Bro but vera oru video paarthen but avunga colum middle ahh avunga stirups spacing kammiya kudukka sonnanga but neenga middle than bending moment 0 so spacing athigama ahh kuduthukulanu solluringa
@civilcognitionintamil863410 ай бұрын
Yes bro, correct Column centre la bending moment zero so athanala athumari namba pannalam. Eg. Column Center la (L/4) distance 150mm c/c spacing use pannalam , top and bottom (L/4) la 125mm c/c spacing use pannalam (this spacing are just for assumption)
@jules8063 Жыл бұрын
Hi bro Nanga kattura veetula first floor column, ground floor column size vida chinntha iruku. 1 or 2 inch reduce pannitanga. Is that recommended?
@mohanv4916 Жыл бұрын
Its Not big problem.... Load reduce panirupanga.... Suppose 3rd floor build panina prblm varum.... Only 2 floor no prblm
@mithrannila20182 жыл бұрын
sir en veedu 220squre feet 6 Calume poatangha . 1 Calum 12mm 4 numbers poatangha sariya?
@civilcognitionintamil86342 жыл бұрын
Ground floor mattumna problem ethum illa madam
@sakthilingam643 Жыл бұрын
Super anna
@civilcognitionintamil8634 Жыл бұрын
Thanks bro
@Traveldiaries_hk5cw Жыл бұрын
Column cover should be 40mm which means 1.5” approx
@darshananbu4037 Жыл бұрын
Maximum percentage of steel 4% not 6% as per is456 code. Can't pour concrete properly if provide more steel. Darshan (Structural Engineer)
@civilcognitionintamil8634 Жыл бұрын
Yeah as per is 456 the area of longitudinal reinforcement in column must not be less than 0.8% and must not exceed 6% of column gross area but however in practice, maximum reinforcement of 4% is recommended
@infantmanickaraj23302 жыл бұрын
Bro ithu maathiri beam ku video podunga bro
@civilcognitionintamil86342 жыл бұрын
Kandipa video make panren brother keep supporting
@infantmanickaraj23302 жыл бұрын
Sure bro
@iam_mohans67943 жыл бұрын
Sir, outer to outer 11.5 ft ku 31 ft 1 bhk katrom athuku 9 " by 9 " post pothuma future la maximum 2 floor kattuvom athuku 9" by 9 " post pothuma sir please reply
@civilcognitionintamil86343 жыл бұрын
Sir 9"*9" column oru maadi (g+1) building ku pothum G+2(2 floor) building ku 1'*9" column 10ft distance la kudunga pothum Mukkiyamana vishiyam roof la beam kudunga
@iam_mohans67943 жыл бұрын
@@civilcognitionintamil8634 okay sir Thank you so much sir
@iam_mohans67943 жыл бұрын
@@civilcognitionintamil8634 sir g+2 floor ku 9" by 1' post ku enna size rode podanum
@raghuprasath76312 жыл бұрын
@@civilcognitionintamil8634 thank you sir
@praveenkumar-xw8de Жыл бұрын
9*9 column g+1 ok vaa bro
@ashokdavid1083 жыл бұрын
Column gap athigama vuta top load atgugama irutha danger dhana
@civilcognitionintamil86343 жыл бұрын
G floor ku 15 ft varayu prblm varathu(9"*9") ok ......bt (g+1) ku 15ft ku (9"*9") set agathu...Gap athigama achina column and beam size increase agum bro and also depend on floor no's...vara load ah column beam handle paniku....
@ashokdavid1083 жыл бұрын
@@civilcognitionintamil8634 sila v2la pathuruken athan keten Avanga again center la beam poduvanga Load poruthu nama 1st le beam size maximum panikita nalathu
@civilcognitionintamil86343 жыл бұрын
Ama bro main beam ah strong ah kudutha pothu ....naduvula beam theyvapadathu........