No video

Changing a Compressor On a Mini-Split Air Conditioner!

  Рет қаралды 16,332

HVAC GUY

HVAC GUY

Күн бұрын

In this video I return to a call where I diagnosed a faulty compressor 2 months ago! #hvacguy #hvac #airconditioning #hvaclife #electrician #airconditioner #hvactrainingvideos #hvaccompany #hvactroubleshooting #skilledtrades #bluecollar #bluecollarpride #minisplit ‪@FieldpieceProducts‬ ‪@MilwaukeeTool‬ ‪@mideaairconditioning4011‬ #compressor
Merch Store : hvac-guy-2.cre...
Here are links to the tools I use, And it costs you nothing extra to buy from this list:
Makita Wet/Dry Vac: amzn.to/3VVHpsz
Veto OT-LC: amzn.to/3wSK1Nj
Appion AV760: amzn.to/3OkrwHC
Fielpiece SC680 Clamp Meter: amzn.to/33rhxvE
Fieldpiece SC480 Clamp Meter: amzn.to/33kfgCB
Fieldpiece SMAN 480 Digital Manifold: amzn.to/3twfVvA
Fieldpiece DR58 Leak Detector: amzn.to/3nt1TXw
Fieldpiece JL3KM2 Bluetooth Manometer set: amzn.to/3blMrJR
Fieldpiece Bluetooth Scale: amzn.to/3Gzveab
Fieldpiece SDMN6 Manometer: amzn.to/3qwk9RP
Yellow Jacket Tubing Expander: amzn.to/3sjuK3a
Milwaukee M12 Impact Driver: amzn.to/37xXkqk
DIY Vacuum Attachment for drains: amzn.to/3tDpfNU
Fieldpiece Smart Probe Kit : amzn.to/34NG3HL
Klein Heavy Duty Wire Strippers : amzn.to/3I8YNzT
Klein Needle Nose Crimpers/Stippers: amzn.to/3fuwXlw
Klein Knee Pad: amzn.to/3cy6FB0
Klein 7in1 Flip Socket: amzn.to/3bpabwG
Klein Journeyman Pliers: amzn.to/3tvB60w
Milwaukee Slim Packout On My Torch: amzn.to/3KeLm3j
Aluminum Packout Wall Mount on torches : amzn.to/3Kf9hQg
Milwaukee Tool Box: amzn.to/322iyK9
Veto Pro Pac Tech MCT: amzn.to/3nwwQdA
Milwaukee Hook Blade Knife: amzn.to/33F3m5T
Testo 300 flue gas analyzer: amzn.to/3IcS3Bd
Western Nitrogen Regulator: amzn.to/3rmdKrx
Klein Canvas Bucket: amzn.to/3FyzKVf
Flag Velcro Patch Kit: amzn.to/3K8Eswx
Supco Magnetic Door Switch Holder: amzn.to/34IcXcL
Milwaukee Magnetic Light: amzn.to/3FulCfF
Milwaukee Rechargeable Headlamp: amzn.to/3nuXsvf
SS2 Float Switch: amzn.to/3K7LJMW
3-Amp Breaker: amzn.to/3nxaSXJ
Appion Valve Core Removal Tool: amzn.to/33CFArw
Appion G5 Twin Recovery Machine: amzn.to/33Dvd6C
Yellow Jacket Large Tubing Bender: amzn.to/3qwJv1U
Similar Small Tubing Bender: amzn.to/3fJsziJ
Fluke Twist Guard Test Leads: amzn.to/3216R6j
Honeywell T-4, 2-Heat, 1-Cool Programmable Thermostat: amzn.to/3qtIuaX
Kidde Carbon Monoxide Alarm: amzn.to/3qtIIyP
SolderWeld Flame Resistant Magnetic Blanket: amzn.to/3qtJ4Wb
Malco 1/4 - 5/16 flip bit : amzn.to/3nr67yU
Quick Check Acid Test: amzn.to/3GA2XAy
Wiha Torqe Screwdriver : amzn.to/3u1swH6
Wiha Torqe Screwdriver 1/4” adapter: amzn.to/3IH22Pw
Compressor Tote: amzn.to/3H8xHst
Inspection Mirror: amzn.to/3r9PERV
Wiha TorqueVario-S 10-50 in/lb Torque Screwdriver : amzn.to/3GbKAku
1/4” adapter for Wiha Torque Screwdriver : amzn.to/3u8g0pq

Пікірлер: 129
@StringDriver
@StringDriver Ай бұрын
Curtis, I wish to pay you a compliment… I just clicked “do not recommend channel” for Non DIY HVAC… for one main reason: Ted is so disrespectful at times, talks smack about his PAYING CUSTOMERS and is generally too full of himself for my liking. You have massive skill and experience and you display NONE OF those DB qualities that Ted can’t seem to bring himself to stop. Nicely done work. Polite and a lack of egomania. From one tradesman (frame and finish carpenter) to another… WELL DONE. 👍🏼
@HVACGUY
@HVACGUY Ай бұрын
Thanks
@Paul-IE-Repairs
@Paul-IE-Repairs Ай бұрын
ted cook is what you call old school
@blh3741
@blh3741 Ай бұрын
I don't mind Ted C. and his attitude towards DIY, he's not posting videos for DIY'ers. But his info is still teachable to anyone who takes the time. Most HVAC distributors in Calif will not sell anything to DIY, refrigerant related or not. I'm retired/disabled and it took a while to connect with a distributor who will sell to me. If you want an arrogant D.B., it's Mikey Pipes. Curtis is educational and humble. He's in my top 5 YT'ers
@ChipWoodsworth
@ChipWoodsworth Ай бұрын
​@blh3741 I like Mikey Pipes videos, but I have noticed as of recent, that every business he merges with, or aquires, ends up with no employees, and the business partner, or previous owner ends up no longer working there. At first, I didn't think much about it, but after a few times, I think his problem lies in the mirror.
@scottjones7279
@scottjones7279 Ай бұрын
That tight spot that you were brazing in looked like a good place for Staybrite8
@boatingcharlie1
@boatingcharlie1 5 күн бұрын
That noise when the rubber plug popped out (9:32) sounded like a cartoon sound affect. lol
@HandSolitude
@HandSolitude Ай бұрын
Love how you used the oxyacetylene to chase off that bug.
@mrsmith5114
@mrsmith5114 Ай бұрын
Love to know the price of this job. I would think it be cheaper to buy a new mini split than replace the compressor. Even more so if the compressor wasn't under warranty.
@Djcarp83
@Djcarp83 Ай бұрын
Yes and all the dc shit and exv’s, drier and all of the other bs that come with those!!!! Just buy a new one
@mrsmith5114
@mrsmith5114 Ай бұрын
@@Djcarp83 Plus new warranty. But yeah, would love to know.
@anthonyrauseo5913
@anthonyrauseo5913 Ай бұрын
Home warranty company would rather pay $50 less to fix the old then the additional $50 it cost to get brand new lol
@davidwatson962
@davidwatson962 Ай бұрын
Do you use flux on you soldering joint
@stevee7774
@stevee7774 Ай бұрын
@@davidwatson962- He’s brazing the joints so no need for flux.
@user-yw9wn2vx6y
@user-yw9wn2vx6y Ай бұрын
That relief on your face says it all..
@kens.3729
@kens.3729 Ай бұрын
Thanks for your persistence with getting this Mini-Split Operational again. Thank GOD they had two (2) window Units. We have one (1) Heat Death in STL so far. 🙏
@UncleEarlHeatingAirCondition
@UncleEarlHeatingAirCondition Ай бұрын
Nice of you to share, as always. Just info, A Captain Hook tip by Uniweld works perfectly on these for brazing tight locations. There is a learning curve, but you should give it a try . It comes in 3 different sizes ( part numbers NTF-5, NTF-9, NTF-17 ). I thought you might have one when you said "break out my Hook", but never saw it
@zunar_j5_933
@zunar_j5_933 Ай бұрын
What a pain in the arse job! Well done.
@daeroc
@daeroc Ай бұрын
Love it when it all goes according to plan
@key-sendo
@key-sendo Ай бұрын
That third bolt in the back for the feet of the compressor and getting the crankcase heater back on have to be some of the hardest things to do in hvac 😂😂😂
@Fluorescentlighting123
@Fluorescentlighting123 Ай бұрын
Hello love your videos keep up good work!!!
@HVACGUY
@HVACGUY Ай бұрын
Hey, thanks!
@stephenbullock-yn3vh
@stephenbullock-yn3vh Ай бұрын
Super excellent work curtis 👍👌✌️
@HVACGUY
@HVACGUY Ай бұрын
Thanks 👍
@jme36053
@jme36053 Ай бұрын
Makes you wonder if the compressor issue was partly caused by mis-wiring earlier.
@Balticblue93
@Balticblue93 Ай бұрын
100%!! I bet the other compressor wasn't bad, but wired incorrectly. That is why it didn't fail his ohming testing.
@mikar3601
@mikar3601 Ай бұрын
@@Balticblue93 ooof!
@jimdavis6833
@jimdavis6833 Ай бұрын
I feel cooler already.
@SpecialistOne
@SpecialistOne Ай бұрын
Customers really need to tell you that they had someone look at the condenser. That person may have disconnected the wires to do a ohm check and was careless to put them back on correctly. So, may be it was a bad board and a good compressor, but not knowing what went on before you, makes the job harder to diagnose and fix.
@kennymayo4578
@kennymayo4578 Ай бұрын
Good braze job, i always seem to struggle in those tight areas
@TomLawson05
@TomLawson05 Ай бұрын
Great change out Curtis glad all went well on to the next thanks for the video
@dsnow2835
@dsnow2835 Ай бұрын
Did a compressor aswell today in Charlotte, NC. It was hot as heck. Good work as always.
@HVACGUY
@HVACGUY Ай бұрын
Thanks 👍
@bobboscarato1313
@bobboscarato1313 Ай бұрын
Good job Curtis; tight spot and bugs all over!
@uncledandaunteaunplugged2232
@uncledandaunteaunplugged2232 26 күн бұрын
When i have to do that repair i take the panel over the fan, fan and center divder out makes everything so much easier
@stevencossaboon3237
@stevencossaboon3237 Ай бұрын
Nice work Curtis. Mini splits suck even more when its hot.
@Boston_canon
@Boston_canon Ай бұрын
In my place usually just replace the outdoor unit , glad to see people who have skill like you
@gurskysgarage
@gurskysgarage Ай бұрын
Nice work keep up the good videos!
@HVACGUY
@HVACGUY Ай бұрын
Thanks, will do!
@chrisnapier5626
@chrisnapier5626 Ай бұрын
Great job,Curtis!
@HVACGUY
@HVACGUY Ай бұрын
Thanks!
@ntsecrets
@ntsecrets Ай бұрын
I looked in the manual at one of the popular midea clone units that use those gmcc compressors and the terminals didn’t seem to matter on the compressor because it’s 3 phased and same impedance on all terminals. And from what I understand the rotation on those doesn’t matter. But I am all for hooking the right wires to the right place! Might just come from the factory that way.
@robalexander7348
@robalexander7348 Ай бұрын
Well done Curtis, that sure was a tight area to work in 😣 Au
@jamienoel
@jamienoel Ай бұрын
Watch out for ticks working in the grass like that.
@stevee7774
@stevee7774 Ай бұрын
Ticks, chiggers, and snakes!
@bobchamp3159
@bobchamp3159 Ай бұрын
You know, its always hard to make the judgement call, but really the board could have been bad which leads to compressor to fail. Anyway, either way it gets a new board now. Nice job
@davidb2438
@davidb2438 Ай бұрын
Cheaper to throw it out and install new condenser
@Johnnyreengo
@Johnnyreengo Ай бұрын
$2500 to replace a compressor? Really?
@icandreamstream
@icandreamstream Ай бұрын
I have one of the older midea inverter mini split units, it has a 3 ton Mitsubishi compressor in it. Shocked to see high quality parts in some of those Mideas.
@anthonyelectric6045
@anthonyelectric6045 Ай бұрын
That was a hot mess of a job for sure. The heat really takes its toll and good thing for that portable fan. Although it needs a a/c switch setting 😅
@krishuntzeroable
@krishuntzeroable Ай бұрын
I totally feel ya having a fan blowing on you outside. It’s that bad out here.
@search_eternal
@search_eternal Ай бұрын
Nice job. I was confused by the pressures being the same then remembered those units only have low side ports LOL.
@harrydickson4575
@harrydickson4575 Ай бұрын
Awesome job 👍👍👍
@HVACGUY
@HVACGUY Ай бұрын
Thanks 👍
@Infowarrior-45
@Infowarrior-45 Ай бұрын
I had a Carrier mini split with similar issues. Compressor checked fine, but every time it was powered up, it blew the fuses in the disconnect. If unplugging the Compressor, it wouldn't blow the fuses. Carrier tech support argued with me that the Compressor, being DC voltage, shouldn't blow a fuse. After explaining to him that I had already replaced the board, he agreed I should replace the Compressor. I guess we'll see, when it arrives if I am right or not.
@charlesmcadory8286
@charlesmcadory8286 Ай бұрын
If you have problems with wasp, this is the best wasp spray I have ever used. BASF - 597802 - PT Wasp-Freeze II - Wasp and Hornet Insecticide
@paulsmalser3261
@paulsmalser3261 15 күн бұрын
One thing I have always told people is never do business with someone who acts like they are Gods Gift to whatever trade it is, their ego will never allow them to be wrong and so you will have to pay for their screw ups. As for me personally I know I only walk on water during cold winters.
@tonyhvactechinian_
@tonyhvactechinian_ Ай бұрын
I have a Mitsubishi mini split that keeps going into defrost mode. I’ve changed the sensors and the board and still doing the same thing. It works fine in cooling.
@Bob.W.
@Bob.W. Ай бұрын
Had to replace both boards on our Carrier Mini-split (Midea) after a lightning strike got into the house wiring. Touchy stuff.
@sprockkets
@sprockkets Ай бұрын
Where is the sensor?
@bobbyr8071
@bobbyr8071 Ай бұрын
That Milwaukee vacuum pump is so expensive. U can get a 1kw battery pack and a compressor for that much. The battery pack can be used to power other tools
@HandSolitude
@HandSolitude Ай бұрын
I take it that was a multi head split system which is why it was worth repairing rather than replacing?
@HVACGUY
@HVACGUY Ай бұрын
Yes
@skyman2002
@skyman2002 Ай бұрын
GMCC compressors... they use those in the Midea made products, Dehumidifiers, Window units, portable units ETC.
@HVACGUY
@HVACGUY Ай бұрын
Well, this is a midea product
@jordenb9469
@jordenb9469 Ай бұрын
Gmcc compressor company was once Toshiba. They are very inexpensive compressors used in every brand in the world. I mean every brand. Quality is very good for the price point.
@sprockkets
@sprockkets Ай бұрын
​@jordenb9469 well, not gree, or Mitsubishi, or fujitsu, or daikin, or their rebrands.
@jordenb9469
@jordenb9469 Ай бұрын
​You sir are incorrect. I suggest you take the sound blanket off thenm and see for yourself. Not all but alot have the gmcc compressors. Gree flexx is one. ​@@sprockkets
@sprockkets
@sprockkets Ай бұрын
@@jordenb9469 gree flexx uses a zhuhai compressor, just like every gree product.
@osvaldomcs1213
@osvaldomcs1213 Ай бұрын
A bit more gas. 😂😂
@caru3257
@caru3257 Ай бұрын
I did a Bosch compressor and they are a pain.
@ntsecrets
@ntsecrets Ай бұрын
I’ve had 2 of these die on me pretty much identical to the unit you are servicing. The smaller units are so cheap it’s easier to just replace the whole unit. But I wonder if I should try this? lol.
@Djcarp83
@Djcarp83 Ай бұрын
Purge purge purge purge
@famousdude1239
@famousdude1239 Ай бұрын
You didn't even take a rag and wipe the bottom of the condensing unit, just mounted the compressor directly over the dirty bottom???
@manuelcirino1456
@manuelcirino1456 Ай бұрын
Curtis why don’t change just the outside
@bobboscarato1313
@bobboscarato1313 Ай бұрын
Maybe compressor is still in warranty!
@tekjunkie28
@tekjunkie28 Ай бұрын
Multi header unit
@bobboscarato1313
@bobboscarato1313 Ай бұрын
@@tekjunkie28 Thank you!
@Djcarp83
@Djcarp83 Ай бұрын
A little Fajine gas never hurt no one 😂
@ezalku
@ezalku Ай бұрын
any inputs of why is the pressures equally at the end ? ohh 2 on low pressure side 😅
@HVACGUY
@HVACGUY Ай бұрын
Both are on suction of different circuits
@ezalku
@ezalku Ай бұрын
@@HVACGUY thanks ✌
@Browner19
@Browner19 Ай бұрын
Someone else was there and put the wires on wrong, oops
@christopherreus7799
@christopherreus7799 Ай бұрын
Hello Curtis
@HVACGUY
@HVACGUY Ай бұрын
What’s up?
@christopherreus7799
@christopherreus7799 Ай бұрын
@@HVACGUY not much been hot here keep up the good work love your vids and your a hard worker 💪
@m9ovich785
@m9ovich785 Ай бұрын
HAHAHHA You heard Me shouting, Cut the Pipe off, No need to worry about chips going into the old Compressor ... Do You have Circle Flame head ??
@iyaayas200
@iyaayas200 Ай бұрын
aren't those DeWalt fans great? I love mine
@HVACGUY
@HVACGUY Ай бұрын
Love it
@MarcHord-mk5ff
@MarcHord-mk5ff Ай бұрын
I hope it paid good, it looked brutal. I think I’ve done one compressor in mini split. My price is high now.
@TooCloseSeries
@TooCloseSeries Ай бұрын
You need a block of ice in front of that fan. 😏
@donaldhoudek2889
@donaldhoudek2889 Ай бұрын
I guess my question would be, Why don't the manufactures put a screw-on fitting on the compressors, it would make it so much easier to replace a compressor. I installed an air conditioner in my '65 Mustang (all screw-on fittings) and 20 years later it was still working great so it can't be vibration issues. It would have been so much easier to replace the compressor with fittings and not have to solder it. Great video!
@houptee
@houptee Ай бұрын
Fittings cost more than a swaged brazed joint. They are making thousands of these units a week in China. They don't care about the technicians that have to work on them. These minis are basically throw away machines when they have major problems you can order the entire system with indoor unit online for under 1000 bucks. The off brands are even cheaper and they are made by Midea or Gree.
@RobertTuck-vo8cw
@RobertTuck-vo8cw Ай бұрын
Why don't mini splits use a filter drier? (I know that external lines are not liquid lines} OI thought that you would test for acid.
@RongDuck
@RongDuck Ай бұрын
Hey Curtis. Random question. Milwaukee everything. DeWalt fan. Sup with that?
@greatbiggiesize3644
@greatbiggiesize3644 Ай бұрын
I was wondering the same thing
@optionstraderman
@optionstraderman Ай бұрын
Hmmm, no new dryer on this one after compressor change??? Is that normal for Mini Splits?
@kevinmills5293
@kevinmills5293 Ай бұрын
U can C why they are called MINI split.
@CT-vm4gf
@CT-vm4gf Ай бұрын
You call air conditioners mini splits in the US, is that because the outdoor unit is smaller than other units?
@HVACGUY
@HVACGUY Ай бұрын
This style, which is normally non-ducted we call mini splits.
@rustyhooks
@rustyhooks Ай бұрын
I see your DeWalt fan, how do you like it?does it help stay cool
@chrisscott1547
@chrisscott1547 Ай бұрын
Spend $150 on a Harbor Freight hi-vel fan and run it off a cheater cord. It will put out 10x the air compared to that battery fan.
@bigscout1584
@bigscout1584 Ай бұрын
What is the red rubber band for?
@Dr2Rock2
@Dr2Rock2 Ай бұрын
Whats the springy thingy you took off first for?
@mikemaki1104
@mikemaki1104 Ай бұрын
What is the brand of the mini split
@nicolasmuniz9452
@nicolasmuniz9452 Ай бұрын
MPN, never heard of it but probably the cheapest the mfg housing builder could find, any reg split system would be better.
@HVACGUY
@HVACGUY Ай бұрын
It’s a Midea product
@jujuanddaddyflash7773
@jujuanddaddyflash7773 Ай бұрын
Why didn't you just change the condenser? It's 2 flairs
@sziltner
@sziltner Ай бұрын
Those mini splits look like a pain. And ??? Quality! 🙄
@SeatonHeatingAC
@SeatonHeatingAC Ай бұрын
What happened to my comment?
@cornbread1955
@cornbread1955 Ай бұрын
👍👍👍😎☕
@panamacitybeachbum
@panamacitybeachbum Ай бұрын
6 out of 10 pain in the butt.
@fernandobazan829
@fernandobazan829 Ай бұрын
At least you admitted it but you never tested the compressor once it was out like you said you would? I bet it was still good operator error? no wonder you were relieved when it worked lol I hate those mini splits pos for sure good video might want to use one of those 10x10 canopy next time no sense heat stroking out never be able to enjoy your retirement my grandpa said a man who takes short cuts always takes two paths
@tomclements7590
@tomclements7590 Ай бұрын
Waist of time and money labor compressor freon headach would have put new unit in.
@DabblelyDiddly
@DabblelyDiddly Ай бұрын
glorified window unit.
@professionalinspectionserv9468
@professionalinspectionserv9468 Ай бұрын
I thought mini splits no longer brazed and were all connections to prevent contamation? Or is that newer ones? I was waiting for you to melt some wires...
@lynnprince6635
@lynnprince6635 Ай бұрын
FYI, use a rosebud tip for compressor removal only.😮
@namskramskram6009
@namskramskram6009 Ай бұрын
How long are you pulling vacuums with that thing?
@lynnprince6635
@lynnprince6635 Ай бұрын
Vacuuming is not done by time , but by microns.😮
@namskramskram6009
@namskramskram6009 Ай бұрын
@@lynnprince6635 mmmhmmm... and some vacuum pumps do it quicker than others... lol
@chrissipple1018
@chrissipple1018 Ай бұрын
Another crap mini split system.
@harryschrysan3183
@harryschrysan3183 Ай бұрын
I had to do one of those on top of a ladder. Fuck that shit, I called my boss to help me. I ain't killing my self. 😡
An Unusual No Cooling Call
22:56
HVAC GUY
Рет қаралды 154 М.
Odd Complaints Lead to Scary Find! #hvacguy #hvaclife
29:11
HVAC GUY
Рет қаралды 85 М.
КТО ЛЮБИТ ГРИБЫ?? #shorts
00:24
Паша Осадчий
Рет қаралды 1,4 МЛН
Yum 😋 cotton candy 🍭
00:18
Nadir Show
Рет қаралды 7 МЛН
🩷🩵VS👿
00:38
ISSEI / いっせい
Рет қаралды 23 МЛН
Magic? 😨
00:14
Andrey Grechka
Рет қаралды 16 МЛН
How to replace mini split compressor and inverter board?
32:20
Taddy Digest
Рет қаралды 21 М.
Budget Mini Split Installation for Beginners! w/ Vacuum Pump and Gauges
19:47
DIY Solar Power with Will Prowse
Рет қаралды 343 М.
Problems Hiding In Plain Sight! #hvacguy #hvaclife
39:21
HVAC GUY
Рет қаралды 57 М.
She Was Told She Needed a New System. Not Exactly What I Found!
31:11
КТО ЛЮБИТ ГРИБЫ?? #shorts
00:24
Паша Осадчий
Рет қаралды 1,4 МЛН