Can I have Span 7.6 meter (25ft) between Two Columns - How to Keep span 7.6 meter b/w 2 Columns?

  Рет қаралды 221,937

Civil Engineers

Civil Engineers

Күн бұрын

Пікірлер: 181
@gowthamram7852
@gowthamram7852 5 жыл бұрын
Only one doubt... Beam width is bigger than column width... Will it be safe to carry load... 700 x 500 - Beam size... 400 x 400 - Column Size... 500 sits on 400... Will column show heavy buckling when 50mm on either sides of the beam projected outwards...
@risingmoon7008
@risingmoon7008 5 жыл бұрын
Please urdu main lecture diya krein g
@houseplaninkannada
@houseplaninkannada 5 жыл бұрын
Right
@tamuzhs3095
@tamuzhs3095 3 жыл бұрын
Thank you sir more doubts are cleared thank you very much sir more useful
@buddha2845
@buddha2845 3 жыл бұрын
Very good question
@pcrsekarsekar6540
@pcrsekarsekar6540 2 жыл бұрын
For 400 x400 column beam size can be restricted to 700 x300 or not
@prabhatkumardangi7354
@prabhatkumardangi7354 2 жыл бұрын
How do you rest the 560 mm width beam on the 400 X 400 mm column which you have calculated?
@markchen8312
@markchen8312 2 жыл бұрын
He's bullshit!!!
@Utkarshkr.
@Utkarshkr. Жыл бұрын
I came here to comment this.. XD
@indrajeetbondar9251
@indrajeetbondar9251 Жыл бұрын
Absolutely
@kenbomkamsiriba1587
@kenbomkamsiriba1587 8 ай бұрын
Indeed
@kenbomkamsiriba1587
@kenbomkamsiriba1587 8 ай бұрын
Means column size also must be changed
@tomusuaquo
@tomusuaquo Жыл бұрын
I have always enjoyed your insightful explanations. This one was really refreshing. Benefiting a lot from it; so please keep it going.
@lansanah.kamara5299
@lansanah.kamara5299 2 жыл бұрын
Thank you for your excellent explanation. I always enjoy your calculations and explanation.
@prmodrwt
@prmodrwt 4 жыл бұрын
For G+2 building, 7.5 x 7.5 m grid system , central columns will have minimum 2200 km reaction.(Live load 3kn,DL 1.5, seismic zone iv) So min.size column 600x600 mm Beam 450x450 will be more than enough....
@kaqntxpcrlgwmwpwios
@kaqntxpcrlgwmwpwios 4 жыл бұрын
this guys make tutorial only for G+1 ...watch his previous videos..dumbb
@accsltd6978
@accsltd6978 3 жыл бұрын
easy explanations yet solid knowledge ! 🙋👌
@Engrferdz525
@Engrferdz525 3 жыл бұрын
Your very good Engr.. Keep it up and more videos.
@ajitsinghmalik4703
@ajitsinghmalik4703 2 жыл бұрын
Gud knowledge sir
@fortuner123
@fortuner123 3 жыл бұрын
Just work through one example as per the regulation. You can talk about variations after. You keep dotting around from this to that which makes it confusing.
@jasminj.5657
@jasminj.5657 3 жыл бұрын
On existing Third floor terrace floor Column size has 450mm x 230mm Total 8 column Total three galas Each gala has, columm to column span is 12'8" x 18' ( note : this dimensions are not measured from the centre to center of the column ) All 10 beams has width 6" and depth 24" We are willing to increase one more slab i.e. fourth floor slab this would be our last slab With same all dimensions as above third floor have except beams. Beams would have width 9" and depth 12" on fourth floor So would it work out ????? Can this transfer load properly Waiting for your response
@Roadunknown2025
@Roadunknown2025 Жыл бұрын
What size bars+amount use in column? What size bars+amount use in beam? Can the width(400) of beam be the same size as column(400x400)
@rohitjamadar3706
@rohitjamadar3706 5 жыл бұрын
Plz reduce the light 💡 on the board
@C_Pratical
@C_Pratical 4 жыл бұрын
How the beam of size 560x760 is land on the size of column of 400X400 .
@ahteshamilyas3016
@ahteshamilyas3016 3 жыл бұрын
Exactly
@hmingthanmawiachhakchhuakh5254
@hmingthanmawiachhakchhuakh5254 3 жыл бұрын
what will be tha slab design for lets say L= 25 ft and B= 20 ft... the area is too large will the slab bar hold it or we need support beam
@sooner5484
@sooner5484 2 жыл бұрын
Thank you. Great video. Cheers.
@akeemfrancis6794
@akeemfrancis6794 4 жыл бұрын
Thanks for your work sir. What would be the foundation column and plinth beam design for garage with a master suite above using these beams as floor beams?
@danaal-barzanjy6730
@danaal-barzanjy6730 4 жыл бұрын
i designed a hall for confrance . distance bitween the tow coulum is 12m . and the beam bitween them is 78cm . is this safe
@kondeanderson9380
@kondeanderson9380 3 жыл бұрын
In my case I have a span of 9m between rc columns which size of beam should I use
@VAIBHAVSPAL
@VAIBHAVSPAL 4 жыл бұрын
Very Nice Explaination Sir
@AK_1947.....
@AK_1947..... 9 ай бұрын
Can i use 10 inch width & 18 inch depth of a beam for a 24 ft gap b/w 2 columns ?
@kalpeshpatil1250
@kalpeshpatil1250 5 жыл бұрын
It doesn't mention any load , if the load case will consider what Will be changes in design after considering the load case ???
@mian6275
@mian6275 4 жыл бұрын
25 ft is not a Critical case.. It's just simple to design .. try 35' at least
@بنمفازي
@بنمفازي 3 жыл бұрын
35 feet ???
@hugovivas1265
@hugovivas1265 2 жыл бұрын
That formula is for wood beams???
@mahaboobsubhani6758
@mahaboobsubhani6758 3 жыл бұрын
How u chosen reinforcement as 20 mm......exactly
@zakrians1
@zakrians1 3 жыл бұрын
Are you providing the desig services... I need structure designing of my house.
@arsl4256
@arsl4256 2 жыл бұрын
Sir plz tell us how we can know which size of bar use in beam or column and also formula for it to calculate the size of bar for different kind of spans
@louismeoto2126
@louismeoto2126 2 жыл бұрын
Good day sir.please must the column be square.
@umeshthapamagar2503
@umeshthapamagar2503 3 жыл бұрын
Good sir
@AA-pf6ed
@AA-pf6ed 3 жыл бұрын
What details of reinforcement beam in this example
@imtayaz786
@imtayaz786 2 жыл бұрын
How to reduce size of column on g+1 when slab has been cast
@osmanyussuf7069
@osmanyussuf7069 2 жыл бұрын
Excellent thanks
@mccletus5686
@mccletus5686 4 жыл бұрын
Nice done
@carloaprecio6270
@carloaprecio6270 4 жыл бұрын
hi and thanks for sharing your thoughts, nonetheless, are those sizes indicated in your video applied for 2-3 storeys high structure?
@roshnichingakham8539
@roshnichingakham8539 Жыл бұрын
Plz explain for G+1 storey 18ft column and grade beam
@nabumdavid
@nabumdavid 4 жыл бұрын
Can I provide a column distance of 6mtr for a column size of 250x300mm and also what should be it's beam size and its RCC details. Suggest pls.
@duxerick7653
@duxerick7653 2 жыл бұрын
I didn't understand well can you please just start from the beginning or with the formula?
@mohamedabu8754
@mohamedabu8754 2 жыл бұрын
which one i take 760 x 560 OR 400 x 400
@pankajnegi2336
@pankajnegi2336 3 жыл бұрын
Kindly put design of 9.40mtr Spain for slab beam as well as how to fing steel in beam col and slab kindly explain with clearity I mean 4% area of col we how much steel we can used in col.
@isaacamoah-baiden5380
@isaacamoah-baiden5380 2 жыл бұрын
Does the beam depth include the thickness of floor slab...which is 6inches or 150mm.?
@tharangarukmal2803
@tharangarukmal2803 4 жыл бұрын
there is not mentioned about concrete grade
@foodmates1994
@foodmates1994 3 жыл бұрын
Sir can i take 19 feet span with column size 9/15 with16mm 6 bars rectangler shape it is safe or not plz reply only single floor.
@antereatiira1175
@antereatiira1175 Жыл бұрын
hollow sir if the building length 31m width 8m, what types of footing we use and how depth is the footing, and what standard column span?
@khhasib9232
@khhasib9232 6 ай бұрын
How is it possible..Beam's breadth is Larger than column Breadth??
@amitbhatt006
@amitbhatt006 4 жыл бұрын
My column is 9/14 with 16mm bar 3 layer can I take 25ft span beam on this column and pls suggest about steal bar mm for beam
@nazmulkarim6530
@nazmulkarim6530 4 жыл бұрын
Can i take the diatance Between to column 22 ft with 10*12 inches size?
@babuneelam1
@babuneelam1 3 жыл бұрын
Sir How you arrived the column size as 400×400 and steel as dia 20
@silentwatcher1455
@silentwatcher1455 5 жыл бұрын
Interesting discussion. The loading consideration on that beam design was not clear.
@mohanakrishnan1150
@mohanakrishnan1150 3 жыл бұрын
Yes this is the correct way 👍
@majidshah3078
@majidshah3078 4 жыл бұрын
Dear kindly tell the height of ceiling, because trends ate are shifting , what if i want the ceiling height to be 25 feet, can the same formulae be used there as well ? thanks
@momohturay820
@momohturay820 3 жыл бұрын
What should be the depth and width between two column of 25 feet
@govindanchelliah8450
@govindanchelliah8450 3 жыл бұрын
Please explain from footing to top roofing ,
@obareziobinnag-wood9112
@obareziobinnag-wood9112 3 жыл бұрын
Please, in G+1, what about using 4x16mm bar, in a col. size of 225x225mm between a span of 6200mm and dept of beam 450mm with bar 5x16mm. Can it carry?
@fittamizha925
@fittamizha925 4 жыл бұрын
How 560mm wide beam rest on 400mm wide column???😕
@sarabibishaikh7204
@sarabibishaikh7204 5 жыл бұрын
(1) in ground coloum size 9 by 15, there is 6 no of bar 12 mm bar on corner and middle 10 mm bar, in first floor I want to put more steel, like all 6 no of bar 12 mm, can I do it,. (2) we have 35 feet span of two columns, what beam should be design , please answer immediately
@raqeebkhizer7336
@raqeebkhizer7336 4 жыл бұрын
Atleast beam depth should be 2 ft
@shanmugambr9633
@shanmugambr9633 4 жыл бұрын
Width of beam 560 and width of column 400 how?
@prmodrwt
@prmodrwt 4 жыл бұрын
560x750 beam size 400x400 column size. Hahhhhhh Building will fail due to heavy beam, weak column. KZbin University
@imtayaz786
@imtayaz786 3 жыл бұрын
Yes I too notice this he said wrng
@m.v.b1
@m.v.b1 4 жыл бұрын
Can I take 30 foot span for commercial building
@fahadashraf6577
@fahadashraf6577 2 жыл бұрын
Sir can a conceal beam work in 16ft length between two column of 12 inches of varanda
@fahadashraf6577
@fahadashraf6577 2 жыл бұрын
???
@DINESHMaharjan-pe8mt
@DINESHMaharjan-pe8mt 3 жыл бұрын
Width of beam is bigger than column size. Is it possible?
@JayJay-wv1vx
@JayJay-wv1vx Жыл бұрын
My friend you didn't explain properly how you got 400* 400 for column?
@sarangagoswami5311
@sarangagoswami5311 3 жыл бұрын
Sir my house column size is 10/10 inch and 6 tmt bar ( 4 nos 16 mm and 2 nos 12 mm ) maximum distance 14 feet only for G+G1 provision ... Ring size 8 mm tmt with 6 inch c/c ... Any problem in future please reply sir ...
@vi683a
@vi683a 3 жыл бұрын
Im confused your column is 400 x 400 but your beam is 560 x 760?
@rameshg8439
@rameshg8439 2 жыл бұрын
Thank you sir 👌
@Iftikhar825
@Iftikhar825 3 жыл бұрын
Hello Sir hope your are good and enjoying your life. My question is that can we make col 6x12 inches. Because concrete block width is 6 inches.
@lenins9552
@lenins9552 3 жыл бұрын
Sir 16 feet span ....Which type beam use...
@FrancisKrakani-cj3ox
@FrancisKrakani-cj3ox Жыл бұрын
Please the reflection of the light could not allowed us to see proper on baord
@sunnykumar-bs2ud
@sunnykumar-bs2ud 4 жыл бұрын
Ur column size 400* 400mm & beam size 760*560mm... is it ok??
@DjGuetal
@DjGuetal 4 жыл бұрын
I am waiting on his answer as well.
@VAIBHAVSPAL
@VAIBHAVSPAL 4 жыл бұрын
Beam 12x18 inches with 6 Bars of 20 mm and 2 bars of 16 mm is ok
@VAIBHAVSPAL
@VAIBHAVSPAL 4 жыл бұрын
Column 12x18 with 8 Bars of 20 mm dia is ok
@ahmedlebbefowzer2541
@ahmedlebbefowzer2541 4 жыл бұрын
Thanks So Much, is there any calculation if the store increase? Example if the building 3 store same calculation or footage and column and beam will increase is it, do we have any formula for that
@kingengrad6176
@kingengrad6176 4 жыл бұрын
sir, how to calculate the size of reinforcement bar for this case?
@shijojohn8288
@shijojohn8288 3 жыл бұрын
Good content...keep going 👍
@gangannaar9283
@gangannaar9283 3 жыл бұрын
How many rad should come in beam
@aakifamurtaza1514
@aakifamurtaza1514 4 жыл бұрын
In this size of column and beam what bars size should be use
@nandkumarbahadur2974
@nandkumarbahadur2974 3 жыл бұрын
Is hair line normal sir
@kokkantiseenaiah3851
@kokkantiseenaiah3851 3 жыл бұрын
20×55 senter colam requires
@srilaxmikumari5209
@srilaxmikumari5209 3 жыл бұрын
explain it with feet also ,it would be easy to understand
@teodoradomingo569
@teodoradomingo569 Жыл бұрын
Can this be true for a 3 storey bldg?
@mohammadzian320
@mohammadzian320 4 жыл бұрын
Boss how about if the size is 6meter between 2 column what is the of column and beam?
@richardsisei-os1yu
@richardsisei-os1yu Жыл бұрын
Can this also be applied to span of 4.8m?
@bestofsupar693
@bestofsupar693 8 ай бұрын
How much steel bar
@AA-pf6ed
@AA-pf6ed 2 жыл бұрын
السلام عليكم We have a mosque whose dimensions are 8 * 6 m. What are the dimensions of the columns and beams? Im from Iraq
@md.al-amin2793
@md.al-amin2793 3 жыл бұрын
good
@jong6478
@jong6478 3 жыл бұрын
sir,in this topic,if the size of rcc column is 9x9 inches how many steel bars of 12mm in one column? thank you.
@lawrenceloua7325
@lawrenceloua7325 4 жыл бұрын
Can I have 9.76 Column by 32 ft
@youngindia9046
@youngindia9046 5 жыл бұрын
Is it size of slab beam or plinth beam ????? In reference of colm
@booksourexistence2153
@booksourexistence2153 5 жыл бұрын
Thanks a lot... Sirji
@md.arifurrahman3809
@md.arifurrahman3809 3 жыл бұрын
Sir, please tell us the formula according to the change of column length.
@marksmith2723
@marksmith2723 3 жыл бұрын
Sir, after a foundation of a G+1 story has been cast and it's discovered that footings are needed. How do you Add the footings.
@digitalIndia1947
@digitalIndia1947 3 жыл бұрын
What is the size of column for 15x20 sqft area
@md.rafiqulislamrafiq700
@md.rafiqulislamrafiq700 4 жыл бұрын
Can I use 18' clear span column to column?
@binamdahal8827
@binamdahal8827 5 жыл бұрын
Dear sir, what should be the reinforcement in beam for 25 feet long beam for 3 storied building and is it necessary to provide side face reinforcement in beam..???
@youngindia9046
@youngindia9046 5 жыл бұрын
It depends many more factor such as soil quality , zone of earthquake, loads etc
@binamdahal8827
@binamdahal8827 5 жыл бұрын
@@youngindia9046 Yes I got it...it depends on structural loads and others but generally what is appropriate...range...I have the same case 25 feet spacing between columns. I gave 450x600 beam with 6 through 20 mm dia bars at bottom and 3-20 Th at top with 3-20 as curtailed bar...is it okey...in general sense...??
@Aasifkhan11770
@Aasifkhan11770 5 жыл бұрын
Thanks sir Plz clear about size of column how can we deside the size of column in normal structure
@aamirsheikh8306
@aamirsheikh8306 4 жыл бұрын
How come the dimension of column could be less than the dimension of beam ain't we suppose to provide strong column weak beam
@haniabobakr
@haniabobakr 3 жыл бұрын
THE DISTANCE BETWEEN TWO COLUMNS IS GOVERNED BY BEAM DEPTH. YOU CAN GO FOR A 12 M SPAN OR 16 M SPAN, BUT YOU HAVE TO CONSIDER BEAM DEPTH FOR DEFLECTION. THIS NORMALLY NEEDS A PROFESSIONAL STRUCTURAL ENGINEER AND A SMART CONTRACTOR TO EXECUTE IT. THE COST OF DEEP BEAMS IS HIGH.
@malekabodke1496
@malekabodke1496 4 жыл бұрын
How it is possible column width is 400mm and width of beam is 560mm
@wasimahmed457
@wasimahmed457 4 жыл бұрын
I have 30x45 plot , want to construct G+2 , Standard Column size in my city for the mentioned plot size is 6"wx18"d, Can I calculate Beam Size on the basis of mentioned column size for the distance b/w column i.e 12 ft , 16 ft , max 18 ft. Thanks in Advance
@wasimahmed457
@wasimahmed457 4 жыл бұрын
Not getting it answer
@ganeshkumarkannaiah3395
@ganeshkumarkannaiah3395 4 жыл бұрын
25ft span animation video or site video easy to understand thank you sir
@myk-izhargroupicpl3749
@myk-izhargroupicpl3749 3 жыл бұрын
Assalamualaikum, Sir, thanks for guide line for columns and beam sizes in accordance with the IS 131920 code. Could you please make a video thoroughly, I mean A to Z in a professional way. Suppose, we know the bearing capacity from Geo Tech report and how we can design the building with load of 250 Psf, 200 Psf, 150Psf like that. Although your videos are very helpful but short.
@zabighouri2563
@zabighouri2563 4 жыл бұрын
I can't find formula in IS 13920 code
@abdifatahmohamed2604
@abdifatahmohamed2604 4 жыл бұрын
What is the depth of foundation for 4 storey building?
@ayaan5633
@ayaan5633 3 жыл бұрын
This depend on the geological conditions. Under normal circumstances, 1.5 metre depth, 4 X 4 length and breadth is enough.
@bengaluruengineer8270
@bengaluruengineer8270 4 жыл бұрын
RCC is designed based on the principle of strong column weak beams.
Size of Beam , Size of Column and Spacing between Two Column
13:01
Civil Engineers
Рет қаралды 373 М.
Players vs Pitch 🤯
00:26
LE FOOT EN VIDÉO
Рет қаралды 101 МЛН
This dad wins Halloween! 🎃💀
01:00
Justin Flom
Рет қаралды 64 МЛН
Это было очень близко...
00:10
Аришнев
Рет қаралды 7 МЛН
✅ Column Beam Slab Structure in a big span 8M- Rcc Structure
15:20
NHÀ XANH VIỆT NAM
Рет қаралды 88 М.
How to find Depth and Width of a Beam
4:22
Civil Engineering
Рет қаралды 53 М.
Maximum distance between two columns | Column size and steel details for G, G+1, G+2, G+3 | column
5:21
How to Find Depth of Foundation for House? - Minimum Depth of Foundation
14:07
House construction process step by step
24:09
AF Channel
Рет қаралды 2,1 МЛН
For 19ft Span - Size of Footing , Column and Beam Reinforcement Details
12:33
8 Meter Span of Beam and Column reinforcement Details
8:08
Civil Engineers
Рет қаралды 16 М.
Players vs Pitch 🤯
00:26
LE FOOT EN VIDÉO
Рет қаралды 101 МЛН