Chinese diesel heater factory default settings

  Рет қаралды 71,965

Mark Davies

Mark Davies

2 жыл бұрын

ok put it all back to factory default settings and fuel filter but pump still keeps stopping

Пікірлер: 61
@getemoutwildlifecontrolinc1189
@getemoutwildlifecontrolinc1189 2 жыл бұрын
Thank you for this!!! Saved my a lot of time.
@Mark_VWUK
@Mark_VWUK 2 жыл бұрын
Thanks dude! The reset saved my ass 👊
@Restless2010
@Restless2010 Жыл бұрын
Great Video!
@MrMeltedwellies
@MrMeltedwellies Жыл бұрын
Thanks!
@Young937phoenix
@Young937phoenix Жыл бұрын
I'm having a problem with my heater after 4 years of it running fine. I just switched the controler it came with that just had a knob to turn it up and down and a on and off button to the controller you have and now after a year it's blowing alot of smoke and shuts down. I cleaned it out and started it again it worked 1 day and did the same thing again. 😊
@strikemaster1
@strikemaster1 11 ай бұрын
Had almost the same problem, but with heater shutting down completely 10 seconds after diesel pump starting. Rewired from my Aux Battery with heavier gauge wire and no more problems.
@UK-Blue
@UK-Blue Жыл бұрын
I just reconnected mine, not used since early June.... There is no display! Looks totally dead. Fuse OK, electric is getting from battery to the ring connectors that attach to the back of the heater. Is my control panel kaput?
@lionelp1944
@lionelp1944 2 жыл бұрын
I had so much grief after I changed my controller on my 3 kilowatt heater. I tried many things, took it apart many times to clean, finally I had the right minimum and maximum pump and fan speed. now it works beautifully. My real problem had been too rich fuel to air mixture
@kellygb9278
@kellygb9278 Жыл бұрын
What do you do if your ‘Lock’ icon never comes up? After pressing the Settings Button?
@annedunn5859
@annedunn5859 11 ай бұрын
E8 is coming up on mine,is that no fuel in the lines?and hear the clicking noise
@MIck-M
@MIck-M 2 жыл бұрын
I just fixed my friend's one of these which had identical problems with no apparent reason. Where the wire harness exits the heater can become pinched where it bends out causing various wires to lose connection for the odd microsecond here and there. This shuts it down instantly and eventually shows an error for whichever wire\s that were 'pinched'. I simply pushed the harness back a bit into the heater a bit and made the wiring less stressed and all has been well. I discovered it while wiggling all the electrical looms while it was running until I found the dodgey bit.
@MrMeltedwellies
@MrMeltedwellies 2 жыл бұрын
Cheers Mick will defo give that a go and let you know how i get on 👍🍷🍻
@floyd4303
@floyd4303 2 жыл бұрын
I got same thing going on did you manage to fix?
@skrswift
@skrswift 7 ай бұрын
I dont have a padlock available when I long press the settings button even when entering 1688 pw any ideas?
@mickgatz214
@mickgatz214 7 ай бұрын
I really like the "Secret Menu", but I guess it's not really a secret anymore!...... 😂
@MrMeltedwellies
@MrMeltedwellies 7 ай бұрын
Dam was trying to keep that a secret 😁👍
@ianaristotlethompson4186
@ianaristotlethompson4186 Жыл бұрын
Mine was doing the same thing turned out to be the pump sticking. After tapping it a few times on a piece of wood started working OK again. Time will tell.
@CaptainBowman
@CaptainBowman 2 жыл бұрын
Hello Mark! How do l get my forgotten pin or password or bypass pin or can l reset pin to original 1688??
@LihuaWang-ui1qj
@LihuaWang-ui1qj 2 ай бұрын
Hello, I am a manufacturer of parking heaters. Nice to meet you.
@MrMeltedwellies
@MrMeltedwellies 2 ай бұрын
Nice to meet you too
@lionelp1944
@lionelp1944 2 жыл бұрын
Hardly anybody ever mentions if it's a 5-kilowatt or 3 kilowatt on these videos
@securityguardcommand9792
@securityguardcommand9792 Жыл бұрын
Virtually no difference in the controller. The heater is also nearly identical. Main difference is the speed the pump send fuel into the heater.
@StephenPeters
@StephenPeters Жыл бұрын
​​@@securityguardcommand9792 main difference is the amount of fuel per pulse, not the pump speed.
@securityguardcommand9792
@securityguardcommand9792 Жыл бұрын
@@StephenPeters it is the speed. The pulses are measured in hertz. How many pulses per second. Which translates into amount of fuel.
@nadieselgirl
@nadieselgirl 2 жыл бұрын
Might be worth trying a new screen/atomizer and getting a little air out of the fuel line? But yeah, something is telling it to give up. :(
@MrMeltedwellies
@MrMeltedwellies 2 жыл бұрын
Thanks for comment i did have a look inside and took out the atomizer all clean just tried mainboard still no good pump next than wiring loom check
@grahamnielsen4797
@grahamnielsen4797 2 ай бұрын
Put a multimeter on the pump plug to see if you have power
@MrMeltedwellies
@MrMeltedwellies 2 ай бұрын
Cheers graham
@Genghis-Khan121
@Genghis-Khan121 6 ай бұрын
Mine won’t go too default setting I have two heater one it bits because fan broke and I got sick of fixing one thing after another not my brand new one only two weeks cold has also packed in it’s one with blue screen swapped over screen control tried everything it will not prime and whatever I do nothing changes and Bly it will fire up with both screens as I tried both but won’t prime and all I get on both screens is a little clock that turns up on both , so fires up but pump not working but the pumps did work both of them surly both pumps just decided to brake I’m not having it , both are about to end up at the rubbish tip i have run out of patience I’ll never buy another one ever again , even tried swapping the brain boxes on both yet still wont prime I just can’t believe two pumps no longer work when the both did yesterday
@LWFKarma
@LWFKarma 10 ай бұрын
Hi Mark, Got one of these recently. Connected the unit, wired everything up. When started, the controller just flashes and does not turn on the module.
@MrMeltedwellies
@MrMeltedwellies 10 ай бұрын
contact supplier sounds faulty
@brettrob1980
@brettrob1980 Жыл бұрын
My code won't work 1688 used to work is there another reset anywhere
@timevans815
@timevans815 2 жыл бұрын
Hi. Do you (or anyody) know what Hertz means relating to the heater as its a measurement of frequency, frequency of what I wonder?
@BoCoMo
@BoCoMo 2 жыл бұрын
Pump frequency, the higher the number, the more fuel delivered.
@rangeofhills
@rangeofhills 2 жыл бұрын
Simple, its pump pulses of .02 of a spit of fuel per minute
@adycharl
@adycharl Жыл бұрын
1 Hz equals one second so a setting of 3 Hz is 3 pumps per second. The dosing is about .022ml per pulse
@weptbody7613
@weptbody7613 2 жыл бұрын
You have the pump level, it should not be level, it needs to be 33degrees....i had the same problem
@janbrazda6477
@janbrazda6477 2 жыл бұрын
I have same controller and probably same heater but on my controller is in advance setting one more setup sequence. On yours is after "SN-1" follows "Of". On my is .. "SN-1" follows "PS-5" and last is "Of". Is there someone who know what that "PS-5" means?
@miqueflesh9278
@miqueflesh9278 2 жыл бұрын
It's the watts/power for the glow plug.
@mklopfer
@mklopfer 2 жыл бұрын
This is the "selection of the ignition plug power," the manual indicates: 1=35W, 2=40W, 3=45W, 4=80W, 5=85W, 6=90W, with SN-5 is the noted default. The manual also indicates that SN-1 is for 1 magnet on the fan or "different polarity of magnets or one magnet" and SN-2 is for two magnets "with the same polarity"
@davidevich2482
@davidevich2482 Жыл бұрын
Mine will not do anything after pushing button 4 times
@oojimmyflip
@oojimmyflip Жыл бұрын
those are not the default settings for a 2kw heater as Mr Mcluckie showed when he tested his lavanor pro 2kw heater it should be 0.9Hz to 1.0 Hz low and 3.0Hz to 3.1 Hz high, Ive done exactly what you have been doing with my 2kw heater and for changing the fan speed and high setting it produced lots of black smoke and overheated the pump and combustion chamber which hit 137 degrees C. you can read the case temperature on the newer lcd remote controls.it even produced 33 parts per million carbon monoxide from the glow plug breather hole which was dected in my living room. if you dont have a digital read out on your carbon monoxide alarm it will not alarm untiul it reaches 50 parts per million which is the British saftey standard time to leave the area. But 33 parts per milliuon will just kill you more slowley over a longer pewriod of time say 20 hours. the case temperature shouldnt get much hotter than 117 degrees C which redflects on its leaner burn settings than the 5kw model. once I returned to the 2kw default settings of 0.9 low and 3.1 high there have been no issues, this is why you are consuming as much fuel as a 5kw heater you are probably overfueling it wasting unburnt fuel out of the exhaust pipe and overheating the heater, maybe this is even damaging the motherboard if indeed you are running a 2kw heater?
@MrMeltedwellies
@MrMeltedwellies Жыл бұрын
Thanks for all your info very useful and kind
@AboveGroundLevel.
@AboveGroundLevel. Жыл бұрын
Would the RPM that follows the Hertz setting still be the same however? I did think the Hertz seemed rather high for a 2kw unit. Thanks for the information.
@misu377
@misu377 7 ай бұрын
Hi , at the end of setting I press on end now I can’t enter to settings with the password, do you know how to change the password?
@Restless2010
@Restless2010 Жыл бұрын
9009 in another unlock code aswell.
@tonyhayes8369
@tonyhayes8369 4 ай бұрын
u got junk in it i had to clean my pump out
@mikewhyte3739
@mikewhyte3739 Жыл бұрын
Is your pump placed of 15°
@MrMeltedwellies
@MrMeltedwellies Жыл бұрын
yes
@cristian77tm
@cristian77tm Жыл бұрын
i have the same problem
@irenedunne352
@irenedunne352 4 ай бұрын
did a new motherboard fix it
@MrMeltedwellies
@MrMeltedwellies 4 ай бұрын
still to come ordered one but never turned up
@mirceaflr
@mirceaflr 2 жыл бұрын
For 8kv is the same?
@sydpix
@sydpix 4 ай бұрын
I've been searching the world for 8kw settings. If you found them, could you please let me know what the settings are?
@eivindlindefjell5602
@eivindlindefjell5602 8 ай бұрын
Wtf hz settings your use ???? 1.2hz at low. 3.6hz at topp. Fan speed Low 2200 High 4200-4600 Here you have the best settings you can have !!!!! Thos settings you use clogs up burner inside fully !!!! Take it up and clean it whit braik cleaner !!!! Use my settings and get filter down under fuel tank. And hard plast string from filter to burner. You have foult code sens it stopping. Open up and clean and give it diesel at normal like i told you here. You get it burning and saves both fuel and watt. Age dosent matter. Glowplug is fine sens you gat pass the first yellow light!!!! Fuel get air ore cant come true to burner. Thats ur problem. Best of luck. And all thats use hz settings over this gets clogged up. .easy to open and clean. Dont need to take out glowplug. Can take out after you spelt it in 2 parts for cleaning. Alsow can use boiling water to put in and brush it clean. Put together. Sheck nett around glowplug and see not clogs hangs at the nett ore glowplug. But that you see when splitted in 2. It is easy. And only 4 and 4 bolt. You be amazed after done this and see ur getting same heat and lower use of both fuel and watt
@Ryanoutdoors
@Ryanoutdoors 7 ай бұрын
What?
@lukasproksa4777
@lukasproksa4777 Жыл бұрын
Hello eror E06 fix with this factory code
@AMGMANIAC
@AMGMANIAC 8 ай бұрын
E06 is fan motor error
@jamesstafford9067
@jamesstafford9067 Жыл бұрын
Can you please tell me how to switch from Celcius to Fahrenheit? Thanks
@gordonmitchell729
@gordonmitchell729 Жыл бұрын
I have watched a lot of videos and people have said that Celsius is standard. I have not found anyone who has Fahrenheit displayed. I made a little chart that I stuck on my wall with the equal temperature. Please let me know if you do find the Fahrenheit settings.
@michschep7601
@michschep7601 Жыл бұрын
Filter ALWAYS filters from outside to core.... the bowl ALWAYS catches the crud going thru..... NEVER into the center of the filter screen flowing to the bowl
Diesel Heater New Type Controller
15:12
Mic S
Рет қаралды 152 М.
How To use New Black Three Blade Chinese Diesel Heater Controller With Spanner button - Quick Guide
7:06
Van Life Uk A Complete Survivors Guide
Рет қаралды 126 М.
LOVE LETTER - POPPY PLAYTIME CHAPTER 3 | GH'S ANIMATION
00:15
Alat Seru Penolong untuk Mimpi Indah Bayi!
00:31
Let's GLOW! Indonesian
Рет қаралды 15 МЛН
아이스크림으로 체감되는 요즘 물가
00:16
진영민yeongmin
Рет қаралды 10 МЛН
🌊Насколько Глубокий Океан ? #shorts
00:42
How To Make Your Chinese Diesel Heater Quieter In 7 Simple Steps
8:07
Van Life Uk A Complete Survivors Guide
Рет қаралды 12 М.
Chinese Diesel Heater New Controller Q & As
14:47
Mic S
Рет қаралды 107 М.
Chinese Diesel Heater Error 0-8 Fixed!
14:29
VanOnTour
Рет қаралды 76 М.
Camper diesel heater turn up to 8Kw or down to 0.8Hz
11:56
Steviegtr Anything garage
Рет қаралды 4,1 М.
52.Chinese diesel heater, Setup and programming
9:54
Simply Boating
Рет қаралды 42 М.
204. E-08 Error - Chinese Diesel Heater
16:43
Ralph's House
Рет қаралды 8 М.
CHINESE NIGHT HEATER BLOWING COLD AIR | Diesel heater error fixed | 2021
12:24
Simply Campervan Conversions
Рет қаралды 37 М.
Diesel heater plateau mode
9:21
Random Therapy
Рет қаралды 11 М.
[SOLVED] Diesel Heater Won't Start, Blowing White Smoke
10:00
Adam Gilbert
Рет қаралды 150 М.
ИНТЕРЕСНАЯ ИДЕЯ (@kelvin_bryant25 - Instagram)
0:16
В ТРЕНДЕ
Рет қаралды 16 МЛН
Косички из морковки 🥕
0:40
Сан Тан
Рет қаралды 4 МЛН
Меч в камне 🤯
0:26
FATA MORGANA
Рет қаралды 2,9 МЛН
Почему НИКА решила уехать из дома?
0:46
Привет, Я Ника!
Рет қаралды 1,4 МЛН