Data Center HVAC - Cooling systems cfd

  Рет қаралды 356,835

The Engineering Mindset

The Engineering Mindset

6 жыл бұрын

Data Center HVAC cooling systems. In this video, we look at data center HVAC designs with a focus on the cooling systems and air management strategies used, as well as design analysis with Computational Fluid Dynamics (CFD) on SimScale (www.simscale.com/). We cover raised floor, hot and cold aisle, hot aisle containment, cold aisle containment, CFD simulations, CRAC units, heat exchangers, chillers, free cooling, water and air cooled chillers as well as cooling towers.
🏆🏆🏆 Create a free SimScale account to test the cloud-based simulation platform here: www.simscale.com/
LEARN MORE HERE: theengineeringmindset.com/dat...
Sign up for our FREE engineers newsletter for updates, competitions, news and offers
🎁 Link: engmind.info/Engineers-Report
With 100,000 users worldwide, SimScale is a revolutionary cloud-based CAE platform that gives instant access to CFD and FEA simulation technology for quick and easy virtual testing, comparison and optimization of designs in several industries, including HVAC, AEC, and electronics.
Discover more than 50 free on-demand webinars on different topics, from ventilation or data center design and wind load analysis to aerospace, F1, and sports aerodynamics here: www.simscale.com/webinars-wor...
Read more about the benefits of using cloud-based engineering simulation and the SimScale Community here: www.simscale.com/product/pricing
Find thousands of ready-to-use simulation templates created by SimScale's users which you can copy and modify for your own analysis: www.simscale.com/projects/
Read this article on "How to Design Data Center Cooling Systems and Ensure Compliance with ASHRAE 90.4: www.simscale.com/blog/2018/02...
⚡🛠️ TOOLS YOU NEED 🛠️⚡
**************************************
Get this HVACR book ➡️ amzn.to/3XFCaKC
Professional Multimeter -➡️ amzn.to/3xu2Vaw
Good multimeter -➡️ amzn.to/3xrbuTd
Professional clamp meter ➡️ amzn.to/4140FnK
Good Clamp meter ➡️ amzn.to/3xqt2is
Outlet tester ➡️- amzn.to/3kavg2l
Energy monitoring plug ➡️ amzn.to/3SkfPl7
Battery tester -➡️ amzn.to/3S3fHWI
Basic electronics kit ➡️ amzn.to/3xuLiqS
MY FAVOURITE GEAR
🎥 My camera - amzn.to/3YCZ7Q9
🎤 My Microphone - amzn.to/3YYXsUC
⌨️ My Keyboard - amzn.to/3lBsl33
🖥️ My monitor - amzn.to/415BGjW
🎧 My headphones - amzn.to/3lN7R7u
😎 Get your Engineers T-shirts, Hoodies, Cups & stickers here:
*******************************
goo.gl/M1PGrx
☕ Buy Paul a coffee to say thanks
*******************************
⚠️ Found this video super useful? Buy Paul a coffee to say thanks: ☕
PayPal: www.paypal.me/TheEngineerinMi...
🙏 Support us on Patreon
*******************************
/ theengineeringmindset
🕵️ Check out our website!
*******************************
TheEngineeringMindset.com
👥 Socialise with us
*******************************
FACEBOOK: / theengineeringmindset
TWITTER: / theengmindset
Instagram: / engineeringmindset
Google+: www.google.com/+Theengineering...
KZbin: / theengineeringmindset
👀 Links - MUST WATCH!! 👀
*******************************
⚡⚡⚡ELECTRICAL ENGINEERING⚡⚡⚡
👉How electricity works: • How ELECTRICITY works ...
👉Three Phase Electricity: • How Three Phase Electr...
👉How Inverters work: • How Inverters Work - W...
👉How TRANSFORMER works: • How does a Transformer...
👉How 3 Phase electricity works: • How Three Phase Electr...
👉How Induction motor works: • How does an Induction ...
How water cooled chiller works Prt1 - • Chiller Basics - How t...
How water cooled chiller works Prt2 - • Chiller Basics - How t...
How Air cooled chiller works - • Absorption Chiller, Ho...
How Absorption Chiller works - • Air Cooled Chiller - ...
How Heat Pump works: • How A Heat Pump Works ...
Primary & Secondary system: • HVAC Primary & seconda...
Fan Coil Units: • Fan Coil Unit - FCU HVAC
VAV Systems: • Variable Air Volume - ...
CAV Systems: • Constant Air Volume - ...
VRF Units: • Video
HVAC Basics: • Fundamentals of HVAC -...
Heat Exchangers: • Plate Heat Exchanger, ...
Pumps: • Centrifugal Pump How D...
How a Chiller, Cooling Tower and Air Handling Unit work together - • How a Chiller, Cooling...
#HVAC #refrigeration #engineering

Пікірлер: 83
@EngineeringMindset
@EngineeringMindset 6 жыл бұрын
⚠️ *Found this video super useful?* Buy Paul a coffee to say thanks: ☕ PayPal: www.paypal.me/TheEngineerinMindset
@user-bo1ji3pc5c
@user-bo1ji3pc5c 3 жыл бұрын
@Love BLANEY قرقرسصيسذفضضف١
@ericknebel5905
@ericknebel5905 6 жыл бұрын
Loved it. I'm part of the DDC division of an HVAC company, and I want to thank you for all the informative videos that keep me learning, but also helped me get the job. Currently I am working on a 1,000,000 sq ft data center project that is truly a feat of engineering. Love my job. Thanks, again. Eric
@javalearner4227
@javalearner4227 3 жыл бұрын
Hi Eric, I am looking for job in data center as ME engineer. Could you please guide me which skills should I focus on ? Currently, I am learning REVIT and have done analysis in CFD.
@maheshmurali2697
@maheshmurali2697 3 жыл бұрын
@@javalearner4227 Hi I'm a Dceo operations engineer and did Mechanical engineering. You need to have good knowledge in HVAC, Fire fighting and electrical systems.
@smily2208
@smily2208 5 жыл бұрын
I do this everyday this video is spot on great job you deserve my thumbs up
@kasimshaikh3750
@kasimshaikh3750 3 жыл бұрын
I work at JLL in facilities management your videos are really helpful.
@kimberlysulit220
@kimberlysulit220 4 жыл бұрын
This is helpful for my architectural thesis, thanks.
@EngineeringMindset
@EngineeringMindset 5 жыл бұрын
⚠️ Learn how *AIR HANDLING UNITS* work here: kzbin.info/www/bejne/gXTMp2t_drqenpo ⚠️
@rock3tcatU233
@rock3tcatU233 5 жыл бұрын
I've never subscribed to a channel so quickly, finally I've found some quality MechE content on YT. Could you also do a series on semiconductor cleanroom engineering?
@WarHammer1989
@WarHammer1989 5 жыл бұрын
I work on this stuff near daily, but I just started a month ago. This is very helpful!
@dylanrodriguez7129
@dylanrodriguez7129 3 жыл бұрын
What type of back ground do you need to pass ? Squeaky clean or your allowed a misdemeanor like a DUi
@bobbyBoosh
@bobbyBoosh Ай бұрын
I just had a company reach out about a job opportunity for Data center hvac. Worth it??
@intjonmiller
@intjonmiller 6 жыл бұрын
In 2004 I worked in a sign shop that had been built to be a data center but which never took occupancy when the Dotcom bubble burst. The only climate control they had installed was a massive AC unit like these CRAC units, but which didn't have a controller. It was either on or off. In 20-30 minutes it dropped the temperature from about 85°F to 50-55°F. And while it was running it was deafening. But we only had to run it twice a day during the hottest part of the year.
@jonathanhernandez348
@jonathanhernandez348 6 жыл бұрын
Awesome video and very well put together. I currently work in constructing data centers and this video is perfect for anyone who wants to learn how this building gets cooled. I hope to see more videos coming from you explaining the electrical side such as how the power gets distributed from transformers to generators to Ups,PDU’s etc.
@innocentnwachukwu918
@innocentnwachukwu918 2 жыл бұрын
This is an awesome video. Thank you so much for putting this together. It is very helpful.
@PapaWheelie1
@PapaWheelie1 6 жыл бұрын
Probably the coolest video on data center environmental design
@EngineeringMindset
@EngineeringMindset 6 жыл бұрын
well played pun
@PapaWheelie1
@PapaWheelie1 6 жыл бұрын
The Engineering Mindset - I work in a small tech center and we don’t use under the floor forced air cooling because it requires plenum rated wire that is much higher $$
@PapaWheelie1
@PapaWheelie1 6 жыл бұрын
So we have to have the supply and returns in the drop ceiling- cold supplies in front of the racks and returns behind. Not nearly as efficient as supply below the floors. And some of the equipment pulls from the rear.
@EngineeringMindset
@EngineeringMindset 6 жыл бұрын
Sounds like some CFD sims could help you prove the business case to invest in improved cooling!
@andyhill242
@andyhill242 3 жыл бұрын
This video is particularly applicable to me. Modern HPC clusters often have power consumption in the MW range and often uses liquid cooling for CPUs GPUs and RAM, these usually consist of a local liquid loop with a heat exchanger linked to a secondary loop fed from the building chilled water system.
@JasonRichardsone
@JasonRichardsone Жыл бұрын
One work exceptional - thank you
@hayel2015
@hayel2015 6 жыл бұрын
Great work done well
@talonwilliams6148
@talonwilliams6148 Жыл бұрын
Your content is so touching
@hoshwagan4199
@hoshwagan4199 4 жыл бұрын
I found it realy helpful.
@jakovbilic4556
@jakovbilic4556 2 жыл бұрын
Wow, great work!!
@haisridhar10
@haisridhar10 6 жыл бұрын
good explanation..
@richardwager283
@richardwager283 3 жыл бұрын
Would be good to see a video on static transfer switches 👍🏻
@thinkandquestion1305
@thinkandquestion1305 Жыл бұрын
Great information. Thank you
@IngDzib
@IngDzib 2 жыл бұрын
Thank you Paul!
@apokalypz08
@apokalypz08 3 жыл бұрын
Side note, if the CRAC unit is using chilled water then it's typically called a CRAH (computer room air handling) unit. This is due to not having the compressor or majority of the work to cool being actually IN the unit like it is with a CRAC unit. With CRAH's the compressor doing the most work is typically in the upstream chiller or heat rejection equipment of similar type and function.
@DuffsterZ
@DuffsterZ Жыл бұрын
Nicely explained-
@OthmanAlikhan
@OthmanAlikhan 2 жыл бұрын
Thanks for the video =)
@ahmadsurkanicks8345
@ahmadsurkanicks8345 4 жыл бұрын
I just knew the hot isle containment.. 👍👍
@sorosekaewmanee1845
@sorosekaewmanee1845 3 жыл бұрын
Very good video
@kyoukohaha
@kyoukohaha 6 ай бұрын
Awesome!
@samuelfrondozojr.1273
@samuelfrondozojr.1273 3 жыл бұрын
You have good application of Air conditioning systemapplied to all type of Area of location in a residential or commercial building.
@ryanellinger103
@ryanellinger103 4 жыл бұрын
This is a cool video, but I work for a big commercial refrigeration and HVAC company in Arizona. I have never seen this. We do all the work for Century link in Arizona. They only use chillers or rtus. I’m not saying this doesn’t happen, but I think with all the bad airflow just use a chiller with multiple air handlers. Thanks for the video.
@STDrepository
@STDrepository 6 жыл бұрын
PLEASE TALK ABOUT HVAC SYSTEMS ON NAVY SHIPS
@bidav2114
@bidav2114 Жыл бұрын
If he knows about that he will do it.
@philipmungai9070
@philipmungai9070 3 жыл бұрын
Nice video
@ajithkumarsarathy8732
@ajithkumarsarathy8732 4 жыл бұрын
Can you explain about relative humidity. Why it is important in precision AC and data center
@fayzankhan1781
@fayzankhan1781 6 жыл бұрын
What standard is used for hydrotesting of chilled water pipes?
@snkrmindset93
@snkrmindset93 4 жыл бұрын
I'd like to know how fire suppression nozzle will be placed if there will be a ductwork for hot aisle containtment system?
@mahdi.shahsavari
@mahdi.shahsavari 5 жыл бұрын
Thank you sir. 1. Are data center can work on partial load like residential unit? Are there any load variations on a server room? 2. In free cooling method without plate heat exchanger, is there any limitation for moisture for electronic devices?
@markarca6360
@markarca6360 3 жыл бұрын
This is also called CRAC (Computer Room Airconditioning) units.
@asifhussain3032
@asifhussain3032 2 жыл бұрын
Sir, you are explaining in much easier way but can you please explain what is basic of data center after that this critical one
@akshaykorlekar
@akshaykorlekar 2 жыл бұрын
Thanks
@EngineeringMindset
@EngineeringMindset 2 жыл бұрын
Thank you!
@nileshgaikwad6707
@nileshgaikwad6707 4 жыл бұрын
Please make video on immersion cooling data center technology.
@zuberkhan8560
@zuberkhan8560 2 жыл бұрын
Can you please help us to understand the effect of unfiltered or generated gases due to heat..what are the effects and how can we tackle the issue..
@RD-lf3pt
@RD-lf3pt 4 жыл бұрын
May you share the Simscale design? :D
@brentwilliams191
@brentwilliams191 3 жыл бұрын
I find it funny that HVAC is for Aircons, where its been a very long Time the means of "High Voltage Alternating Current".
@ecantil2267
@ecantil2267 3 жыл бұрын
With regards to the DC Energy Consumption ratio: I think its best to allocate 50% of power on HVAC and 36% on IT Equipment (10% on Network Devices and 26% on Server and Storage).
@mariacisni3212
@mariacisni3212 2 жыл бұрын
I think if that's the case, the PUE will decrease
@vijayme123able
@vijayme123able 4 жыл бұрын
Good explanation Paul, Can you make more videos on Data center or can suggest KZbin channel which offers good learning for HVAC design in Data center w.r.t uptime or TIA tier certification
@EngineeringMindset
@EngineeringMindset 4 жыл бұрын
Thank you. I've been planing to do a video on CRAC units for a while, maybe evaporative coolers too. I think next month we'll publish a video about some colling components inside a CRAC unit so we can tie that in to data centres
@TGmirul
@TGmirul 3 жыл бұрын
Hey, im currently working on my assignment data center. Does anyone know how to select diffuser for floor raised.
@connorwatson7162
@connorwatson7162 4 жыл бұрын
What are the sources for this video so I can do more research?
@so8up839
@so8up839 3 жыл бұрын
what the best hvac system design for data center
@AKK105
@AKK105 Жыл бұрын
why there are gas pipes for the outdoor unit of a water-cooled in-row unit?
@user-le3tz7mf4k
@user-le3tz7mf4k 3 жыл бұрын
👍👍👍
@ask4george1
@ask4george1 4 жыл бұрын
Data centers are always expanding, they often don't take into consideration the added heat load. They just keep pushing in more racks. One solution was a manifold piping system over head, with quick connects. You just place fan unit cooler on top of the new data rack and hook up the quick connect flexible refrigeration lines that's it. The main cooling unit has a large reservoir to accommodate multiple fan units. It was years ago when I helped install the manifold piping system, and I can't remember what it was called. Maybe someone knows the system name.
@SH-ex6wj
@SH-ex6wj 4 жыл бұрын
Can you provide me ppt presentation for like this without voice for 2 different topics?
@canudigitsucka007
@canudigitsucka007 5 жыл бұрын
Hey Paul, the VRF video is missing. Can you upload this one again?
@EngineeringMindset
@EngineeringMindset 2 жыл бұрын
New VRF unit video here:➡️ kzbin.info/www/bejne/apqUiZqZhZano9k
@mustafaahmed5187
@mustafaahmed5187 4 жыл бұрын
can i get HAP file for these room ?
@AjayKumar-ct6ok
@AjayKumar-ct6ok 2 жыл бұрын
Dear sir please. Make a video all in hindi ....
@Matt-rx4pm
@Matt-rx4pm Жыл бұрын
Great video! I don't know if I am the first to nerd out on this video and pick it apart like a troll, but you incorrectly call a computer room cooling unit (@10m:44s) connected to chilled water system a CRAC but its actual a CRAU (Computer Room Air Handling Unit). There is no AC (Air Conditioning) when using a chiller so I get it and using the term "Crack" is a generalization. If I am building a project and we have chilled or condenser water in the computer room I start to worry about a new set of issues, computer and water don't mix.
@exterminator4808
@exterminator4808 3 жыл бұрын
What you described as a 'CRAC' unit is actually a 'CRAH' unit.
@smokeysmith1282
@smokeysmith1282 2 жыл бұрын
Depends however on the location of the mechanical cooling equipment. CRAC units include the mechanical cooling system at each unit. CRAHUs are chill water fan systems and rely on remote Chillers type systems.
@S-khalil
@S-khalil 4 жыл бұрын
The picture at 0:17 is not a recommended way for stacking racks, it should be like Cold-Cold front or hot-hot front.
@coreyhansen2852
@coreyhansen2852 4 жыл бұрын
He addresses this specifically at 4:00.
@STEINYY
@STEINYY 3 жыл бұрын
Why cant I see the VRF video? It's not available does it say..
@EngineeringMindset
@EngineeringMindset 3 жыл бұрын
Was deleted. Check our supermarket hvac video for vrf basics
@STEINYY
@STEINYY 3 жыл бұрын
@@EngineeringMindset aright will do so, thx!
@EngineeringMindset
@EngineeringMindset 2 жыл бұрын
New VRF unit video here:➡️ kzbin.info/www/bejne/apqUiZqZhZano9k
@imacgra1
@imacgra1 8 ай бұрын
And you forgot the platform that everyone who watch this video definitely uses KZbin 0:37
@asemahmed2618
@asemahmed2618 2 жыл бұрын
I hope you put an Arabic language as translation
@---wl3bi
@---wl3bi 4 жыл бұрын
versatemp in a data centre, not very efficient
@cmj13
@cmj13 2 жыл бұрын
You are too fast in explanation, otherwise it is good !
@gg-gn3re
@gg-gn3re 3 жыл бұрын
All of these are junk. I run several crappy black pipes 7ft under ground for 200ft and pump in 48F air into my greenhouse and room year around. Can't get more efficient than 1 fan.
Fan Coil Unit  - FCU HVAC
13:19
The Engineering Mindset
Рет қаралды 700 М.
Data Center HVAC Systems
20:14
MEP Academy
Рет қаралды 96 М.
1🥺🎉 #thankyou
00:29
はじめしゃちょー(hajime)
Рет қаралды 79 МЛН
🍟Best French Fries Homemade #cooking #shorts
00:42
BANKII
Рет қаралды 48 МЛН
Pray For Palestine 😢🇵🇸|
00:23
Ak Ultra
Рет қаралды 36 МЛН
A DAY in the LIFE of the DATA CENTRE | GENERATOR TESTING with ASH!
12:52
Custodian Data Centres
Рет қаралды 248 М.
Google Data Center Security: 6 Layers Deep
6:10
Google Cloud Tech
Рет қаралды 8 МЛН
Data Center Cooling - how are data centre cooled cold aisle containment hvacr
10:25
The Engineering Mindset
Рет қаралды 283 М.
Inside a Google data center
5:28
Google Workspace
Рет қаралды 21 МЛН
HVAC Training - Basics of HVAC
10:21
Price Industries
Рет қаралды 1,9 МЛН
Fundamentals of Data Center Cooling | Data Center Cooling Strategies
15:19
GogoTraining - PeopleCert Accredited (ATO)
Рет қаралды 7 М.
1🥺🎉 #thankyou
00:29
はじめしゃちょー(hajime)
Рет қаралды 79 МЛН