A Very Big Thank you - enjoyed the step-by-step Installation- I'm installing 2 lights, first with-in the Acorn & the 2nd in the return. I up the breaker from 35 to 50 and using 2 Transformer for the UV Balesters.
@jnava556710 ай бұрын
Thanks for the great step by step video, but I have one question. In the secondary wires, is there a hot or it can be connected to any wires on the light fixture wires.
@aho966411 ай бұрын
Good video bro i have to of them in my AC. One in the air handler and one in the duck work
@DeaninItYourself11 ай бұрын
Nice 👍
@miguelangelgonzalezcanas71774 ай бұрын
did you use 2 transformers?
@cameronharris28624 ай бұрын
can I use the same 24v wires that go to my humidistat and splice? Or do I need to add another transformer? Thanks
@DeaninItYourself4 ай бұрын
As long as there is not a big voltage drop you whould be fine. If not just add the transfomer
@Somethingtowatch20126 күн бұрын
Thank you for this video. I just installed this UV light and transformer that you used in your video. Should I be getting a strong odor when new? The transformer and control module were warm, the light was cool. Seems normal. If anyone can help answer this question it would be appreciated.
@DeaninItYourself2 күн бұрын
you sometimes get an odor initially
@miguelangelgonzalezcanas71774 ай бұрын
Hi, If you want 2 lights, one above and one below the coils? do you need 2 separate transformers, one for each light?
@DeaninItYourself4 ай бұрын
One transformer should be good
@ammonbennion46383 күн бұрын
My UV light has a ground wire as well. Do I just ground it to the metal somewhere in the unit? Also, does it matter where each wire(hot and neutral) connect after the transformer? The video doesn’t specify.
@DeaninItYourself2 күн бұрын
where is the ground wire. By the part that connects to the transformer?
@josephli72606 ай бұрын
Im trying to install 3 lights into my unit. Do you need a separate transformer for each light?
@DeaninItYourself5 ай бұрын
no
@derrickgray31147 ай бұрын
Installed one at my customers home with similar setup as you had to remove because the ac filter lights up blue from the reflection off coil
@lindenjohnson51118 ай бұрын
Thank you so very much
@DeaninItYourself8 ай бұрын
You are so welcome
@pukabouy13 ай бұрын
Recommend adding note (and product link) about UV safety glasses around these lights.
@DeaninItYourself3 ай бұрын
👍
@jessikat66927 ай бұрын
My Carrier Unit is a 208/230. Which Wires do I use?
@DeaninItYourself7 ай бұрын
Red and white. Use the one for 208
@jessikat66927 ай бұрын
@@DeaninItYourself Thank you.
@bactran37144 ай бұрын
By wiring the transformer directly to the power in, do you intend to let the UV light being ON all the times even when the thermostat sends the signal to turn off the system, is it correct? If so, will the UV light have a shorter life?
@DeaninItYourself4 ай бұрын
yes that is correct
@DCINTEXAS7 ай бұрын
I am thinking of installing an HVAC UV light inside my supply duct in front of the coil. However, my supply duct has some type of thick black insulation inside of it. I am concerned this insulation might degrade over time due to the UV light. Also, I was wondering if it's OK for hot air (when heater is running) to run while the UV lights are on. Thank you.
@DeaninItYourself7 ай бұрын
Yes the hot air running is fine. The UV lights are designed for this. As far as the insulation goes , I am not sure about this.
@antok869 ай бұрын
What model air handler is that? Mine has 230v
@DeaninItYourself9 ай бұрын
its a carrier
@antok869 ай бұрын
@@DeaninItYourselfmy carrier unit has an existing 24v transformer can’t I just tap into that?
@neonnight346098 ай бұрын
@@DeaninItYourselfI also have the same question. If my unit has 24 volts can I tap into that?
@EduardoFuentesLeal7 ай бұрын
230 use the 240v cable
@antok865 ай бұрын
@@neonnight34609still tryna find this out my lf
@Alexsjusa8 ай бұрын
Well what a surprise I’m looking into UV lights and if I should keep my UV light from my unit I’m about to replace. I remember you, Steven’s friend! How much are those bulbs. My AC company is saying they are about $400. How much is the entire system?
@DeaninItYourself7 ай бұрын
you can get them on Amazon for around $100 or less
@Alexsjusa6 ай бұрын
@@DeaninItYourself they ‘threw in’ a new system for an extra hundred dollars. There are 2 lights so I’ll see how it goes
@dcs45554 ай бұрын
now you have installed that at the back of the plenum. and the wire goes through a hole with no cable protection. jeez you seem very confident though, i agree on your intentions. just please let everyone else know this is not the best way to install it. i haven't even installed mine, but wanted to know how/why the magnet, and where. now i see how the supplier intended it to mount. and i don't have a metal duct, i have that sheetboard of insulation. so i'm still working it out. as always, just mho
@dcs45554 ай бұрын
ok i guess that was premature. now i think this device just uses the magnet for a metal plenum. but the bracket has mounted studs, with thumb nuts (i hope that makes sense) for the actual BULB mount. and the magnet is for a metal plenum. i will probably use a metal square to sandwich on the fiberboard insulation. but the 24 transformer - i hope to not need. according to my hvac paperwork- i should be able to use the inside blower circuit. i may be wrong! lol but so far my plans are to go with the 24v common (denoted "C" wtf - online says blue/black/brown/purple) and cool stage 1 (yellow). so we'll see i guess. that should make it light up only when the indoor fan is running. but i did not look into the max current for the hvac 24v circuit. so that might be a prob. just mho
@robertmcmahon27443 күн бұрын
Ca you use an air ionizer at the air intake while using the UV light within the a- coil plenum without any problems?? Will the ionizer damage or effect the UV light's operations.??
@ApothercyCold2 ай бұрын
Seems like you'd be better off wiring it to power on with the unit. Or, do it this way but utilize something like a Shelly to have it power on (via Home Assistant or something) only when running.
@DeaninItYourself2 ай бұрын
That could be an option as well
@NikoGoXrazy2 ай бұрын
I wouldn’t put it under the coil.
@DeaninItYourself2 ай бұрын
why not
@NikoGoXrazy2 ай бұрын
@@DeaninItYourself does the sweat/condensation falling on it mess with it at all?
@disdatndaothaguy743611 ай бұрын
Are you building your home into a smart home?
@DeaninItYourself11 ай бұрын
Yes my house has a ton of smart features
@clintgray16236 ай бұрын
Drill the hole bigger and screw it in from the front, lots easier access
@malcolden77883 ай бұрын
Also why is the magnet placed on the back wall instead of the front wall? Less wire exposed inside by placing it on the opposite side.
@bangolufsen8687Ай бұрын
it's a shame the thousands of dollars cabinets- do not have this implemented to add them later. it's retarded on how they force people to manage in adding those optional things - sloppy cabling and connections. sad.
@DeaninItYourselfАй бұрын
I agree
@ivibzmussrichent13 күн бұрын
This comment hurts my head, what are you saying bro???????