Concept of Effective Length Factor for Column Design | Manual Calculations ; Verify from Software |

  Рет қаралды 4,785

Analysis & Design Studio

Analysis & Design Studio

Күн бұрын

Пікірлер: 24
@Pylon_Design
@Pylon_Design Жыл бұрын
Thank You 💐 Informative 💐
@analysisdesignstudio3363
@analysisdesignstudio3363 9 ай бұрын
Thanks for Appreciation. Keep watching and sharing. ❤️
@aqsaneaz7904
@aqsaneaz7904 2 жыл бұрын
Very helpful video. Pls upload more videos of steel structures especially connection design.
@analysisdesignstudio3363
@analysisdesignstudio3363 2 жыл бұрын
Thanks Aqsa for appreciation. I have uploaded 3 videos of connection design using idea statica of the steel shed designed in Midas Gen.. In Sha Allah i will upload more... Please like subscribe and share with your circle...
@ahmedhyd867
@ahmedhyd867 2 жыл бұрын
Very much helpful, thanks
@analysisdesignstudio3363
@analysisdesignstudio3363 2 жыл бұрын
Thanks for appreciation..
@sirabetjonson
@sirabetjonson 2 жыл бұрын
Very effective teacher you are sir!
@analysisdesignstudio3363
@analysisdesignstudio3363 2 жыл бұрын
Thanks for appreciation.. Please share as well
@umraizsaifi8769
@umraizsaifi8769 2 жыл бұрын
this video has cleared my doubts . thank you bro. may your channel get millions subscribe . keep uploading the videos
@analysisdesignstudio3363
@analysisdesignstudio3363 2 жыл бұрын
Thanks brother for loving my efforts.. In Sha Allah in future,, more videos will be there ..
@umraizsaifi8769
@umraizsaifi8769 2 жыл бұрын
@@analysisdesignstudio3363 In sha Allah
@aravindhanvinayagam2430
@aravindhanvinayagam2430 2 жыл бұрын
Thank u sir, please upload more videos related to steel structure and give explanation IS 800 clauses
@analysisdesignstudio3363
@analysisdesignstudio3363 2 жыл бұрын
Thanks Aravindhan for appreciation.. As I live in the region where american code Aisc is frequently used. Thats why I make videos using this. But I will make videos on indian code as well soon...
@Godfather_Rolex1992
@Godfather_Rolex1992 2 жыл бұрын
Hi sir..I have doubt..column is UC 254*254*89 and beam is Ub then can you show us the calculation for kz value ...
@analysisdesignstudio3363
@analysisdesignstudio3363 2 жыл бұрын
Hi... Yes . But please make a hand sketch of members connecting at a joint showing length and orientation as well. Email me @ syedarsalanali2016@gmail.com. i will send u the calculatns
@ahmedyaqub2377
@ahmedyaqub2377 Жыл бұрын
Sir, How can I prevent cracks in non-loading partition walls due to deflected steel structural beams' interaction, please could you help me?
@analysisdesignstudio3363
@analysisdesignstudio3363 9 ай бұрын
As per your condition, wall under beam not likely to be damaged, so deflection limit need to be more strict like L/480 or depending on the code/spec you are following
@KHURRAMALIADAM
@KHURRAMALIADAM 11 ай бұрын
VERT WELL EXPLAINE
@analysisdesignstudio3363
@analysisdesignstudio3363 11 ай бұрын
Thanks for Sharing. Keep Sharing !
@shoaibalam7555
@shoaibalam7555 2 жыл бұрын
👍👍👍
@ahmedhyd867
@ahmedhyd867 2 жыл бұрын
Are they previously assigned or calculated by software in case of Ky and Kz, plz explain
@analysisdesignstudio3363
@analysisdesignstudio3363 2 жыл бұрын
Cant get ur question ..
@ahmedhyd867
@ahmedhyd867 2 жыл бұрын
In first case after performing design u got the parameters Ky=1.5 and Kz =.64 Is it assigned manually or calculated by software .
@analysisdesignstudio3363
@analysisdesignstudio3363 2 жыл бұрын
They are calculated by software itself
One Column Two Effective Length : Assign Lx and Ly
10:21
Civil Engineer Tonmoy Maity
Рет қаралды 18 М.
Леон киллер и Оля Полякова 😹
00:42
Канал Смеха
Рет қаралды 3,7 МЛН
小路飞和小丑也太帅了#家庭#搞笑 #funny #小丑 #cosplay
00:13
家庭搞笑日记
Рет қаралды 17 МЛН
Арыстанның айқасы, Тәуіржанның шайқасы!
25:51
QosLike / ҚосЛайк / Косылайық
Рет қаралды 639 М.
Effective Length Of Column(IS 456 , Annex E)
14:46
Parth Parikh
Рет қаралды 6 М.
Steel Design - Effective lengths of columns - SD424
6:39
FireSUN
Рет қаралды 34 М.
Pinned & Fixed Connection in RCC
13:08
EZ ENGINEERS PVT LTD
Рет қаралды 14 М.
Low Slope Roofing Wind Design:  ASCE 7-16 Example Problem
12:25
SOPREMA USA
Рет қаралды 13 М.
Slenderness Ratio Of Column:Effective length of column for different support condition
16:48
SD7: Steel Compression Member Design (Effective Length Factor 1)
10:50
Леон киллер и Оля Полякова 😹
00:42
Канал Смеха
Рет қаралды 3,7 МЛН