Conductors used in transmission line

  Рет қаралды 731,681

Sourabh Sharma Hindi Channel

Sourabh Sharma Hindi Channel

Күн бұрын

various conductors like AAC - All Aluminium Conductor, AAAC - All Aluminium Steel Reinforce, ACSR - Aluminium Conductor Steel Reinforced are explained in this video. (Learn More ↓↓↓↓↓↓↓↓↓↓↓↓↓)
You can watch complete video series through these links
Watch all videos of this series "Electrical Power Generation to Distribution" #EPG2D
Video 1) Electrical Power Generation to Distribution in Hindi → • Electrical Power Gener...
Video 2) Electrical power generation to distribution video 2 → in hindi • Electrical power gener...
Video 3) Electrical Substation explained → • Electrical Substation ...
Video 4) Electrical Substation "Double Bus One and Half Breaker scheme → • Electrical Substation ...
Video 5) Electrical Substation 220KV to 132 kv → • Electrical Substation ...
Video 6) Conductors used in transmission line → • Conductors used in tra...
Video 7) Electrical substation; Process of bus transfer / Electrical Power generation to distribution → • Electrical substation;...
Video 8) power line carrier communication / PLCC → • power line carrier com...
Video 9) power line carrier communication / video 2 → • power line carrier com...
Video 10) 132 to 33 kv Electrical Substation → • 132 to 33 kv Electrica...
The work of conductors is to transfer power form one end to another end there are some metals which have high conductivity like gold and silver but they are very much expansive so it is impractical to use them in high power transmission, we have only two choice i.e. copper and aluminium out of this aluminium is mostly preferred because it is price competitive, high corrosion resistant, good conductivity, high corrosion resistant and light weight. there are many types of aluminum conductors available;
1) AAC - All Aluminium Conductor
2) AAAC - All Aluminium Alloy Conductor
3) ACSR - Aluminium Conductor Steel Reinforce
4) ACSS - Aluminium Conductor Steel Supported
5) ACCR - Aluminium Composit Core Reinforced
6) ACCC - Aluminium Carbon Composit Core
these above choices are used extensively are used form power transmission to distribution at many places, out of these solid and hollow aluminium conductors are used in substation bus for space management and to get better accessibility however solid and hollow conductors are use in low and medium size substation bus. when bus size is large aac conductor is used
people also ask;
Why stranded conductors are used in transmission lines?
Which conductors are used for distribution lines?
What are the different types of conductors?
Which conductor is used in 11kV line?
conductor types and sizes
acsr conductor types and sizes
What is ACSR conductor & type?
What are the different types of conductors?
What is the difference between ACSR and AAAC?
How many types of conductors are used for overhead lines?
What is ACSR Dog Conductor?
What is Zebra conductor?
transmission line conductors
distribution line conductor
HTLW - high tension low weight conductor

Пікірлер: 466
@spacebasedsolarpowersbspsb6548
@spacebasedsolarpowersbspsb6548 4 жыл бұрын
One of the best video till date.... Keep up the good work... Have started following U... Very nice excellent bro....
@pradeeppadhan7604
@pradeeppadhan7604 2 жыл бұрын
Plqlqlqpqll
@malikonmike
@malikonmike 4 жыл бұрын
Too Good, informative, and on point.......Thanks, man.........Keep making
@sunitsarkar1878
@sunitsarkar1878 4 жыл бұрын
very useful information 👍👌
@RKCONCEPTCLASSES
@RKCONCEPTCLASSES 5 жыл бұрын
Very very thank you sir For this video ✌✌👍
@RKCONCEPTCLASSES
@RKCONCEPTCLASSES 5 жыл бұрын
Sir aapki ya video hamare liya bahut helpful rahi Thanks for this
@safayathossain9334
@safayathossain9334 3 жыл бұрын
Great Job
@NikG2211
@NikG2211 5 жыл бұрын
ACSR conductor are used beause it has good Tensile strenght and It overcome the SKIN Effect
@egbalhossain4389
@egbalhossain4389 Жыл бұрын
Thanks
@usmanghafoor7035
@usmanghafoor7035 3 жыл бұрын
Wires ko animals k nam pr q rkha gay h...plz reply
@ViewersOP295
@ViewersOP295 3 жыл бұрын
Using aluminium only in conductors increase sag in overhead line.
@zerotoinfinite2023
@zerotoinfinite2023 5 жыл бұрын
इतना कॉलेज में नही सिखाते आज कल जैसे आप बताते हो।
@santoshkumarvijay5684
@santoshkumarvijay5684 4 жыл бұрын
Sir 33kv cable को किसी शहर के मकानों से पास पोलो के सहारे से ले जाने का कोई नियम है तो बातये की मकानों से कितनी दूरी पर पोल और 33kv केबल जाएगा
@rohitahir8972
@rohitahir8972 3 жыл бұрын
Hi bhai
@technicalindia2513
@technicalindia2513 2 жыл бұрын
1.2m
@zoomon4192
@zoomon4192 4 жыл бұрын
Beginner electrician ke liye bohut valuable information Thank you so much for your kind information!
@ElusiveTruth
@ElusiveTruth 5 жыл бұрын
Graphics were awesome but I only caught like 9 words in English.
@jimeralexandercubidesgambo1792
@jimeralexandercubidesgambo1792 5 жыл бұрын
x2, I didn´t get it.
@joserobertofongnakazawa2439
@joserobertofongnakazawa2439 4 жыл бұрын
I think he's not speaking English, I can't clearly understand anything he said except by Aluminium Conductor.
@sadabalam6503
@sadabalam6503 5 жыл бұрын
Conductor ka name Animal se q rakha gaya?????? Dum hai to iska answer batao
@sourabhsharmahindichannel3000
@sourabhsharmahindichannel3000 5 жыл бұрын
Aap ko koi specific or interesting reason pata ho to jaroor bataaiye, mere hisaab se to inko asaani se pehchana jaa sake is liye hi inhe ye naam diye hai
@sadabalam6503
@sadabalam6503 5 жыл бұрын
Asani se pahchana jaye wo thik hai par animal ke name se he q rakha
@startplayingjust10mins16
@startplayingjust10mins16 4 жыл бұрын
Then why we use copper in Railways
@NikG2211
@NikG2211 5 жыл бұрын
ACSS,ACCR and ACCC conductor are also know as high temparature low sag Conductor (HTLS) having good tensile strenght,Less DC resistance,More AMPACITY. these conductor carries Double power As campare to Convetional ACSR and AAAC conductor
@aspire1883
@aspire1883 8 ай бұрын
But the main disadvantage is that it produces power loss as the ambient temperature rises which increases the resistance and hence power loss.
@skc24063
@skc24063 4 жыл бұрын
Symmetrical fault ka videos bnaye please
@prasadakhilesh7256
@prasadakhilesh7256 5 жыл бұрын
Nice Information sir, Thank u so much
@dr.chinmayabehera3668
@dr.chinmayabehera3668 4 жыл бұрын
Can you provide line data (i.e. R,X,B of 440, 220,132,33 and 11 kV, and 400 V)
@gbalabala9725
@gbalabala9725 Жыл бұрын
It is of RYB 400, 220, 132, 66, 33, 11kv, and Lt voltages 440/254. Volts.
@Imtiyaz5power
@Imtiyaz5power 4 жыл бұрын
Kaash aisa Hamko Engineering College mai Sikhtay... Aise. Animation se.... Par itne gadhe nay professor the jo bas Rattu tota jaise Theory padha ke nikal lete....
@s.tiwariVlog
@s.tiwariVlog 5 жыл бұрын
Thnks a lot sir...alway waiting for ur next video
@aditychand8817
@aditychand8817 5 жыл бұрын
Please sir Uppcl je ya ssc je ki taiyari karayen. Bahut demand hogi
@prostudios96
@prostudios96 5 жыл бұрын
sir, very nice and informative video ... but can u tell which software are u using for that substation design ....which u kept on scrolling during the video to make us understand..???
@sourabhsharmahindichannel3000
@sourabhsharmahindichannel3000 5 жыл бұрын
for 3D mdeling- Autodesk Maya
@VaibhavBanajwade
@VaibhavBanajwade 4 жыл бұрын
What is the name of software used in the initial part of video which shows the substation??. It's really good and imaginative.
@Rkminarline
@Rkminarline 4 жыл бұрын
3d maya
@MKSMdesi
@MKSMdesi 5 жыл бұрын
Sir which software, you use for this 3D animation and
@alwarpurushotham9999
@alwarpurushotham9999 4 ай бұрын
Hsi dir nice explation which software used for 3d diagram
@sourabhsharmahindichannel3000
@sourabhsharmahindichannel3000 3 ай бұрын
मुझे 4 सॉफ्टवेर लगे इसे बनाने में 1- Adobe Photo Shop - Image Editing 2- Blender - 3D Modeling 3- Adobe After Effect - Compositing and Video Editing 4- Active Presenter - Screen Recording
@RockyBhai-be9gk
@RockyBhai-be9gk 5 жыл бұрын
bhai copper ka rang kala nhi green ho jata h after corrosion
@sourabhsharmahindichannel3000
@sourabhsharmahindichannel3000 5 жыл бұрын
Ok, U got it that's Important
@ElectricWorldVehicles
@ElectricWorldVehicles 4 жыл бұрын
Electrical supervisor exam syllabus Ki video banye Please MPEB A Class Supervisor
@akashchourasiya6316
@akashchourasiya6316 5 жыл бұрын
Its nice to know about the power distribustion like this Its very helpfull to learn and understand the complex concept in a diff manner Thankyou sir☺️
@kanagaglory3699
@kanagaglory3699 2 жыл бұрын
Could you please explain in English
@madtolive4423
@madtolive4423 5 жыл бұрын
What is the full form of ACCR CONDUCTOR
@sourabhsharmahindichannel3000
@sourabhsharmahindichannel3000 5 жыл бұрын
Aluminium Conductor Com-posit Reinforced
@satishverma1130
@satishverma1130 4 жыл бұрын
प्रिय सौरभ जी आपके वीडियो बहुत अच्छे हैं, आप बहुत अच्छे से समझाते हो. मैं इलेक्ट्रिकल से नहीं हूँ पर मैं सभी तरह की इंजीनियरिंग ड्राइंंग बनाता हूँ वहाँ मैंने Zebra, Panther आदि शब्द पढ़े थे इसलिए मैंने आपका ये वीडियो देखा. वीडियो वाकई अच्छा है. क्या आप ये बता पाएंगे कि ये नाम Dog, Zebra या Panther क्यों रखे हैं?
@Muskan1Chaurasiya
@Muskan1Chaurasiya 2 жыл бұрын
Sir, please continue it again🙏🙏🙏🙏🙏🙏
@shivamsahu6716
@shivamsahu6716 4 жыл бұрын
Nice..very well explained bhai 👍. logical with all dots connected.keep it up. Plz try to give answers of questions asked in comments.
@aashishp007
@aashishp007 4 жыл бұрын
Nice information 👍 What should be the Conductor size for 22kv power ?
@farhan1868
@farhan1868 3 жыл бұрын
Depends
@venkatyalamati3285
@venkatyalamati3285 5 жыл бұрын
Thankyou so much for this video bro..... Dhanyavaad🙏🙏🙏
@Morena855
@Morena855 5 жыл бұрын
Great information Thanks a lot Please keep it up this series👍👍👍
@ravikumar20062002
@ravikumar20062002 4 жыл бұрын
Pl make some video on substation switch gears. LV &HV
@vijaykumarps3731
@vijaykumarps3731 3 жыл бұрын
Copper Sp Gr is 8.8 and that of Al is 2.6. For the same length but double diameter Aluminium cable weighs 18% more than copper
@karthiksd3287
@karthiksd3287 4 жыл бұрын
Sir pls give me the link for downloading 3d model of substation for illustration purpose.
@sourabhsharmahindichannel3000
@sourabhsharmahindichannel3000 4 жыл бұрын
First go to Autodesk site and download and install Autodesk maya on you Desktop. If you want to purchase it that's great other wise take 30 days trial and then contact me I will send you the model.
@karthiksd3287
@karthiksd3287 4 жыл бұрын
@@sourabhsharmahindichannel3000 Sir thank u for your reply,I already used from few months ago,I want only substation 3d model file. Sir pls provide 3d model file link.only for teaching purpose.
@sourabhsharmahindichannel3000
@sourabhsharmahindichannel3000 4 жыл бұрын
@@karthiksd3287 please give me email Id.
@karthiksd3287
@karthiksd3287 4 жыл бұрын
@@sourabhsharmahindichannel3000 karthiksd1998@gmail.com
@gokulbeta
@gokulbeta 4 жыл бұрын
@@sourabhsharmahindichannel3000 Sir, kindly send for me to gokuleerr@gmail. Com
@venkatyalamati3285
@venkatyalamati3285 5 жыл бұрын
Please make a video on working of Modular Multilevel Converter type VSC based STATCOM.... Because that is actually used in Indian grids now a days for reactive power support on system...
@sourabhsharmahindichannel3000
@sourabhsharmahindichannel3000 5 жыл бұрын
Do you have working experience on this?
@AYODHYA933
@AYODHYA933 4 жыл бұрын
Very important topic hi sir very.... nice
@muztaa1235
@muztaa1235 5 жыл бұрын
Awesome great way to explain
@supriyomondal4286
@supriyomondal4286 3 жыл бұрын
Sir agar voltage borana par current kamti ha to phir high voltage line ki conductor low voltage line sa moti ku hoti hai
@sourabhsharmahindichannel3000
@sourabhsharmahindichannel3000 3 жыл бұрын
Aaap apne colony ke line se pure sehar ke line ko compare kar rahe hain., badi transmission line me voltage to kafi haigh hota hi hai or current be aap ke colony ki line se jyada hota hai, is liye.
@erajay2010
@erajay2010 5 жыл бұрын
Bahut achi video h sir Thanks
@manjeetsahu4490
@manjeetsahu4490 4 жыл бұрын
Yaar transmission me toh high viltage hota h or low current hota h. Toh ye transmission line k bare tm 300 amps kaise bol skte ho Jab ki current toh bohot hi low hota h about 0.02 amps
@Maharana_Rahul
@Maharana_Rahul 4 жыл бұрын
Bhai jha generation hota hai vha transmission line me 300 kya 400 amp current chalti hai fir ring system se ise distribute kiya jata hai alag alag substation pe
@SHAYAR_EE
@SHAYAR_EE 4 жыл бұрын
Sir what is sag. Pls make a vdo on it.
@prathampurush1730
@prathampurush1730 4 жыл бұрын
Sirji mutual aur self induction ko detail me explain kijiye
@shivbhaktrahulshimpi6783
@shivbhaktrahulshimpi6783 3 жыл бұрын
Ct pt
@akashchourasiya6316
@akashchourasiya6316 5 жыл бұрын
Sir make new video ....we are waiting to watch.
@KKz420
@KKz420 4 жыл бұрын
whats that graphical software u using for animation???
@sourabhsharmahindichannel3000
@sourabhsharmahindichannel3000 4 жыл бұрын
Autodesk maya
@thanveershadan7917
@thanveershadan7917 4 жыл бұрын
Which software is that..substation which you have shown??
@sourabhsharmahindichannel3000
@sourabhsharmahindichannel3000 4 жыл бұрын
Autodesk maya
@rahulpaul1988
@rahulpaul1988 5 жыл бұрын
circuit theory related video please share with brife describe. this is my request for you.
@narendersharma5523
@narendersharma5523 4 жыл бұрын
Best Best Best knowledge and explanation
@sourabhsharmahindichannel3000
@sourabhsharmahindichannel3000 4 жыл бұрын
Thanks
@ajitvpatil
@ajitvpatil 4 жыл бұрын
Sir, please explain about Gas insulated substation
@nizamuddinkhalid2956
@nizamuddinkhalid2956 4 жыл бұрын
How I wish this video comes with English Subtitle.
@sourabhsharmahindichannel3000
@sourabhsharmahindichannel3000 4 жыл бұрын
I will upload this soon in English language
@manthanpatel1640
@manthanpatel1640 3 жыл бұрын
sir which software you are using for presentation?
@sourabhsharmahindichannel3000
@sourabhsharmahindichannel3000 3 жыл бұрын
Autodesk Maya
@Mukhrambhaskar
@Mukhrambhaskar 2 жыл бұрын
Sir aap ka har notification chahiye
@VishalKumar-nv3kh
@VishalKumar-nv3kh 4 жыл бұрын
Very nice video sir.....dear sir I am working in transmission line...this video is very useful for us .....and all electrical engineers.....thank you so much sir...
@smateen2263
@smateen2263 5 жыл бұрын
Sir thanks for your all video this are very useful. Please give some videos on electrical engineer jobs related like JE. AEE or electrical contractor working of contractor wich may be helpful for all students
@shibasankarguin2931
@shibasankarguin2931 5 жыл бұрын
Now a days all bus such as main bus and transfer bus are made of moose conductor, even in 33kv,132kv,and 220kv bus bar systems
@sourabhsharmahindichannel3000
@sourabhsharmahindichannel3000 5 жыл бұрын
Thanks
@shibasankarguin2931
@shibasankarguin2931 5 жыл бұрын
@@sourabhsharmahindichannel3000 most welcome
@upeshkumarpatel5263
@upeshkumarpatel5263 3 жыл бұрын
Sir trasmisan line ni do pole કી duri kitni hoti he.11.. Kv.66kv.132. Kv.220. Kv.400. Kv.765. Kv. In sare ki vidio banana sir
@kartikdange2135
@kartikdange2135 4 жыл бұрын
What is the distance between 2 poles of 11kv, 22kv and others wanted to know about this
@nitinnarvekar8936
@nitinnarvekar8936 3 жыл бұрын
Sir, ye 3d diagrams aap kis software me bankrate hai. Mai apka course kharidna chats hu. I want to make such diagrams, please help me, to make such 3d diagrams, I will pay your fees.
@vinayakmhatre1280
@vinayakmhatre1280 3 жыл бұрын
132kv ,630sqmm cabel straight joint and intermission join ka video dijiye sir
@gulamdastgir6804
@gulamdastgir6804 4 жыл бұрын
Sir, plz 765kV D/C foundation, Erection and stringing video upload plz
@tarungupta8197
@tarungupta8197 5 жыл бұрын
Sir please tell which 3d software you used please sir it will help me in my final year project sir
@sourabhsharmahindichannel3000
@sourabhsharmahindichannel3000 5 жыл бұрын
Autodesk Maya
@maheshashankar48
@maheshashankar48 2 жыл бұрын
Can we use zebra conductor for 440V AC LT supply over head lines??
@rambalikumar7287
@rambalikumar7287 4 жыл бұрын
bhai thora aur hindi use kr lo
@nileshyadav2413
@nileshyadav2413 5 жыл бұрын
Super sir
@tejinder6329
@tejinder6329 5 жыл бұрын
Very gud nice video
@rameshtripathy5978
@rameshtripathy5978 4 жыл бұрын
Very good description & informative too !
@omprakashtaparia5228
@omprakashtaparia5228 3 жыл бұрын
Best video so far. Wanted to manufacture conductor wire.so pls inf more details.we also looking for joint venture For making conductor wire and making transmission line.
@chandraprakashpatel4770
@chandraprakashpatel4770 3 жыл бұрын
Sir ALL ALUMINIUM ALLOY CONDUCTOR ME DOG CONDUCTOR KA VIDEO BANAYE PLEASE sir.
@mr_himanshukaushik
@mr_himanshukaushik 5 жыл бұрын
Types of wires , gauge and current rating and when choose bunch conductor or single ye video banaiye n sir ji
@mr_himanshukaushik
@mr_himanshukaushik 5 жыл бұрын
Kuchh to reply kariye?
@nagappapayannavar6486
@nagappapayannavar6486 4 жыл бұрын
Superb video explaination, you are great and hats off to your for your presentation style. Very effective and impacting. may you like may suggestion, you think of use of software for power transmission, distribution, loss minimisation and theft detection approach. this suggestion for system management and optimization
@Rajinderkumar-md5ez
@Rajinderkumar-md5ez 4 жыл бұрын
Sir please give information on control wiring of various voltage level bays in substations
@taiybaqureshi767
@taiybaqureshi767 4 жыл бұрын
Wao sir very nice video sir
@saratmondal2000
@saratmondal2000 5 жыл бұрын
We eagerly wait for your next video.
@M.Sharique
@M.Sharique 5 жыл бұрын
Best Explanation
@maheshmishra6902
@maheshmishra6902 4 жыл бұрын
Sir plz make a video to cover all ACSR conductor weasel Rabbit wolf and all
@shahbazshaikh7790
@shahbazshaikh7790 4 жыл бұрын
Thanks bhai, very informative video in details.
@manishkumar-zh1ll
@manishkumar-zh1ll 5 жыл бұрын
please make video on types of under ground cable also
@sourabhsharmahindichannel3000
@sourabhsharmahindichannel3000 5 жыл бұрын
Nice Idea!!! thanks
@farrukhsial3528
@farrukhsial3528 4 жыл бұрын
Please specify the strength of aluminum wire in mm
@Mr053125
@Mr053125 5 жыл бұрын
very good information. thanks
@arijitpatra9771
@arijitpatra9771 2 жыл бұрын
Why indian railways does not start use Aluminium conductors instead of copper conductor?
@Curious1598
@Curious1598 5 жыл бұрын
Can you please tell me which conductors are used in Ultra high voltage dc transmission? It's capacity. In video they are upto 400kv
@sourabhsharmahindichannel3000
@sourabhsharmahindichannel3000 5 жыл бұрын
Zebra conductor can be used if current remain within range and to avoid corona loss bundling is needed
@jagdishpandor6842
@jagdishpandor6842 3 жыл бұрын
@@sourabhsharmahindichannel3000 a j J I'll M Hmm M
@neha9554vn.
@neha9554vn. 5 жыл бұрын
Tqq respected sir
@mdabid.8941
@mdabid.8941 5 жыл бұрын
very clear explained Sir!
@schauhan912
@schauhan912 5 жыл бұрын
Thanks for this video 👍👍👍👍👍👍👏👏👏👏👏👏 sir please make a new videos on scr and thyristor. And I am waiting on your next video thankyou.
@ShekharKumar-jl4xf
@ShekharKumar-jl4xf 4 жыл бұрын
Thanks for making this video sir 👌👊👊👊....
@amgothjayanth3194
@amgothjayanth3194 4 жыл бұрын
Sir this is good i dont know much hindi so, could please explain in english 🙏 sir
@Ajeetthakuriya
@Ajeetthakuriya 5 жыл бұрын
Nice knowledge sir
@swapnilwaghmare1294
@swapnilwaghmare1294 5 жыл бұрын
Very informative video. Thank You Sir.
@Maharana_Rahul
@Maharana_Rahul 4 жыл бұрын
Sir SF6 circuit breaker per video banaiye..
@sourabhsharmahindichannel3000
@sourabhsharmahindichannel3000 4 жыл бұрын
Ji Rahul ji
@maksudalam2697
@maksudalam2697 5 жыл бұрын
Sir we have used Zebra conductor in 765KV transmission line
@sourabhsharmahindichannel3000
@sourabhsharmahindichannel3000 5 жыл бұрын
Thanks Makusd ji, please share more details here it will be beneficial for us
@rajkishan1799
@rajkishan1799 5 жыл бұрын
@@sourabhsharmahindichannel3000 sir ji.. Electrical job Available hai kya
@me.parwezalam3756
@me.parwezalam3756 3 жыл бұрын
Maksud Alam..I think in 765kv me bull conductor
@maheshkandare82
@maheshkandare82 4 жыл бұрын
Very nice video sir..
@prakashs538
@prakashs538 Ай бұрын
Knowledge of overhead conductors was very useful to me
@SANJAYKESARWANI09
@SANJAYKESARWANI09 5 жыл бұрын
Distribution tak k saare videos Bana dijiye sir .. LT line tak k.. So that koi bhi confusion na ho.
@sourabhsharmahindichannel3000
@sourabhsharmahindichannel3000 5 жыл бұрын
ji bkilul yehi kosis hai
@gulamdastgir6804
@gulamdastgir6804 5 жыл бұрын
Sir plz tell basic of transmission line of tower foundation, erection and stringing
@sourabhsharmahindichannel3000
@sourabhsharmahindichannel3000 5 жыл бұрын
I will cover this very soon
@muhammadtalalkhan8494
@muhammadtalalkhan8494 5 жыл бұрын
Kindly urdu mai bola kerhen, hard Hindi ko samjna buhat mushkil hota hai. Apki videos buhat achi hen. Kafee mehnat ki hai apnay.
@RohitKumar-yy9mp
@RohitKumar-yy9mp 3 жыл бұрын
Saurabh sharma ji HVDC per bhi ek video banao bauth acha kaam kar rahe ho aap 🙏🏿🙏🏿🙏🏿🙏🏿🙏🏿
Conductors used in Transmission and Distribution Line
24:40
ELECTRICAL ENGINEER
Рет қаралды 352 М.
Как мы играем в игры 😂
00:20
МЯТНАЯ ФАНТА
Рет қаралды 3,2 МЛН
How To Get Married:   #short
00:22
Jin and Hattie
Рет қаралды 22 МЛН
отомстил?
00:56
История одного вокалиста
Рет қаралды 7 МЛН
power line carrier communication / video 2
16:04
Sourabh Sharma Hindi Channel
Рет қаралды 57 М.
Components of a High Voltage Electrical Transmission Line
6:57
The Engineering Power
Рет қаралды 81 М.
Installing ACCC® Conductor
4:34
CTC Global
Рет қаралды 20 М.
ACCC® Deadend Installation Training
11:22
CTC Global
Рет қаралды 41 М.
Identify equipment in a substation (35 - Electricity Distribution)
10:59
Transmission line Towers/Types of Transmission Line Towers
13:03
Electrical Passionate
Рет қаралды 15 М.
Types of Electric Insulator (in Hindi)
7:31
Deepakkumar Yadav
Рет қаралды 1,1 МЛН
HOW TRANSISTORS RUN CODE?
14:28
Core Dumped
Рет қаралды 448 М.
Как мы играем в игры 😂
00:20
МЯТНАЯ ФАНТА
Рет қаралды 3,2 МЛН