Extension underfloor heating to combi boiler

  Рет қаралды 18,682

Loving Plumbing

Loving Plumbing

Жыл бұрын

So its not often we get to install a small underfloor heating system to a combi boiler so I thought I would run through the process of how we carry it out. I've kept to the manufactures guidelines on this, and although there are different ways and methods this is how most underfloor heating systems are piped up.
#lovingplumbing #underfloorheating #combiboiler #heating #plumbing

Пікірлер: 68
@karlj.4798
@karlj.4798 8 ай бұрын
Thanks a lot for taking the time and trouble for making the video. Our system mirrors yours, kitchen extension with UFH to existing boiler. Couldn't work out why we were getting water hammer from zone valves when the CH/UFH shut off! No bypass for the pump run on!! Doh.... Cheers 😊 👍
@over-engineered
@over-engineered Жыл бұрын
Seeing this manufacturers manifold has convinced me to use Nu-Heat again on the house I’m currently building. And yes I installed the underfloor heating on previous.
@loving-plumbing
@loving-plumbing Жыл бұрын
Thanks for the comment. What's the difference may I ask?
@over-engineered
@over-engineered Жыл бұрын
@@loving-plumbing their’s was much more concise. not cheap though.
@MJTiffPlumbing
@MJTiffPlumbing Жыл бұрын
Great video buddy, explained why you did it the way you did perfectly…👌🏼....... Must be the season for some UFH install's eh mate.......
@loving-plumbing
@loving-plumbing Жыл бұрын
Nice one Mark. Ha ,yeah your decoiler definitely works better then mine!
@muppit666
@muppit666 Жыл бұрын
One of the reasons to pressure the underfloor pies to 6bar is to expand them slightly so when the screed goes down there will be a tiny gap between the screed and pipe to allow for expansion when the heating goes on.
@lambshank22
@lambshank22 Жыл бұрын
Baileys work at the end was terrific! Truly remarkable! You should be proud
@loving-plumbing
@loving-plumbing Жыл бұрын
What about me Sam! What about me 🤣🤣
@11mimiriri
@11mimiriri 5 ай бұрын
:-)))))
@mrcombiBedford
@mrcombiBedford 7 ай бұрын
Excellent love it, ALL new systems should be UFH. Rads are the worst way to heat a home etc. regards George Staszak Mr Combi 🤩👍
@mrcombiBedford
@mrcombiBedford 6 ай бұрын
Thanks for your comment, all the best, George 👍
@waynehardiman5443
@waynehardiman5443 10 ай бұрын
Great video and knowledge is amazing like your other videos what boilers this the 4000 or the 8000 and can you use the plug in room stat still with the radiator side and use external controls for the underfloor or will you need to hardwire a new controller for the heating I’m so bad at electrics
@rishidoshi7280
@rishidoshi7280 10 ай бұрын
Great video. I'm looking to get Tado installed. Regarding the electrical wiring for the 2 port valve, I understand you need to install one for the radiator and one for the UFH after the flow pipes from the boiler are tee'd off. But I'm keen to understand how these motorised valves get their power? As in, where does the black cable coming out of the motorised valve connect into? Any idea how each of these motorised valves get their power to turn on/off? For example, for the UFH, do you install one 2 port valve in the manifold area which gets its power directly from the manifold / UFH wiring control centre and turns on once the thermostat calls for heat? And to control and turn on the radiators, do you install the second 2 port valve next to the boiler so it can collect its power directly from the boiler or from the Tado wireless receiver (and therefore switch on once the Tado TRV is calls for heat)?
@maz1095
@maz1095 5 ай бұрын
very good information, I am installing a UFH system to my combi system currently. From the video I will add in a bypass. But I had a question on the 2port valves. Should there be 2 port valves on both the CH to radiators and the UFH manifold?
@andymav3023
@andymav3023 Жыл бұрын
Great video mate just wondering why it has a pump on the manifold when the boiler has its own pump ? How would that work
@maurifederi5817
@maurifederi5817 Жыл бұрын
Hi. Is it posible to heat shower floor? And all bathroom?
@riverpud
@riverpud Жыл бұрын
Are you not ending up with uneven floor temperatures with the ufh ?
@zedzed1046
@zedzed1046 5 ай бұрын
What was the insulation under the screed and how thick a screed is being poured, thanks.
@deanmiles8421
@deanmiles8421 9 ай бұрын
Hey, did you actually use the pump that was on the manifold? Can't imagine you did but??
@E4OUTLAW
@E4OUTLAW 5 ай бұрын
Should the bypass not tee in before the tee for the underfloor heating flow tee? 🤔
@nes531
@nes531 7 ай бұрын
I would not allow that as it’s to close to ceiling plasterboard a screw anything could go in it
@joehaskett90
@joehaskett90 6 ай бұрын
Worcester have put a technical bulletin out for connecting ufh manifolds to their boilers TB 0137 B. It needs hydraulic separation
@UndisputableFact
@UndisputableFact 4 ай бұрын
I’m looking to do this on my system, but I plan to stick another pump before the rads otherwise I think the CCT will just become a bypass when rads are calling for heat. Would you install an identical erp pump to the boiler and wire it to the boiler’s pump so it mirrors the pump modulation?
@waynenixon729
@waynenixon729 Жыл бұрын
I'm fairly sure you fill up the underfloor through a hose connected to the Manifold, not use the boilers filling loop? What did the manifolds' installation instructions say?
@loving-plumbing
@loving-plumbing Жыл бұрын
Yeah you can do that also. 👍
@hdhanji8006
@hdhanji8006 Жыл бұрын
I always fill up with hosepipe and open drain off until all air is pushed out from the loops individually. Once done, open the isolation valves on F&R pipes and bleed from manual air vent on manifold
@riverpud
@riverpud Жыл бұрын
Best thing is make up your own filling kit by way of a 1/2 hp pump and purge the whole system at once particularly a large house.
@aerenewables
@aerenewables Жыл бұрын
I agree with both those comments. Should not be chopping joists ! Well illegal and takes strength out of would and needs separation
@loving-plumbing
@loving-plumbing Жыл бұрын
Hey Erik. Thank you for the comments. I knew the underside notches would ruffle some feathers 🤣. It's totally legall. Check the regs . Like I said in the video a close coupled Tee or hydraulic separation is also ok, but that is not how 99 percent of combi boilers are plumbed in , plus no underfloor heating manufacture I've worked with say that is mandatory. The manifold has a balancing valve to reduce flow temperature . Cheers
@aerenewables
@aerenewables Жыл бұрын
@@loving-plumbing just coz 99 percent of people do combis like that doesn’t mean it’s correct and manufacturers dont know what they are doing most of time. Just coz media says that how you should do it, again doesn’t mean its correct. Be a shepherd and not a sheep
@loving-plumbing
@loving-plumbing Жыл бұрын
@@aerenewables So your advice is to ignore manufacturers instructions. Cheers Erik....
@aerenewables
@aerenewables Жыл бұрын
@@loving-plumbing no bud do your research every job is different manufacturers just cover their own arses they don’t care about the rest of the system. Why dont you look into a hydronics coarse it will change your life
@loving-plumbing
@loving-plumbing Жыл бұрын
@@aerenewables In the video I referenced low loss headers and close coupled Tee's on several occasion. I'm well aware of system design. As I said. We are following manufacturers instructions in this video..... As do most plumbers , builders and homeowners.
@alialywa4892
@alialywa4892 10 ай бұрын
Job is not complete?
@HarryMasters-hd3pn
@HarryMasters-hd3pn 8 ай бұрын
Should of put laff on the bottom of the joists, then your not notching the joists
@Anthony-hs8zi
@Anthony-hs8zi Жыл бұрын
Ccts all day
@rangeheating1143
@rangeheating1143 Жыл бұрын
Your figures for where you can and can’t notch the joists are correct except for the fact that you can only notch the top of the joist. You aren’t allowed to cut anything out of the bottom of the joist
@loving-plumbing
@loving-plumbing Жыл бұрын
This is not true
@jeffglaister9620
@jeffglaister9620 Жыл бұрын
From building control: Depth and position of notches must be within the zones shown in the diagram below and only in the top of the joists
@loving-plumbing
@loving-plumbing Жыл бұрын
@@jeffglaister9620 bottom of the joist can be notched if there is not, or will never be notches in the top
@loving-plumbing
@loving-plumbing Жыл бұрын
@@deanchapple1 that a uninsulated air gap
@loving-plumbing
@loving-plumbing Жыл бұрын
@@deanchapple1 even the electrician didn't use it..... 🤣🤣.
@andrewmillwardwatford9410
@andrewmillwardwatford9410 Жыл бұрын
Are you on the face book heating design forum ? This system will not be able to use a low flow temperature strategy as the manufacturer has mislead you into a high temperature lower efficiency system. You should do the system design not a lazy out of date supplier. Your workmanship is 1st class and to see you do this design 😞
@loving-plumbing
@loving-plumbing Жыл бұрын
Hi Andrew. I think you have to remember this is a quick underfloor heating job in a extension followed to plumbing schematics provided. I'm well aware of the benefits of adding a close coupled Tee underneath the boiler or even a low loss header. Although I appreciate this is not the best possible way it could be, I am not there to change controls or redesign the system. I mention several times in the video that you can indeed install additional components. I'm a great admirer of your videos and I'm sorry to have disappointed you on this one! 🤣. If I redesigned every system I worked on I would be out of the job. Thanks for the comment 👍👍.
@victoria-ud3xh
@victoria-ud3xh Жыл бұрын
@@loving-plumbing Is it really that difficult to add in some closed couple tees? hardly a system redesign. Just laziness more than anything
@loving-plumbing
@loving-plumbing Жыл бұрын
@@victoria-ud3xh lol. Clearly you have no idea what's involved.
@victoria-ud3xh
@victoria-ud3xh Жыл бұрын
Yes I do actually. It is certainly not a huge job, weird that you have the knowledge but you can't be asked to use it. That's british tradesman for ya lol
@loving-plumbing
@loving-plumbing Жыл бұрын
@@victoria-ud3xh 🤣🤣 cheers for the comments.
@deano6017
@deano6017 Жыл бұрын
nice video but Jesus Christ just let him do what he does and enjoy the video. I think he knows his stuff.
@loving-plumbing
@loving-plumbing Жыл бұрын
Cheers Deano!!!!!
@deano6017
@deano6017 Жыл бұрын
@@loving-plumbing I'm only an apprentice but I admire your work and how neat and tidy it is. I also dont know how you do some of the bends you do. I think it would be good if you did a video on how you do difficult bends and get the measurements ect.
@loving-plumbing
@loving-plumbing Жыл бұрын
@@deano6017 thanks Deano appreciate it. When we get some time I will try and do that. In reality we just work in a way where we try to use as little fittings as possible. It really just comes down to practice.
@deano6017
@deano6017 Жыл бұрын
@@deanchapple1 🤣
@WatchingTheo
@WatchingTheo 7 ай бұрын
Can only notch top of the joists... not the bottom... please re-read the regs...
@derekclark7545
@derekclark7545 4 ай бұрын
It's all wrong anyway, the other holes make the joist good for nothing, clipping pipes to joist, great for noise click click. You can get plastic over-clips (twin u shape) that sit on top or (bottom in this case), of the pipes that have a metal top (stops nails and screws) and a central fixing, these allow the pipes to move as there not tight like clips plus use can use hair felt across the wood. Don't clip within 600mm of a right angle as the pipe won't be able to expand, more click click. Spent more years first fixing in copper than plastic, just some of the tricks old gits do.
@James-en3oy
@James-en3oy 5 ай бұрын
Thats not regs 😂😂 well it is but top of joists not bottom
Smartening up my underfloor heating controls
46:36
Adam Cooke
Рет қаралды 49 М.
Finger weg von diesen 3 Dämmstoffen!
18:30
Der Fachwerker
Рет қаралды 476 М.
The child was abused by the clown#Short #Officer Rabbit #angel
00:55
兔子警官
Рет қаралды 24 МЛН
NERF WAR HEAVY: Drone Battle!
00:30
MacDannyGun
Рет қаралды 50 МЛН
THEY WANTED TO TAKE ALL HIS GOODIES 🍫🥤🍟😂
00:17
OKUNJATA
Рет қаралды 20 МЛН
Underfloor heating manifolds- How do they work? Radiators and Underfloor heating?
13:03
Connecting underfloor heating to a combi  part 1
3:35
Griffiths Heating & Renewables
Рет қаралды 15 М.
How to Install Underfloor Heating in an Old Property
28:36
Charlie DIYte
Рет қаралды 90 М.
Filling And Venting Your UFH Manifold
6:56
Multipipe Ltd
Рет қаралды 312 М.
Plumbing - How Does Underfloor Heating Work
7:04
Allen Hart
Рет қаралды 55 М.
Plumbing - Avoid Doing This! What Was I Thinking?
16:32
Blue Bulldog Plumbing
Рет қаралды 5 М.
Is Your Central Heating System Losing Pressure?
6:43
Skill Builder
Рет қаралды 339 М.
Under floor heating wiring explained
11:34
Urban Plumbers
Рет қаралды 48 М.
Your Underfloor Heating Could Be Better - Here Is How.
12:17
Urban Plumbers
Рет қаралды 78 М.
Installing the JG Underfloor Manifold
7:56
John Guest - Europe
Рет қаралды 12 М.