Really super bro thank you It came for 15 marks in today's SEM exam (osmania university) !
@Civillearningonline3 жыл бұрын
Best of luck 👍🙂👍👍
@Civillearningonline3 жыл бұрын
Punjab Technical University
@raushan95172 жыл бұрын
Thank you so much 🤗🤗 . Itna badhiya content dene ke liye....
@ayushgorana3 жыл бұрын
I see many lectures of civil engineering and all are good as your videos but one thing makes you different from them is that you answer and solve the all queries of students and while the other channels only answers 2 or 3 students queries
@Civillearningonline3 жыл бұрын
Thanks alot for your appreciation. I am trying my best. As much as i can.
@yogendrabajpai6750 Жыл бұрын
Well explained keep going like this
@sanjibsaha23153 жыл бұрын
As u had increase the diameter of the column as 420mm..so in case of finding out the 'Asc' why u considered the Ag as the older one. .
@nimapirhadi6135 Жыл бұрын
Thank you for this instructive video. May I know which standard is used for this design?
@Civillearningonline Жыл бұрын
Limit state method
@Kashur1.3 жыл бұрын
Use Hindi instead of getting disturbed bcz of English rest u r lit God bless you 🙏🏻
@Civillearningonline3 жыл бұрын
Yes, dear it's very much different in starting a conversation and speaking in front of camer. By the way it's improving day by day. Thanks for your compliment.
@anushkadeshmukh608712 күн бұрын
is this problem and solution is useful for b.arch students as well, or in b.arch there are different methods
@f4swfacebooktvshows549 Жыл бұрын
Helical reinforcement ka dia 8mm kyu liya ? 🥲 ussi ke liye to pura lucture dekha vo hi samjh nhi aaya
@rahulnagwanshi14924 жыл бұрын
A little more explanation is required basically in calculating pitch of helix...
@Civillearningonline4 жыл бұрын
Sure
@Civillearningonline4 жыл бұрын
Calculation of pich is as per the code is 456 2000. Of clause 39.4.1. page 71 and clause 26.5.3.2(d) page 49.
@jiteshmathur63394 жыл бұрын
Very helpful video.....please make one more on design of cantilever retaining wall by LSM.
@Civillearningonline4 жыл бұрын
Sure
@Civillearningonline4 жыл бұрын
Design of cantilever retaining wall kzbin.info/www/bejne/pn_aaGeuiMd-jMU
@hemanth._93 жыл бұрын
Pitch condition 2 is not satisfied ❌ See pitch is greater than 1/6 th of core dia
@nabinsah49573 жыл бұрын
Yes bhai. So we need to take intermediate value (i. E. Neither large nor smaller). Hope you got it. And thanks for your query.👍
@indiancreativity2159 Жыл бұрын
Dear formula of helical Vus/Vc
@reemsiddiqui07113 жыл бұрын
Sir which method is used in this numerical? My question is LSM or WSM?
@Civillearningonline3 жыл бұрын
It's LSM.
@reemsiddiqui07113 жыл бұрын
@@Civillearningonline Have you uploaded Circular Column Design using WSM?? In any other Video
@Civillearningonline3 жыл бұрын
Not yet. But I will.
@katlegoleboge33662 жыл бұрын
Do formulas differ for ..round axially column and rectangular axially column?
@Civillearningonline2 жыл бұрын
Yes
@seeratzainab38524 жыл бұрын
God bless U...
@Civillearningonline4 жыл бұрын
Thank you so much
@ammubabe277911 ай бұрын
Sir how do you take vhs/vc =0.009😢
@ammubabe277911 ай бұрын
Sir please answer
@Ram-ty6gu4 жыл бұрын
Sir Area of helix m to longitudinal reinforcement nhi subtract krte h na
@Civillearningonline4 жыл бұрын
Hello dear, We need to subtract the area of longitudinal reinforcement from the area of helix. It is because inorder to calculate the pitch of the helix we only need to have the area of helix reinforcement. And one thing more, We have considered the the diameter of helix after subtracting (2x40mm) cover from both sides. And u can notice in the inside the core dia. Longitudinal reinforcement is also included. And that's why we need to subtract the area of longitudinal reinforcement.so that the pich of core can be calculated and the codal provision is satisfied. I hope i met your confusion. Thanks for your comment. Have a nice day.
@kevintom3986 Жыл бұрын
Ath the minute 10.00 How the effective cover is 40
@Civillearningonline Жыл бұрын
As per IS code
@monicavaradharaj72014 жыл бұрын
Bro plse teach me structural engineering of rec beam for flexure by l.s.m ..please teach this unit bro
@Civillearningonline4 жыл бұрын
Sure
@mahammadyounus92952 жыл бұрын
Use full forms bro If use ast,as, these differ
@Civillearningonline2 жыл бұрын
Ok
@bhupeshchavan95972 жыл бұрын
Sir how to check what is find in numerical?
@Civillearningonline2 жыл бұрын
When you are asked to design then you need to calculate upto the lateral ties and some checks. Do as shown in this video. It's sufficient. Remember: design means calculation of reinforcement.
@bhupeshchavan95972 жыл бұрын
@@Civillearningonline thank you sir
@shelterforlife72612 жыл бұрын
Nepali boln aaudain hjr lai 😜
@Civillearningonline2 жыл бұрын
Aauxa hajur😅
@muzammilkhan30543 жыл бұрын
Is book ka name batao.
@Civillearningonline3 жыл бұрын
Reinforced concrete design by B. C. Punmia 🤘
@safdarkh7864 жыл бұрын
But 1.05 times means multiplied by 1.05, right?
@Civillearningonline4 жыл бұрын
Hello dear, First of all thanks for your comment. You are right that 1.05 times means multiply by 1.05. And when you come to read the clause 39.4 of is 456 it already mentioned that "strength of compression member with helical reinforcement = 1.05 Pu" Where Pu is strength of similar material with lateral ties. And initially we need to design longitudinal reinforcement before the helical reinforcement. That's why we need to the the steps (Given load x factor of safety)/1.05. And i hope you got your answer. Do comment when you face any kind of difficulty. Stay connected with civil learning online. Have a nice day.