Thank you for the Video, Now cantilever slab design become very easy🙏
@skillrachnainstituteoftech58444 жыл бұрын
Thank you for your words
@jagadeeshamjuri79072 жыл бұрын
Please make video on beams also... We learn so much from your videos
@trojan-v6u2 жыл бұрын
Neat and clean, very good indeed.
@idealonlineservicecentre5503 Жыл бұрын
Excellent
@jagadeeshamjuri79072 жыл бұрын
1st doubt is I have a doubt on structural design of cantilever slab.. My cantilever slab span by depth ratio is less than 2.. Now its considered two way slab then how can you show crank four sides?
@gajananmore74994 жыл бұрын
I really like this video
@skillrachnainstituteoftech58444 жыл бұрын
Thank you for your words ❤️
@jagadeeshamjuri79072 жыл бұрын
2nd doubt....The cantilever slab over all depth formula is span/10.. Here the span of slab is 3000mm.. So overall depth is 300mm… In practically is it possible to made 300mm concrete slab…?
@Khonkada6 ай бұрын
Is this cantilever slab just extended freely without any support below from beam at every joint? Please Answer 🙏
@skillrachnainstituteoftech58446 ай бұрын
Yes extended from beam.
@Khonkada6 ай бұрын
Thankyou Sir for your reply, My question was will this slab able to hold without Cantilever beam projecting outwards from main structure at column junction.for aesthetic Point of view. Please answer anytime🙏
@SuperChetanmore6 ай бұрын
It can be provided without beam too if load is less but generally need to provide appropriate with beam to counter the torsion and all other stresses.
@yogasan82314 жыл бұрын
Span by depth ratio for cantilever is 7 how you take 10
@skillrachnainstituteoftech58444 жыл бұрын
Dear the value 7 which you are stating as per IS 456:2000, section 23.2.1 is for effective depth not for overall depth. In this video we are learning about overall depth. I hope you got the clearity
@sanipanda90373 жыл бұрын
Any reference from any code as why you divided span with 10??
@skillrachnainstituteoftech58443 жыл бұрын
Not directly, on the bases of IS Code and practicing norms with enough safety factor, 10 value has been considered
@radicalexplorer36653 жыл бұрын
In floor finish PCC unit weight should be taken not RCC I think. Sir
@abdullahiahmedmohamed392525 күн бұрын
Sir in slab you only considered bottom cover, why you not considering top cover as well. Like 2(clear cover -0.5(dia of bar))
@SuperChetanmore25 күн бұрын
Because effective depth has been taken from the top of the slab to half the bottom diameter.
@abdullahiahmedmohamed392525 күн бұрын
@SuperChetanmore ok ok, so top cover is also included.