cVEMP: An Introduction

  Рет қаралды 30,544

Interacoustics

Interacoustics

Күн бұрын

Пікірлер: 16
@ott2732
@ott2732 4 ай бұрын
You’re helping me so much with your videos!
@InteracousticsTV
@InteracousticsTV 4 ай бұрын
Glad to hear they can be of use! ☺
@monikalamanda3864
@monikalamanda3864 Жыл бұрын
This is a very great video to understand c-VEMP, thankyou so much
@InteracousticsTV
@InteracousticsTV Жыл бұрын
Thanks Monik, glad you enjoyed it :)
@taimasalem2558
@taimasalem2558 5 жыл бұрын
I want to ask if functional head impulse device available in interacoustics and how much it cost???
@MukeshKumar-py9sv
@MukeshKumar-py9sv 3 жыл бұрын
What do you mean by recording window ? and what is the scale to know that patient is contacting muscle sufficiently (Video 25:50)?
@ЕкатеринаСеливерстова-ч2ш
@ЕкатеринаСеливерстова-ч2ш 5 жыл бұрын
You placed the reference electrodes on the SCM? Is that correct?
@InteracousticsTV
@InteracousticsTV 5 жыл бұрын
Thank you for your question. For cVEMP measurement the Interacoustics Eclipse system uses the RIGHT and LEFT reference electrode sites to measure both the EMG activity of the SCM, and the myogenic response triggered by the stimulus activiating the VCR. The active electrode is placed on the sternoclavicular joint, and is used for both the RIGHT and LEFT measurements.
@davewalker8394
@davewalker8394 4 жыл бұрын
@@InteracousticsTV Sorry to disagree. In electroneurodiagnostics the convention is the active electrode would be the place you want to record a response from, this test would be the LSCM + RSCM. The reference electrode would be an area near but less active than the active recording electrode, this test would the clavicular joint.
@مريمالمطيري-م7ح
@مريمالمطيري-م7ح 3 жыл бұрын
What type of electrode used???
@InteracousticsTV
@InteracousticsTV 3 жыл бұрын
Hi! Ambu Neuroline 720: www.sanibelsupply.eu/ambur-neurolinetm-720-electrodes-25-pcs Best regards, Shane
@bharathkadiriaudiologist8248
@bharathkadiriaudiologist8248 3 жыл бұрын
Sir what is the normal amplitude ratio
@InteracousticsTV
@InteracousticsTV 3 жыл бұрын
Hi Bharath, I recommend reading section 6.2 in this paper: www.sciencedirect.com/science/article/pii/S2467981X19300095 Best regards, Shane
@bharathkadiriaudiologist8248
@bharathkadiriaudiologist8248 3 жыл бұрын
@@InteracousticsTV sir that is a asymmetric ratio up to 35 it's normal but I want a rectified amplitude muvolts like I will share you the screen
@bharathkadiriaudiologist8248
@bharathkadiriaudiologist8248 3 жыл бұрын
Please provide your what's app number I will share you my???
@InteracousticsTV
@InteracousticsTV 3 жыл бұрын
@@bharathkadiriaudiologist8248 Write to me at ssei@interacoustics.com, then I can forward your question to one of our in-house audiologists :) Best, Shane
Masking the ABR (1/2): Introduction to Masking
26:28
Interacoustics
Рет қаралды 20 М.
oVEMP: An Introduction
52:11
Interacoustics
Рет қаралды 9 М.
How to treat Acne💉
00:31
ISSEI / いっせい
Рет қаралды 108 МЛН
Enceinte et en Bazard: Les Chroniques du Nettoyage ! 🚽✨
00:21
Two More French
Рет қаралды 42 МЛН
coco在求救? #小丑 #天使 #shorts
00:29
好人小丑
Рет қаралды 120 МЛН
Introduction to Vestibualar Evoked Myogenic Potentials VEMP   SHAA 2017 pds
16:12
e3 Med-Acoustics, Inc.
Рет қаралды 8 М.
Oculomotor Testing: Theoretical Introduction
28:41
Interacoustics
Рет қаралды 8 М.
Auditory Steady State Response: An Introduction
44:41
Interacoustics
Рет қаралды 30 М.
Rotary Chair Testing: An Introduction (2/3)
27:44
Interacoustics
Рет қаралды 14 М.
Introduction to the CE-Chirp® Stimuli
23:36
Interacoustics
Рет қаралды 13 М.
Vestibular Testing: Calorics, Rotational Chair and vHIT
26:13
Interacoustics
Рет қаралды 14 М.
Tympanograms: An Introduction
32:35
Interacoustics
Рет қаралды 33 М.
Acoustic Reflexes: An Introduction
30:13
Interacoustics
Рет қаралды 62 М.
Otoacoustic Emissions (OAEs): An Introduction
29:57
Interacoustics
Рет қаралды 61 М.
Caloric Test: Testing and Analysis
50:24
Interacoustics
Рет қаралды 31 М.
How to treat Acne💉
00:31
ISSEI / いっせい
Рет қаралды 108 МЛН