Chinese diesel heater Don't make this big mistake!

  Рет қаралды 195,923

Llord Jackson & Buzz the dog.

Llord Jackson & Buzz the dog.

Күн бұрын

Пікірлер: 301
@steveclark..
@steveclark.. Жыл бұрын
Not many people admit or show their mistakes, hat's off to you.
@2hacksbuilding82
@2hacksbuilding82 Жыл бұрын
It's the sign of a wise person
@gizmo1252000
@gizmo1252000 Жыл бұрын
i luckily managed to buy a Chinese diesel heater off a guy that had lived in china ,he worked there as a English teacher ,and he bought a heater while over there , the one i got was specifically made for the Chinese market . seems to be better made ,and strangely it has 8 heat settings on it . which makes it very fuel efficient . even the fuel lines where the solid ,harder lines that most people had to upgrade to . it,s worked perfectly since i,ve had it ,that,s about 18 months now . on the lowest setting it,s so quiet . here,s a tip for you ,i know this will sound strange ,but get a small fan and run it on low ,and put it somewhere where the heat from the heater main heat pipe points to. ,then angle the fan to a space where heat does,nt reach and it will blow the hot air even further into the space . i found it speeds up the heating of an area .weird i know ,but it works .
@tonycamplin8607
@tonycamplin8607 Жыл бұрын
The main reason for using so much fuel is that you've got the unit outside and so drawing in freezing cold air into the heating unit. Put the heater inside and just have the exhaust outlet outside. These units are designed to be used inside.
@peggenlejoncar9529
@peggenlejoncar9529 Жыл бұрын
You must have inlet and exhaust on outside for combustion camber, only heater inside which drag air from in room and pushing hot air out in room.
@tonycamplin8607
@tonycamplin8607 Жыл бұрын
@peggenlejoncar9529 I disagree. My oil fired domestic central heating boiler for instance draws its air from inside my house and exhausts it outside. I think that they all work like this, they do in the UK anyway.
@nigelskinner8799
@nigelskinner8799 Жыл бұрын
I'm not quite sure why you don't install the pump vertically or 90°....45° is the minimum not the optimum.
@snipersnightmare
@snipersnightmare Жыл бұрын
Then you get fumes going inside throught the air intake when get e6 error and it shuts off
@tonycamplin8607
@tonycamplin8607 Жыл бұрын
@@snipersnightmare As I said previously all domestic oil fried boilers that I know of draw air from inside and only the exhaust is exited outdoors. They're designed to fail safe.
@davidsteele3037
@davidsteele3037 Жыл бұрын
The guru for Chinese heaters is John McK 47. His videos are a must watch if you have problems. He says you can have the pump vertical but not upside down. Flat out you'll use 360ml per hour.
@tricks1515
@tricks1515 Жыл бұрын
Recirculate the air from inside . Fit another vent so it can draw air from the room back through the heater . Warming warm air then 👍
@robertberin4872
@robertberin4872 Жыл бұрын
what size hose did you use for the inlet? Its not 3 inches like the outlet.
@2hacksbuilding82
@2hacksbuilding82 Жыл бұрын
Great video sir. I'm currently assembling mine and I'm glad to have this info before I decide to run it for the first time
@drfoster3753
@drfoster3753 Жыл бұрын
Bought one of these things 2 years ago, Not rocket science to set up , Worked well ,heated my small shed very well. Then i moved it go another part of the shed , ironically because the exhaust was near the door, and i thought I might gas myself. Long story short, Because I'd already set it up and ran it , I just undid the exhaust pipe , , and fed it through the wall from the outside , Then I connected it to the heater, and went away to finish the job the next day, Totally forgot to tighten the clamp on the pipe and started running the heater. Over the next few days I started getting very tired , then I started getting dizzy and forgetful,, Then about 3 weeks after I first fitted the heater I went to bed one night ,and woke up in A and E, after having a massive fit in my sleep. I've since been told im epileptic, Just a simple mistake, my fault totally, not blaming anyone but myself, Nearly cost me my life. Take care .
@wilwert1746
@wilwert1746 Жыл бұрын
Right think safety even over heat.too many die from shortcuts.
@bigoldgrizzly
@bigoldgrizzly Жыл бұрын
Thanks for the posting mate and sorry to hear your troubles - your post could save someone else [or their family] serious grief. One thing absobloodylutely essential for everyone who has any bit of equipment where combustion is involved, get a Carbon Monoxide detector / alarm - they are only 20 Quid or so and that's three parts of four fifths of f*ck all to spend, when it could save your life. For around forty quid you can get a CO meter with readout in parts per million and these are great for making fuel/air adjustments that will really get your heater running at top efficiency and fuel savings should pay for itself in the first winter of running. All the fuel savings you could make using these brilliant little heaters ain't enough to pay for your funeral - be safe and get a detector/alarm.
@daveadams4109
@daveadams4109 Жыл бұрын
It best to mount fuel pump on a rubber a.v mount to cut down the sound and more importantly the vibration. The air intake needs to be piped from the inside ,this will improve efficiency by 50%
@neilblake9793
@neilblake9793 Жыл бұрын
the big problem I had was the exhaust leaking on the joints solved it by using an exhaust sealer on the joints. any car part shop will have it for around £3 a tub .started to get a head ak after 1 hour of running the heater. put a co2 in workshop and was read high
@juliogonzo2718
@juliogonzo2718 Жыл бұрын
That press was a little under powered for that bracket. I recommend at least a 50t press for that.
@llordjacksonbuzzthedog.4845
@llordjacksonbuzzthedog.4845 Жыл бұрын
Controlled pressing 😉😉
@michellecronin7480
@michellecronin7480 Жыл бұрын
He also butters he's bread with a sword!
@chrismutlow1
@chrismutlow1 Жыл бұрын
Omg I always use hammer. That’s here I’ve be going wrong lol
@tracygeddes5867
@tracygeddes5867 Жыл бұрын
@@2hotscottpro great answer,couldn’t stop laughing,but with him,not at him ,great video!
@gewild
@gewild Жыл бұрын
@@tracygeddes5867 m
@Bryan-Hensley
@Bryan-Hensley Жыл бұрын
If you have any more issues with the fuel flow, those pumps aren't good at sucking, you might need to lift the tank up closer to the pump or the pump closer to the tank. I agree with the others, you need the cold air intake plumbed inside too. It's easier to heat the room air vs outside air. You could also pull in the exhaust fumes since they are close, the way it is now..
@TheArtisticGardener777
@TheArtisticGardener777 Жыл бұрын
You’ve got the exhaust pumping out carbon monoxide in the same space as the cold air intake thus pumping it into the heated space. Seems extremely risky not to mention inefficient. I believe the unit is designed to be placed inside the heated space while the exhaust is piped to the outside.
@nitrosrt4
@nitrosrt4 Жыл бұрын
yes, this right here, put the whole thing inside it will be much more effecient, might even point a fan at the whole thing too it gets hot when its on for a while and heating already warm air is easier than always cold air, just run the burner exhaust outside.
@dr650dude
@dr650dude Жыл бұрын
exactly...
@mikeakerstrom1667
@mikeakerstrom1667 Жыл бұрын
The intake and exhaust both go outside, as they should. The heated air is drawn from inside and is completely separate from intake & exhaust
@capncol
@capncol Жыл бұрын
@@mikeakerstrom1667 the air intake is at the left hand end of the unit, so it is possible to draw exhaust fumes in to the air intake
@capncol
@capncol Жыл бұрын
@@mikeakerstrom1667 the air intake is at the left hand end of the unit, so it is possible to draw exhaust fumes in to the air intake
@cptcosmo
@cptcosmo Жыл бұрын
I'm using one of these heaters to heat my 600 square foot condo. I run the exhaust pipe out a window, seal the gaps (I use fireproof rockwool batt to surround the exhaust pipe). Last winter I used about 5 gallons US #2 Diesel per week to heat my home... far less expensive than heating with electric heat, which used to be my only source of heat. One thing I have noticed, these little heaters tend to coke up the combustion chamber if run at the low settings for long periods.
@alexlee9394
@alexlee9394 Жыл бұрын
I concur, have your air intake coming from inside your garage. Also make sure your combustion air intake is well away from the exhaust pipe and use the muffler, have the exhaust sloping downwards to allow any condensation to come out. The other thing is the fuel pump runs best at 35degrees. Where did you get those rubber connectors for your white fuel line? That leak at the fuel line going into the heater should be tight as well as all others or you will eventually run into an E8 error.
@llordjacksonbuzzthedog.4845
@llordjacksonbuzzthedog.4845 Жыл бұрын
Thanks for the tips! I'm addressing all the points 👍
@DirectCurrent4u
@DirectCurrent4u Жыл бұрын
I think the 50 ton Press to bend a sheet metal bracket was the fatal mistake! But it was very entertaining. ⚡👍
@paullynch1938
@paullynch1938 Жыл бұрын
Pisser mate , I thought that 😂🤣
@jamesturner2126
@jamesturner2126 Жыл бұрын
I was sweeping up wood dust. My diesel heater sucked up the dusty air, then it was to hard to burn, it flamed out. I completely carefully disassembled it, cleaned it with acetone, heated right up. Burning 50% diesel, 25% motor oil, 25% gasoline.
@chrismutlow1
@chrismutlow1 Жыл бұрын
Possibly the funniest video ever. I got to get a press to bend my 2.5 mm brackets. I wonder how you were goina do it lol. I always use a hammer and a block of wood. Funny as
@oojimmyflip
@oojimmyflip Жыл бұрын
I hope youve clamped the exhaust onto the exhsust port with some exhsust paste and routed the exhaust outside, if not run a carbon monoxide alarm in the room. For your own saftey and those around you.
@wilwert1746
@wilwert1746 Жыл бұрын
Do both,safely is paramount.
@CraigOlove
@CraigOlove Жыл бұрын
It has been my experience that the pump mounted at a 45* will burn up pumps, I burned up 3 pumps that way. I now mount them at 90* like you had yours only right side up. My heaters run for months at a time here in western Pennsylvania. You can tell when your pump is starting to go bad, It will start speeding up and then slow down it gets quite bothersome . I can't sleep listening to it speed up slow down. I like mine nice and steady. I think they tell you to mount them at 45* to sell more pumps. They are made of not the best steel. Unlike my Webasto's the pumps work any way you want, They are made really well and are expensive I have some from the 90's that are still ticking away. Cheers..
@donalbershardt9290
@donalbershardt9290 Жыл бұрын
WHY not use, a 12v Remote Pump with a Regulator.. DONE Problem Solved 👍✌️
@solayluna
@solayluna Жыл бұрын
The pump is lubricated by the fuel by providing the angle it ensures fuel from the start eliminating pumping dry...
@zenzen9131
@zenzen9131 Жыл бұрын
Personally I would move the unit inside the heated area with just the exhaust pipe coming through the wall to the outside. This would then have warmer air coming into unit and not freezing cold air from outside making it more efficient.
@redauwg911
@redauwg911 Жыл бұрын
yeah exactly it's all hooked up wrong. This is the correct way- You tube John McK 47
@davidfletcher1156
@davidfletcher1156 Жыл бұрын
But what if the exhaust leaks in the property 🤔
@zenzen9131
@zenzen9131 Жыл бұрын
@@davidfletcher1156 very good point. I'd be running a CO detector closeby
@redauwg911
@redauwg911 Жыл бұрын
@@davidfletcher1156 Then you did not install properly.
@davidfletcher1156
@davidfletcher1156 Жыл бұрын
@redauwg911 please explain why as part of the exhaust will always be in the property and exhaust can deteriate over time so its clearly a risk
@mntn2hi333
@mntn2hi333 Жыл бұрын
The big mistake was watching this video of you trying to flatten the bracket.
@jamesturner2126
@jamesturner2126 Жыл бұрын
The trick to running it on other than diesel is cleanliness and heat. Strip it down, clean it completely, especially around the burn chamber and glow plug. Once it lites, you have to keep it on high so the combustion fan can keep it hot so even motor oil will burn.
@wilwert1746
@wilwert1746 Жыл бұрын
Seems thinning down any heavy oils with waste diesel fuel would be wise though, and of course proper filtering
@Lee-70ish
@Lee-70ish Жыл бұрын
Thanks for the info. From what I gather these are great in RVs and vans but not effective in work shops or garages as they cant heat large areas . Its a shame as i have a double garage/workshop that I'd like to use in the winter, but i think I'd need a proper diesel space heater that pumps out at least 15- 20 kw
@AnnaVannieuwenhuyse
@AnnaVannieuwenhuyse Жыл бұрын
a heat pump could do you good there! Heating in the winter, cooling in the summer.
@samdub
@samdub Жыл бұрын
You’d be surprised you know. Obviously if the garage has openings around the door etc it wouldn’t hold heat but these things ticking over for a few hours can heat up or at the very least take the chill off quite a large area! Mines currently outside my house (which I’m thinking about changing to inside) and it’ll keep my whole downstairs at around 19 without having to boost the heating all the time! (Older house with fuck all insulation)
@svenlarsen4876
@svenlarsen4876 10 ай бұрын
Mine heat's a 3bed semi det house on lowest heat setting
@electroshed
@electroshed Жыл бұрын
Definitely connect up a return air vent from the room to the unit, as, at the moment, you're heating 100% outside air at say zero degrees, you'll only get the max temp rise out of the unit say 15 degrees, the room will never reach a cosy 20 let's say. You want it to reheat the air that's already been warmed from the room for best effect :)
@Yii00T
@Yii00T Жыл бұрын
Will also stop sucking in exhaust gasses as well then.
@robertberin4872
@robertberin4872 Жыл бұрын
what size hose did u use for the inlet?
@electroshed
@electroshed Жыл бұрын
@@robertberin4872 ideally a little larger than the outlet hose, larger diameter hoses = slower moving air = lower resistance and in some cases lower noise
@Dieseldog1
@Dieseldog1 Жыл бұрын
freezing cold intake outside......re do so you recirculate the warmed room air and take out the risk of exhaust gas in the room, insulate intake and output, the heater is designed to be inside the area being heated...
@ItsAllJustBollox
@ItsAllJustBollox Жыл бұрын
Watching you using a press on a tiny bracket you could easily bend by hand was hilarious. 😂
@llordjacksonbuzzthedog.4845
@llordjacksonbuzzthedog.4845 Жыл бұрын
Glad you enjoyed it,precion bending with controlled pressure 😉🤣🤣🤣
@johnmorrison9072
@johnmorrison9072 Жыл бұрын
Max 45 degrees down to about 30 degrees is the sweet spot 👍
@randombanditdad3754
@randombanditdad3754 Жыл бұрын
You made that easy bracket bending into right long job lol
@bigoldgrizzly
@bigoldgrizzly Жыл бұрын
that could forever change the saying "using a sledge hammer to break a nut" !
@TheBioniXman
@TheBioniXman Жыл бұрын
Interesting video, good job that it is on youtube though, we can fast forward the 3 minutes of flattening a bit of metal!
@pauldowninguk
@pauldowninguk Жыл бұрын
Hi mate. Not having a go, but you need to switch it off (for your safety) and maybe watch some videos on KZbin first. I'm new to this myself, but your install isn't safe. The exhaust gases can be sucked into the air heater inlet (then outlet to your room) which will be lethal. It needs routing outside. All the exhaust and fuel lines need Jubilee/circlips. The fuel line needs a filter before the pump. Try to run the unit off a car battery. A trickle charger can keep it topped up. Otherwise a power cut/trip will ruin the heater due to no slow power down. Good luck!
@SpiraSpiraSpira
@SpiraSpiraSpira Жыл бұрын
The air heater inlet doesn’t exhaust air into the room being heated. It’s true with the output and input close together some exhaust products are likely being ingested, and that’s not good for efficiency, but it isn’t a safety issue. This type of heater pulls air, combusts it, and exhausts it in one loop. Then a second air loop pulls air from the room to be heated, runs it through a heat exchanger, and dumps that now-heated air into the room/area to be heated. That’s the main reason why these things are safe to be used (if installed correctly) in truck cabs, etc. There’s 2 loops for air, and never do they touch.
@davidfletcher1156
@davidfletcher1156 Жыл бұрын
@@SpiraSpiraSpira I think he means the exhaust fumes are going into the same room as your clean air intake
@wagmiorngmi
@wagmiorngmi 3 ай бұрын
I just read in comments on another video that the guy is dead now from carbon monoxide poison. RIP
@kigerkarlzeberedi1800
@kigerkarlzeberedi1800 Жыл бұрын
I bought a Chinese diesel heater for the first time about 4 years ago" I've bought 3 since then" they last about a year before the bearings start to squeak from pretty continuous running' a lot of the time on low" thats were my issue tonight was as i was watching the videos' on white smoke my d heater started to spew white smoke' i thought there was a new pope". I haven't ran it hot for months and i figured from my considerable experience that I had some build up that needed to be hot burned and a quick general ⛑ ⛑ maintenance' so i ran it full blast and it musta cooked the chamber" I went outside and straighten the exhaust pipe straight down and went back inside and started the heater it was still blowing white smoke and then what sounded like half a gunshot went off and couple of ounces of Black soot fell onto the ground and the Heater ran perfectly. Sure glad i straightened that exhaust pipe and burned the chamber or i wouldn't be having a merry Burrrrr Christmas. 1995 Thor 32 ft M
@BeFs
@BeFs Жыл бұрын
Thinking about buying one of these any day now, just my luck that you uploaded this video right now :D Thank you
@putbinoot
@putbinoot Жыл бұрын
Should have a fuel filter in the kit to protect the pump.
@jaminthevanuk296
@jaminthevanuk296 Жыл бұрын
Well done for using this kit ....
@A.S.K.1
@A.S.K.1 Жыл бұрын
The combustion air intake and exhaust are outside, as they should be. BUT: The *FRESH* air intake is not far above the exhaust: so it could pull in (CO laden) exhaust gases and send them inside the building. This could be a real *"FATAL"* error... as in it can efficiently, silently, kill you. The FRESH air intake needs to be completely separated from the exhaust... preferably in the same area that is being heated so it can re-warm already warmed air - much more efficient, also. Also you still seem to have a diesel leak..that can contribute to your usage - not to mention if it hits the usually VERY hot exhaust pipe, it could ignite... not something you want to happen, either.
@SchwaAlien
@SchwaAlien Жыл бұрын
You can also calibrate the heaters so that they only use as much fuel as needed to generate the correct amount of heat rather than the default of too much which will make a more dirty exhaust and need to be cleaned more often, and usually the fan’s low speed is too low to move much air, so it’ll have a more useful range when you go to turn it down, once calibrated.
@zaprodk
@zaprodk Жыл бұрын
So how do you calibrate this?
@brandonthatcher7781
@brandonthatcher7781 Жыл бұрын
@@zaprodk Hes got no idea. Just saying something he saw somewhere else..
@danyf3116
@danyf3116 Жыл бұрын
@@zaprodk kzbin.info/www/bejne/iZ6mioSrapioo80
@bradbair1405
@bradbair1405 11 ай бұрын
​@zaprodk you calibrate through the touch screen. You can turn the hertz up and down for fuel flow depending on what type of fuel being used. I believe I've seen 4 to 4.5 hertz for diesel and 3.5 to 4 hertz for kerosene.
@craigchamberlain
@craigchamberlain Жыл бұрын
The fuel pump can be vertical as long as it’s the right way up. In fact it’s better vertical than at 45 degrees as air can get out even easier. The big no-no is to have it horizontal or at a shallower angle than 45 degrees. As others have said already, you’ll get a huge efficiency improvement if you recirculate warm air rather than heating outside air all the time. Keep combustion intake and exhaust outside but have circulation intake and exhaust inside. It’s even better if you have the whole unit inside with the combustion exhaust and intake going outside because you also capture the radiated heat from the heater, but it would be noisier.
@keirwilliamson1274
@keirwilliamson1274 16 күн бұрын
just bought a sunster all in one and pump is installed horizontaly
@pixels303at-odysee9
@pixels303at-odysee9 Жыл бұрын
I wanted to install one of these bad boys for my bunk in my RV. There is no heating in that area for some strange reason, so even if I turn on the heat, it is chilly sleeping in the bunk. Diesel is easier to obtain than propane and does throw more heat per volume. You could easily have a small slip tank filled up (100+ liters) and it should last a long time between fills.
@wilwert1746
@wilwert1746 Жыл бұрын
I'm planning on tapping a boat fuel tank for run time and safer fueling (heater inside,tank outside)
@pixels303at-odysee9
@pixels303at-odysee9 Жыл бұрын
@@wilwert1746 those boat tanks are nice. You can also use plastic tanks used for farm grain belts or augers.
@Bryan-Hensley
@Bryan-Hensley Жыл бұрын
These things will heat your entire RV. I'll probably be overkill for a bunk
@jbigroup5070
@jbigroup5070 Жыл бұрын
Also i would take the air from the room to pass through the heater and back in, if you are always taking in very cold air from outside you will be losing energy. By taking the warm air from the room and passing it again through the heater it will heat the room quicker. It would be like switching on the recirculation switch for the car vents with the AC on, the car gets much colder as it takes the cold air from the interior and passes it back through the AC then back in again.
@4x4smile
@4x4smile Жыл бұрын
Warning Carbon monoxide poisoning from exhaust and inlet to blower being in same area. Duct the intake side of the heater into the room to stop, it will also be way more efficent. At the moment you are blowing cold exhaust contaminated air into the room.
@charleswillis9956
@charleswillis9956 Жыл бұрын
I would guess you don't have a vice and rubber hammer .
@michaelmccotter4293
@michaelmccotter4293 9 ай бұрын
I'd also consider moving the pump away from the hot exhaust. Anchorage, Alaska
@julioposada7752
@julioposada7752 Жыл бұрын
Watching you use a hydraulic press to flatten that bracket gave me permanent anxiety 😂😂😂.
@llordjacksonbuzzthedog.4845
@llordjacksonbuzzthedog.4845 Жыл бұрын
Controlled pressure 😉 lol couldn't find my hammer 🤣 glad you enjoyed the video.
@66reeves
@66reeves Жыл бұрын
Mission impossible theme would have set the mood for the job
@darrenwilson3905
@darrenwilson3905 Жыл бұрын
Interesting that you think installing the pump upside down is a fatal error, yet you've installed the exhaust without a clamp and are drawing the air for heating from the same space. Carbon Monoxide poisoning can be fatal too.
@cfcyayaya
@cfcyayaya Жыл бұрын
Yes, this is a more serious mistake than the fuel pump installed up side down. We spotted. When the heater starts, the workshop must be filled with diesel fume. Even at steady state, the amount of carbon monoxide is not zero. The heater was designed to be used inside a caravan. The separation of breathing air and burning air must mimic that of a caravan.
@dr_jaymz
@dr_jaymz Жыл бұрын
I worry about these exhausts being too close to the cold air inlet. It will actively suck combustion products into it and into the workshop. When you pipe workshop air back out to the air intake that will help keep the two circuits isolated.
@SpiraSpiraSpira
@SpiraSpiraSpira Жыл бұрын
This isn’t how this type of heater works. This heater has 2 inputs for air. The first one is the input that gets combusted, then exhausted. These are generally both from outside. A second input takes air from inside the area being heated, runs that air over a heat exchanger and outputs it in the room to be heated. That’s what the fan is doing/why it needs electricity. So even if the input air that you’re talking about takes a little bit of combustion products, it will be exhausted right back outside without anything entering the room if he installed it correctly.
@wilwert1746
@wilwert1746 Жыл бұрын
Only difficult part is control setup. Instructions are junk.
@wilwert1746
@wilwert1746 Жыл бұрын
I haven't found any control panel wiring extenders, did you cut and splice?.I'm cautious to try it yet.
@Marti-dw9xt
@Marti-dw9xt 29 күн бұрын
That's a 2 minute Tutorial max ! !!!! I am now on the Fecking phone to the SAMARITANS
@realeyesrealizereallies6828
@realeyesrealizereallies6828 Жыл бұрын
They use alot of fuel if you leave them on high or even medium, no matter if the pump is upside down or not..These are great for small insulated spaces when you can run them for half an hour and shut them off for an hour or so, or when the power goes out..A wood burner is best, then a mini split, for larger areas..
@dougjones4538
@dougjones4538 Жыл бұрын
So, how do you know which end of the pump is the inlet and which is the outlet? I have my pump fresh out of the box from Vevor, and there's no marking indicating direction.
@PainterD54
@PainterD54 10 ай бұрын
You should have a cold air return from inside that room to go thru the unit and then back into the room with re-heated air. You are actually heating cold air and pumping it into a room. You need to make a continuous loop to properly heat a room.
@fredfred2363
@fredfred2363 Жыл бұрын
Here's more info on fuels I've tried in the UK spec Vevo 5kW unit, with stock settings (with the controller-new type, late 2022, without the antenna signal indicator): Best fuel, most heat, Kerosene=heating oil=jetA1=paraffin Diesel, red or standard next best Brake fluid, DOT3 diluted with 10% petrol next best Old dirty engine oil diluted 20% with unleaded petrol next best Transmission fluid/old gearbox oil diluted with 10% petrol next (but smelly) Old gunwash thinners with 10% old engine oil to give it some lube properties not very good Old petrol with 10% old engine oil, also not very good. Acetone, brake and clutch cleaner (trichloroethylene- don't breath the smoke at all) or alcohol/meths don't really work at all. With all of the hydrocarbons, it is pretty obvious that there is way too much air running through the combustion chamber, because the exhaust pipe gets really hot (wasted heat). The combustion gas is being pushed straight out of the heat exchanger. If you choke the combustion air inlet a little, while still maintaining a lean and clean burn (at max fan speed), the exhaust temp drops while the heat exchanger actually gets a lot hotter. More time for the hot combustion gases to transfer the heat into the heat sink, as the burning gas is moving slower. Oh and throw away the little fuel filter they supply, as it doesn't filter anything! Get a proper fuel filter... If anyone knows how to crack advanced settings on the new controller unit (without antenna signal indicator), please post! 👍🏻😀🇬🇧
@wilwert1746
@wilwert1746 Жыл бұрын
Speaking of which, what,exactly is the purpose of the connectivity, I can't find an app for this and instructions are sparse with controller settings
@garycote6129
@garycote6129 Жыл бұрын
Allot of faffing about to straighten that bracket out. Bench vice, BFH, 10 seconds… sorted ha, ha, ha.
@davida369
@davida369 Жыл бұрын
An update on the consumption and the power level yu are running it at would be kool, ta
@prabhgunnsingh7357
@prabhgunnsingh7357 Жыл бұрын
The fuel pump is recommended bet.30 to 45degree Angle not upside down.thks
@kevinszulinszky6245
@kevinszulinszky6245 7 ай бұрын
I believe your fuel is supposed to be mounted above the heater as well as the 30-45 degree tilt of pump...mayhaps that could also be the cause?
@Lordlindef
@Lordlindef Жыл бұрын
What Hz settings you use low and topp ??? 5 liter over night ??? Omg i use 1/3 of that if not less
@kennethyanni3852
@kennethyanni3852 Жыл бұрын
Better off running it inside so the air intake is using the inside air ,,will warm faster and be more efficient and of course vent the exhaust outside 😊
@jimgresham5529
@jimgresham5529 6 ай бұрын
Any problems with heat going through the wall ?
@davecooper3238
@davecooper3238 Жыл бұрын
What do mortgage holders, insurance companies & freehold owners think about these heaters ? Could fitting one lead to legal troubles.
@rico334
@rico334 Жыл бұрын
Good video but you could have shaved 4 minutes off it by using a hammer instead of that press...... 😂😂
@PremierTinman
@PremierTinman Жыл бұрын
Hi my new heater has came with the pump horizontally and in same direction as the mistake in the video so mounted it a 45 degree angled but there is a flow arrow pointing towards the wiring is it wrong any idears .cheers
@llordjacksonbuzzthedog.4845
@llordjacksonbuzzthedog.4845 Жыл бұрын
Hi John thanks for the comment. As far as I understand the arrow is the direction of flow and should point 👉 towards the wire connection. However different comments on KZbin land say the angle of the pump doesn't matter to much ...30/45/90/vertical etc. Mine is about 40-45 degrees ish ....and it's been working fine every day for over 2 months now .cheers.
@paulbeddows6014
@paulbeddows6014 Жыл бұрын
That's quiet a height for the pump to draw fuel from be interesting to see if the pump lasts. In the boxed versions there is only a matter of inches for the fuel to be drawn to the pump then the pump drains down hill as well. So you have two extra strains on the pump.
@peterlumper5376
@peterlumper5376 Жыл бұрын
think I would have just stood on the right angle bracket tbh 😄
@paullynch1938
@paullynch1938 Жыл бұрын
No mate you need a 50 ton press, what a pisser
@jlr3636
@jlr3636 Ай бұрын
Your next video could be "how to use a hydrolic press"
@ANDY-we7mr
@ANDY-we7mr Жыл бұрын
Thanks, for sharing that but iam getting a all in one with the led remote and with the built-in tank so much easier to move about
@VANFLIPPINGTASTIC
@VANFLIPPINGTASTIC Жыл бұрын
ive tested this type of heater in a video and flat out it used 1 litre every 2.5 hours ..
@shootingsportstransparency7461
@shootingsportstransparency7461 Жыл бұрын
I think you bought an illegal UK copy of a genuine original Chinese heater
@carter33361
@carter33361 Жыл бұрын
Just to add to air intake. You need one otherwise you will be drawing in exhaust fumes.
@PeterJavea
@PeterJavea Жыл бұрын
The fuel usage is mathematical Each impulse of the pump moves 0.02ml of fuel. No more. No less. Mine has 5 settings "H1,2,3,4,5. Etc Here's the maths Fuel usage H1 2.0/sec = 120/min = 144 ml/h H2 2.6/sec = 156/min = 187 ml/h H3 3.4/sec = 204/min = 245 ml/h H4 4.0/sec = 240/min = 288 ml/h H5 5.0/sec = 300/min = 360 ml/h That's what my "8kw all in one unit", uses. It was designed in the 1930's for caravans, trucker cabs at night, boats, my garden cabin, etc... Not really for homes, although many do warm a simple room really nicely with it. (Not the whole house, as some think) It's 5kw. No more... I am over the moon about mine by its efficiency, simplicity and serviceability. I hope this helps
@thinkfirst6431
@thinkfirst6431 Жыл бұрын
I see that you have a church pew in front of the hardness tester. Do you pray before using the hardness tester hoping that the hardness comes out OK?
@llordjacksonbuzzthedog.4845
@llordjacksonbuzzthedog.4845 Жыл бұрын
😆 🤣 😂 😹 daily worship, thanks for watching 👀 your comment made me laugh this morning. 😄
@bjrnhenrymikkelsen706
@bjrnhenrymikkelsen706 Жыл бұрын
At full blast a 5kw heater will use about 0.5 l/hr
@VANFLIPPINGTASTIC
@VANFLIPPINGTASTIC Жыл бұрын
spot on mate i did a test on this in my video
@jabbalechat7910
@jabbalechat7910 Жыл бұрын
Try using Alpine mode in the settings, it'll greatly increase the fuel efficiency - see the relevant Vanflippingtastic channel video from two weeks ago...
@gregkelmis2435
@gregkelmis2435 Жыл бұрын
Unit should be inside Paul outside air for combustion and exhaust outside but the unit itself should be inside much more efficient your heating, whatever the outside air temperature is ambient air temperature up to room temperature to put it inside the heat way more fuel consumption depending on the temperature, you can before five times more fuel at sub zero
@Arbe1945
@Arbe1945 10 ай бұрын
Where have you got the exhaust going into. a room or outside?
@kevinbeer6958
@kevinbeer6958 Жыл бұрын
Another error why are you taking cold air from outside? If you recirculate the air from inside it will be possibly 30% more efficient
@pinzgauernorcal
@pinzgauernorcal Жыл бұрын
how was it even working if you had the pump on backwards? doesnt that mean its pumping the wrong way?
@llordjacksonbuzzthedog.4845
@llordjacksonbuzzthedog.4845 Жыл бұрын
Hi the pump flow wes correct it was jut the pump angle was wrong.
@PipeManPeep
@PipeManPeep Жыл бұрын
There was mention of fuel efficiency / consumption intermingled with talk about the pump orientation, but no explanation as to the link between the two. How are they related? Also, when the pump bleeds air, where does it vent it to?
@wilwert1746
@wilwert1746 Жыл бұрын
I see no benefit as to run time tho proper placement could affect other performance.
@itsallfabrication
@itsallfabrication Жыл бұрын
Good save, well done.
@jamesturner2126
@jamesturner2126 Жыл бұрын
The pump suffers from cavitation, diesel leaks out, so air leaks in. Strangely, it'll prime 5 meters across my truck, but it needs a 10cm short tube to the heater, to prevent a build up of bubbles. The faster the pump pumps, the hotter the unit runs. Bigger the area, longer it runs.
@Bryan-Hensley
@Bryan-Hensley Жыл бұрын
Do you realize how much suction you'd have to pull on diesel to cause it to boil? (Cavitation) These plunger pumps have no where near the power to cavitate the fuel. And you'd need a serious restriction in the suction line. It's takes very low pressure to boil kerosene or diesel.
@prabhgunnsingh7357
@prabhgunnsingh7357 Жыл бұрын
Pl try putting Fuel Tank at same height as the heater. The flow of diesel will be easy.May be that improve your heater,as you say it take 5 ltr.diesel in 8 hours. I see a video where guy check the average to be 0.14 ltr./ hour. I buy my heater after checking that video.
@GoldenCroc
@GoldenCroc Жыл бұрын
0.14 l/h isnt at full (5kw) tilt, no way. Maybe at 1.5-2kw output or so.
@DDevianceth
@DDevianceth Жыл бұрын
Isn’t the exhaust also to close to the fuel tube?
@juliogonzo2718
@juliogonzo2718 Жыл бұрын
You can't really get it any further away
@colmanlong1032
@colmanlong1032 Жыл бұрын
Looks a good job.
@vinquinn
@vinquinn Жыл бұрын
Why not recirculate the inside air through the heater instead of taking in cold air from outside?
@rocketman702
@rocketman702 Жыл бұрын
Gravity feed the fuel and take the load off the pump, Don't ever use that press again that way to flatten a pissy little bracket. And recirculate the warm room air back through the intake of the heater..
@citic101
@citic101 Жыл бұрын
are there english desel heaters or even german heater s ?
@normangibson9907
@normangibson9907 Жыл бұрын
Use kerosene mate works aswell and I think burns cleaner and here in Ireland anyway it's half the price of diesel
@garybath6276
@garybath6276 Жыл бұрын
Ya I probably would have used a Hamer to flatten the bracket but I guess when you have all the toys you might as well use them.
@whisthpo
@whisthpo 4 ай бұрын
KZbin at its Best.
@MakeDoAndMend1
@MakeDoAndMend1 Жыл бұрын
Fuel consumption like a car depends on engine size. Diesel heaters can be 2Kw, 3Kw, 5Kw, 8Kw. So consumption can vary. I run my Diesel Heater on paraffin or Kerosene or Domestic heating oil. However prices have gone mad. Cheers from old George and Jane motorhome Adventures.
@oojimmyflip
@oojimmyflip Жыл бұрын
There are no 8 kw diesel heaters time to wake up to reality, its a sales scam.
@fredpepper4773
@fredpepper4773 Жыл бұрын
Could do with a fuel filter on that mate!
@llordjacksonbuzzthedog.4845
@llordjacksonbuzzthedog.4845 Жыл бұрын
Its in the pipe line 👍
@Pawel5837
@Pawel5837 Жыл бұрын
Wires upward. Angle 15° to 30° from the level.
@DroneHDTV
@DroneHDTV Жыл бұрын
I see you have no clamps on pipe connections? if air mixes then you have problems too. My heater works on full power on red for 10 hours cost 350 a day uk pounds full blast
@llordjacksonbuzzthedog.4845
@llordjacksonbuzzthedog.4845 Жыл бұрын
Thanks for the tip
@hughfoley1609
@hughfoley1609 Жыл бұрын
Recirculate the air rather than heating the air from outside the room
@trevorkingsley7002
@trevorkingsley7002 Жыл бұрын
Having the fuel pump upside down is hardly a "fatal" mistake. However, having the combustion exhaust outlet in, what appears to be, an enclosed (dirty) area of your workshop, could well and truly be FATAL! Would you leave your car idling away in that area all day?
@tigerick7291
@tigerick7291 Жыл бұрын
How did it run if the pump was pumping in the wrong direction?
@Bryan-Hensley
@Bryan-Hensley Жыл бұрын
It was pumping the right direction, it was just mounted upside down.
@paulbeddows6014
@paulbeddows6014 9 ай бұрын
Tank and pump should be above the heater not below it the pump only meters the fuel it does not pressurise it. Air intake and exhaust are the only things that need venting to the outside air, hot air intake and outlet stay in the room. If you have the burner air intake inside it causes negative air pressure and removes your heated air and pumps it out side.
@helihead11
@helihead11 Жыл бұрын
If you ever want some advice just make a KZbin video of what your doing. That’s my advice.👍
@orbitalman1
@orbitalman1 Жыл бұрын
The exhaust should be to the out side and do you have a co meter
@thesakcheegii
@thesakcheegii Жыл бұрын
Looks like the heater is inside. Also exhaust is inside. Beware of exhaust carbonoxide!
Vevor Portable Diesel Heater - Don't make this Mistake😖
15:52
Primal Outdoors - Camping and Overlanding
Рет қаралды 134 М.
Change My Mind About Chinese Diesel Heaters!
18:02
Casey 250
Рет қаралды 86 М.
Кто круче, как думаешь?
00:44
МЯТНАЯ ФАНТА
Рет қаралды 6 МЛН
А я думаю что за звук такой знакомый? 😂😂😂
00:15
Денис Кукояка
Рет қаралды 4,7 МЛН
Why no RONALDO?! 🤔⚽️
00:28
Celine Dept
Рет қаралды 86 МЛН
Turn Off the Vacum And Sit Back and Laugh 🤣
00:34
SKITSFUL
Рет қаралды 7 МЛН
CHINESE DIESEL HEATER TIPS FOR INDOOR USE
10:26
Mark Davies
Рет қаралды 57 М.
Diesel Heater Fuel Pump: How to QUIET a Noisy Fuel Pump
9:21
Made to Explore
Рет қаралды 98 М.
how to assemble, prime, and start a Chinese diesel heater for the first time
22:09
Chinese Diesel Heater 1 Year Update Is It Worth The Money
7:53
2000 HOURS LATER! Chinese Diesel Heater
24:55
Mispronounced Adventures
Рет қаралды 506 М.
The Truth About Diesel Heaters - Carbon Monoxide, Formaldehyde & TVOC !
33:35
Lowered Expectations
Рет қаралды 12 М.
Chinese Diesel Heater - Power Supply hack/secret
5:10
Life @ Soap Creek
Рет қаралды 61 М.
Updated Waste Oil Heater Drip Feed Ver.2.2 Detailed January 19, 2018
21:25
My Vevor Chinese Diesel Heater Stopped Working. Can I fix it??
36:32
Alaskan Homesteading
Рет қаралды 46 М.
Кто круче, как думаешь?
00:44
МЯТНАЯ ФАНТА
Рет қаралды 6 МЛН