Designing and calculation of HVAC system for Hospital by HAP (ENGLISH)

  Рет қаралды 21,391

PASSIONATE ENGINEER

PASSIONATE ENGINEER

Күн бұрын

#ICU
#Isolationroom
#PERooms
Filter selection HVAC
passionatengin...
For HVAC design
www.fiverr.com...

Пікірлер: 103
@ستارکرمانی
@ستارکرمانی 9 ай бұрын
Thanks alot man this video is so helpful and I learned many things from it 🤔🤔🤓🤓
@ManojSharma-gu8re
@ManojSharma-gu8re 3 ай бұрын
Sir, can we get the revit arch model of this drawing for practice? Or any other model for practice?
@muntekimgicirbey
@muntekimgicirbey 4 жыл бұрын
Hi, again many thanks for your video. I have a question about the software. I want to see the effect of filtration like HEPA filters on energy consumption of the HVAC system ( mostly pressure drop related energy consumption). Is it possible to do with this software? If not, do you have any suggestions?
@yokeleetan8525
@yokeleetan8525 3 жыл бұрын
sorry please check your input data and definition. you only input the walls if your walls are external walls exposed to sunlight. for internal wall, please use partition. and floor above conditioned space means that your calculated room is above another room which is conditioned to same room temperature.
@passionateengineer04
@passionateengineer04 3 жыл бұрын
Yes, you are right but these are only just examples. Select wall that are exposed, it depends on orientation of building. For internal walls you will use partition walls and fo roof also.
@JWu-jt7fz
@JWu-jt7fz 2 жыл бұрын
Exactly that's what I was thinking when I saw this
@johneziekelcagape5694
@johneziekelcagape5694 5 ай бұрын
Hello, very informative. CAn i ask where to find the sofware that you used for cooling load calculations?
@passionateengineer04
@passionateengineer04 5 ай бұрын
HAP 4.9 or 5.1 can be downloaded from internet for free
@anirudhayagorai678
@anirudhayagorai678 2 жыл бұрын
Sir, ideal place of HVAC department in Hospital ? which floor? can i keep it at basement ?
@passionateengineer04
@passionateengineer04 2 жыл бұрын
Basement
@anirudhayagorai678
@anirudhayagorai678 2 жыл бұрын
@@passionateengineer04 thank you
@amarbhaskare212
@amarbhaskare212 Жыл бұрын
Nee ductless AHU systems ...are they NABH accredited?
@passionateengineer04
@passionateengineer04 Жыл бұрын
Yes, if it follows guidelines. Do you want to use it in OT?
@SonuChoudhary-hd9sg
@SonuChoudhary-hd9sg 3 ай бұрын
I think there is some problem in this video regarding that and window exposure in its properties you expose all 4-side wall how???
@passionateengineer04
@passionateengineer04 3 ай бұрын
It's just for calculations.all depends on the building orientation
@muzaffershaik8336
@muzaffershaik8336 Жыл бұрын
hello sir, how to add recirculation air in HAP software( i mean recirculation Air changes per hour ACH) please clarify?
@passionateengineer04
@passionateengineer04 Жыл бұрын
drive.google.com/file/d/1PMU8bPZZc_3kQ-eTngDEHpIr9TlZ7RGt/view?usp=drivesdk You will find your answer in the above link. Thank you
@muzaffershaik8336
@muzaffershaik8336 Жыл бұрын
@@passionateengineer04....... Sir kindly give permission to access above link
@passionateengineer04
@passionateengineer04 Жыл бұрын
@@muzaffershaik8336 you can download it and can edit in your PC. Thank you
@KR_11117
@KR_11117 11 ай бұрын
I have a question, you defined room one as zone 1, is that correct? also how could I gain access to the software, is there a free download, or a website where I could purchase a membership? Thank you so much this has been so helpful, I'm a mechanical Engineer in NYC and I'm working on a project to design a HVCA system for a two story house....Thank you again for the video and the help
@passionateengineer04
@passionateengineer04 11 ай бұрын
Yes room as a zone,you can download a crack version of software but it's better to buy it from the carrier website. HAP v5.1. Thank you
@KR_11117
@KR_11117 11 ай бұрын
@@passionateengineer04 Thank you so much!
@snowden6846
@snowden6846 4 жыл бұрын
thank you btw what software you are using to calculate? hope you can share it thanks from the 🇵🇭
@passionateengineer04
@passionateengineer04 4 жыл бұрын
Hourly analysis Program (HAP 4.9)
@gardineatawreed3949
@gardineatawreed3949 6 ай бұрын
God bless you
@riyadhkadom1442
@riyadhkadom1442 4 жыл бұрын
Very useful video thank you so much
@cameronfelix5186
@cameronfelix5186 Жыл бұрын
Can you tell me what hvac air conditioning and ventilation system is used in intensive care unit
@passionateengineer04
@passionateengineer04 Жыл бұрын
Double skin DX Ahu with condensing unit, with hepa filter in terminal.
@maurimix0
@maurimix0 2 жыл бұрын
Does your design have recirculated air?
@passionateengineer04
@passionateengineer04 2 жыл бұрын
Yes in ICU
@cameronfelix5186
@cameronfelix5186 Жыл бұрын
Can you state where you got this information from please?
@passionateengineer04
@passionateengineer04 Жыл бұрын
ASHRAE 170, FDC
@bimmakersonline459
@bimmakersonline459 3 жыл бұрын
nice video very well done
@muzaffershaik8336
@muzaffershaik8336 Жыл бұрын
Sir. in HAP software, Equipment class: Hygienic units not available plz tell me how to add
@passionateengineer04
@passionateengineer04 Жыл бұрын
Can you please guide me why you want to add a Hygienic unit in HAP? Because AHU is enough in system data for cleanroom and others. If your country have high humidity in some seasons than you have to calculate load on that temperature in which humidity is high, else you can use dedicated software for load calculation of cleanroom and healthcare facility.
@muzaffershaik8336
@muzaffershaik8336 Жыл бұрын
@@passionateengineer04 sir in our country we have high humidity and i am doing calculations for Health care facility (veterinary clinic) (Rooms , Surgical, Pharmacy, and Examination/Treatment rooms) for that i need to select hygienic units
@passionateengineer04
@passionateengineer04 Жыл бұрын
@@muzaffershaik8336 you need to calculate load at high humidity, e.g in August humidity is high, so you need to calculate load on these parameters not on ambient temperature. Once you get the load, then you need to select hygienic AHU based manufacturer selection.
@muzaffershaik8336
@muzaffershaik8336 Жыл бұрын
@@passionateengineer04 ok thank you sir
@hunzalaahmed7129
@hunzalaahmed7129 3 жыл бұрын
Sir can u tell me the name of this hospital for which u have done Room 1 calculations
@passionateengineer04
@passionateengineer04 3 жыл бұрын
Sorry its confidential
@iqubalmit
@iqubalmit 8 күн бұрын
Can you provide me video for isolation room HAP design?
@passionateengineer04
@passionateengineer04 5 күн бұрын
Sure
@iqubalmit
@iqubalmit 5 күн бұрын
@@passionateengineer04 I'm waiting
@Shamiyusif
@Shamiyusif 4 жыл бұрын
Why u are considering all 4 wall? , you need to consider the wall facing outside and other wall shall be partitions wall if it is not air conditioned
@passionateengineer04
@passionateengineer04 4 жыл бұрын
It depends on your building orientation and exposure, if 3 walls are exposed than do calculation for these 3 walls and consider 4 th one is partitioned space or you can only do calculation for 3 walls only. in video these are just examples everyone have different scenarios.
@mohamednaseer5681
@mohamednaseer5681 4 жыл бұрын
Hi bro,I'm go with fcu So what I select air system type?
@passionateengineer04
@passionateengineer04 4 жыл бұрын
Fcu is not suitable for hospitals, or you can use ducted type with filter bank.
@sonao4201
@sonao4201 5 ай бұрын
in Patient room, why outdoor ventilation air =0 , SA=280 CFM, it means using 100% RA, I seen you input= 23 CFM but result =0
@passionateengineer04
@passionateengineer04 5 ай бұрын
Yes, you right, i think it was mistakenly removed, during video recording. You can follow the procedure by yourself, i was teaching the method to do such calculations
@johnphilip7084
@johnphilip7084 Жыл бұрын
hi dear many thanks for your video.Is it possible have that excel file
@gauravnalavade3470
@gauravnalavade3470 3 жыл бұрын
Sir thank you for this video Can we use HAP for pressurisation room if yes then how to do it please tell me
@passionateengineer04
@passionateengineer04 3 жыл бұрын
Yes you can use by ACH method.
@gauravnalavade3470
@gauravnalavade3470 3 жыл бұрын
@@passionateengineer04 thank you so much for your valuable reply sir can please give me the clean room design related books and excel file ( heat load with pressurisation) at nalavadegaurav@gmail.com
@passionateengineer04
@passionateengineer04 3 жыл бұрын
Ok i will share, just give me reminder on my email.
@gauravnalavade3470
@gauravnalavade3470 3 жыл бұрын
@@passionateengineer04 what is your email id sir
@passionateengineer04
@passionateengineer04 3 жыл бұрын
Naqqash.sajid@gmail.com
@abidmohd006
@abidmohd006 3 жыл бұрын
Why did you give 100 percent ventilation when it was asking only 15 percent extra exhaust?
@passionateengineer04
@passionateengineer04 3 жыл бұрын
15% extra exhaust mean you have to exhaust 15% more air than supply air.
@abidmohd006
@abidmohd006 3 жыл бұрын
PASSIONATE ENGINEER yes but you gave 100 percent ventilation there
@passionateengineer04
@passionateengineer04 3 жыл бұрын
Yes but we do that in excelsheet later, like once we get the total exhaust cfm we add 15 per more
@crazycontroller7751
@crazycontroller7751 Жыл бұрын
Kindly explain how to design a room with a negative pressure in HAP.
@passionateengineer04
@passionateengineer04 Жыл бұрын
Negative pressure means more exhaust than fresh air, you need to account for 100% fresh air and put direct exhaust cfm in the thermostat option. This way you can calculate load for negative rooms.
@passionateengineer04
@passionateengineer04 Жыл бұрын
I will try to upload a video on this topic
@crazycontroller7751
@crazycontroller7751 Жыл бұрын
@@passionateengineer04 thanks for reply. i have done the same but didn.t find any information in HAP report regarding the negative pressure. kindly make a dedicated video for design of negative pressure rooms in HAP.
@crazycontroller7751
@crazycontroller7751 Жыл бұрын
@@passionateengineer04 fresh air means Outdoor air?
@passionateengineer04
@passionateengineer04 Жыл бұрын
@@crazycontroller7751 yes
@faisalhussain2279
@faisalhussain2279 3 жыл бұрын
Sir what is mean by Group A and Group E diffusers in ASHRAE standard 170?
@passionateengineer04
@passionateengineer04 3 жыл бұрын
Group A: In or near ceiling, horizontal discharge. Group B: In or near floor, vertical non-spreading discharge. Group C: In or near floor, vertical spreading discharge. Group D: In or near floor, horizontal discharge. Group E: In or near ceiling, vertical discharge.
@faisalhussain2279
@faisalhussain2279 3 жыл бұрын
@@passionateengineer04 tnk u so much sir ❣
@faisalhussain2279
@faisalhussain2279 3 жыл бұрын
@@passionateengineer04 Sir can you share with me your ductwork in sad micu and isolation room just for my understanding that sir how you done ductwork please sir share with me that will be your kindness❣ my email sir👉 faisalhussain8899@gmail.com
@PremKumar-ws1br
@PremKumar-ws1br 4 жыл бұрын
Please make a one video of ahu coil selection
@passionateengineer04
@passionateengineer04 4 жыл бұрын
Ok i will make one
@ganeshkamble6892
@ganeshkamble6892 3 жыл бұрын
Thanks in advance
@fawadahmad308
@fawadahmad308 3 жыл бұрын
Hello sir, I have a final year year project on HVAC, can you plzz give me your nmber, i want to discuss my project that how i can strt it, i will be very thankfull Thank you
@junchristianberden8922
@junchristianberden8922 3 жыл бұрын
Clean room design pls..
@vickyk7165
@vickyk7165 3 жыл бұрын
Can you share the documents that you used in this video
@passionateengineer04
@passionateengineer04 3 жыл бұрын
Link is in description
@PremKumar-ws1br
@PremKumar-ws1br 4 жыл бұрын
Sir please upload a video on dehumidified air calculation 🙏
@passionateengineer04
@passionateengineer04 4 жыл бұрын
Ok
@vuyisilenkosi6601
@vuyisilenkosi6601 3 жыл бұрын
@@passionateengineer04 please
@iamnobody3464
@iamnobody3464 4 жыл бұрын
Nice video. Make a video on heppa filter sizing.
How Hospital Isolation Rooms Work
5:19
MEP Academy
Рет қаралды 6 М.
Learn Heat-load calculation for Pharmaceutical Area and Hospitals by HAP.
14:52
ДЕНЬ УЧИТЕЛЯ В ШКОЛЕ
01:00
SIDELNIKOVVV
Рет қаралды 3,6 МЛН
Кәсіпқой бокс | Жәнібек Әлімханұлы - Андрей Михайлович
48:57
Kluster Duo #настольныеигры #boardgames #игры #games #настолки #настольные_игры
00:47
The selfish The Joker was taught a lesson by Officer Rabbit. #funny #supersiblings
00:12
Funny superhero siblings
Рет қаралды 10 МЛН
Which software is used for HVAC Engineering?
7:20
AEC Learn
Рет қаралды 16 М.
Cooling Load Calculation -  Cold Room hvac
14:10
The Engineering Mindset
Рет қаралды 411 М.
20 Causes of Low Indoor Airflow on Furnaces and Air Conditioners!
8:33
AC Service Tech LLC
Рет қаралды 353 М.
Load Design Output Interpretation in TRACE 700
21:32
Trane Commercial Education and Training
Рет қаралды 21 М.
Transformer Ventilation System Design and Calculation
8:25
PASSIONATE ENGINEER
Рет қаралды 687
Operating Room Air Distribution Webinar
48:19
Krueger HVAC
Рет қаралды 17 М.
Data Center HVAC Systems
20:14
MEP Academy
Рет қаралды 124 М.
Cleanroom HVAC Design Webinar
41:34
TitusHVAC
Рет қаралды 132 М.
ДЕНЬ УЧИТЕЛЯ В ШКОЛЕ
01:00
SIDELNIKOVVV
Рет қаралды 3,6 МЛН