CNC Plasma Controllers Built Incorrectly (Volume 1)

  Рет қаралды 1,142

Corvetteguy50

Corvetteguy50

Күн бұрын

Пікірлер: 10
@waynesardullo2482
@waynesardullo2482 Жыл бұрын
after all these years it amazes me on how people put so much trust in some of the youtube videos of DIYers out there. I have several skill sets that allow me to be over Dangerous when it might be something just slightly outside my 100% full understanding. The LAST thing I would do is make a Video to show others what I call Dollar Store Professional Solutions. Thanks for being Here Vince! Its always a pleasure to just follow some of the stuff you post.
@corvetteguy50
@corvetteguy50 Жыл бұрын
Wayne, thank you for your support as always! Vince
@IEraiderfan
@IEraiderfan Жыл бұрын
Vince, thanks for the video damn I feel for this guy in the video all the time and money he has spent is an eye opener Stay safe 👍🏼
@corvetteguy50
@corvetteguy50 Жыл бұрын
Lou, thank you for your support as always. I really appreciate it! Vince
@halfstep67
@halfstep67 Жыл бұрын
I like when someone goes to the trouble to use shielded wire but then fails to ground the shielding. I've seen some on YT build a fairly decent system but then use plastic or wood enclosures. A lot of the YT builders also put the VFD in the same enclosure with all the sensitive electronics. It may never be an issue with their builds, but I don't want to take the chance.
@corvetteguy50
@corvetteguy50 Жыл бұрын
Yea, this is very common along with the VFD being mounted with the electronics, and unfortunately, it's because no research is done from credible sources. Thank you for your support. Vince
@johnross3752
@johnross3752 Жыл бұрын
learning this stuff is like going to collage ......
@corvetteguy50
@corvetteguy50 Жыл бұрын
Its certainly a course's length that's for sure. Thank you, John, for your support as always! Vince
@bsulli
@bsulli 9 ай бұрын
Here's something that'll make you shake your head in disbelief - the meter and fuses in the main switchboard for my house are mounted on MDF. These are tamper proof sealed and have to be signed off by a level two electrician on install so I'm assuming it's compliant (and probably the fire rated type) but it seems an unnecessary risk to me. Anyway - thanks for the videos. I studied this stuff at uni, but have been working in software, so it's a great refresher before making my own plasma cnc.
@corvetteguy50
@corvetteguy50 9 ай бұрын
Thank you for your support. I really appreciate it. I would certainly check with your insurance about the use of MDF in a breaker box as this is not the standard practice for most states. I'm glad the videos help. Thank you, and have a great weekend! Vince
CNC Plasma Controllers Built Incorrectly (Volume 2)
7:57
Corvetteguy50
Рет қаралды 739
CNC Plasma Controllers Built Incorrectly (Volume 18)
21:58
Corvetteguy50
Рет қаралды 630
Counter-Strike 2 - Новый кс. Cтарый я
13:10
Marmok
Рет қаралды 2,8 МЛН
"Идеальное" преступление
0:39
Кик Брейнс
Рет қаралды 1,4 МЛН
«Жат бауыр» телехикаясы І 30 - бөлім | Соңғы бөлім
52:59
Qazaqstan TV / Қазақстан Ұлттық Арнасы
Рет қаралды 340 М.
7900XTX AMD ДЕЛАЕТ ВЕЩЩЩЩЩЩИ
14:32
VIK-off
Рет қаралды 311 М.
Mehmet's New Version 2 Plasma Screenset Is Here For Mach3!!
14:48
6 Horribly Common PCB Design Mistakes
10:40
Predictable Designs
Рет қаралды 230 М.
CNC Plasma Controllers Built Incorrectly (Volume 19)
26:45
Corvetteguy50
Рет қаралды 612
CNC Plasma Misinformation Is All Over..
14:58
Corvetteguy50
Рет қаралды 617
DIY CNC Plasma Cutter for 300$
20:27
Scantron's Garage
Рет қаралды 177 М.
Make high quality PCB's at home
12:44
Lasers and Saws
Рет қаралды 107 М.
Counter-Strike 2 - Новый кс. Cтарый я
13:10
Marmok
Рет қаралды 2,8 МЛН