Combi Boiler 2 Heating Zones Volt Free - 24V and Others

  Рет қаралды 22,066

John Ward

John Ward

Күн бұрын

Wiring for a combination boiler with two central heating zones, each zone controlled by its own thermostat.
This shows two methods of switching the boiler using volt free contacts and is intended for boilers that do NOT have a 230V switched input, and use some other voltage such as 24V. 230V switching is covered in the previous episode here: • Combi Boiler with Two ...
The arrangements in this video could be used for 230V switching, but there is very little point in doing so.
Suitable for use with almost any thermostat including Nest, Hive and other smart devices. Also applies to wireless, wired, mains powered and battery thermostats.
► Website - More on this video and many other subjects
Website: www.flameport.com
Page for this video: xo4.uk/?c2V
► Support this channel:
Patreon: / jwflame
PayPal Donations: xo4.uk/?PPP
► Social Media:
Twitter: / jwflame
Facebook: / jwflame
Instagram: / jwflame
► Contact info, sending stuff in: etc.:
xo4.uk/?YTT

Пікірлер: 55
@alanrother8477
@alanrother8477 2 жыл бұрын
Great video. Have just rewired my heating centre with this method and added a hive thermostat. Was a bit confused before but this made it so clear to understand. Thanks John.
@Skeletoncrew46and2
@Skeletoncrew46and2 4 жыл бұрын
Thanks john. As usual an excellent video and made so easy to understand. Very informative!
@mikearthur2586
@mikearthur2586 2 жыл бұрын
Once again. a brilliant breakdown. thanks.
@samwhite6734
@samwhite6734 Жыл бұрын
As usual very clear and precise explanations 👍
@leaturk11
@leaturk11 4 жыл бұрын
Nicely explained.
@mianasifgujar
@mianasifgujar 3 жыл бұрын
Excellent Mr J W
@gurdturd7763
@gurdturd7763 3 жыл бұрын
Brilliant , Thanks John. Can i add a cylinder stat to this wiring by using an extra terminal for zone 3 then connecting cylinder stat to 1 and 4 terminals of hive multi zone/thermostat?
@garethjones6887
@garethjones6887 2 жыл бұрын
Keep these videos coming.. what spec of relays would I need to ask for ? And would I piggy back the low voltage side of the relays into the boiler thanks
@gorillagamerimm396
@gorillagamerimm396 Жыл бұрын
Awesome Thanks
@brotherjohnno
@brotherjohnno Жыл бұрын
Hi John, enjoying your wiring videos. Do you have a video covering the installation of relays on S plan systems. I have a problem where I have a back feed from my UFH zone bringing live to my pump for my other zones. Any information would be greatly appreciated. Thanks
@martinuk1001
@martinuk1001 3 жыл бұрын
Hello John, another great video. Are the relays usually supplied with boilers where non-230v to A & B terminals? Or if not can you suggest one please?
@jwflame
@jwflame 3 жыл бұрын
Relay won't be supplied with the boiler, if one is needed you will have to obtain it yourself. For the diagram in this video, it would need a 230V AC coil and at least one normally open contact.
@Chris-js4yq
@Chris-js4yq 3 жыл бұрын
Hi mate would a and b be the terminals in a baxi for this diagram?
@Itsyaboycameron
@Itsyaboycameron 3 жыл бұрын
Hi John videos are very informative, in this example of a zone to a volt free combi, how could I also add a 240v pump to the wiring for an underfloor heating zone? Thanks
@jwflame
@jwflame 3 жыл бұрын
If it's a single UF zone with only a pump, then the pump connects to the switched output of the thermostat in the same way that the valve motor does. Pump N&E connects to 3&5. For zone 1 in the diagram, pump L connects to 7 For zone 2 in the diagram, pump L connects to 8
@millomweb
@millomweb 4 жыл бұрын
John, guessing, what proportion of UK boilers don't use 230V SL ? I'd be sorely tempted to permanently link A-B in the boiler and have the zone valves just power up the boiler ! My boiler doesn't have a permanent live - so not an issue. I believe many systems in the USA are 24VAC control systems - so zone valve motors are 24V.
@PeteyPeteee
@PeteyPeteee 4 жыл бұрын
Hi John, can you make a video about installing a nest or hive? Also can you include the required components for a minimum configuration that will operate a combination boiler. Thanks for the great videos :)
@jwflame
@jwflame 4 жыл бұрын
Hive & Nest: kzbin.info/www/bejne/qne3YnSAqMeAnNE Combi boiler thermostat: kzbin.info/www/bejne/nn7IpotpaNKHd6c The rest of the heating videos: kzbin.info/aero/PLVsHvs2Suqmr5HtxgbInR4bXmH0kLseWc
@PeteyPeteee
@PeteyPeteee 4 жыл бұрын
John Ward thanks. That is my evening watching sorted 👍🏼
@michaelyounge5743
@michaelyounge5743 3 жыл бұрын
Mike Younge Another informative video. In the drawing is show that Thermostat terminal 3 is linked to wiring Centre 7. In the Tado Thermostat it can be linked directly to the boiler A&B . This would leave the brown zone wire free (7) where would this be linked to operate the zone motor to trigger 9&10?
@jwflame
@jwflame 3 жыл бұрын
Any thermostat with volt free contacts can be linked directly to the boiler, but that is only usable for a single heating zone, where there are no zone valves.
@andyhiggins1144
@andyhiggins1144 11 ай бұрын
Hi John, I’ve come across your videos and have found them extremely helpful. I have just bought a new build property with a dual zone combi boiler and want to install hive but I’m struggling to identify which type of system I have. Could I share a picture of the wiring centre and ask for your help identifying it?
@daleprosser350
@daleprosser350 2 жыл бұрын
Hi, this is a great video for learning! 2 questions if you don’t mind: 1) On the boilers with a 24v input, how is that 24v generated? Does the permanent 240v live to the boiler branch off and get reduced down through the circuit board? 2) Where can you see what I put a particular boiler requires? Thank you!
@JasperJanssen
@JasperJanssen 2 жыл бұрын
In this boiler’s case, one of the two terminals is outputting 24v and the other is detecting its presence. Hence the voltage is not very important, what it’s detecting is merely presence or not of a dead short between those two pins.
@huyongquan6554
@huyongquan6554 4 жыл бұрын
Very impressive. How about add nest gen3 diagram to demonstrate how to connect the OT1 OT2 of Boilers and nests through Valve grey and orange. That the Opentherm function can be achieve.
@Matt.ffgmatHexPulseChain
@Matt.ffgmatHexPulseChain Жыл бұрын
Hi Have you sorted out the problem with nest ? I am now in this situation. Thanks for any help.
@pineappleroad
@pineappleroad 7 ай бұрын
Unfortunately it’s not possible to use opentherm with multi zone heating (opentherm is a digital connection which doesn’t support multiple heating zones)
@marioz.3022
@marioz.3022 Жыл бұрын
Great video John!!! I just want to ask is it posible to add more zones in this system and how many relays i would need ?
@jwflame
@jwflame Жыл бұрын
You can add as many zones as you want. Each zone needs a valve and thermostat, thermostat output connected to the valve brown wire. All other wires connect as in the diagram. No relays required.
@Matt.ffgmatHexPulseChain
@Matt.ffgmatHexPulseChain Жыл бұрын
Great video. I have one question, how to do it with nest thermostat with don’t have 230v ?? Boiler is directly connected to the nest by the OpenTherm . How to send signal to zone valve?? I am trying to find some solution.. Thank you for any suggestions.
@jwflame
@jwflame Жыл бұрын
You will need to use the other terminals on the Nest to switch 230V for the valve motors. Opentherm is only control for the boiler.
@nagarajahnavaneethan6634
@nagarajahnavaneethan6634 Жыл бұрын
Very helpful. How could I accommodate a pump to this diagram please? I would like it to come on after the 2 port valve has fully opened. Thank you
@jwflame
@jwflame Жыл бұрын
Combination boilers have the pump inside the boiler, it's not a separately controlled component.
@nneethan5
@nneethan5 Жыл бұрын
Hi John, my apologies i should have been a bit clearer as to what pump i was referring to , the pump i am quoting here is the ufh manifold pump which is connected to one of the two zone valves in my setup. i think i will need to use the 230V switching diagram for this, any advise will be much appreciated. thanks
@jwflame
@jwflame Жыл бұрын
@@nneethan5 Yes, it's the 230V version. If it's a single UFH zone with only 1 thermostat, the pump connects to the switched output of the thermostat, which is also where the brown valve wire connects. Pump will run for a short time before the valve opens but this doesn't matter as it only circulates water via the manifold and UFH, not through the valve. For more than one UFH zone, the pump, thermostats and zone actuators are wired to a UFH controller, with the switched output from the controller connected directly to the valve brown wire.
@robertmccully2792
@robertmccully2792 4 жыл бұрын
Zones are great but not very efficient. Heat on first floor rises to second floor, and second floor heat get combined with first floor heat that has risen . The first floor is usual to cold and the second to hot. For this to really work correctly there needs to be a zones in every room upstairs . For that to work you need electrical dampers/valves to each room and a cold air/ water return in every room. Interesting theory on paper.
@millomweb
@millomweb 4 жыл бұрын
Your floors aren't very efficient ! Here, heat on downstairs and upstairs rooms are very cold ! I have 5 zones: House, hot water, 3 bedrooms.
@arinb12
@arinb12 6 ай бұрын
What if my UFH controller has volt free output switching for the boiler, but my boiler wants. 240v live return to turn on?
@jwflame
@jwflame 6 ай бұрын
Connect 240V to one of the output terminals, the other connects to the boiler. 'Volt free' is just a switch with nothing connected to it, you can use it for any voltage you want.
@saidhissoufi277
@saidhissoufi277 2 жыл бұрын
Hi Mr John what is the best route to become a qualified electrician, knowing that I am 39 years old? Thank you
@jwflame
@jwflame 2 жыл бұрын
www.electricalcareers.co.uk/joining-the-industry/training-routes/
@asifk159786
@asifk159786 10 ай бұрын
Can A & B be connected in any order to the orange and grey
@jwflame
@jwflame 10 ай бұрын
Yes. They are just connected together when heat is required, so makes no difference.
@asifk159786
@asifk159786 10 ай бұрын
@jwflame would I still require the link from L to 1. I assume your using hive in this set up.
@jwflame
@jwflame 9 ай бұрын
​@@asifk159786NO, as the title states, this is for volt free switching. If you connect L to any part of a volt free boiler input, it will destroy the boiler circuit board. If the boiler has 230V switching, use the 230V wiring as described here: kzbin.info/www/bejne/b2nPi6mEbtZqqNk
@asifk159786
@asifk159786 9 ай бұрын
@jwflame thanks. Boiler in question is ideal vogue which I belive isn't low voltage. The boiler has 2 outputs room stat and time. Similar A&b so I think the low voltage video should be fine.
@JohnnyB6969
@JohnnyB6969 Жыл бұрын
Hello Dear HOPEFULLY someone knows 😊 where is SL In my glow worm energy 25c. on the left side where is mains I have L N E RT and on the right side of PCB have B OFF(burner) RT (24v )BUS (+-) At the moment I have salus room thermostat connected to RT 24v My diagram required SL Thank you guys 😊
@jwflame
@jwflame Жыл бұрын
If you are using 24V switching, it's the two 24V RT terminals where the thermostat is connected. The L and RT terminals are the equivalent if using 230V switching. These must NOT be connected in any way to the 24V terminals, doing so will cause damage.
@robswingler
@robswingler 4 жыл бұрын
Only problem here is you would have a 5 core flex going into the 2 port valve with single insulated cables inside the outer sheath with both 230v and 24v when really they would need double insulation atleast to keep the 230v away from the 24v.
@alhughes9698
@alhughes9698 3 жыл бұрын
Think you have misread the diagram as the only 24 volt connections are from the relay terminals 1 and 2 on to the boiler terminals A and B. All conductors to the 2 port valves in this instance have mains 230 voltage on them.
@robswingler
@robswingler 3 жыл бұрын
Al Hughes no I think you’ve misread its terminals A & B which clearly go upto the 2 port valve which has 240v at it too.
@alhughes9698
@alhughes9698 3 жыл бұрын
@@robswingler i see whats happening now, i am looking at the second diagram with the relay in not the first diagram which is what you are on about :P
@JasperJanssen
@JasperJanssen 2 жыл бұрын
A better option than a relay so you can do most of the work in 230V would be using the other kind of zone valve, with a 24v motor. There’s no real reason to do this all by switching non touch safe voltages, afaict.
Central Heating - How the mid position Y plan 3 port valve works
19:26
Combi Boiler with Two Heating Zones, 230V Switching
15:26
John Ward
Рет қаралды 80 М.
Каха ограбил банк
01:00
К-Media
Рет қаралды 11 МЛН
What is a Volt-Free Contact? | Electricians Q&A
4:36
eFIXX
Рет қаралды 32 М.
Frost Thermostat Installation - S plan, Y plan, Combi
16:17
John Ward
Рет қаралды 26 М.
Inside a clever Honeywell boiler wiring centre and a 3-way valve.
23:02
EPH CombiPack 4 - How To Wire - OpenTherm
20:32
Allen Hart
Рет қаралды 33 М.
Extension underfloor heating to combi boiler
16:05
Loving Plumbing
Рет қаралды 18 М.
How an S-Plan heating system works
11:59
Boiler Boffin
Рет қаралды 23 М.
How To Wire Viessmann 050-w Opentherm or 240v switching
10:30
Allen Hart
Рет қаралды 42 М.
4 Wire Honeywell zone valve overview
16:10
Homeowner DIY
Рет қаралды 740
Combi Boiler Thermostat Wiring
26:16
John Ward
Рет қаралды 260 М.
Самый дорогой кабель Apple
0:37
Romancev768
Рет қаралды 296 М.
Игровой Комп с Авито за 4500р
1:00
ЖЕЛЕЗНЫЙ КОРОЛЬ
Рет қаралды 2 МЛН
⚡️Супер БЫСТРАЯ Зарядка | Проверка
1:00
КРУТОЙ ТЕЛЕФОН
0:16
KINO KAIF
Рет қаралды 3,3 МЛН
Choose a phone for your mom
0:20
ChooseGift
Рет қаралды 6 МЛН