Lead Mains Water Pipe Replacement With 25mm MDPE

  Рет қаралды 12,301

denbydish

denbydish

Күн бұрын

Пікірлер: 22
@NAFO_Badger_Brigade
@NAFO_Badger_Brigade 4 ай бұрын
Gotta do this job later in the year!! Checking for handy tips! The twinwall pipe makes sense!
@suvvx900
@suvvx900 Жыл бұрын
Quality work! Currently doing the same job and this is a very useful guide.
@dembydish
@dembydish Жыл бұрын
Thanks for your comment and I'm glad I could help. If you feel inclined please subscribe.
@stuartandrews4344
@stuartandrews4344 Жыл бұрын
Great job, sensible to use 25mm MDPE, too many peeps would use the 20mm pipe for such a short distance. Some water companies allow you to use 32mm MDPE instead of 25mm, great if you have good mains pressure & Twinwall Ducting End Caps are readily available.
@dembydish
@dembydish Жыл бұрын
Hi Stuart, interestingly I asked our local water company about using 32mm and they said they only use 25mm to the meter. I assumed at that point the larger MDPE was possibly a bit redundant? But I'm not sure to be honest. Many thanks for taking the time to comment. Keep well.
@blastfromthepastism
@blastfromthepastism 11 ай бұрын
Great video and some great workmanship 👌 Thanks for sharing 😊
@dembydish
@dembydish 11 ай бұрын
You are very welcome. Thank you for your comment and if you feel inclined please subscribe. Have a great new year.
@NAFO_Badger_Brigade
@NAFO_Badger_Brigade 4 ай бұрын
Love the home made core drill! Did you use anything to check for hidden cables etc or just take it steady?
@dembydish
@dembydish 4 ай бұрын
Good morning. I rewired my home so I was aware of the location of the service entrance cables. Otherwise, I would have checked first. Always a good idea to verify these things for any home owner. Thank you for your comment and please subscribe if you feel inclined.
@SuspiciousPixels
@SuspiciousPixels 5 ай бұрын
Great job, what's your dynamic pressure before and after the work?
@dembydish
@dembydish 5 ай бұрын
I forgot to measure it with a pressure gauge, but it was noticeably better. I was more concerned that it is up to spec and will last me out and I got rid of the lead. There's peace of mind especially as the pipe runs under the driveway (which is now finished!) Thank you for your kind comment.
@SuspiciousPixels
@SuspiciousPixels 5 ай бұрын
@@dembydish That's great. United Utilities regs are different for my area in the NW, they recommend 100mm ducting, whereas I think you used 55mm. I bought 110mm Twinwall ducting and for the end caps I bought Multikwik Drain & Waste Adaptor MKUAB 2283. There are different brands that make exactly the same thing and even some in B&Q but basically its a rubber soil waste reducer cap which I can cut a cross section to feed the mains 25mm MDPE pipe snugly through. I got my caps of ebay, £10 for a pack of 2.
@BillTangy
@BillTangy Жыл бұрын
What happens if the don't find lead their end? If the don't change to bigger diameter I'm guessing your flow would remain the same?
@dembydish
@dembydish Жыл бұрын
Hi Bill, when they came to dig up the pavement to connect my mdpe pipe to the meter, they discovered that their feed pipe to the meter had already been changed to 25mm mdpe. I admit this was a bit disappointing. However, just replacing the lead from meter to house did improve the flow to a degree, not massively but observable. The area where I live does not have high water pressure, but I've managed to achieve the best results available to me and the pipe is now up to code and good for years to come. I could make another video on trying to organise the connection and the chaos that followed! Thanks for your comment. Please subscribe.
@Aliens4world
@Aliens4world 9 ай бұрын
@@dembydishdid u still need water pump? Can this pump be installed on 15mm main pipe?
@dembydish
@dembydish 9 ай бұрын
@@Aliens4world Hello, yes I still use the pump which has a maximum fixed output of 10 liters per minute (if memory serves). This is better than what the water mains provides otherwise it wouldn't switch on. The pump comes with adapters so it can be attached to 15 or 22 mm copper pipe. Hope this helps and please subscribe. Thanks for your comment.
8 ай бұрын
What size is the corrugated conduit and the insulation ?
@RAGINGDRAGON99
@RAGINGDRAGON99 6 ай бұрын
What twinwall ducting is that? I bought rigiduct, but it has no flexibility at all.
@UKsystems
@UKsystems 3 ай бұрын
I’m not being funny it’s kind of in the name
@Cheomega
@Cheomega 10 ай бұрын
Should’ve used 32mm black poly propylene for underground water supply that will last for ever, while high density polyethylene is used for inside the house
@NAFO_Badger_Brigade
@NAFO_Badger_Brigade 4 ай бұрын
I thought the same - though wonder whether there is a difference in real terms?
@UKsystems
@UKsystems 3 ай бұрын
Black pipe is not appropriately coloured for this use and this one will last good enough plastic pipe should not be there for ever as it will start breaking down into the water
Replacing lead water mains
14:29
Office Boy Builder
Рет қаралды 96 М.
Replacing Lead Mains Water Pipe - DIY Vlog #2
24:49
LCW DIY
Рет қаралды 131 М.
This Game Is Wild...
00:19
MrBeast
Рет қаралды 194 МЛН
If people acted like cats 🙀😹 LeoNata family #shorts
00:22
LeoNata Family
Рет қаралды 29 МЛН
DIY Lead Water Main Replacement with 25mm MDPE (Alkathene pipe) #53
30:32
Renovating Vane Cottage - DIY House Renovation
Рет қаралды 2,7 М.
MDPE MAINS WATER PIPE - ATPLAS CHAMBER - Plumbing Tips
12:01
plumberparts
Рет қаралды 266 М.
How To Know If You Have A Lead Water Pipe
5:35
City of Hamilton
Рет қаралды 88 М.
How to install a new water main line and shut off valve
18:35
Budget Plants
Рет қаралды 150 М.
Installing and Connecting new Water Mains - DIY
16:54
The Restoration Couple
Рет қаралды 252 М.
Lead Service Line Replacement
28:32
BuildingWisconsinTV
Рет қаралды 14 М.
MDPE to Copper Pipe - Stopcock - Water Connection
14:38
The Aiden Project🔨
Рет қаралды 29 М.
How To Fix Your Low Water Pressure Problem
16:08
Skill Builder
Рет қаралды 959 М.
This Game Is Wild...
00:19
MrBeast
Рет қаралды 194 МЛН