Current Transformer Knee Point Test || Hindi

  Рет қаралды 18,543

Insight Tecs

Insight Tecs

Жыл бұрын

Hello friends,
Welcome to testing series on Current Transformer.
In today's video we will learn about Knee Point Test of current Transformer.
Let us know if you have any queries in comments below.
Keep watching 👍
here is some links of video
current transformer basic
• Current Transformer Wo...
CT Polarity test
• Current Transformer Po...
CT Ratio test
• Current Transformer Ra...
current transformer wiring part-1
• Current Transformer Wo...
current transformer wiring part-2
• Current transformer wi...
also, you will get other equipment testing in the link provided below.
like, battery, transformer,
• Testing of Equipments
How to reading panel wiring drawing part-1 CT and PT wiring
• How to read Panel Draw...

Пікірлер: 32
@sudarshanb.v8722
@sudarshanb.v8722 Жыл бұрын
Sir your videos is very helpful for Maintenance Engineers, keep on giving this type of Videos. Thank you Very much Sir
@ashokmosun4204
@ashokmosun4204 Жыл бұрын
Good information 👍
@MANOJKUMAR-qo8qp
@MANOJKUMAR-qo8qp Жыл бұрын
🙏 Thank you Sir ji 🙏
@bikrammandal2582
@bikrammandal2582 Жыл бұрын
Thank you so much sir
@surendrakverma555
@surendrakverma555 Жыл бұрын
Thanks Sir 🙏🙏🙏🙏🙏🙏
@shihabahmedalkatrani3050
@shihabahmedalkatrani3050 Жыл бұрын
@shahbajkazi5253
@shahbajkazi5253 Жыл бұрын
Thank u sir
@shobharajjayswal7346
@shobharajjayswal7346 Жыл бұрын
🤝
@shahbaazahmad130
@shahbaazahmad130 Жыл бұрын
Sir but Vk/2 ka matlab 475 volt me 60 mA current aana chaiye as per name plate??? Plz clarify
@raghavmohan7599
@raghavmohan7599 Жыл бұрын
Super
@subhamsaurabh9150
@subhamsaurabh9150 Жыл бұрын
Thanks sir , sabhi equipment ka sabhi test ka video banaiye jo kee erection commissioning me helpful ho
@substationtestingandcommis3452
@substationtestingandcommis3452 Жыл бұрын
Testing of Substation Equipments: kzbin.info/aero/PLohZ_Ucl1PNpWcwScyH2STs-vNvyOJt5N
@rkhanda
@rkhanda Жыл бұрын
Sir good But as per knee point voltage recommend when we increase 10% voltage at last point then 1.5 times current increase eg if voltage 100 then current 50 mA And knee point 110 volt then current 75 mA It's as per my knowledge But u explain very good👍
@Insighttecs
@Insighttecs Жыл бұрын
Sir, what ever you understand is the theory of the knee point voltage, the design of the equipment is prepare with more safety margin and accuracy margine, so that the equipment couldn't fail in any test. there the results shows, are totaly prectical results. where the knee point is mentioned by manufacturer and we are testing the equipment to check the mentioned results are meets the actual test which is site "acceptance test"
@naveenchaddha2802
@naveenchaddha2802 11 ай бұрын
Sir please make a video for How to make/ disign/Calculat 200Amp - 400Amp Primary injection test set
@subhamsaurabh9150
@subhamsaurabh9150 Жыл бұрын
Sir, substation ke earthing connection ka bhee video banaiye
@pritampati7802
@pritampati7802 Жыл бұрын
Sir test k sath ager value kitna aaye according IEC ya pgcil rule k anusaran to acha hoga
@schoolhalchal4975
@schoolhalchal4975 10 ай бұрын
Voltage transformer ka kya jarurat hai... Direct veriac se connection dene se kya saubidha hoga krupaya bataye
@Insighttecs
@Insighttecs 9 ай бұрын
you need 2000V for higher voltage CT. thanks for watching...
@arunhazra1678
@arunhazra1678 Жыл бұрын
Sir please discuss on cvt testing
@skisrafil271
@skisrafil271 Жыл бұрын
Or wavetrep
@babloofarkade9799
@babloofarkade9799 Жыл бұрын
Why we connect vt rather than directly applie to ct through veriac
@muniraja5317
@muniraja5317 Жыл бұрын
Thank you sir 👍 and Knee point test should be checked once how many days sir ?
@substationtestingandcommis3452
@substationtestingandcommis3452 Жыл бұрын
Knee point is done only during commissioning of CT, no need to do in routine testing.
@pemasquare8845
@pemasquare8845 Жыл бұрын
Here at VK current is 16.8mA instead of 60mA...what is this?
@biswaranjanmohanty4730
@biswaranjanmohanty4730 6 ай бұрын
Sir at 950V current should 60mA but in the test you got 16.8mA. is it ok ?
@Insighttecs
@Insighttecs 6 ай бұрын
it is good.... as the knee point is more than 950V...
@abhishekpatel8038
@abhishekpatel8038 Жыл бұрын
Will the CT not saturate if we inject more than 950V on the secondary ?
@Insighttecs
@Insighttecs Жыл бұрын
generally not... if you test the ct for knee point.. then you will get the point of saturation.
@candice4626
@candice4626 Жыл бұрын
p͓̽r͓̽o͓̽m͓̽o͓̽s͓̽m͓̽ 🙂
@pawanbishnoi4400
@pawanbishnoi4400 Жыл бұрын
Kindly provide the drawing/nameplate also in comment box
@substationtestingandcommis3452
@substationtestingandcommis3452 Жыл бұрын
Current Transformer (CT) Nameplate Details kzbin.info/www/bejne/m6vRd6yqnbatacU
Current Transformer Knee Point Test
14:10
Insight Tecs
Рет қаралды 3,8 М.
Current Transformer IR Value Test || Hindi
11:51
Insight Tecs
Рет қаралды 18 М.
Жайдарман | Туған күн 2024 | Алматы
2:22:55
Jaidarman OFFICIAL / JCI
Рет қаралды 1,5 МЛН
MEGA BOXES ARE BACK!!!
08:53
Brawl Stars
Рет қаралды 35 МЛН
NERF WAR HEAVY: Drone Battle!
00:30
MacDannyGun
Рет қаралды 40 МЛН
Current Transformer Ratio Test|| Hindi
14:24
Insight Tecs
Рет қаралды 17 М.
TESTING OF CURRENT TRANSFORMER
26:14
Gyaan ELECTRICAL
Рет қаралды 80 М.
What is a CT Burden ? Explained | TheElectricalGuy
11:59
Gaurav J - TheElectricalGuy
Рет қаралды 13 М.
Stability test of Transformer || Hindi
23:01
Insight Tecs
Рет қаралды 54 М.
Current Transformers (CT)
14:31
Eaton
Рет қаралды 471 М.