ouside. I haven't noticed any ice mounds...put I guess I haven't really looked. It does put out some nice heat!
@adamr8628 Жыл бұрын
I watched your video specifically to find out about what gas line to buy. Unfortunately he decided to skip over that part! Lol. So here I stand in the store, ready to search through another 20 minute video to find the five seconds for information I need!
@takumif70562 ай бұрын
What kind did you end up purchasing?
@bobsbarnworkshop Жыл бұрын
The blower won't come on until the heat exchanger reaches a certain temperature so it doesn't blow cold air! So it's normal for the burner to come on for a while first
@chaddiy3512 Жыл бұрын
Ok, thanks for the information...I appreciate it!
@jeremyschwalbach325311 ай бұрын
I’m looking at installing this in my garage. The previous home owner had a heater mounted similar to how you did it. Any concerns with the 2x6 coming free?
@chaddiy351211 ай бұрын
Hello, If you use some lag screws with the 2 x 6's and make sure you are screwing them into the roof trusses, I don't think there is anything to worry about. Just one lag screw can hold 100's of lbs if it is long enough.
@terryglover338 Жыл бұрын
My only question is why would you want a heater on the ceiling? I see the vents facing down, but heat rises, so it seems like your heat may never reach your legs? It seems like you would want something on the floor or mid to lower wall.
@chaddiy3512 Жыл бұрын
Hello Terry, I think the main reason everyone installs these types of heaters up high is because of how much space they take up. If you installed them lower, you would lose a lot of floor space and you could have a chance of gas, oil, chemicals accidentally getting too close to the burner.
@ceasergert2780 Жыл бұрын
Gas hangs low to flow keep furnace high not to suck in gas fumes
@davee9527 Жыл бұрын
Installation instructions say the heater must be a minimum of 8 feet from the floor to be code compliant.
@chris_cann3 ай бұрын
did you have to make a firebox in the wall when you went through the wall with the vent?
@chaddiy35123 ай бұрын
There is a metal sleeve that you can add first in the wall. Then the vent pipe can go through that.
@Bavs__2 жыл бұрын
I just got the same heater, I’m using the same pipe as you, but I can’t find the right part for the first connection from the heater? Can you tell me the part number for that heat fab style pipe?
@chaddiy35122 жыл бұрын
I don't have a part number, but I thought the small section of pipe coming out of the heater is the same size as the rest of the pipe you would use. So you just use a standard connection end for the heater, just like you would use if you are connected two pieces of pipe together
@jameslacroix5344 Жыл бұрын
Great no nonsense tutorial . Much appreciated.
@chaddiy3512 Жыл бұрын
Glad you enjoyed it, and thanks for the comment!
@johnsmith-qz4bv3 ай бұрын
did u use a deticated 15 amp line for the heater..?..
@chaddiy35123 ай бұрын
I used a 20 amp line, but 15 should be just fine as well.
@teddyruxpin38112 жыл бұрын
can this be piped into my existing hot water heater vent with a tee?
@chaddiy35122 жыл бұрын
Sorry, I'm not sure...you would have to ask a professional HVAC guy on that.
@ethanducharme28233 ай бұрын
Where did you get the vent pipe and what pipe is it? I cant seem to find gasket sealed pipe for the same job
@chaddiy35123 ай бұрын
I got all my pipe from menards, but I would think home depot would have what you need as well
@ceasergert2780 Жыл бұрын
Why did you keep it so far from the back wall?
@chaddiy3512 Жыл бұрын
Hello, I think in the install instructions it said there was a minimum distance it needed to be from the wall...so I just followed that
@neolightproductions2 жыл бұрын
I would have just used a flex line instead of Union. I probably would have put leg at inlet too. But I guess either works.
@paulhayes9622 жыл бұрын
Looks great! Thank you so much for sharing!
@chaddiy35122 жыл бұрын
Thanks, glad you enjoyed it!
@jeffdarocha39692 жыл бұрын
Regarding the blower it is correct the heater should heat up to heat exchanger a bit before the fan comes on usually about 60 to 90 sec delay
@chaddiy35122 жыл бұрын
I got it all figured out now, thanks!
@ericthompson365711 ай бұрын
Check Local code, you should have an appliance flex from the rigid gasline to the unit heater
@chaddiy351211 ай бұрын
Thanks for the tip...this is good advice. I just followed what the instructions for the heater said, but local codes should be checked out as well.
@Joeboost88052 жыл бұрын
You used a plug? Dosent have to me hardwired with a shut off switch sir?
@chaddiy35122 жыл бұрын
Yep, just used a plug. Not sure about the shut off switch part
@unclejoesusedcars9484 Жыл бұрын
The fan will not come on until the heat sensor says it should. Keeps the unit from blowing air while starting and blowing cold air. Works great
@chaddiy3512 Жыл бұрын
That makes sense, thanks!
@happylaughstv5434 Жыл бұрын
Fan doesn’t turn on right away because the burner tubes have to warm up then it hits say temperature probe that tells the fan to turn on
@chaddiy3512 Жыл бұрын
Ok, thanks for the info!
@davidfrisch55382 жыл бұрын
Just ordered this heater my self ... what's the minimum distance from the heater to the ceiling ? Also the minimum distance from the wall to the heater? Lets say finished wall and ceiling .
@chaddiy35122 жыл бұрын
I think you can download the manual from Mr. Heaters website and get all the info there, Good luck!
@davidfrisch55382 жыл бұрын
@@chaddiy3512 made me do some reading lol .. 1 inch from the ceiling, 18 inch each back corner from the wall , (vertical venting) will need at least 3 ft for horizontal (venting) 8 feet from floor to bottom of Heater .. I almost used the 3/8 rod method but my garage is only 9 feet tall. Info. for others .. good video thanks for sharing
@michaelwas85492 жыл бұрын
I'm debating if I want use the concentric combustion box with fresh air intake. It's an extra 500.00
@chaddiy35122 жыл бұрын
I would keep things as cheap and simple as possible. I don't thing any of this type of equipment will really last to long before needing replacement
@shanemarshall58533 жыл бұрын
Great install, I like the angled 2x6 and threaded rod. Do you have any info on your propane tank set-up?
@chaddiy35123 жыл бұрын
Thanks Shane! Yeah, the threaded rod was for sure the way to go. A propane company set the whole tank up for me. I just stubbed out the 1/2" black pipe outside my garage and they hooked up from there. They set a 100 gallon tank right behind my garage and ran a piece of soft copper from the tank regulator to my black pipe I had stubbed out. Works great!
@wallaceburgautoglass69492 жыл бұрын
Did you buy the vent kit or just individual pieces or did it all come with heater?
@chaddiy35122 жыл бұрын
Hello, I bought the individual pieces
@FihnIsTech2 жыл бұрын
What is needed to connect the cat 3 vent pipe to the actual heater?
@chaddiy35122 жыл бұрын
I believe it was called a slip connector that I used. There is a small piece of vent pipe sticking out of the heater so I used the same type of connector piece that I used to just connect one section of pipe to the other.
@nyst8ofmind023 жыл бұрын
Did you have to make any further adjustments to the gas pressure once you fired it up?
@chaddiy35123 жыл бұрын
Nope, it has worked perfectly the last few months keeping my garage at 50 degrees. I guess I lucked out!
@th22ek982 жыл бұрын
What Cox said, fan should kick on 30 seconds after ignition
@chaddiy35122 жыл бұрын
I got it figured out now, Thanks!
@MandeepSingh-lp3hc11 күн бұрын
Can i just put it on a stand?
@chaddiy351211 күн бұрын
I'm not sure if you can...I think there are some clearance requirements that won't allow you to have it close to anything combustible.
@ryanreischel57783 жыл бұрын
Did you use a double wall venting pipe or no? Seeing you have the wall thimble, does that act as the double wall venting pipe?
@chaddiy35123 жыл бұрын
I am no expert at this, but I believe what I used was just a single walled category 3 stainless steel piping material. The thimble does seem to act like a second wall so my drywall and siding don't get too hot from the vent pipe.
@rocket62772 жыл бұрын
Did the heater come loose yet?
@chaddiy35122 жыл бұрын
Not that I've noticed...now I might check though
@deweydurand59522 жыл бұрын
Great video and nice installation!!
@chaddiy35122 жыл бұрын
Glad it was helpful!
@tylerholthaus96362 жыл бұрын
What brand of caulking did you use?
@chaddiy35122 жыл бұрын
I used Meeco high temp silicone for the vent pipe and quad max for the siding.
@mikenorlen1252 жыл бұрын
Did you go to Two Harbors high school
@chaddiy35122 жыл бұрын
Yep...class of 2000!
@jimgunning49713 жыл бұрын
Hey Chad--Great video. Very clear presentation.Just a few questions: How big is your shop? How insulated is it and how cold does it get where you live? I live in Maine is choosing the right unit will be really important. Lastly, how much did the whole install run you? Thanks.
@chaddiy35123 жыл бұрын
Hello Jim, my shop is a little under 700 sq. Ft I have r13 insulation in the walls and r19 in the ceiling. I live in Minnesota and plan on added more blown in insulation this summer. I would guess it cost me around $800 for the whole set up and propane tank setup. I actually just called today for my first propane refill for my 100 gallon tank.
@markkallabat24742 жыл бұрын
How much is the gas bill for this heater
@chaddiy35122 жыл бұрын
I have used about 200 gallons of propane so far this year. The cost of that really depends on where you live.
@markkallabat24742 жыл бұрын
I live in Michigan
@korruptgaming392 Жыл бұрын
Cheers from Mn!
@deanl2427Ай бұрын
Thanks for sharing
@chaddiy3512Ай бұрын
You are welcome!
@syndebad34452 жыл бұрын
It disconnects after two minutes and works again and it does the same thing throughout the day and it does not reach the required temperature. I changed the ventilation tube and the same problem. I don't know if there is a defect in the industry or is there something else if you have the solution I hope you will let me know thank you
@chaddiy35122 жыл бұрын
Hello, sorry about your problems. The first thing I would try is a new wall thermostat and see if that makes a difference. Also, making sure you have the right kit for either natural gas or propane. Good luck!
@wreber742 жыл бұрын
The ear protection. Love it. Those 20v impact drills can blow your whole drum smooth out the side of your head !! Be careful buddy. Especially when they're brand spankin new like that, and every other tool in that shop. Tools that unfortunately don't come with that heater turns out. Damn. Back to Lowe's 😆 But when he lifts the safety goggles after hand tightening the bolt , that was it for me 💀
@malibustigs2 жыл бұрын
Nice job. But who pronounces caulk that way?
@chaddiy35122 жыл бұрын
Thanks, I guess I pronounce it the kid friendly way
@malibustigs2 жыл бұрын
@@chaddiy3512 LOL
@illiniwood Жыл бұрын
To lift the heater to the ceiling and maneuver it in place, rent a drywall lift. It's well worth the forty or so bucks for a one day rental, especially if you're a one man/woman show.
@chaddiy3512 Жыл бұрын
That would be the best way to do it, Thanks for the tip!
@rongreen73082 жыл бұрын
Calvincox567 already mentioned it but there is another thing you can do too. To re-iterate, The heat exchanger has to heat up first before the blower comes on. Your furnace to your home should be doing that too. The other thing is that I put mine a stick, a 1x3 or something like that. Your thermostat probably says it must be level. Here is a 2 part trick. The thermostat is on the stick to get away from a cold wall so that it reads temps in the garage and not colder wall temps. Here is the other trick, I put that stick in place with only one screw at the top of the stick. This allows me to swing the stick to adjust the level of the thermostat. I used a second screw to limit the swing. This allows a preset "new" calibration of the thermostat. The thermostat will only go down so far, mine is 50 degrees. I live in Chicago where temps get to -20 or colder and the cars may not start. By swinging the thermostat, I can now turn that 50 degrees minim temp to 30 or less so that I dont have to heat the garage to 50 degrees to start the car. I actually have my limiter to where I can maintain a minimum temp of 0 degrees and my car will start ok To recalibrate the thermostat to normal I only have to push it the opposite way to the limiting screw I have screwed in on the other side of the joist that the stick is mounted to. By using this swing method, I can change my thermostat in about 1 second so that I dont have to heat my garage my garage to a minmum of 50. Of course you could adjust yours to whereever you want. I put that thermostat a little higher than normal so it is out of the way. I actually have a 120,000 btu Bryant that I got only 4 years old and rarely used as a supplemental heater in a carpet warehouse. I got it for only 200 bucks. I know 120,000 is way high but I take the chill out in only 10 minutes on a very cold day. This way it doesnt run for an hour or more to reach temps. It is there almost immediately when I need it and is not something that I have to plan on hours earlier. I like your heater. It should be good for you. My friend uses a 30,000 in his garage. It works great but takes a while to warm everything up, especially if he brings in his cold car from the outside. Good luck.
@chaddiy35122 жыл бұрын
Thanks for all the info and tips!
@rabeasaab7631 Жыл бұрын
Us longer threaded rods then cut them shorter after
@chaddiy3512 Жыл бұрын
Great tip, thanks for that!
@chrismcklveen75052 жыл бұрын
What did this roughly cost for the whole install?
@chaddiy35122 жыл бұрын
Hi Chris, I think I spent around $800 for everything, including the cost of the heater
@valdivia88063 жыл бұрын
You didn’t put a flashing on the green treated board outside
@chaddiy35123 жыл бұрын
Yeah, I suppose there should be some metal flashing on the top of the pressure treated atleast... good tip!
@cardboardorigami3 ай бұрын
You should NEVER reach like that on a ladder (when you were doing the caulk outside)
@videos10 Жыл бұрын
I quit watching as soon as he said he's never installed a unit heater, never vented. At least thanks for the honesty.
@ceasergert2780 Жыл бұрын
He did a great job
@rolandrochon3432 жыл бұрын
After watching your video, I when and purchased the “Heat Stare 80,000 BTU” at Princess Auto. We had to convert it to Propane (included in the kit w/bigger Jet .042 and a different regulator spring.) Then we have calibrated it to 10” as per instructions. …“This is the worse Heater I ever installed in my career.” There is more heat going out the vent than the front of the heater. My conclusion is about 20% front heat and 80% wasted heat out to the vent. What a waste of our time. The next day I returned it to Princess Auto for a full refund. I recommend you check yours.
@nickbisson82432 жыл бұрын
Different heater.....
@Joeboost88052 жыл бұрын
Sounds loud
@troubledseed Жыл бұрын
For anyone thinking of doing this. Use 2 pulleys that you temorarily install to hoist it up then fit it in place.