Design of column footing

  Рет қаралды 833,919

Civil Engineers

Civil Engineers

Күн бұрын

Пікірлер: 398
@dvespursfan8922
@dvespursfan8922 4 жыл бұрын
I keepn on yielding 14,256 kN-m o the formula of Mu. Is there any mistake on the formula?
@avisiekesiezie7630
@avisiekesiezie7630 4 жыл бұрын
8:32 SBC calculation is incorrect. Denominator should be 16 instead of 14.66
@sairamexcellent825
@sairamexcellent825 3 жыл бұрын
Yes one has to consider area provided
@yohannesafeworkmm8366
@yohannesafeworkmm8366 5 жыл бұрын
I appreciate the presentation. Though, there seems to be a mistake in calculating the the Factor Moment. Mu=1720 kN-m and corrected to 17820 kN-m when calculating 'd'. Mu=14256 kN-m in my calculation. Why? Is there a mistake in the formula or a mix-up of units? Pls give correction and explanation, as this is very very important and will satisfy many who have commented the same. You 've not replied so far. Why? I think you should. Many thanks!
@Raghav_R
@Raghav_R 5 жыл бұрын
What about depth sir?
@HTheHeat619
@HTheHeat619 5 жыл бұрын
i was making a master sheet yea and i thought i was a dunce i kept rearranging the formula in excel and was still getting Mu= 14256kn.m also in the calculation of Length of the pad foundation L= 3.83 m - round up to 4m . There were cal errors yes but i do appreciate the design procedure. Much thanks.
@Ask.khan786
@Ask.khan786 4 жыл бұрын
Also need to take factored load Pu in factor moment equation....and factor moment equation is not satisfied with unit of KNm...but it is coming KNm.m i.e kNm2... Actual equation from interaction chart of column is Mu=Pu×fck×bD2,,,where D is overall depth including cover,, First of all it is needed in design whether column is short or long,,,which method is using WSM or LSM...column effective length Le comes in picture(with 4 condition discontinuos/continuous etc) then ratio of Le/500 +B/30 or 20mm for minimum eccentricity Then still lot more if column is designed as long column...10%increase then helical reinforcement,,ties, pitch,,spacing,,dia
@daebo75
@daebo75 4 жыл бұрын
I agree with you, and calculating the depth also has different result not 401mm, could you please verify the calculation. And also Pu (Soil Factor) was not used in you formula.
@arcangelmagbuhat965
@arcangelmagbuhat965 4 жыл бұрын
@@HTheHeat619 So this presentation is merely a procedural only, and it doesn't count on the reality of the design. Everything are assumptions.
@calvoh9715
@calvoh9715 5 жыл бұрын
why did you calculate moment using reaction load from the column? I think you use the soil capacity as the load for the calculation of moment? I think your calculations are wrong and misleading.
@paulmaxwell8851
@paulmaxwell8851 6 жыл бұрын
Very helpful! I am a builder, trying to understand civil engineering better. Without these videos we must guess with our design work and overbuild. That often means going over budget. Thank you from British Columbia, Canada.
@World_of_peace.
@World_of_peace. 4 жыл бұрын
you are right,its 4 times larger than regular footing
@searchsrinagar6087
@searchsrinagar6087 2 жыл бұрын
i have to design warhouse (100'x40') with steel roofing what should be the minimum column size
@abdakabarkat7572
@abdakabarkat7572 4 жыл бұрын
FULL OF MISTAKES
@jainikshah3875
@jainikshah3875 2 жыл бұрын
(Step-3) Factored moment was confusing, especially values of L,B,D i.e. if it is of column or footing.
@justaguy-69
@justaguy-69 24 күн бұрын
THEE most often mistake made is not elevating the column footing with large gravel and stones to ensure a proper depth of concrete UNDER the footer. the pressure of the weight of the structure can puncture the bottom of the footer cement and you end up with a building supported by rebars stuck in the mud. you need to address THEE most common mistakes people make with each area.
@amritlal9101
@amritlal9101 6 жыл бұрын
Good
@yazerarafathpulipillai2045
@yazerarafathpulipillai2045 7 ай бұрын
check out your formula for area calculation 10%(p+p) mean how will be 2200 ? give a proper (....) which is helpful to easy understand, & be clear that what you are saying in size or elements
@vusalguliyev1660
@vusalguliyev1660 6 жыл бұрын
hi sir.How did u get Factor moment 17820 kn*m ? Maybe calculation isn't true
@blazeazurin
@blazeazurin Жыл бұрын
I am entering these formulae and values into excel but I am getting different values. I get 3.83 for footing size, 14,256 for factor moment. And for the depth I am totally lost.
@abdulbasit273
@abdulbasit273 6 жыл бұрын
Factor Moment should 14256 KN M. According to formula and values. You are doing great job, I am learning a lot of thing from your channel. Jazaka Allah
@wayneseymour1
@wayneseymour1 6 жыл бұрын
I got the same thing too, but he never answers comment so no hope of getting a answer.
@wayneseymour1
@wayneseymour1 6 жыл бұрын
he also made a mistake on the area its 3.82 rounded out to 4 because you cant round out 3.28 to 4 but you can with 3.82 at least I think so.
@wayneseymour1
@wayneseymour1 6 жыл бұрын
AGAIN IN THE DEPTH EXAMPLE!!!
@mohdzaib4811
@mohdzaib4811 6 жыл бұрын
Abdul Basit yes this answers is 14256
@josephneequaye7206
@josephneequaye7206 4 жыл бұрын
Nice one, pls wish asking u some question In real design how do u get the " P"
@dmontenegro
@dmontenegro 4 жыл бұрын
I know for my work, we are given a report sheet from a firm that performs load tests. In the report sheets, they include the maximum reaction (P) for typical columns and critical columns. We use those number to design the column size and the column footing.
@MrBulbul25
@MrBulbul25 5 жыл бұрын
14.66 under square root will be 3.82 not 3.28 m2 that is for the Area
@gouravsoni6129
@gouravsoni6129 2 жыл бұрын
Sir what have you written the formula for Mu....1720 KN-m is not coming ..
@mh9251
@mh9251 4 жыл бұрын
The calculation has mistakes. Correct computation will bring 14256. But, the formula itself you have added extra "B". It is (PL square)÷2. Also by using your factor moment formula SI units does not cancel properly. Please rectify and present again. I love your teaching and knowledge you share. Thanks.
@ericfernandes3149
@ericfernandes3149 3 жыл бұрын
Please advice 30cm column and area of house 9meter by 12meter ground plus 2 floor how column
@local8755
@local8755 6 жыл бұрын
factor moment is 14256kn/m
@gaurav-kk1io
@gaurav-kk1io 4 жыл бұрын
14256 kn-m
@mh9251
@mh9251 4 жыл бұрын
14256 is correct computation. But check my other comment the tutor has mistaken in formula itself. He has overwritten extra "B".
@damienfieldhouse
@damienfieldhouse 3 жыл бұрын
Yeah I get 14256kn.m for the Factor Moment and then 1.140m for the Footing Depth
@jamesy9568
@jamesy9568 3 жыл бұрын
Have no idea where you get the formula, which includes0.138
@mohamedalkasser7511
@mohamedalkasser7511 5 жыл бұрын
U hv many simple mistakes, which make others so confused, hope u revised ur videos carefully before publishing
@kelvin3772
@kelvin3772 2 жыл бұрын
Factor moment should be 14256KN.m
@workpermitwpr9429
@workpermitwpr9429 Жыл бұрын
Kindly explain How to come column size Don't miss guide
@vijaybansode8263
@vijaybansode8263 4 жыл бұрын
Sir plz design isolated eccentric footing on property line column
@VijayKumar-tz1kv
@VijayKumar-tz1kv 3 жыл бұрын
Sir please can u explain about isolated R.c.c column footing
@irfangheewale1837
@irfangheewale1837 2 жыл бұрын
Aslamoalaikum samiullah sab I want the measurements scale how measure and the dimainsaion.
@sameer0138
@sameer0138 5 жыл бұрын
You calculated soil reaction q = 225kn/m2, for what? What is the reason for calculating soil reaction?
@narayananjayachandran831
@narayananjayachandran831 6 жыл бұрын
Civilglobal.com is for sale??? what happened to your website?
@KL-ni2vx
@KL-ni2vx 6 жыл бұрын
Calculations of Mu is wrong... 14256 KN. m
@fareslafta3980
@fareslafta3980 3 жыл бұрын
Hi..samei.. l have 200m2 how desing foundation
@randomstudio4973
@randomstudio4973 3 жыл бұрын
you made a very good and important videos..I recommend you continue to do more numerical examples of building design and structure.thanks for sharing!!
@aprichitmehta1473
@aprichitmehta1473 5 жыл бұрын
2000 hai ya 2200
@jamesy9568
@jamesy9568 3 жыл бұрын
got different values by Australian standards and the Mu is not correct
@ExploreOutdoors112
@ExploreOutdoors112 Жыл бұрын
I think u should use pashto Then u will deliever in more Cleared way
@Highlightsgyan
@Highlightsgyan 3 жыл бұрын
Pier cap steel and slab of bridge Ka steel and shuttering kse nikalte h
@GomatiGoswami-YearBArchArchite
@GomatiGoswami-YearBArchArchite 3 жыл бұрын
sir iska next lecture nhi mil raha. could u plz share link of next lecture
@titusnaidoo6406
@titusnaidoo6406 6 жыл бұрын
many parts of this video is wrong. please review before you upload!!!!!!!!!!!!!!!!!!!!!!!!!!!!!11
@nitinsingh-nj2hr
@nitinsingh-nj2hr 5 жыл бұрын
Titus Naidoo right
@ktsarath
@ktsarath 4 жыл бұрын
wrong explanation for factor moment calculation.
@gearstil
@gearstil 3 жыл бұрын
where is the video with the steel calculation for the foot design?
@hafsaabbas2272
@hafsaabbas2272 3 жыл бұрын
plz fully clear the depth of footing... it was not clear
@Rahul48018
@Rahul48018 5 жыл бұрын
What to do in case of biaxial bending?
@fernandodomingojr.7627
@fernandodomingojr.7627 2 жыл бұрын
Its impossible to have a 4 meters square footing!
@mdumer3632
@mdumer3632 2 жыл бұрын
where is part 2of this Video for steel calculation
@banakarsharath
@banakarsharath 6 жыл бұрын
Area is taken wrong
@omarsaber3907
@omarsaber3907 3 жыл бұрын
very impressive, how could i contact you ?
@engr.maisamturi5581
@engr.maisamturi5581 6 жыл бұрын
Sir please also upload the details of the steel for column and footing of the same video (all calculation ). it was really awesome and helpful. thanks
@frsaj7396
@frsaj7396 5 жыл бұрын
if qu is less than s.b.c .then what happen. ples .explain
@staffpaul5201
@staffpaul5201 6 жыл бұрын
Too many incorrect values, proofread please
@staffpaul5201
@staffpaul5201 6 жыл бұрын
am frustrated about the entire video
@briannajconstruction
@briannajconstruction 4 жыл бұрын
how did you say many incorrect value? prove please?
@DarrellFord
@DarrellFord 3 жыл бұрын
Sir, Your website does not work when clicked.
@wayneseymour1
@wayneseymour1 6 жыл бұрын
the sqrt of 14.66 isn't it 3.82 not 3.28
@civilsitedaily7203
@civilsitedaily7203 4 жыл бұрын
You are also so confused.and so fast ,
@AhamedZiyathSulaiman
@AhamedZiyathSulaiman 6 жыл бұрын
Confused of the formula and result for factored Movement.
@charleshartlen3914
@charleshartlen3914 6 жыл бұрын
Also, no one would ever use the full width of the footing for moment resistance because when you look at the slab in Finite Element Analysis the sides of the footing attribute no strength to the moment resistance...look it up if you don't believe me. For the moment resistance you should chop off 15% of the sides, as the depth would contribute 90% more moment strength. You're just tricking yourself with this process.
@Darksecrets64
@Darksecrets64 4 жыл бұрын
Please clarify which is code you are suing
@sampangibalakrishna1309
@sampangibalakrishna1309 4 жыл бұрын
And also explain concrete pedastrial
@mwangalamsala9114
@mwangalamsala9114 4 жыл бұрын
Your website is not working......🤔
@dhombiz316
@dhombiz316 5 жыл бұрын
square root of 14.66 = 3.82 not 3.28.....how can we trust your numbers ...haizzzSoil induced to the soil is 225...your SBC is only 150kN/m2 ...facepalm , haizzz
@mujiburrahmankhan1577
@mujiburrahmankhan1577 6 жыл бұрын
How to calculate the loads coming on a particular column..???
@rr1228
@rr1228 6 жыл бұрын
Structural Analysis bro.
@vasudevareddyguda6421
@vasudevareddyguda6421 6 жыл бұрын
Mujiburrahman Khan 1
@VinayMehta
@VinayMehta 5 жыл бұрын
Design slab and beams.Transfer beam load(Reactions) to columns to calculate load on column.
@donomer7329
@donomer7329 3 жыл бұрын
You can use area method to sum the loads that coming from the slab and beams
@rajnarayandas2607
@rajnarayandas2607 5 жыл бұрын
sir you taken p=2000KN but when you calculate soil reaction you take P=2200 KN can you explain plz
@animalworld3510
@animalworld3510 5 жыл бұрын
u r right bro, it should be soil reaction.
@rakinanda
@rakinanda 2 жыл бұрын
Hi, can anyone answer and solutions for below 👇 question. 1) what are are the effects, If we increase the column size (9"x15") and the footing size (4'x4'). The soil condition( hard strata 4' below ground level ) and storey (G+1) or (G+2). Please answer this question...
@rajaulkhan4934
@rajaulkhan4934 3 жыл бұрын
How the depth will be 401M it is too much 🥴
@chandupriyap5513
@chandupriyap5513 3 жыл бұрын
Sir 10%of above load gives 200 KN
@edwinpragore
@edwinpragore 6 жыл бұрын
Sir what about different size of colum i.e 0.23x0.30,0.30x0.40
@World_of_peace.
@World_of_peace. 4 жыл бұрын
imagine a 4mx4m footing (13'x13') for a 400x 400 column,its far from reality
@heerasuthar8244
@heerasuthar8244 4 жыл бұрын
yes
@dania8969
@dania8969 Жыл бұрын
Thank you very informative
@deaningjyrwa8291
@deaningjyrwa8291 3 жыл бұрын
Why we take 2000 kn applied load?
@sharathgoogly7162
@sharathgoogly7162 4 жыл бұрын
How can we come to know that side only factor movement accours ,is it ower wish
@sharathgoogly7162
@sharathgoogly7162 4 жыл бұрын
Our*
@fazeelahmad1386
@fazeelahmad1386 Жыл бұрын
Very understandable lecture
@how8408
@how8408 3 жыл бұрын
Area of footing ..not coloum
@Ronnyososo
@Ronnyososo 4 жыл бұрын
Kindly RECHECK all your Calculations prior to making and POSTING the Videos! Too many Mathematical ERRORS and disconnects! Notwithstanding, it was indeed edifying to to the structurally uninitiated. Do keep them coming, but peer review before so doing!
@mrfaizal7431
@mrfaizal7431 2 жыл бұрын
How to calculate applied load
@prabakar2603
@prabakar2603 4 жыл бұрын
Shear check and flexure??
@mirdecoinn
@mirdecoinn 5 жыл бұрын
how to calculate pedestal BBS in footing sir please make one video for that
@matomeramoroka8887
@matomeramoroka8887 3 жыл бұрын
Please review the Mu calculation, also considering the units!
@hussain935
@hussain935 3 жыл бұрын
same observation about units
@phyohtetkoko929
@phyohtetkoko929 2 жыл бұрын
Thanks For Teaching Sir
@francookotsi1297
@francookotsi1297 3 жыл бұрын
In the step of required depth am not getting that 401 mm while using my scientific calculator, kindly confirm that.
@dineshkarthigreeneverestnu1429
@dineshkarthigreeneverestnu1429 6 жыл бұрын
4 m =13.12 Feet but footing not that size
@vigneshkumar218
@vigneshkumar218 4 жыл бұрын
calculation are not correct
@civilengineeringpost9744
@civilengineeringpost9744 4 жыл бұрын
Thanks for you show for calculating for columns footing this reference to leaning and for anther want to know 👍👍👍
@syamlalsasivadakkekalayil8713
@syamlalsasivadakkekalayil8713 2 жыл бұрын
thank you sir
@Hello-nl4gw
@Hello-nl4gw 2 жыл бұрын
Sir Pu= P×1.5=2200×1.5 P=2000 ?
@gettupamuk5241
@gettupamuk5241 4 жыл бұрын
Sir,I think your calculation is wrong answer for the final calculation is 1270.49.
@shivamshukla1727
@shivamshukla1727 4 жыл бұрын
All RCC columns should be designed for * 1 point Shear Torsion No eccentricity Minimum Eccentricity ans plz
@hollywoodamazingmovie3173
@hollywoodamazingmovie3173 4 жыл бұрын
Footing 401 mm ki jagah ans 1270 aa rha hai
@leodimalibot9567
@leodimalibot9567 4 жыл бұрын
kindly recheck your calculation for Mu... something wrong on your operation on calculator....
@civilboy4715
@civilboy4715 4 жыл бұрын
many mistakes
@raghavbhatiaraghavbhatia7571
@raghavbhatiaraghavbhatia7571 3 жыл бұрын
सर क्या हम किसी Reactangular column को square footing par bana sakte hai
@relardztv605
@relardztv605 2 жыл бұрын
Good job sir because of your vlog tutorial I got some knowledge from you
@moazzemhossain6574
@moazzemhossain6574 4 жыл бұрын
Plz give part 2 link
@piyaspratimdan6377
@piyaspratimdan6377 10 ай бұрын
Please send more details
@yaswanthsimha7250
@yaswanthsimha7250 4 жыл бұрын
Why we have to increase the above load by 10% ???
@nabamtadar4372
@nabamtadar4372 3 жыл бұрын
U have to consider self wt of footing also which is assume to b 10% of the column load
@poojakhatal9057
@poojakhatal9057 5 жыл бұрын
What is the formula of mu
@vijaybansode8263
@vijaybansode8263 4 жыл бұрын
And with its detailing
@padamjangid3762
@padamjangid3762 4 жыл бұрын
How to get applied load
@teketigovindarao4424
@teketigovindarao4424 6 жыл бұрын
Very good reaching
@toufiqhasanapurboapurbo9332
@toufiqhasanapurboapurbo9332 3 жыл бұрын
d=401mm sir not d=401m
@nallabothulalakshmanna9595
@nallabothulalakshmanna9595 4 жыл бұрын
Sir how to take the load
@ShihabdeentheCyclist
@ShihabdeentheCyclist 6 жыл бұрын
why are indians and pakistani speaking broken English...?
@MrBulbul25
@MrBulbul25 5 жыл бұрын
most of calculations are wrong check before uploading stuff
@arjunvrassistantengineerhe9210
@arjunvrassistantengineerhe9210 4 жыл бұрын
he better go for a mathematical Class
Spongebob ate Patrick 😱 #meme #spongebob #gmod
00:15
Mr. LoLo
Рет қаралды 19 МЛН
Officer Rabbit is so bad. He made Luffy deaf. #funny #supersiblings #comedy
00:18
Funny superhero siblings
Рет қаралды 13 МЛН
ДЕНЬ УЧИТЕЛЯ В ШКОЛЕ
01:00
SIDELNIKOVVV
Рет қаралды 2,5 МЛН
How To Get Married:   #short
00:22
Jin and Hattie
Рет қаралды 24 МЛН
Design of footing | Isolated Square Footing | Limit State Method | IS 456-2000 | RCC Footing Design
51:36
All About Structural Analysis and Design
Рет қаралды 295 М.
How to Find Depth of Foundation for House? - Minimum Depth of Foundation
14:07
COLUMN FOOTING  DETAIL OF 1 STOREY AND 2 STOREY RESIDENTIAL
16:51
LOUIE TORIBIO
Рет қаралды 58 М.
India’s forgotten maths genius
4:28
Brut India
Рет қаралды 146 М.
What is Foundation | Types of Foundation | Types of Footing | Column foundation
6:59
Civiconcepts - Bhushan Mahajan
Рет қаралды 2 МЛН
The Basics of Bridge Design
52:27
Timmons Group
Рет қаралды 67 М.
Spongebob ate Patrick 😱 #meme #spongebob #gmod
00:15
Mr. LoLo
Рет қаралды 19 МЛН